A method to qualitatively assess arm use in stroke survivors in the home environment
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Wearable sensor technology has enabled unobtrusive monitoring of arm movements of stroke survivors in the home environment. However, the most widely established method, based on activity counts, provides quantitative rather than qualitative information on arm without functional insights, and is sensitive to passive arm movements during ambulatory activities. We propose a method to quantify functionally relevant arm use in stroke survivors relying on a single wrist-worn inertial measurement unit. Orientation of the forearm during movements is measured in order identify gross arm movements. The method is validated in 10 subacute/chronic stroke survivors wearing inertial sensors at 5 anatomical locations for 48 h. Measurements are compared to conventional activity counts and to a test for gross manual dexterity. Duration of gross arm movements of the paretic arm correlated significantly better with the Box and Block Test ( $$r=0.95$$ r = 0.95 ) than conventional activity counts when walking phases were included ( $$r=0.69$$ r = 0.69 ), and similar results were found when comparing ratios of paretic and non-paretic arms for gross movements and activity counts. The proposed gross arm movement metric is robust against passive arm movements during ambulatory activities and requires only a single-sensor module placed at the paretic wrist for the assessment of functionally relevant arm use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tests for comparing elements of a correlation matrix
Steiger, J. H. (1980) · Psychological Bulletin · doi:10.1037/0033-2909.87.2.245 · Cited by 4,621 · cited 1×
“Correlations of AC and GM and arm use duration were compared with the Steiger’s Z-test for dependent correlations [25] in order to identify significant differences in correlation strength.”
Measuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647 · cited 1×
“The use of magnetometers could add an absolute reference in the horizontal plane and reduce drift, but these are “difficult to use in the vicinity of ferromagnetic metals” [16], which are often encountered in daily settings (e.”
Monitoring of Physical Activity after Stroke: A Systematic Review of Accelerometry-Based Measures
Gebruers, N., Vanroy, C., Truijen, S., Engelborghs, S., & De Deyn, P. P. (2010) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2009.10.025 · Cited by 293
Uswatte, G., Giuliani, C., Winstein, C., Zeringue, A., Hobbs, L., & Wolf, S. L. (2006) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2006.06.006 · Cited by 241 · cited 2×
“To the best of our knowledge none of the previous studies [10, 3, 11, 12, 13, 14, 6] corrected for this passive activity resulting from ambulation by means of an additional shank sensor, thus likely distorting the arm activity levels of severely impaired subjects.”
Uswatte, G., Foo, W. L., Olmstead, H., Lopez, K., Holand, A., & Simms, L. B. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2005.01.010 · Cited by 233
Upper Extremity Use in People with Hemiparesis in the First Few Weeks After Stroke
Lang, C. E., Wagner, J. M., Edwards, D. F., & Dromerick, A. W. (2007) · Journal of Neurologic Physical Therapy · doi:10.1097/npt.0b013e31806748bd · Cited by 216 · cited 2×
“, passive arm swinging during ambulatory activities, which leads to an overestimation of realworld arm activity [1, 12].”
A Novel Approach to Monitor Rehabilitation Outcomes in Stroke Survivors Using Wearable Technology
Patel, S., Hughes, R., Hester, T., Stein, J., Akay, M., Dy, J. G., & Bonato, P. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2038727 · Cited by 170 · cited 1×
“Inertial sensors worn in a clinical setting during assessments such as the Functional Ability Scale of the Wolf Motor Function Test [7, 10, 19, 20] or the Fugl-Meyer Assessment [3], have allowed the reconstruction of these scores based on the recorded signals, demonstrating that qualitative information of arm movement…”
Assessment of Arm Activity Using Triaxial Accelerometry in Patients With a Stroke
van der Pas, S. C., Verbunt, J. A., Breukelaar, D. E., van Woerden, R., & Seelen, H. A. (2011) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.02.021 · Cited by 131 · cited 2×
“This may have biased activity levels in previous studies [1, 4, 26, 30].”
Inertial measurements of upper limb motion
Zhou, H., Hu, H., & Tao, Y. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0063-z · Cited by 106 · cited 1×
“In contrast to accelerometers only, inertial measurement units (IMUs) comprising accelerometers and gyroscopes (angular rate sensors) can be used to precisely measure and monitor movements of body segments and have been proposed for portable motion capture of gait [6, 13] or arm movements [35, 36].”
de Niet, M., Bussmann, J. B., Ribbers, G. M., & Stam, H. J. (2007) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.06.005 · Cited by 94
Estimating fugl-meyer clinical scores in stroke survivors using wearable sensors
Del Din, S., Patel, S., Cobelli, C., & Bonato, P. (2011) · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2011.6091444 · Cited by 90
Thrane, G., Emaus, N., Askim, T., & Anke, A. (2011) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0676 · Cited by 89
Using Wearable Sensors to Measure Motor Abilities following Stroke
Hester, T., Hughes, R., Sherrill, D. M., Knorr, B., Akay, M., Stein, J., & Bonato, P. (2006) · International Workshop on Wearable and Implantable Body Sensor Networks (BSN'06) · doi:10.1109/bsn.2006.57 · Cited by 82 · cited 1×
“Inertial sensors worn in a clinical setting during assessments such as the Functional Ability Scale of the Wolf Motor Function Test [7, 10, 19, 20] or the Fugl-Meyer Assessment [3], have allowed the reconstruction of these scores based on the recorded signals, demonstrating that qualitative information of arm movement…”
Actigraphic Measurement of Motor Deficits in Acute Ischemic Stroke
Gebruers, N., Truijen, S., Engelborghs, S., Nagels, G., Brouns, R., & De Deyn, P. P. (2008) · Cerebrovascular Diseases · doi:10.1159/000160210 · Cited by 61 · cited 1×
“This may have biased activity levels in previous studies [1, 4, 26, 30].”
Actigraphy – A Useful Tool for Motor Activity Monitoring in Stroke Patients
Reiterer, V., Sauter, C., Klösch, G., Lalouschek, W., & Zeitlhofer, J. (2008) · European Neurology · doi:10.1159/000157882 · Cited by 44 · cited 1×
“Activity counts (AC) derived from the acceleration signals provide quantitative information about arm activity, such as total duration [27, 28] and intensity of movements [5, 23].”
Cited by
Maceira-Elvira, P., Popa, T., Schmid, A.-C., & Hummel, F. C. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0612-y · Cited by 265
Lee, S. I., Adans-Dester, C. P., Grimaldi, M., Dowling, A. V., Horak, P. C., Black-Schaffer, R. M., Bonato, P., & Gwin, J. T. (2018) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2018.2829208 · Cited by 119
The use of a finger-worn accelerometer for monitoring of hand use in ambulatory settings
Liu, X., Rajan, S., Ramasarma, N., Bonato, P., & Lee, S. I. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2821136 · Cited by 39
“Although these metrics provide simple and intuitive quantification, they capture primarily gross arm movements, such as passive arm swings during walking, which are less relevant to the goal-directed use of the stroke-affected upper limb as part of patients’ essential ADL [13].”
BackgroundTowards data-driven stroke rehabilitation via wearable sensors and deep learning
Kaku, A., Parnandi, A., Venkatesan, A., Pandit, N., Schambra, H., & Fernandez-Granda, C. (2020) · arXiv · doi:10.48550/arxiv.2004.08297 · Cited by 30
Metadata
- Authors
- Leuenberger, K., Gonzenbach, R., Wachter, S., Luft, A., & Gassert, R.
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2016-04-22
- Volume
- 55
- Issue
- 1
- Pages
- 141-150
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2340924002
- Cited by
- 86
- References
- 15
- FWCI
- 7.80
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.