Towards smart biomanufacturing: a perspective on recent developments in industrial measurement and monitoring technologies for bio-based production processes
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
The biomanufacturing industry has now the opportunity to upgrade its production processes to be in harmony with the latest industrial revolution. Technology creates capabilities that enable smart manufacturing while still complying with unfolding regulations. However, many biomanufacturing companies, especially in the biopharma sector, still have a long way to go to fully benefit from smart manufacturing as they first need to transition their current operations to an information-driven future. One of the most significant obstacles towards the implementation of smart biomanufacturing is the collection of large sets of relevant data. Therefore, in this work, we both summarize the advances that have been made to date with regards to the monitoring and control of bioprocesses, and highlight some of the key technologies that have the potential to contribute to gathering big data. Empowering the current biomanufacturing industry to transition to Industry 4.0 operations allows for improved productivity through information-driven automation, not only by developing infrastructure, but also by introducing more advanced monitoring and control strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329 · cited 1×
“This unit can use optical [44], electrochemical [45], calorimetrical [46], or piezoelectrical principles [47].”
MethodPhase contrast, a new method for the microscopic observation of transparent objects
Zernike, F. (1942) · Physica · doi:10.1016/s0031-8914(42)80035-x · Cited by 1,068
Esmonde-White, K. A., Cuellar, M., Uerpmann, C., Lenain, B., & Lewis, I. R. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9824-1 · Cited by 332 · cited 2×
“Spectroscopic sensors have, in some occasions, been labeled ‘soft sensors’ in the bioprocessing literature due to the fact that spectroscopic data is modeled using software and these models produce information similar to hardware sensors [57, 66, 71].”
MethodBioreactor monitoring with spectroscopy and chemometrics: a review
Lourenço, N. D., Lopes, J. A., Almeida, C. F., Sarraguça, M. C., & Pinheiro, H. M. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6073-9 · Cited by 275 · cited 4×
“Notwithstanding the different objectives and end products, most biomanufacturing processes include the cultivation of microorganisms, which implies a process consisting of complex chemical, physical and biological phenomena [12].”
BackgroundMethodInfluentialSoft sensors development for on-line bioreactor state estimation
de Assis, A. J., & Filho, R. M. (2000) · Computers & Chemical Engineering · doi:10.1016/s0098-1354(00)00489-0 · Cited by 246
Soft sensors in bioprocessing: A status report and recommendations
Luttmann, R., Bracewell, D. G., Cornelissen, G., Gernaey, K. V., Glassey, J., Hass, V. C., Kaiser, C., Preusse, C., Striedner, G., & Mandenius, C. (2012) · Biotechnology Journal · doi:10.1002/biot.201100506 · Cited by 238 · cited 3×
“Examples and more details on the development and implementation of soft sensors in the biomanufacturing industry are given in [6, 66].”
BackgroundMethodSelf-citationSensor systems for bioprocess monitoring
Biechele, P., Busse, C., Solle, D., Scheper, T., & Reardon, K. (2015) · Engineering in Life Sciences · doi:10.1002/elsc.201500014 · Cited by 224 · cited 2×
“AI Artificial intelligence BCA Background corrected absorption NAD(P)H Nicotinamide adenine dinucleotide phosphate FDA Food and drug administration FTIR Fourier-transform infrared spectroscopy GC–MS Gas chromatography–Mass spectrometry GFP Green fluorescent protein GMP Good manufacturing practice HMI Human machine int…”
BackgroundClaßen, J., Aupert, F., Reardon, K. F., Solle, D., & Scheper, T. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-0068-x · Cited by 176
Rolinger, L., Rüdt, M., & Hubbuch, J. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02407-z · Cited by 126 · cited 1×
“Even though spectroscopic sensors fall in line with the PAT initiative [55] and seem to be a promising step towards smart manufacturing, there are far more applications of spectroscopy published in research than in industry.”
BackgroundOn-line soft sensing in upstream bioprocessing
Randek, J., & Mandenius, C.-F. (2018) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2017.1312271 · Cited by 86 · cited 3×
“Examples and more details on the development and implementation of soft sensors in the biomanufacturing industry are given in [6, 66].”
BackgroundChadwick, D. T., McDonnell, K. P., Brennan, L. P., Fagan, C. C., & Everard, C. D. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.11.006 · Cited by 62 · cited 4×
“Even though the samples are collected at regular time-intervals (manually or automatically), time delays due Temperature pO2 pH On-line head space sampling In-line Off-gas Air, O2, CO2 Pressure Viscosity Stirrer speed Assay instrumentation: PTR-MS GC-MS MALDI-TOF-MS NMR FIA Flow cytometry At-line Tens of minutes On-li…”
BackgroundInfluentialGolabgir, A., & Herwig, C. (2016) · Chemie Ingenieur Technik · doi:10.1002/cite.201500101 · Cited by 47
Marbà-Ardébol, A.-M., Emmerich, J., Neubauer, P., & Junne, S. (2017) · Process Biochemistry · doi:10.1016/j.procbio.2016.11.003 · Cited by 22 · cited 1×
“Furthermore, the cell size was recently correlated to the accumulation of an internal product (fatty acids) in microalgae [101].”
Background
Cited by
Modern Sensor Tools and Techniques for Monitoring, Controlling, and Improving Cell Culture Processes
Reyes, S. J., Durocher, Y., Pham, P. L., & Henry, O. (2022) · Processes · doi:10.3390/pr10020189 · Cited by 130
Challenges in the Development of Soft Sensors for Bioprocesses: A Critical Review
Brunner, V., Siegl, M., Geier, D., & Becker, T. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.722202 · Cited by 100
Perfusion culture of Chinese Hamster Ovary cells for bioprocessing applications
MacDonald, M. A., Nöbel, M., Roche Recinos, D., Martínez, V. S., Schulz, B. L., Howard, C. B., Baker, K., Shave, E., Lee, Y. Y., Marcellin, E., et al. (2022) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2021.1998821 · Cited by 55
“0 offers the potential to satisfy the increasing demand [1].”
BackgroundThe application of bubble column photobioreactor for algal cultivation
O'Higgins, L., Haider, M. N., Verma, N., & Bose, A. (2025) · Algal Bioreactors · doi:10.1016/b978-0-443-14058-7.00003-8 · Cited by 6
In-line fiber optical sensor for detection of IgG aggregates in affinity chromatography
Tran, T., Gustavsson, R., Martinsson, E., Bergqvist, F., Axen, A., Lundström, I., Mandenius, C.-F., & Aili, D. (2024) · Journal of Chromatography A · doi:10.1016/j.chroma.2024.465129 · Cited by 5
Metadata
- Authors
- Gargalo, C. L., Udugama, I., Pontius, K., Lopez, P. C., Nielsen, R. F., Hasanzadeh, A., Mansouri, S. S., Bayer, C., Junicke, H., & Gernaey, K. V.
- Venue
- Journal of Industrial Microbiology and Biotechnology
- Publisher
- Oxford University Press (OUP)
- Published
- 2020-11-01
- Volume
- 47
- Issue
- 11
- Pages
- 947-964
- ISSN
- 1367-5435 (ISSN-L)
- 1476-5535
- OpenAlex
- W3083888592
- Cited by
- 133
- References
- 13
- FWCI
- 10.55
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.