Sweating Rate and Sweat Sodium Concentration in Athletes: A Review of Methodology and Intra/Interindividual Variability
Open accessThe DOI matches its Crossref record; 233 of the 233 references it cites were found in a registry or an index.
Abstract
Athletes lose water and electrolytes as a consequence of thermoregulatory sweating during exercise and it is well known that the rate and composition of sweat loss can vary considerably within and among individuals. Many scientists and practitioners conduct sweat tests to determine sweat water and electrolyte losses of athletes during practice and competition. The information gleaned from sweat testing is often used to guide personalized fluid and electrolyte replacement recommendations for athletes; however, unstandardized methodological practices and challenging field conditions can produce inconsistent/inaccurate results. The primary objective of this paper is to provide a review of the literature regarding the effect of laboratory and field sweat-testing methodological variations on sweating rate (SR) and sweat composition (primarily sodium concentration [Na + ]). The simplest and most accurate method to assess whole-body SR is via changes in body mass during exercise; however, potential confounding factors to consider are non-sweat sources of mass change and trapped sweat in clothing. In addition, variability in sweat [Na + ] can result from differences in the type of collection system used (whole body or localized), the timing/duration of sweat collection, skin cleaning procedure, sample storage/handling, and analytical technique. Another aim of this paper is to briefly review factors that may impact intra/interindividual variability in SR and sweat [Na + ] during exercise, including exercise intensity, environmental conditions, heat acclimation, aerobic capacity, body size/composition, wearing of protective equipment, sex, maturation, aging, diet, and/or hydration status. In summary, sweat testing can be a useful tool to estimate athletes’ SR and sweat Na + loss to help guide fluid/electrolyte replacement strategies, provided that data are collected, analyzed, and interpreted appropriately.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Fig. 1 Frequency histograms of (a) absolute whole-body sweating rate and (b) relative whole-body sweating rate from 461 athletes (327 adults, 134 youth; 369 male, 92 female) of various sports (e.g. American Football, basketball, baseball, soccer, tennis, and endurance) tested during training or competition in various environmental conditions (15–50 °C, 20–79% relative humidity). The vertical line represents the mean value. Reproduced from Baker et al. [96], with permission](https://figures.cochat.ai/paper-figures/0c406296f9324ce4a1009eef5abc81cb/sweating-rate-and-sweat-sodium-concentration-in-athletes-a-review-of-methodology-figure-1.jpg)
![Fig. 2 Frequency histograms of (a) forearm sweat sodium concentration ([Na+]) using the absorbent patch technique and (b) predicted whole-body sweat [Na+] from 506 athletes (367 adults, 139 youth; 404 male, 102 female) of various sports (e.g. American Football, basketball, baseball, soccer, tennis, and endurance) tested during training or competition in various environmental conditions (15–50 °C, 20–79% relative humidity). The vertical line represents the mean value. Reproduced from Baker et al. [96], with permission](https://figures.cochat.ai/paper-figures/c9cba02b8bb04a6a9f0c3d59a3cc51d2/sweating-rate-and-sweat-sodium-concentration-in-athletes-a-review-of-methodology-figure-2.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Since sweat composition is modulated by a variety of factors including age, body mass, diet, and hydration status (46)”
From Regional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat (2019) · cites this paper as [46]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“a wide range of analytical techniques have been used by scientists and practitioners to measure sweat composition”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Baker 2017
The cited source says what the claim attributes to it.
In the citing paper
“Nonetheless, final sweat typically has a [K+] similar, albeit with a slightly broader range (~2–8 mmol/L), to that reported for blood plasma.29,41,42”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [29]
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“These findings agree with previous investigations of exercise sweat (21, 46, 47).”
From Regional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat (2019) · cites this paper as [46]
Experimental — accuracy not yet measuredIn the citing paper
“However, the current mechanism of potassium ion secretion in sweat is still uncertain, so the final potassium concentration in sweat may be maintained within the plasma potassium concentration range 76 .”
From A review of sampling, energy supply and intelligent monitoring for long-term sweat sensors (2022) · cites this paper as [76]
3 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · Applied Ergonomics · doi:10.1016/0003-6870(92)90318-p · Cited by 5,737
Webb, A. K. (2006) · Cited by 4,369
ACSM Position Stand: Exercise and Fluid Replacement
Convertino, V. A., Armstrong, L. E., Coyle, E. F., Mack, G. W., Sawka, M. N., Senay, L. C., & Sherman, W. M. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199610000-00045 · Cited by 1,965
Gibson, L. E., & Cooke, R. E. (1959) · Pediatrics · doi:10.1542/peds.23.3.545 · Cited by 1,434 · cited 2×
“Pilocarpine iontophoresis was standardized by Gibson and Cooke in 1959 (Quantitative Pilocarpine Iontophoretic Test [or QPIT] method [89]).”
MethodRowe, S. M., Miller, S., & Sorscher, E. J. (2005) · New England Journal of Medicine · doi:10.1056/nejmra043184 · Cited by 1,398
Balance of carbohydrate and lipid utilization during exercise: the "crossover" concept
Brooks, G. A., & Mercier, J. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.76.6.2253 · Cited by 862 · cited 1×
“In addition, the following papers provide equations to calculate mass loss from substrate oxidation [79, 85, 86] and respiratory water [79, 85].”
BackgroundBiology of sweat glands and their disorders. I. Normal sweat gland function
Sato, K., Kang, W. H., Saga, K., & Sato, K. T. (1989) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(89)70063-3 · Cited by 717 · cited 2×
“More details on the structure, function, and control of eccrine sweat glands can be found in several comprehensive reviews [19, 26, 29, 32, 44, 57].”
BackgroundAssessing Hydration Status: The Elusive Gold Standard
Armstrong, L. E. (2007) · Journal of the American College of Nutrition · doi:10.1080/07315724.2007.10719661 · Cited by 643 · cited 1×
“The simplest and most accurate method to assess WBSR is via changes in nude body mass from before to after exercise [2, 4, 78]; however, corrections for non-sweat sources of body mass change should be considered.”
MethodInvited Review: Aging and human temperature regulation
Kenney, W. L., & Munce, T. A. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00202.2003 · Cited by 577
Robinson, S., & Robinson, A. H. (1954) · Physiological Reviews · doi:10.1152/physrev.1954.34.2.202 · Cited by 514 · cited 4×
“Regarding the impact of sweat stimulation methodology on sweat composition, two studies have shown higher [Na] and [Cl] with exercise versus passive heating [98, 104].”
BackgroundInfluential
Research works printed but not linked: 5
- Kuno Y Human perspiration 1956 Springfield Charles C. Thomas Publisher
- Berne RM Levy MN Physiology 1998 St. Louis Mosby
- Ogata K Functional variations in human sweat glands, with remarks upon the regional difference of the amount of sweat J Orient Med 1935 23 98 101
- Yoshimura H Acclimatization to heat and cold. Essential problems in climatic physiology 1960 Kyoto Nankodo
- Candas V Dejours P Adaptation to extreme environments. Thermophysiological changes in man during humid heat acclimation Comparative physiology of environmental adaptations 1987 Basel Karger 76 93
Cited by
Items 301–400 of 402
Assessment of Sweat Rate in Different Sports
Das, A., & Ramesh, V. (2025) · Methods and protocols in food science · doi:10.1007/978-1-0716-4370-9_15 · Cited by 1
Customizing individual heat mitigation strategies to optimize performance in elite athletes
Sekiguchi, Y., Adams, W. M., Hosokawa, Y., Benjamin, C. L., Stearns, R. L., Huggins, R. A., & Casa, D. J. (2025) · Frontiers in Physiology · doi:10.3389/fphys.2025.1380645 · Cited by 5
“A mixed cooling method that utilizes multiple cooling strategies is more effective than a single strategy alone (Bongers et al., 2015; 2017), with a cooling strategy that can target the core (e.g., face, neck, head, torso) exhibiting greater performance benefits than those that are applied on limbs…”
Tu, A., Lai, K., Lai, J., He, S., Xiao, L., Aw, K. C., Gao, J., & Jiang, H. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3567150 · Cited by 2
“Individual variability remains the dominant factor [10].”
Cinca-Morros, S., Burtscher, M., Benito‐Lopez, F., & Álvarez‐Herms, J. (2025) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk10020220 · Cited by 2
“Extreme heat conditions that occur during the summer impair endurance performances due to increased physiological demands [2].”
Validation of a novel method to quantify local axilla sweating, SweatSENSE
McGill, A., Tinley, E. C., Edwards, S. E., Jamieson, A., Ford, J., Winterton, E., Shardey, J., Hand, R. A., Efstathiou, S., Wemyss, A. M., et al. (2025) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2025.104199 · Cited by 1
A Flexible Wearable Microsystem for Electrochemically Sensing Uric Acid from Sweat
Wang, J., Sun, J., Wang, X., Qiu, B., Han, X., Li, C., & Ding, W. (2025) · Analysis & Sensing · doi:10.1002/anse.202500102 · Cited by 7
Customizable EMG Electrode Integration via 3D Printing
Suppelt, S., Amberg, M. L., Altmann, A. A., Ragg, M. J., Herbst, F., Suppelt, M., Latsch, B., & Kupnik, M. (2025) · IEEE Sensors Letters · doi:10.1109/lsens.2025.3618292 · Cited by 1
A Liquid Crystal Integrated Skin pH Sensing Patch Enabled by Optical Coherence Tomography
Xu, Z., Fang, G., Nie, N., Chen, X., Lin, K., & Chen, Y. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202501574 · Cited by 1
Wearable Sweat Sensors for Personalised Healthcare
Nagarkoti, S. K., Yadav, R., & Bhati, P. (2025) · International Conference on Emerging Trends in Networks and Computer Communications (ETNCC) · doi:10.1109/etncc66224.2025.11299613 · Cited by 2
“Sodium concentration in sweat shows notable variability due to changes in exercise intensity, environmental conditions, and clothing, which affect both sweat rate and composition, even under controlled conditions [55].”
Huang, T., Li, L., Liang, J., Zhu, Z., Yang, Z., & Xi, Y. (2026) · Analytical Methods · doi:10.1039/d5ay01980j · Cited by 1
Marin, E., Bridges, M., Villarini, N. A., Scangarello, G. J., & Henry, C. S. (2026) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2026.118809 · Cited by 4
Bravo‐Sànchez, A., Ramírez-delaCruz, M., Sánchez-Infante, J., Abián, P., & Abián‐Vicén, J. (2026) · Applied Sciences · doi:10.3390/app16062967 · Cited by 1
Goulet, E. D. B., Jeker, D., Claveau, P., Deshayes, T. A., Pancrate, T., Abed, M. E. F., Desroches, A. J., Hoffman, M. D., Gendron, P., Lajoie, C., et al. (2026) · Nutrients · doi:10.3390/nu18060989 · Cited by 1
“Second, heat acclimatization status can influence WBSSC [1]; however, participants were not heat-acclimatized at the time of testing.”
InfluentialDietary assessment of elite orienteering athletes
Machowska-Krupa, W., Cych, P., Demidaś, A., Drehmer, E., Ibáñez, H. E., Zacarés, M., da Silva, V. S., Souza, I., & Silva, D. A. S. (2026) · Scientific Reports · doi:10.1038/s41598-026-45581-3 · Cited by 1
Yang, B., Zhou, M., Wang, Y., Guo, M., Li, Z., & Wang, J. (2026) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2026.104454 · Cited by 1
Lee, J., Moon, J.-H., kim, Y., Kim, H., Kim, E., Lee, H., Yoon, S., Chon, S., Lee, Y., & Park, J. (2026) · Scientific Reports · doi:10.1038/s41598-026-47148-8 · Cited by 3
Flexible printed RTD sensors for wearable temperature monitoring
Retolaza, A., Sotgiu, E., Marques, F., Magalhães, P., Midão, M., Reis, S., Aguiam, D., Alves, F. S., Dias, R. A., & Sousa, P. C. (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.117876 · Cited by 1
Ferrari, A., Ratel, S., Berthoin, S., Garnier, J.-P., & Baquet, G. (2026) · Frontiers in Physiology · doi:10.3389/fphys.2026.1809119 · Cited by 1
“These losses are highly variable, both between and within individuals (Baker, 2017), depending on factors such as exercise intensity (Buono et al., 2008), environmental conditions (Dziedzic et al., 2014), heat acclimation status (Buono et al., 2007), and dietary sodium intake (Allsopp et al., 1998).”
InfluentialUmapathi, K. (2026) · Analytical Methods · doi:10.1039/d6ay00459h · Cited by 2
Reliability and validity of portable sweat sodium analyzers during exercise in the heat
Zhao, X., McKenna, Z., Wierick, S. C., Perez, R. I., Sellner, R. S., Allen, B., & McDermott, B. P. (2026) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2025-0482 · Cited by 2
Xue, Y., Luo, P., Shen, Z., Meng, C., Yao, X., Meng, J., Ren, W., Wang, T., & Zeng, Y. (2026) · Biology · doi:10.3390/biology15131033 · Cited by 1
“This indicates that post-exercise sweat excretion serves not only as the primary means of thermoregulation but also as an important pathway for excreting exercise metabolic byproducts and reflecting metabolic intensity and stress [48].”
Bukhari, A., As’ad, S., Taslim, N. A., Thaiyeb, M., Chrissander, I. Y., & Pramudyo, F. A. (2021) · Science & Sports · doi:10.1016/j.scispo.2020.11.008 · Cited by 3
Roriz, M., Brito, J., Teixeira, F. J., Spyrou, K., & Teixeira, V. H. (2023) · Contemporary Clinical Trials Communications · doi:10.1016/j.conctc.2023.101202 · Cited by 2
“As a consequence of the rise of the SR, the risk of dehydration is significantly increased [6].”
BackgroundGoods, P. S. R., Wall, B. A., Galna, B., McKay, A. K. A., Jennings, D. H., Peeling, P., & Watson, G. (2024) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2023-0159 · Cited by 1
Watkins, Z., McHenry, A., & Heikenfeld, J. C. (2023) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2023_238 · Cited by 2
Novel technical equipment: do these devices keep their promise?
Triska, C., & Mathy, A. (2024) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00424.2024 · Cited by 1
Singh, G., Bennett, K. J. M., McGuigan, H., Goddard, S. G., & Stevens, C. J. (2024) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2024-0095 · Cited by 2
Martínez‐Rodríguez, A., Sánchez‐Sánchez, J., Martínez-Olcina, M., Vicente-Martínez, M., Peñaranda-Moraga, M., Asencio-Mas, N., Gonzálvez-Alvarado, L., Matłosz, P., Sepulveda, R. A. Y., Cortés-Roco, G., et al. (2022) · Nutrients · doi:10.3390/nu15010138 · Cited by 7
“There is no concrete recommendation for sodium intake in female athletes, as there is some degree of interindividual variability, depending on sweat rates and individual sweat sodium concentrations [48].”
BackgroundGoulet, E. D. B., Claveau, P., Simoneau, I. L., Deshayes, T. A., Desroches, A. J., Aloui, F., & Hoffman, M. D. (2023) · Nutrients · doi:10.3390/nu15214500 · Cited by 2
Exercise-induced Sweat Promotes Wound Healing in Diabetic Foot UlcersPreprint
Zhao, M., Tong, Y., Yao, H., Cao, J., Liang, T., Fei, Q., Liang, M., Yang, B., Sun, M., Wang, C., et al. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.04.11.717882 · Cited by 1
“To reduce this bias, following previous recommendations 28,29 , samples were sealed with impermeable Parafilm® M film to improve sample stability and the reliability of analytical results.”
Song, G., Chen, Y., Li, J., Pan, X., Sui, H., Chen, J., Lin, Y., & Yan, Y. (2026) · Frontiers in Nutrition · doi:10.3389/fnut.2026.1923019 · Cited by 1
“Unmonitored urinary excretion during multi-hour training sessions introduces a source of systematic error into body mass loss rate calculations (23, 57), which in turn affects the precision of our session-specific fluid intake guidelines.”
Granger, J. (2019) · Louisiana State University · doi:10.31390/gradschool_theses.4947 · Cited by 1
“Sweat rate is also used to help monitor if athletes are replacing fluid equal to what they loss through sweat during exercise and is used in may sports such as basketball to monitor fluid loss [41, 42].”
BackgroundMethodWang, H. (2020) · Louisiana State University · doi:10.31390/gradschool_dissertations.5263
Evaluation of sensor techniques for detection of contaminants in greywater from showers
Bengtsson, A., & Andersson, K. (2020) · Lund University Publications Student Papers (Lund University)
Cáparra, parada y fonda en la Vía de la Plata
Uceta, A. D. (2003) · La Aventura de la historia
Bukhari, A., As’ád, S., Taslim, N. A., Thaiyeb, M., Chrissander, I. Y., & Pramudyo, F. A. (2020) · Research Square · doi:10.21203/rs.3.rs-40968/v1
Response in a Hot Environment: The Physiological Adaptation of the Sub-elite Para-swimming Athletes
Ashadi, K., Kuncoro, I., Soselisa, R. A., Budiyono, R., Andriana, L. M., & Hasyim, Z. (2022) · Advances in health sciences research/Advances in Health Sciences Research · doi:10.2991/ahsr.k.220106.038
“The effect of exercise in a hot environment is an increase in skin temperature and core body temperature resulting in decreased exercise performance caused by cardiovascular tension and changes in heart and blood vessel function (15).”
BackgroundComportamento da temperatura da pele durante uma meia maratona em ambiente quente sob radiação solar
Júnior, J. F. C. R., Almeida, I. C. D. O., Martins, V. D. A., Cruz, F. R. D. O., dos Reis-Júnior, J. R., Cabido, C. E. T., & de Oliveira, M. N. S. (2021) · Revista Brasileira de Educação Física e Esporte · doi:10.11606/issn.1981-4690.v35i3p43-50
Low-power Wearable Healthcare Sensors
Sherratt, R. S., & Dey, N. (2020) · MDPI eBooks · doi:10.3390/books978-3-03936-480-0
Hashimoto, S., Yamashita, N., Taniguchi, K., & Sugita, M. (2022) · 体力科學 · doi:10.7600/jspfsm.71.333
A post-COVID-19 proposal to apply artificial saliva substitutes to polish the cricket ball
Ferdinands, R. E. D., Fuss, F. K., & Sabnis, K. (2022) · International Journal of Sports Science & Coaching · doi:10.1177/17479541221122388
“…the amount of swing that bowlers were generating since the implementation of an initial temporary ‘ no-saliva ’ ban, 1 the production and composition of perspiration can vary considerably within and among individuals in response to external conditions, 13 making it a less reliable polishing agent.”
Background甘, 善. (2023) · Statistics and Applications · doi:10.12677/sa.2023.122061
Fluorescein or Green Fluorescent Protein: Is It Possible to Create a Sensor for Dehydration?
Joshi, S., Pennycook, L., & Ismail, Y. (2019) · Journal of Emerging Investigators · doi:10.59720/19-040
“Excessive sweating is one of the causes of dehydration, and can be triggered by both exercise and heat (3).”
BackgroundMallari, M. F. T., Santos, L. A. G., Callanta, H. P., Papa, E. L. V., & Valleser, C. W. (2024) · International journal of human movement and sports sciences · doi:10.13189/saj.2024.120315
“Sweat patches (Tegaderm +Pad 3586, 3M) were then applied to their thigh [12-14].”
Peel, J. (2024) · Cronfa (Swansea University) · doi:10.23889/suthesis.66881
Skin-derived biofluid sampling for analytical approaches
Sekine, Y., & Oikawa, D. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15978-7.00034-5 · Cited by 2
Physiological and Nutritional Considerations for Elite Squash: A Systematic Review
Turner, O., Mitchell, N., Ruddock, A. D., Purvis, A. J., & Ranchordas, M. K. (2024) · Journal of Science in Sport and Exercise · doi:10.1007/s42978-024-00313-9
Wearable Sweat Sensors: A Review
Chowdhury, I., Ali, M. Y., & Howlader, M. M. R. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95478-5.00015-7 · Cited by 2
Ahmadi, M. M., Gheybizadeh, M. R., Yousefi, M., & Daryabor, A. (2024) · Majallah-i dānishgāh-i ̒ulum-i pizishkī-i Kirmān. · doi:10.34172/jkmu.2024.35 · Cited by 1
“The simplest and most accurate method to assess whole-body sweating rate is via changes in body mass during exercise (17).”
Real-Time Prediction of Panic Attacks Through Sweat Analysis in Wearable Devices
Sriram, S., Majumder, S., Mimansa, Nivethitha, V., Saxena, A., & Thangavel, M. (2024) · IEEE International Conference for Women in Computing (InCoWoCo) · doi:10.1109/incowoco64194.2024.10863169
“The sweat level S lvl may increase to around 10 liters[13] during the massive physiological response such as a panic attack which may imply that the person experiencing it is induces stress and posses some underlying health problems.”
Nelson, R. S., Grossman, M. G., Klug, Z. M., Calamari, M., Donayre, A., Cybulski, T. R., Schooley, J., Griffith, G., Corcos, D. M., Wright, D. E., et al. (2025) · medRxiv · doi:10.1101/2025.03.05.25323327
Explaining Representations in Correlation-based Deep Multiview Representation Learning
Kuschel, M., Alkhatib, A., Hasija, T., & Boström, H. (2025) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp49660.2025.10888309
“Movement leads to a change in accelerometry values, increased body temperature, and higher sweat activity [20], [21].”
Piedade, S. R., Beck, L. A. D. S., & Ferreira, D. M. (2025) · Springer eBooks · doi:10.1007/978-3-031-84493-5_2
Aluko, E. O., Etim, M. E., Azunobi, F. J., Robinson, E.-A. U., & Ekpenyong, U. E. (2025) · Cardiovascular & Haematological Disorders - Drug Targets · doi:10.2174/011871529x369260250512024353
Zhang, J., Chen, Y., Zhao, X., Li, X., Wen, W., Wu, W., Zou, M., & Qiu, J. (2025) · Frontiers in Nutrition · doi:10.3389/fnut.2025.1621966 · Cited by 3
Training Considerations for the Bodybuilding Peak Week
Stevenson, S. W. (2025) · Strength and conditioning journal · doi:10.1519/ssc.0000000000000938
Integrating Wearable Sensor Data and Neural Networks for Real-Time Electrolyte Prediction
Kumar, D. (2025) · Biomedical Materials & Devices · doi:10.1007/s44174-025-00524-w
Investigation of achieving active sweat release using the ultrasonic atomization technique
Lien, H.-W., Shi, Q.-W., Chang, E.-H., Lin, C. H., & Huang, C. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.117291
Nunes, M. J., Cordas, C. M., Moura, J. J. G., Noronha, J. P., & Branco, L. C. (2021) · Figshare · doi:10.6084/m9.figshare.13632861
Mary, X. A., Ashisha, G. R., Bhagavathsingh, J., Manimegalai, P., Karthik, C., & Salau, A. O. (2026) · Hybrid Advances · doi:10.1016/j.hybadv.2026.100603
Can We Protect Our Hearts by Sweating Out Excess Sodium?
Hoch, J. W., & Watso, J. C. (2026) · Exercise and Sport Sciences Reviews · doi:10.1249/jes.0000000000000383
Participation à l'étude du rôle du système adénosinergique en pathologie cardiovasculaire
Vairo, D. (2018) · theses.fr (ABES) · doi:10.70675/80125e1dze909z48c7z92afz5ec81b88db71
The maturation of regional sweating patterns from childhood to young adulthood in females
Blount, H., Esteves, N. K., Ward, J., Simmons, G. H., Worsley, P. R., & Filingeri, D. (2026) · Experimental Physiology · doi:10.1113/ep093788
“However, this approach does not fully eliminate maturation-related differences in metabolic heat production or sudomotor drive which may persist due to differences in lean body mass, muscle composition, and neural factors (Baker, 2017; Hu et al., 2018).”
Fernández-Elías, V. E., Flores-Bonilla, N., Torres, O. L., & Burgos-Postigo, S. (2026) · Applied Sciences · doi:10.3390/app16083912
Liu, S., Ni, K., Ren, Q., Wang, Z., Zhang, C., Wang, J., Zhao, J., Li, X., & Liu, R. (2026) · Nano Energy · doi:10.1016/j.nanoen.2026.111989
Wang, W., Zhou, R., He, G., Si, Y., Cao, Y., Zheng, P., & Zi, W. (2026) · Frontiers in Physiology · doi:10.3389/fphys.2026.1807399
“Concurrently, fl uid and electrolyte losses through sweating and sodium excretion may reduce plasma volume and alter neurohumoral regulation, thereby exacerbating cardiovascular strain (Shirreffs and Sawka, 2011; Baker, 2017; Baker et al., 2022; Anastasiou et al., 2009).”
Bichet, D. G. (2026) · Elsevier eBooks · doi:10.1016/b978-0-12-815389-5.00016-2
Aerosol jet and 3D printed impedance-based wearable sensors for local sweating rate monitoring
Dong, K., Wen, H., Huang, F., Gao, Z., Cao, Y., Xu, X., Ye, Q., & Liu, Q. (2026) · Microchemical Journal · doi:10.1016/j.microc.2026.118496
Exercise-induced sweat suppresses depression-like behaviors in micePreprint
Yao, H., Xing, S., Liang, M., Fei, Q., Cao, J., Liang, T., Yang, B., Cui, C., Liu, H., & Cui, Q. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.06.02.728455
Liu, H., & Lin, W. (2026) · Analytical Methods · doi:10.1039/d6ay00936k
Validity and Reliability of At-Home Sweat Rate and Sodium Patches
Atkins, W. C., Chopelas, A., & McDermott, B. P. (2026) · Translational Journal of the American College of Sports Medicine · doi:10.1249/tjx.0000000000000381
Mid-infrared wearable biosensing for metabolic syndrome: Opportunities and translational challenges
Androutsos, L., Birngruber, T., Campia, I., Escacena, N., Floares, A., Floares, C., Hahne, N., Kischkat, J. F., Mohsin, M., Naseer, S., et al. (2026) · iScience · doi:10.1016/j.isci.2026.116633
“50 Furthermore, individual differences in skin elasticity, compliance, and microcirculation may modulate sensor-skin contact and signal quality, thus highlighting the need for adaptive and flexible sensor design.”
Ion-exchange gold nanopore membranes for potentiometric “total ion concentration” sensing
Solymosi, G. T., Karácsony, R. Z., & Gyurcsányi, R. E. (2026) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2026.140482
Lian, C., Li, M., Fenech‐Salerno, B., Martins, T. S., Wu, S., Holicky, M., Oliveira, O. N., Cass, A. E. G., & Torrisi, F. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.119057
Alshuwaier, G. O. (2026) · Metabolites · doi:10.3390/metabo16080548
“The analytes of greatest practical interest, the electrolytes, are lost in substantial quantities in sweat [2,18,19] and are subject to tight, hormonally driven renal regulation that need not parallel the handling of creatinine [20]; indeed, established equations that estimate daily sodium…”
Applications of Wearable Sweat Biosensors in Sports Activities with Real-World Cases
Yan, J., Shi, J., Zhang, Z., Yang, M., Zhang, M., & Wang, M. (2026) · Bioengineering · doi:10.3390/bioengineering13080906
“Typical concentrations during exercise vary by individual factors, sweat rate, and environment: Na + and Cl − often range within 10–90 mmol/L, K + within 2–10 mmol/L (typically stable at ~2–8 mmol/L, similar to plasma), and Ca 2+ within 0.3–2 mmol/L [4,16,47].”
InfluentialRehman, K., & Akash, M. S. H. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-45911-5.00006-4 · Cited by 1
Hourani, A. A., Patel, R. K., Coakley, S. L., & McIntyre, R. D. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.7320260
Wierick, S. C., McKenna, Z. J., Perez, R. I., Zhao, X., Sellner, R. S., Allen, B. M., & McDermott, B. P. (2026) · European Journal of Applied Physiology · doi:10.1007/s00421-026-06409-0
Similar sweat sodium profiles across soccer, handball, and distance running athletes in Cameroon
Ndemba, P. B. A., Mbouh, S., Nganou-Gnindjio, C. N., Ndongo, J. M., Fadimatou, I., Lafaye, C., Saubade, M., Lele, E. C. B., Menanga, A. P., Wandji, B. K., et al. (2026) · Temperature · doi:10.1080/23328940.2026.2717075
Kuna, D., Kljusurić, J. G., & Bosanac, V. (2026) · Sports · doi:10.3390/sports14090381
“Appropriate exercise-related hydration requirements depend on exercise duration and intensity, sweat rate, sweat sodium concentration, environmental conditions, acclimatization status, clothing and equipment, and opportunities to drink [1,6,7,29].”
Mehta, Y., Hasan, M. R., Sharma, R., Giri, Y., & Narang, J. (2026) · ACS Applied Bio Materials · doi:10.1021/acsabm.6c00654
Cheng, X., Tang, Y., & Xu, Z. (2026) · Reviews in Analytical Chemistry · doi:10.1515/revac-2025-0103
“…validity parameters rather than secondary metadata; recent synthesis work emphasizes that concentration-only reporting is frequently nonidenti fi able without a sweat-rate term and that cross-study comparison is often invalid unless collection methodology is harmonized or explicitly corrected [104].”
Xue, T., Lin, W., Zhou, J., Luo, C., Li, B., Zhang, X., Chen, C.-J., Liu, J., & Zhu, G. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01436-5
“In particular, sweat Na ⁺ concentration and sweat rate can be combined to estimate sweat Na ⁺ loss and fl uid loss, which is important for guiding fl uid/electrolyte replacement during exercise 24 .”
Habeahan, N. P., Gaol, J. R. L., Sigalingging, E., Manalu, N., & Martua, A. (2026) · COMPETITOR Jurnal Pendidikan Kepelatihan Olahraga · doi:10.67322/cpjok.v18i3.984
Shitanda, I., Fujisawa, T., Loew, N., Shirai, R., Imade, Y., OKAMOTO, Y., Yanagita, S., Watanabe, H., & Itagaki, M. (2026) · ACS Omega · doi:10.1021/acsomega.6c04240
Egzersizde Enerji Sistemleri ve Metabolik Uyum Mekanizmaları
Çiydem, Ç. (2026) · Özgür Yayınları eBooks · doi:10.58830/ozgur.pub1419.c5733
Qi, Q., Duan, J., Lei, Y., Zhou, S., Liu, Q. S., Wang, Q., Gao, N., Sun, W., Zhan, Z., & Wu, Y. (2026) · Biosensors · doi:10.3390/bios16090523
“Sweat secretion rate varies continuously with exercise intensity [4], thermoregulatory responses, environmental conditions, and fluid intake, while stretching, bending, compression, and friction at the skin surface can continuously disturb sweat collection and transport [34].”
InfluentialCao, M., Yu, S., Yuan, S., Yang, Y., Zhang, H., Song, J., Yan, X., Liu, J., Wang, Y., Li, W., et al. (2026) · Science China Materials · doi:10.1007/s40843-026-4333-8
Smart Textile Systems as Dynamic Platform for Human Hydration Monitoring
Zou, X., Zhang, Y., Forrester, S., & Xu, L. (2026) · Biomedical Materials & Devices · doi:10.1007/s44174-026-00780-4
Salt- and Temperature-Responsive Poly(ethyleneimine)/Phenylthioacetic Acid Ion-Pair Assemblies
Hwang, J. S., Long, W., & Kim, J. (2026) · Digest Journal of Nanomaterials and Biostructures · doi:10.31083/djnb52488
Xin, Z., Gao, M., Wu, X., See, M., Cheng, P., & Yan, Y. (2026) · Nutrients · doi:10.3390/nu18193267
Nutrition, Hydration, and Recovery: Optimizing Performance
Ketterly, J., Mandel, C., Hueglin, S., Baker, L., Lozano, J. M. O., Murray, T., King, K., Nguyen, D., Mack, R., & Wittstein, J. R. (2026) · Operative Techniques in Sports Medicine · doi:10.1016/j.otsm.2026.151289
Self-citationNighttime Sweating-Related Sleep Disturbance in Swiss Elite Athletes
Kater, M., Erlacher, D., Schmid, M. J., & Vorster, A. (2026) · Sleep Epidemiology · doi:10.1016/j.sleepe.2026.100180
Pingitore, A., Amatori, S., Nusca, S. M., Rocco, V., Lazau, S. V., Peruzzi, M., Frati, G., Sciarra, L., Cavarretta, E., & Perroni, F. (2026) · The Open Sports Sciences Journal · doi:10.2174/011875399x505344261007060521
A flexible microfluidic flow sensor for the continuous monitoring of sweat rate
Gao, Y., Li, H., Cheng, J., WeiMing, T., Zhang, Y., Zhang, M., Zhang, H., Zhou, J., Zhang, J., Zhao, Y., et al. (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.118648
XiaoTian, H., Wook, Y., Zhang, S., & LiFang, J. (2026) · Frontiers in Physiology · doi:10.3389/fphys.2026.2002403
Sabou, V., Macrae, H. Z., Mulholland, K., Webber, D., Brown, L. R., Randell, R. K., Tarnowski, C. A., James, L., & Rollo, I. (2026) · Nutrients · doi:10.3390/nu18203459
“Despite this, best practices of sweat collection (clean skin, avoiding patch saturation, gloves, etc.) described by Baker [37] were followed.”
Setiawan, P. A., Sa’adah, U., Hardiansyah, F. F., Aziz, A. S., Nailussa’ada, N., Permatasari, D. I., Yunanto, A. A., & Martono, H. Y. (2026) · International Seminar on Application for Technology of Information and Communication (iSemantic) · doi:10.1109/isemantic71495.2026.11742765
“EFSA provides population-level adequate total-water intake values rather than per-kilogram prescriptions [8], while exercise guidance recommends individualized replacement based on measured sweat loss [3], [4], [5].”
Influential
Metadata
- Authors
- Baker, L. B.
- Affiliations
- Gatorade Sports Science Institute (US)
- Corresponding author
- Baker, Lindsay B.
- ORCID
- Baker, Lindsay B.
- Venue
- Sports Medicine
- Published
- 2017-03
- Volume
- 47
- Issue
- S1
- Pages
- 111-128
- ISSN
- 0112-1642 (ISSN-L)
- 1179-2035
- PMC
- PMC5371639
- OpenAlex
- W2597545654
- Cited by
- 403
- References
- 233
- Citations by year
- 2026: 66 · 2025: 53 · 2024: 46 · 2023: 48 · 2022: 45 · 2021: 47 · 2020: 47 · 2019: 27 · 2018: 18 · 2017: 5
- FWCI
- 3.25
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Sports Medicine (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- PepsiCo
- Gran Sasso Science Institute
- Topics
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- sweat rate, sweat sodium concentration, sweat test, within-person variability, interindividual variability, fluid and electrolyte replacement, thermoregulatory sweating, weight change, heat acclimation, exercise intensity, hydration status, athletes
- MeSH terms
- Humans, Sodium, Sports, Sweat, Sweating, Water-Electrolyte Balance, Exercise, Athletes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.