Dual- and multi-energy CT: approach to functional imaging
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
The energy spectrum of X-ray photons after passage through an absorber contains information about its elemental composition. Thus, tissue characterisation becomes feasible provided that absorption characteristics can be measured or differentiated. Dual-energy CT uses two X-ray spectra enabling material differentiation by analysing material-dependent photo-electric and Compton effects. Elemental concentrations can thereby be determined using three-material decomposition algorithms. In comparison to dual-energy CT used in clinical practice, recently developed energy-sensitive photon-counting detectors sample the material-specific attenuation curves at multiple energy levels and within narrow energy bands; the latter allows the detection of element-specific, k-edge discontinuities of the photo-electric cross section. Multi-energy CT imaging therefore is able to concurrently identify multiple materials with increased accuracy. These specific data on material distribution provide information beyond morphological CT, and approach functional imaging. This article reviews the principles of dual- and multi-energy CT imaging, hardware approaches and clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Energy-selective reconstructions in X-ray computerised tomography
Alvarez, R. E., & Macovski, A. (1976) · Physics in Medicine & Biology · doi:10.1088/0031-9155/21/5/002 · Cited by 2,013 · cited 4×
“Computed tomography enables material differentiation by analysing two X-ray spectra, termed dual-energy imaging, allowing the analysis of Compton and photoelectric effects [ 1 , 2].”
BackgroundMethodInfluentialMaterial differentiation by dual energy CT: initial experience
Johnson, T. R. C., Krauß, B., Sedlmair, M., Grasruck, M., Bruder, H., Morhard, D., Fink, C., Weckbach, S., Lenhard, M., Schmidt, B., et al. (2007) · European Radiology · doi:10.1007/s00330-006-0517-6 · Cited by 1,510 · cited 4×
“materials such as calcium and iodine may have similar CT numbers at certain concentrations and therefore will not be differentiated in a single-energy CT acquisition [6].”
BackgroundMethodInfluentialFirst performance evaluation of a dual-source CT (DSCT) system
Flohr, T. G., McCollough, C. H., Bruder, H., Petersilka, M., Gruber, K., Süβ, C., Grasruck, M., Stierstorfer, K., Krauss, B., Raupach, R., et al. (2006) · European Radiology · doi:10.1007/s00330-005-2919-2 · Cited by 1,413 · cited 4×
“Finally, because of a small detector size the imaging field of view was limited to the central 26 cm with first generation dual-source CT hindering imaging of peripheral body parts [8, 26, 28, 34].”
BackgroundInfluentialSchlomka, J. P., Roessl, E., Dorscheid, R., Dill, S., Martens, G., Istel, T., Bäumer, C., Herrmann, C., Steadman, R., Zeitler, G., et al. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/15/002 · Cited by 801 · cited 3×
“Organisation for Nuclear Research (CERN), has been most public with their developments [39], but recently some of the major equipment manufacturers have also announced projects [ 40 ].”
BackgroundInfluentialK-edge imaging in x-ray computed tomography using multi-bin photon counting detectors
Roessl, E., & Proksa, R. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/15/020 · Cited by 558 · cited 3×
“than one element with a high atomic number (Z-number) [5].”
BackgroundInfluentialDual energy CT: preliminary observations and potential clinical applications in the abdomen
Graser, A., Johnson, T. R. C., Chandarana, H., & Macari, M. (2009) · European Radiology · doi:10.1007/s00330-008-1122-7 · Cited by 479 · cited 3×
“Finally, because of a small detector size the imaging field of view was limited to the central 26 cm with first generation dual-source CT hindering imaging of peripheral body parts [8, 26, 28, 34].”
BackgroundEvaluation of a prototype dual‐energy computed tomographic apparatus. I. Phantom studies
Kalender, W. A., Perman, W. H., Vetter, J. R., & Klotz, E. (1986) · Medical Physics · doi:10.1118/1.595958 · Cited by 451 · cited 2×
“Other approaches were introduced through rapid-kV switching or energy-sensitive detectors [9].”
BackgroundMethodQuantitative Bone Mineral Analysis Using Dual Energy Computed Tomography
GENANT, H. K., & BOYD, D. (1977) · Investigative Radiology · doi:10.1097/00004424-197711000-00015 · Cited by 397 · cited 1×
“First attempts to differentiate materials by using the attenuation characteristics at several energy spectra date back to the 1970s [30, 31].”
BackgroundDual Energy CT Characterization of Urinary Calculi: Initial In Vitro and Clinical Experience
Graser, A., Johnson, T. R. C., Bader, M., Staehler, M., Haseke, N., Nikolaou, K., Reiser, M. F., Stief, C. G., & Becker, C. R. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e318157a144 · Cited by 341
Primak, A. N., Ramirez Giraldo, J. C., Liu, X., Yu, L., & McCollough, C. H. (2009) · Medical Physics · doi:10.1118/1.3083567 · Cited by 318 · cited 2×
“80 and 140 kVp) accompanied by significantly improving discrimination abilities [14, 23, 37 ].”
BackgroundPache, G., Krauss, B., Strohm, P., Saueressig, U., Blanke, P., Bulla, S., Schäfer, O., Helwig, P., Kotter, E., Langer, M., et al. (2010) · Radiology · doi:10.1148/radiol.10091230 · Cited by 281 · cited 1×
“recently, these ‘virtual non-calcium images’ were evaluated for detecting traumatised bone marrow [46].”
BackgroundSelf-citationNanotechnology in Medical Imaging: Probe Design and Applications
Cormode, D. P., Skajaa, T., Fayad, Z. A., & Mulder, W. J. M. (2009) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.108.165506 · Cited by 275 · cited 2×
“Many groups have been working on gold-labelled functional nano-particles [41].”
BackgroundRuzsics, B., Lee, H., Zwerner, P. L., Gebregziabher, M., Costello, P., & Schoepf, U. J. (2008) · European Radiology · doi:10.1007/s00330-008-1022-x · Cited by 231 · cited 2×
“quantification promises to add information about myocardial blood supply to the analysis of the coronary artery morphology [24, 25].”
BackgroundNoise considerations in dual energy CT scanning
Kelcz, F., Joseph, P. M., & Hilal, S. K. (1979) · Medical Physics · doi:10.1118/1.594520 · Cited by 221 · cited 3×
“voltage output is limited to the same filtration [32].”
BackgroundInfluentialAlkadhi, H., Scheffel, H., Desbiolles, L., Gaemperli, O., Stolzmann, P., Plass, A., Goerres, G. W., Luescher, T. F., Genoni, M., Marincek, B., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn044 · Cited by 182 · cited 1×
“This configuration allows for the evaluation of the coronary arteries at a high temporal resolution [36] or for the acquisition of dual-energy CT data.”
BackgroundSelf-citationDual-Energy CT as a Potential New Diagnostic Tool in the Management of Gout in the Acute Setting
Nicolaou, S., Yong-Hing, C. J., Galea-Soler, S., Hou, D. J., Louis, L., & Munk, P. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.2428 · Cited by 175 · cited 1×
“Moreover, the transfer of this uric acid identification algorithm to musculoskeletal imaging has been useful in the diagnosis of tophaceous gout [49].”
MethodTissue Signatures with Dual-Energy Computed Tomography
Di Chiro, G., Brooks, R. A., Kessler, R. M., Johnston, G. S., Jones, A. E., Herdt, J. R., & Sheridan, W. T. (1979) · Radiology · doi:10.1148/131.2.521 · Cited by 168 · cited 1×
“First attempts to differentiate materials by using the attenuation characteristics at several energy spectra date back to the 1970s [30, 31].”
BackgroundChandarana, H., Godoy, M. C. B., Vlahos, I., Graser, A., Babb, J., Leidecker, C., & Macari, M. (2008) · Radiology · doi:10.1148/radiol.2492080359 · Cited by 164 · cited 2×
“Such imaging strategies can be valuably used in vascular [18, 19], liver or kidney imaging either by reducing radiation [20, 21] or by quantifying iodine uptake [8, 22, 23].”
BackgroundSpectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE
ANDERSON, N. G., Butler, A. P. H., Scott, N. J. A., Cook, N. J., Butzer, J. S., Schleich, N., Firsching, M., Grasset, R., de Ruiter, N., Campbell, M., et al. (2010) · European Radiology · doi:10.1007/s00330-010-1768-9 · Cited by 162 · cited 4×
“Thus, a triple phase renal or liver study can be performed in a single examination reducing dose, eliminating patient movement and improving patient throughput [3].”
BackgroundInfluentialSelf-citationDual-Energy Contrast-Enhanced Computed Tomography for the Detection of Urinary Stone Disease
Scheffel, H., Stolzmann, P., Frauenfelder, T., Schertler, T., Desbiolles, L. M., Leschka, S., Marinček, B., & Alkadhi, H. (2007) · Investigative Radiology · doi:10.1097/rli.0b013e3181379bac · Cited by 128 · cited 2×
“Such imaging strategies can be valuably used in vascular [18, 19], liver or kidney imaging either by reducing radiation [20, 21] or by quantifying iodine uptake [8, 22, 23].”
BackgroundSelf-citationZhang, L. J., Wu, S. Y., Niu, J., Zhang, Z.-L., Wang, H. Z., Zhao, Y.-E., Chai, X., Zhou, C.-S., & Lu, G.-M. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.2290 · Cited by 126 · cited 1×
“3) [11, 43, 44] as well as peripheral arteries and the appendicular skeleton [12, 45].”
BackgroundDual-Energy CT for Characterization of Adrenal Nodules: Initial Experience
Gupta, R. T., Ho, L. M., Marin, D., Boll, D. T., Barnhart, H. X., & Nelson, R. C. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.3476 · Cited by 120 · cited 3×
“Such imaging strategies can be valuably used in vascular [18, 19], liver or kidney imaging either by reducing radiation [20, 21] or by quantifying iodine uptake [8, 22, 23].”
BackgroundMethodStolzmann, P., Scheffel, H., Rentsch, K., Schertler, T., Frauenfelder, T., Leschka, S., Sulser, T., Marinček, B., & Alkadhi, H. (2008) · Urological Research · doi:10.1007/s00240-008-0140-x · Cited by 106 · cited 1×
“to evaluate this application in vitro [14, 15, 48] and in vivo [13, 16], achieving sensitivities ranging from 88% to”
BackgroundSelf-citationGrosjean, R., Sauer, B., Guerra, R. M., Daudon, M., Blum, A., Felblinger, J., & Hubert, J. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.2466 · Cited by 105 · cited 1×
“results to an in vivo setting was hampered by misregistration problems [33].”
BackgroundUotani, K., Watanabe, Y., Higashi, M., Nakazawa, T., Kono, A. K., Hori, Y., Fukuda, T., Kanzaki, S., Yamada, N., Itoh, T., et al. (2009) · European Radiology · doi:10.1007/s00330-009-1358-x · Cited by 104
Characterization of Urinary Stones With Dual-Energy CT
Stolzmann, P., Leschka, S., Scheffel, H., Rentsch, K., Baumüller, S., Desbiolles, L. M., Schmidt, B. T., Marinček, B., & Alkadhi, H. (2009) · Investigative Radiology · doi:10.1097/rli.0b013e3181b9dbed · Cited by 101 · cited 3×
“without impacting on discrimination abilities [14].”
BackgroundSelf-citationDual-energy CT of the heart—Principles and protocols
Schwarz, F., Ruzsics, B., Schoepf, U. J., Bastarrika, G., Chiaramida, S. A., Abro, J. A., Brothers, R. L., Vogt, S. K., Schmidt, B. T., Costello, P., et al. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2008.09.010 · Cited by 100 · cited 2×
“quantification promises to add information about myocardial blood supply to the analysis of the coronary artery morphology [24, 25].”
BackgroundPansini, V., Rémy‐Jardin, M., Faivre, J., Schmidt, B. T., Botelho, A. D., Perez, T., Delannoy, V., Duhamel, A., & Rémy, J. (2009) · European Radiology · doi:10.1007/s00330-009-1475-6 · Cited by 71 · cited 2×
“Finally, because of a small detector size the imaging field of view was limited to the central 26 cm with first generation dual-source CT hindering imaging of peripheral body parts [8, 26, 28, 34].”
BackgroundBoll, D. T., Patil, N. A., Paulson, E. K., Merkle, E. M., Nelson, R. C., Schindera, S. T., Roessl, E., Martens, G., Proksa, R., Fleiter, T. R., et al. (2009) · Radiology · doi:10.1148/radiol.09090068 · Cited by 67 · cited 1×
“That is, photon counting detectors count individual X-ray photons within set energy ranges—also known as bins or thresholds [3, 4].”
BackgroundSpectral Coronary Multidetector Computed Tomography Angiography
Boll, D. T., Hoffmann, M. H. K., Huber, N., Bossert, A. S., Aschoff, A. J., & Fleiter, T. R. (2006) · Journal of Computer Assisted Tomography · doi:10.1097/01.rct.0000228162.70849.26 · Cited by 43 · cited 2×
“Applications under development include multi-contrast imaging [3], new contrast agents [41] and atherosclerotic plaque characterisation [ 38 , 42].”
BackgroundMethod
Cited by
Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications
McCollough, C. H., Leng, S., Yu, L., & Fletcher, J. G. (2015) · Radiology · doi:10.1148/radiol.2015142631 · Cited by 1,598
Photon-counting CT: Technical Principles and Clinical Prospects
Willemink, M. J., Persson, M., Pourmorteza, A., Pelc, N. J., & Fleischmann, D. (2018) · Radiology · doi:10.1148/radiol.2018172656 · Cited by 1,326
Industrial applications of computed tomography
De Chiffre, L., Carmignato, S., Kruth, J.-P., Schmitt, R., & Weckenmann, A. (2014) · CIRP Annals · doi:10.1016/j.cirp.2014.05.011 · Cited by 670
Vaquero, J. J., & Kinahan, P. (2015) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071114-040723 · Cited by 383
State of the Art: Dual-Energy CT of the Abdomen
Marin, D., Boll, D. T., Mileto, A., & Nelson, R. C. (2014) · Radiology · doi:10.1148/radiol.14131480 · Cited by 368
Metadata
- Authors
- Fornaro, J., Leschka, S., Hibbeln, D., Butler, A., Anderson, N., Pache, G., Scheffel, H., Wildermuth, S., Alkadhi, H., & Stolzmann, P.
- Venue
- Insights into Imaging
- Published
- 2011-01-19
- Volume
- 2
- Issue
- 2
- Pages
- 149-159
- ISSN
- 1869-4101 (ISSN-L)
- OpenAlex
- W1971360857
- Cited by
- 184
- References
- 30
- FWCI
- 5.29
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.