Real-time intradermal continuous glucose monitoring using a minimally invasive microneedle-based system
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
Continuous glucose monitoring (CGM) has the potential to greatly improve diabetes management. The aim of this work is to show a proof-of-concept CGM device which performs minimally invasive and minimally delayed in-situ glucose sensing in the dermal interstitial fluid, combining the advantages of microneedle-based and commercially available CGM systems. The device is based on the integration of an ultra-miniaturized electrochemical sensing probe in the lumen of a single hollow microneedle, separately realized using standard silicon microfabrication methods. By placing the sensing electrodes inside the lumen facing an opening towards the dermal space, real-time measurement purely can be performed relying on molecular diffusion over a short distance. Furthermore, the device relies only on passive capillary lumen filling without the need for complex fluid extraction mechanisms. Importantly, the transdermal portion of the device is 50 times smaller than that of commercial products. This allows access to the dermis and simultaneously reduces tissue trauma, along with being virtually painless during insertion. The three-electrode enzymatic sensor alone was previously proven to have satisfactory sensitivity (1.5 nA/mM), linearity (up to 14 mM), selectivity, and long-term stability (up to 4 days) in-vitro. In this work we combine this sensor technology with microneedles for reliable insertion in forearm skin. In-vivo human tests showed the possibility to correctly and dynamically track glycaemia over time, with approximately 10 min delay with respect to capillary blood control values, in line with the expected physiological lag time. The proposed device can thus reduce discomfort and potentially enable less invasive real-time CGM in diabetic patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707 · cited 1×
“Moreover, several commercial CGM devices have been presented (Csöregi et al. 1995; Feldman et al. 2003; Heller and Feldman 2008; Rodbard 2016; Yoo and Lee 2010) and released to the market since the early 2000s.”
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247 · cited 1×
“In particular, to performminimally invasive glucose sensing, transdermal electrochemical sensors remain the most common and reliable solution (Bandodkar and Wang 2014; Heller and Feldman 2010; Vashist et al. 2011; Wang 2008).”
Glucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137 · cited 1×
“Moreover, several commercial CGM devices have been presented (Csöregi et al. 1995; Feldman et al. 2003; Heller and Feldman 2008; Rodbard 2016; Yoo and Lee 2010) and released to the market since the early 2000s.”
Larrañeta, E., Lutton, R. E. M., Woolfson, A. D., & Donnelly, R. F. (2016) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2016.03.001 · Cited by 964 · cited 1×
“Finally, microneedle arrays for intradermal drug delivery, such as insulin injection, have previously been reported (Ita 2015; Larrañeta et al. 2016; Van Der Maaden et al. 2012; Roxhed et al. 2008), and this feature combined with microneedle-based CGM could enable a minimally invasive closed-loop…”
Continuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities
Rodbard, D. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0417 · Cited by 737 · cited 1×
“Moreover, several commercial CGM devices have been presented (Csöregi et al. 1995; Feldman et al. 2003; Heller and Feldman 2008; Rodbard 2016; Yoo and Lee 2010) and released to the market since the early 2000s.”
Microneedle technologies for (trans)dermal drug and vaccine delivery
van der Maaden, K., Jiskoot, W., & Bouwstra, J. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.01.042 · Cited by 651 · cited 2×
“Finally, microneedle arrays for intradermal drug delivery, such as insulin injection, have previously been reported (Ita 2015; Larrañeta et al. 2016; Van Der Maaden et al. 2012; Roxhed et al. 2008), and this feature combined with microneedle-based CGM could enable a minimally invasive closed-loop system.”
Transdermal Delivery of Drugs with Microneedles—Potential and Challenges
Ita, K. (2015) · Pharmaceutics · doi:10.3390/pharmaceutics7030090 · Cited by 530 · cited 1×
“Finally, microneedle arrays for intradermal drug delivery, such as insulin injection, have previously been reported (Ita 2015; Larrañeta et al. 2016; Van Der Maaden et al. 2012; Roxhed et al. 2008), and this feature combined with microneedle-based CGM could enable a minimally invasive closed-loop…”
Boyne, M. S., Silver, D. M., Kaplan, J., & Saudek, C. D. (2003) · Diabetes · doi:10.2337/diabetes.52.11.2790 · Cited by 404 · cited 1×
“…lag time between blood glucose and interstitial fluid glucose concentrations, which is of the order of 4 to 12 min (Aussedat et al. 2000; Boyne et al. 2003), and the CGMS delay itself impedes real-time monitoring, and hence the possibility to take medical decisions, such as insulin…”
Cited by
Continuous glucose monitoring and metrics for clinical trials: an international consensus statement
Battelino, T., Alexander, C. M., Amiel, S. A., Arreaza-Rubin, G., Beck, R. W., Bergenstal, R. M., Buckingham, B. A., Carroll, J., Ceriello, A., Chow, E., et al. (2023) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(22)00319-9 · Cited by 831
Villena Gonzales, W., Mobashsher, A., & Abbosh, A. (2019) · Sensors · doi:10.3390/s19040800 · Cited by 772
Tehrani, F., Teymourian, H., Wuerstle, B., Kavner, J., Patel, R., Furmidge, A., Aghavali, R., Hosseini-Toudeshki, H., Brown, C., Zhang, F., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00887-1 · Cited by 625
Non-Invasive Blood Glucose Monitoring Technology: A Review
Tang, L., Chang, S. J., Chen, C.-J., & Liu, J.-T. (2020) · Sensors · doi:10.3390/s20236925 · Cited by 481
Broza, Y. Y., Zhou, X., Yuan, M., Qu, D., Zheng, Y., Vishinkin, R., Khatib, M., Wu, W., & Haick, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00437 · Cited by 461
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Lab under the Skin: Microneedle Based Wearable Devices
Teymourian, H., Tehrani, F., Mahato, K., & Wang, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002255 · Cited by 310
Lee, I., Probst, D., Klonoff, D., & Sode, K. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113054 · Cited by 288
Hollow microneedles: A perspective in biomedical applications
Cárcamo-Martínez, Á., Mallon, B., Domínguez-Robles, J., Vora, L. K., Anjani, Q. K., & Donnelly, R. F. (2021) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2021.120455 · Cited by 285
Wearable and Mobile Sensors for Personalized Nutrition
Sempionatto, J. R., Montiel, V. R.-V., Vargas, E., Teymourian, H., & Wang, J. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00553 · Cited by 237
Microneedles: materials, fabrication, and biomedical applications
Luo, X., Yang, L., & Cui, Y. (2023) · Biomedical Microdevices · doi:10.1007/s10544-023-00658-y · Cited by 219
Li, Y., Zhang, H., Yang, R., Laffitte, Y., Schmill, U., Hu, W., Kaddoura, M., Blondeel, E. J. M., & Cui, B. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0077-y · Cited by 210
Zheng, M., Wang, Z., Chang, H., Wang, L., Chew, S. W. T., Lio, D. C. S., Cui, M., Liu, L., Tee, B. C. K., & Xu, C. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901683 · Cited by 207
Vora, L. K., Sabri, A. H., McKenna, P. E., Himawan, A., Hutton, A. R. J., Detamornrat, U., Paredes, A. J., Larrañeta, E., & Donnelly, R. F. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00108-7 · Cited by 193
Wearable flexible microfluidic sensing technologies
Chen, S., Qiao, Z., Niu, Y., Yeo, J. C., Liu, Y., Qi, J., Fan, S., Liu, X., Lee, J. Y., & Lim, C. T. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00094-w · Cited by 168
“Microneedles with hollow, porous, solid or hydrogel-based swelling structures can also access or collect ISF and integrate sensors on the surface 115,116 or inside the hollow channel 117 and porous hydrogels 114 for in situ monitoring.”
BackgroundBiosensing in dermal interstitial fluid using microneedle based electrochemical devices
Madden, J., O'Mahony, C., Thompson, M., O'Riordan, A., & Galvin, P. (2020) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2020.100348 · Cited by 161
Wearable Skin Sensors and Their Challenges: A Review of Transdermal, Optical, and Mechanical Sensors
Ahmad Tarar, A., Mohammad, U., & K. Srivastava, S. (2020) · Biosensors · doi:10.3390/bios10060056 · Cited by 119
“…researchers are focusing on expanding the application of microneedles as diagnostic But in recent times, researchers are focusing on expanding the application of microneedles as diagnostic sensors by accessing the interstitial fluid [66–68]. sensors by accessing the interstitial fluid [66–68].”
Background
Metadata
- Authors
- Ribet, F., Stemme, G., & Roxhed, N.
- Venue
- Biomedical Microdevices
- Published
- 2018-12
- Volume
- 20
- Issue
- 4
- Pages
- 101-101
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W2904140750
- Cited by
- 181
- References
- 51
- FWCI
- 4.42
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.