Sweating Rate and Sweat Sodium Concentration in Athletes: A Review of Methodology and Intra/Interindividual Variability
Open accessThe DOI matches its Crossref record; 233 of the 233 references it cites were found in a registry or an index.
Abstract
Athletes lose water and electrolytes as a consequence of thermoregulatory sweating during exercise and it is well known that the rate and composition of sweat loss can vary considerably within and among individuals. Many scientists and practitioners conduct sweat tests to determine sweat water and electrolyte losses of athletes during practice and competition. The information gleaned from sweat testing is often used to guide personalized fluid and electrolyte replacement recommendations for athletes; however, unstandardized methodological practices and challenging field conditions can produce inconsistent/inaccurate results. The primary objective of this paper is to provide a review of the literature regarding the effect of laboratory and field sweat-testing methodological variations on sweating rate (SR) and sweat composition (primarily sodium concentration [Na + ]). The simplest and most accurate method to assess whole-body SR is via changes in body mass during exercise; however, potential confounding factors to consider are non-sweat sources of mass change and trapped sweat in clothing. In addition, variability in sweat [Na + ] can result from differences in the type of collection system used (whole body or localized), the timing/duration of sweat collection, skin cleaning procedure, sample storage/handling, and analytical technique. Another aim of this paper is to briefly review factors that may impact intra/interindividual variability in SR and sweat [Na + ] during exercise, including exercise intensity, environmental conditions, heat acclimation, aerobic capacity, body size/composition, wearing of protective equipment, sex, maturation, aging, diet, and/or hydration status. In summary, sweat testing can be a useful tool to estimate athletes’ SR and sweat Na + loss to help guide fluid/electrolyte replacement strategies, provided that data are collected, analyzed, and interpreted appropriately.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Fig. 1 Frequency histograms of (a) absolute whole-body sweating rate and (b) relative whole-body sweating rate from 461 athletes (327 adults, 134 youth; 369 male, 92 female) of various sports (e.g. American Football, basketball, baseball, soccer, tennis, and endurance) tested during training or competition in various environmental conditions (15–50 °C, 20–79% relative humidity). The vertical line represents the mean value. Reproduced from Baker et al. [96], with permission](https://figures.cochat.ai/paper-figures/0c406296f9324ce4a1009eef5abc81cb/sweating-rate-and-sweat-sodium-concentration-in-athletes-a-review-of-methodology-figure-1.jpg)
![Fig. 2 Frequency histograms of (a) forearm sweat sodium concentration ([Na+]) using the absorbent patch technique and (b) predicted whole-body sweat [Na+] from 506 athletes (367 adults, 139 youth; 404 male, 102 female) of various sports (e.g. American Football, basketball, baseball, soccer, tennis, and endurance) tested during training or competition in various environmental conditions (15–50 °C, 20–79% relative humidity). The vertical line represents the mean value. Reproduced from Baker et al. [96], with permission](https://figures.cochat.ai/paper-figures/c9cba02b8bb04a6a9f0c3d59a3cc51d2/sweating-rate-and-sweat-sodium-concentration-in-athletes-a-review-of-methodology-figure-2.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Since sweat composition is modulated by a variety of factors including age, body mass, diet, and hydration status (46)”
From Regional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat (2019) · cites this paper as [46]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“a wide range of analytical techniques have been used by scientists and practitioners to measure sweat composition”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Baker 2017
The cited source says what the claim attributes to it.
In the citing paper
“Nonetheless, final sweat typically has a [K+] similar, albeit with a slightly broader range (~2–8 mmol/L), to that reported for blood plasma.29,41,42”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [29]
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“These findings agree with previous investigations of exercise sweat (21, 46, 47).”
From Regional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat (2019) · cites this paper as [46]
Experimental — accuracy not yet measuredIn the citing paper
“However, the current mechanism of potassium ion secretion in sweat is still uncertain, so the final potassium concentration in sweat may be maintained within the plasma potassium concentration range 76 .”
From A review of sampling, energy supply and intelligent monitoring for long-term sweat sensors (2022) · cites this paper as [76]
3 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · Applied Ergonomics · doi:10.1016/0003-6870(92)90318-p · Cited by 5,737
Webb, A. K. (2006) · Cited by 4,369
ACSM Position Stand: Exercise and Fluid Replacement
Convertino, V. A., Armstrong, L. E., Coyle, E. F., Mack, G. W., Sawka, M. N., Senay, L. C., & Sherman, W. M. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199610000-00045 · Cited by 1,965
Gibson, L. E., & Cooke, R. E. (1959) · Pediatrics · doi:10.1542/peds.23.3.545 · Cited by 1,434 · cited 2×
“Pilocarpine iontophoresis was standardized by Gibson and Cooke in 1959 (Quantitative Pilocarpine Iontophoretic Test [or QPIT] method [89]).”
MethodRowe, S. M., Miller, S., & Sorscher, E. J. (2005) · New England Journal of Medicine · doi:10.1056/nejmra043184 · Cited by 1,398
Balance of carbohydrate and lipid utilization during exercise: the "crossover" concept
Brooks, G. A., & Mercier, J. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.76.6.2253 · Cited by 862 · cited 1×
“In addition, the following papers provide equations to calculate mass loss from substrate oxidation [79, 85, 86] and respiratory water [79, 85].”
BackgroundBiology of sweat glands and their disorders. I. Normal sweat gland function
Sato, K., Kang, W. H., Saga, K., & Sato, K. T. (1989) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(89)70063-3 · Cited by 717 · cited 2×
“More details on the structure, function, and control of eccrine sweat glands can be found in several comprehensive reviews [19, 26, 29, 32, 44, 57].”
BackgroundAssessing Hydration Status: The Elusive Gold Standard
Armstrong, L. E. (2007) · Journal of the American College of Nutrition · doi:10.1080/07315724.2007.10719661 · Cited by 643 · cited 1×
“The simplest and most accurate method to assess WBSR is via changes in nude body mass from before to after exercise [2, 4, 78]; however, corrections for non-sweat sources of body mass change should be considered.”
MethodInvited Review: Aging and human temperature regulation
Kenney, W. L., & Munce, T. A. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00202.2003 · Cited by 577
Robinson, S., & Robinson, A. H. (1954) · Physiological Reviews · doi:10.1152/physrev.1954.34.2.202 · Cited by 514 · cited 4×
“Regarding the impact of sweat stimulation methodology on sweat composition, two studies have shown higher [Na] and [Cl] with exercise versus passive heating [98, 104].”
BackgroundInfluential
Research works printed but not linked: 5
- Kuno Y Human perspiration 1956 Springfield Charles C. Thomas Publisher
- Berne RM Levy MN Physiology 1998 St. Louis Mosby
- Ogata K Functional variations in human sweat glands, with remarks upon the regional difference of the amount of sweat J Orient Med 1935 23 98 101
- Yoshimura H Acclimatization to heat and cold. Essential problems in climatic physiology 1960 Kyoto Nankodo
- Candas V Dejours P Adaptation to extreme environments. Thermophysiological changes in man during humid heat acclimation Comparative physiology of environmental adaptations 1987 Basel Karger 76 93
Cited by
Items 101–200 of 402
McCubbin, A. J., Cox, G. R., & Costa, R. J. S. (2019) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2018-0270 · Cited by 31
“Considering sodium is the most abundant electrolyte present in 27 sweat, prolonged heavy sweating can cause significant sodium losses (Baker, 2017).”
BackgroundSerag, A., Shakkour, Z., Halboup, A. M., Kobeissy, F. H., & Farag, M. A. (2021) · Journal of Proteomics · doi:10.1016/j.jprot.2021.104310 · Cited by 34
Suppiah, H. T., Ng, E. L., Wee, J., Taim, B. C., Huynh, M., Gastin, P. B., Chia, M., Low, C. Y., & Lee, J. K. W. (2021) · Nutrients · doi:10.3390/nu13114073 · Cited by 31
McCubbin, A. J., Lopez, M. B., Cox, G. R., Caldwell Odgers, J. N., & Costa, R. J. S. (2019) · European Journal of Applied Physiology · doi:10.1007/s00421-019-04199-2 · Cited by 30
“Patches were removed with steel forceps that were pre-rinsed with deionized water and dried with clean laboratory wipes, when approximately 25% of the patch was visibly soaked with sweat, to prevent altered sample composition due to hidromeiosis (Baker 2017).”
MethodResultInfluentialSweat analysis with a wearable sensing platform based on laser-induced graphene
Vivaldi, F. M., Dallinger, A., Poma, N. V., Bonini, A., Biagini, D., Salvo, P., Borghi, F., Tavanti, A., Greco, F., & Francesco, F. D. (2022) · APL Bioengineering · doi:10.1063/5.0093301 · Cited by 36
Kocur, M., Bogon, J., Mayer, M., Witte, M., Karber, A., Henze, N., & Schwind, V. (2022) · ACM Symposium on Virtual Reality Software and Technology (VRST) · doi:10.1145/3562939.3565628 · Cited by 38
“with techniques from sports medicine, we determined participants’ sweating rate using absorbent dressings attached on the skin to analyze participants’ sweating response as an indicator for physical activity and effort [5, 29].”
MethodCMOS Interfaces for Internet-of-Wearables Electrochemical Sensors: Trends and Challenges
Dei, M., Aymerich, J., Piotto, M., Bruschi, P., del Campo, F. J., & Serra-Graells, F. (2019) · Electronics · doi:10.3390/electronics8020150 · Cited by 31
The physiology of impenetrable skin: Colossus of the X-Men
Fitzgerald, B. W. (2018) · AJP Advances in Physiology Education · doi:10.1152/advan.00107.2018 · Cited by 32
Fluid type influences acute hydration and muscle performance recovery in human subjects
Harris, P. R., Keen, D. A., Constantopoulos, E., Weninger, S. N., Hines, E. R., Koppinger, M. P., Khalpey, Z. I., & Konhilas, J. P. (2019) · Journal of the International Society of Sports Nutrition · doi:10.1186/s12970-019-0282-y · Cited by 43
Dry sweat as sample for metabolomics analysis
Delgado‐Povedano, M. D. M., Castillo-Peinado, L. S., Calderón-Santiago, M., de Castro, M. D. L., & Priego‐Capote, F. (2019) · Talanta · doi:10.1016/j.talanta.2019.120428 · Cited by 27
Hauke, A., Oertel, S., Knoke, L., Fein, V., Maier, C., Brinkmann, F., & Jank, M. P. M. (2020) · Biosensors · doi:10.3390/bios10090123 · Cited by 32
Nutritional optimization for female elite football players—topical review
de Sousa, M. V., Lundsgaard, A., Christensen, P. M., Christensen, L., Randers, M. B., Mohr, M., Nybo, L., Kiens, B., & Fritzen, A. M. (2022) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.14102 · Cited by 28
Excretion of Ni, Pb, Cu, As, and Hg in Sweat under Two Sweating Conditions
Kuan, W., Chen, Y., & Liu, C. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19074323 · Cited by 28
Ricci, A., Evans, C., Stull, C., Peacock, C. A., French, D. N., Stout, J. R., Fukuda, D. H., Bounty, P. L., Kalman, D., Galpin, A. J., et al. (2025) · Journal of the International Society of Sports Nutrition · doi:10.1080/15502783.2025.2467909 · Cited by 54
Effects of heat exposure on the thermoregulatory responses of young children
Tsuzuki, K. (2022) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2023.103507 · Cited by 31
Garrett, D. C., & Fear, E. C. (2019) · IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2019.2911849 · Cited by 30
“This is particularly true for exercising athletes, where water is lost predominantly through evaporation (pure water) and sweat (15–30% the osmolality of blood) [34].”
BackgroundLi, J., Yang, X., Zhang, Z., Xiao, H., Sun, W., Huang, W., Li, Y., Chen, C., & Sun, Y. P. (2020) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2020.123614 · Cited by 27
Surapongchai, J., Saengsirisuwan, V., Rollo, I., Randell, R. K., Nithitsuttibuta, K., Sainiyom, P., Leow, C. H. W., & Lee, J. K. W. (2021) · Nutrients · doi:10.3390/nu13041374 · Cited by 23
“The analysis of sweat [K+] in the present provided a quality control for the analysis of sweat samples [15].”
BackgroundAdvanced Microfluidic‐Based Wearable Electrochemical Sensors for Continuous Biochemical Monitoring
Park, S., Kim, S., Lee, S.-J., Tsukruk, V. V., Park, S., & Lim, H. (2025) · Advanced Electronic Materials · doi:10.1002/aelm.202500010 · Cited by 31
Rao, L. T., Mandal, C. K., & Patolsky, F. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202503096 · Cited by 45
Lin, P.-H., Chang, W.-L., Sheu, S.-C., & Li, B. (2020) · iScience · doi:10.1016/j.isci.2020.101658 · Cited by 24
“transporting the sweat to the surface of the skin (Baker, 2017; Baker, 2019; Christopher H. Gibbons, 2012; Sato et al., 1989).”
BackgroundMethodInfluentialSkin‐Interfaced Bifluidic Paper‐Based Device for Quantitative Sweat Analysis
Deng, M., Li, X., Song, K., Yang, H., Wei, W., Duan, X., Ouyang, X., Cheng, H., & Wang, X. (2023) · Advanced Science · doi:10.1002/advs.202306023 · Cited by 28
Rovira, M., Lafaye, C., Demuru, S., Kunnel, B. P., Aymerich, J., Cuenca, J., Serra-Graells, F., Margarit, J. M., Haque, R. I., Saubade, M., et al. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116560 · Cited by 28
Mosquito taste responses to human and floral cues guide biting and feeding
Baik, L. S., Talross, G. J. S., Gray, S., Pattisam, H. S., Peterson, T. N., Nidetz, J. E., Hol, F. J. H., & Carlson, J. R. (2024) · Nature · doi:10.1038/s41586-024-08047-y · Cited by 27
“A wide array of taste cues found on human skin and in sweat, all essentially non-volatile, were tested at levels that approximate those in human sweat 23,26,27 .”
New wicking measurement system to mimic human sweating phenomena with continuous microfluidic flow
Kim, H. S., Michielsen, S., & DenHartog, E. (2020) · Journal of Materials Science · doi:10.1007/s10853-020-04543-4 · Cited by 23
Role of Wearables in Sports based on Activity recognition and biometric parameters: A Survey
Nithya, N. S., & Nallavan, G. (2021) · International Conference on Artificial Intelligence and Smart Energy (ICAIS) · doi:10.1109/icais50930.2021.9395761 · Cited by 29
“The information derived from sweat guide the players to very well maintain their body bio fluids and electrolyte concentration so that hypo and hyper hydration is prevented [32].”
BackgroundIncidence of Hyponatremia During a Continuous 246-km Ultramarathon Running Race
Seal, A., Anastasiou, C. A., Skenderi, K., Echegaray, M., Yiannakouris, N., Tsekouras, Y. E., Matalas, A., Yannakoulia, M., Pechlivani, F., & Kavouras, S. A. (2019) · Frontiers in Nutrition · doi:10.3389/fnut.2019.00161 · Cited by 29
Performance of Polymeric Skin Adhesives during Perspiration
Hansen, D. A., Moghaddam, S. Z., Eiler, J., Hansen, K., & Thormann, E. (2020) · ACS Applied Polymer Materials · doi:10.1021/acsapm.9b01214 · Cited by 27
Benjamin, C. L., Sekiguchi, Y., Morrissey, M. C., Butler, C. R., Filep, E. M., Stearns, R. L., & Casa, D. J. (2021) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2021.05.013 · Cited by 31
Passively Addressable Ultra-Low Volume Sweat Chloride Sensor
Ganguly, A., & Prasad, S. (2019) · Sensors · doi:10.3390/s19204590 · Cited by 23
“One of the electrolytic biomarkers in sweat that can be tracked to quantify hydration levels is chloride [9,10].”
BackgroundHuman Sweat Analysis Using a Portable Device Based on a Screen‐printed Electrolyte Sensor
Hauke, A., Oertel, S., Jank, M. P. M., Frey, L., Langenstein, B., & Bertsch, T. (2017) · Electroanalysis · doi:10.1002/elan.201700672 · Cited by 24
Bioinspired Microtexturing for Enhanced Sweat Adhesion in Ion-Selective Membranes
Marques, M. J. M., Masuji, T., Adel, M., El-Bab, A. M. R. F., Hirose, K., Uchida, K., Sugime, H., & Umezu, S. (2025) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0337 · Cited by 36
“Sodium concentration in sweat has been shown to be a key indicator of hydration and muscle performance, as highlighted by Baker [ 12 ].”
Ohashi, T., Gerrett, N., Shinkawa, S., Satō, T., Miyake, R., Kondo, N., & Mitsuzawa, S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c03466 · Cited by 23
Electrowetting valves for sweat-based microfluidics
Naik, A. R., Warren, B., Burns, A., Lenigk, R., Morse, J. D., Alizadeh, A., & Watkins, J. J. (2021) · Microfluidics and Nanofluidics · doi:10.1007/s10404-020-02403-w · Cited by 22
Analytical assessment of sodium ISFET based sensors for sweat analysis
Rovira, M., Lafaye, C., Wang, S., Fernández‐Sánchez, C., Saubade, M., Liu, S., & Jiménez‐Jorquera, C. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.134135 · Cited by 22
Sekiguchi, Y., Adams, W. M., Curtis, R. M., Benjamin, C. L., & Casa, D. J. (2019) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2018.12.005 · Cited by 21
Steijlen, A. S. M., Bastemeijer, J., Groen, P., Jansen, K. M. B., French, P. J., & Bossche, A. (2020) · Analytical Methods · doi:10.1039/d0ay02014a · Cited by 21
Relf, R., Willmott, A., Flint, M. S., Beale, L., & Maxwell, N. (2019) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2018.12.019 · Cited by 19
“The TA method requires 20-minutes of steady-state exercise and sweating for accurate correlative analysis (Baker, 2017), and is a reliable, practical and cost-effective alternative.”
BackgroundMethodResultInfluentialRamanathan, S., Jusoh, M., Sabapathy, T., Yasin, M. N. M., Gopinath, S. C. B., ARahim, H., Osman, M. N., & Wahab, Y. A. (2020) · Applied Physics A · doi:10.1007/s00339-020-03933-4 · Cited by 20
Fluid Balance and Carbohydrate Intake of Elite Female Soccer Players during Training and Competition
Tarnowski, C. A., Rollo, I., Carter, J. M., Lizarraga-Dallo, M. A., Oliva, M. P., Clifford, T., James, L. J., & Randell, R. K. (2022) · Nutrients · doi:10.3390/nu14153188 · Cited by 24
“Secondly, potassium concentrations were not analyzed in sweat, which is useful for quality control for sweat samples [42].”
BackgroundInfluentialThe interstitial compartment as a therapeutic target in heart failure
Aronson, D. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.933384 · Cited by 21
“Chloride is passively reabsorbed via the cystic fibrosis transmembrane conductance regulator (CFTR) on the luminal and basolateral ductal cell membrane (143, 144).”
BackgroundSweat Analysis-Based Fatigue Monitoring during Construction Rebar Bending Tasks
Ma, J., Li, H., Yu, X., Fang, X., Fang, B., Zhao, Z., Huang, X., Anwer, S., & Xing, X. (2023) · Journal of Construction Engineering and Management · doi:10.1061/jcemd4.coeng-13233 · Cited by 21
Ma, J., Li, H., Anwer, S., Umer, W., Antwi‐Afari, M. F., & Xiao, E. B. (2024) · International Journal of Occupational Safety and Ergonomics · doi:10.1080/10803548.2024.2330242 · Cited by 21
Feasibility Study of Hydration Monitoring Using Microwaves–Part 2: Measurements of Athletes
Garrett, D. C., Fletcher, J. R., Hogan, D. B., Fung, T. S., & Fear, E. C. (2019) · IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2019.2911909 · Cited by 20
“PHYSICAL exercise can lead to substantial water loss from sweating and evaporation [1].”
BackgroundNair, R. R. (2020) · Flexible and Printed Electronics · doi:10.1088/2058-8585/abc9c9 · Cited by 19
A Case-Series Observation of Sweat Rate Variability in Endurance-Trained Athletes
Smith, J. W., Bello, M. L., & Price, F. G. (2021) · Nutrients · doi:10.3390/nu13061807 · Cited by 25
“In environments with higher humidity, sweat rates can be elevated significantly without fully corresponding to estimated metabolic heat production due to reductions in evaporative cooling as a result of moisture in the air [28].”
BackgroundA multifunctional wearable patch based on hydrogel for strain sensing and epidermal sweat-analyzing
Wu, S., Lu, J., Gao, H., Yang, Y., He, N., Miao, G., & Xu, L. (2025) · Chemical Engineering Journal · doi:10.1016/j.cej.2025.166828 · Cited by 23
Li, J., Dong, J., Huang, Y., Su, J., Xie, Y. F., Wu, Y., Tang, W., Li, Y., Huang, W., & Chen, C. (2022) · Environmental Science & Technology · doi:10.1021/acs.est.2c05237 · Cited by 21
Enhancing Sweat Rate Using a Novel Device for the Treatment of Congestion in Heart Failure
Aronson, D., Nitzan, Y., Petcherski, S., Bravo, E., Habib, M., Burkhoff, D., & Abraham, W. T. (2022) · Circulation Heart Failure · doi:10.1161/circheartfailure.122.009787 · Cited by 21
Hua, Y., Guan, M., Xia, L., Chen, Y., Mai, J., Zhao, C., & Liao, C. (2023) · Biosensors · doi:10.3390/bios13030409 · Cited by 23
“The production of sweat can be accomplished through physical activity, body heating, pressure or ionization energy stimulation [1].”
BackgroundLi, B., Sui, N., Li, M., Gu, W., Yang, W., Xu, W., & Zhao, J. (2024) · Talanta · doi:10.1016/j.talanta.2024.126285 · Cited by 18
Varillas‐Delgado, D. (2024) · Nutrients · doi:10.3390/nu16152511 · Cited by 26
The protease corin regulates electrolyte homeostasis in eccrine sweat glands
He, M., Zhou, T., Niu, Y., Feng, W., Gu, X., Xu, W., Zhang, S., Wang, Z., Zhang, Y., Wang, C., et al. (2021) · PLoS Biology · doi:10.1371/journal.pbio.3001090 · Cited by 20
Normative data on regional sweat-sodium concentrations of professional male team-sport athletes
Ranchordas, M. K., Tiller, N. B., Ramchandani, G., Jutley, R., Blow, A., Tye, J., & Drury, B. (2017) · Journal of the International Society of Sports Nutrition · doi:10.1186/s12970-017-0197-4 · Cited by 23
“[1, 2]).”
Garwolińska, D., Kot‐Wasik, A., & Hewelt-Belka, W. (2022) · Molecular Omics · doi:10.1039/d2mo00212d · Cited by 21
Anaerobic threshold using sweat lactate sensor under hypoxia
Okawara, H., Iwasawa, Y., Sawada, T., Sugai, K., Daigo, K., Seki, Y., Ichihara, G., Nakashima, D., Sano, M., Nakamura, M., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-49369-7 · Cited by 21
“Sampling human sweat, rich in physiological information, can enable noninvasive monitoring 14 .”
BackgroundDing, H., Yang, H., & Tsujimura, S. (2024) · Advanced Science · doi:10.1002/advs.202401947 · Cited by 19
Capillary-osmotic wearable patch based on lateral flow assay for sweat potassium analysis
Mukherjee, S., Salazar, S. P., Saha, T., Dickey, M. D., & Velev, O. D. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.136383 · Cited by 17
Heat acclimatization blunts copeptin responses to hypertonicity from dehydrating exercise in humans
Stacey, M. J., Woods, D. R., Brett, S. J., Britland, S. E., Fallowfield, J. L., Allsopp, A. J., & Delves, S. K. (2018) · Physiological Reports · doi:10.14814/phy2.13851 · Cited by 17
“Perhaps for this reason, the electrolyte values determined from pharmacologically induced sweating may vary from thermal or exercise-associated sweat (Baker 2017).”
Zhou, J., Zhang, Q., Zhang, M., Aikebaier, S., Zhu, X., & Zhou, X. (2025) · Journal of Advanced Research · doi:10.1016/j.jare.2025.08.036 · Cited by 31
Wearable Sensors for Precise Exercise Monitoring and Analysis
Su, B., Li, F., & Su, B. (2025) · Biosensors · doi:10.3390/bios15110734 · Cited by 24
“…spanning event detection, joint definitions, and reporting conventions, limits comparability and reproducibility; therefore, studies should adopt ISB guidance, publish mappings from raw data to derived metrics and sensor placement protocols, and report uncertainty estimates [24,25,28–31].”
Sweat, tears, and beyond: advanced wearable sensors for personalized health and athletic performance
Gülgösteren, E., Ermiş, S. A., Algin, A., Toros, T., Serin, E., Şekeroğlu, M. Ö., & KAYIŞOĞLU, N. B. (2025) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2025.1684674 · Cited by 25
“Sweat provides biomarkers such as sodium, lactate, and cortisol, offering crucial insights into hydration and metabolic states (Min et al., 2023; Childs et al., 2024; Baker, 2017).”
Peel, J., McNarry, M. A., Heffernan, S. M., Nevola, V. R., Kilduff, L. P., & Waldron, M. (2022) · PLoS ONE · doi:10.1371/journal.pone.0278652 · Cited by 17
“Local sweat rate is typically measured using the ventilated capsule method; additionally, absorbent patches affixed to the skin can be used by assessing pre- to post-exercise differences in patch mass, across a known time period [8,10,12].”
BackgroundMethodCastro‐Sepúlveda, M., Cancino, J., Fernández‐Verdejo, R., Pérez-Luco, C., Jannas-Vela, S., Ramírez‐Campillo, R., Coso, J. D., & Zbinden‐Foncea, H. (2019) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2019-0129 · Cited by 17
Evaluation of Sweat-Sampling Procedures for Human Stress-Biomarker Detection
Nunes, M. J., Moura, J. J. G., Noronha, J. P., Branco, L. C., Samhan-Arias, A. K., Sousa, J. P., Rouco, C., & Cordas, C. M. (2022) · Analytica—A Journal of Analytical Chemistry and Chemical Analysis · doi:10.3390/analytica3020013 · Cited by 17
“However, hidromeiosis may be minimised with the decrease in sampling time or the use of patches made from a material with a high absorbent capacity [50].”
BackgroundNoninvasive Monitoring to Detect Dehydration: Are We There Yet?
Gray, M. L., Birkenfeld, J., & Butterworth, I. (2023) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121028 · Cited by 19
Dual-Valved Skin-Interfaced Microfluidic Device for Programmed Time-Control Sweat Collection
Yang, J. H., David, U., Noh, Y. S., & Koh, A. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.134441 · Cited by 22
Dermal-fluid-enabled detection platforms for non-invasive ambulatory monitoring
Veronica, A., Li, Y., Li, Y., Hsing, I., & Nyein, H. Y. Y. (2023) · Sensors & Diagnostics · doi:10.1039/d3sd00165b · Cited by 19
Novel Sweat-Based Wearable Device for Advanced Monitoring of Athletic Physiological Biometrics
Aguilar-Torán, J., Rabost-Garcia, G., Toinga-Villafuerte, S., Álvarez-Carulla, A., Colmena-Rubil, V., Fajardo-Garcia, A., Cardona-Bonet, A., Casals‐Terré, J., Muñoz-Pascual, X., Miribel‐Català, P. L., et al. (2023) · Sensors · doi:10.3390/s23239473 · Cited by 23
Baker, L. B., King, M. A., Keyes, D. M., Brown, S. D., Engel, M. D., Seib, M. S., Aranyosi, A. J., & Ghaffari, R. (2022) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2022-0017 · Cited by 17
Self-citationSweatSkin: Rapidly Prototyping Sweat-Sensing On-Skin Interface Based on Microfluidics
Lee, C.-J., Yang, D., Ku, P.-S., & Kao, H.-L. (2023) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3631425 · Cited by 19
“Given the significant diversity in sweating, there is a need to develop personalized devices based on individual sweat profiles [3].”
BackgroundKatsumata, Y., Muramoto, Y., Ishida, N., Takemura, R., Nagashima, K., Ikoma, T., Kawamatsu, N., Araki, M., Goda, A., Okawara, H., et al. (2024) · Scientific Reports · doi:10.1038/s41598-024-70001-9 · Cited by 16
“Human sweat when utilized as a source of physiological information may allow for non-invasive assessments during exercise [5].”
BackgroundThe effect of sweat sample storage condition on sweat content
Klous, L., Folkerts, M. A., Daanen, H. A. M., & Gerrett, N. (2021) · Temperature · doi:10.1080/23328940.2020.1867294 · Cited by 16
“For sweat sampling, the absorbent material (Cutisoft, BSN Medical, Almere, The Netherlands) was covered with an impermeable layer (Parafilm-M, Bemis, Saint Louis, USA) and was attached to the skin by a porous adhesive (Fixomull stretch, BSN Medical, Almere, The Netherlands).”
BackgroundMethodInfluentialLy, N., Hamstra-Wright, K. L., & Horswill, C. A. (2023) · Nutrients · doi:10.3390/nu15224759 · Cited by 28
“Sweat collection occurred after the first exercise interval, so participants had likely achieved a steady-state sweat rate as required [19].”
BackgroundMethod3D Printed Ion-Responsive Personalized Transdermal Patch
Zhu, D., Peng, X., Li, L., Zhang, J., & Xiao, P. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c18036 · Cited by 15
Abdelnour, M., Berkachy, R., Nasreddine, L., & Fares, E.-J. (2024) · Sensors · doi:10.3390/s24186024 · Cited by 21
“Post-exercise body mass was taken after voiding and the following equation was used [23]: Whole body sweating rate (WBSR) = [Body massPre-Ex − (Body massPost-Ex − fluid intakeEX)]/exercise duration Body weight was measured individually before and after training using the BIA machine right after…”
MethodPark, S. H., & Pak, J. J. (2024) · Sensors · doi:10.3390/s24216945 · Cited by 14
Konopka, M. J., Zeegers, M. P., Solberg, P. A., Delhaije, L., MEEUSEN, R. R., Ruigrok, G., Rietjens, G. J., & Sperlich, B. (2022) · PLoS ONE · doi:10.1371/journal.pone.0279492 · Cited by 20
Brasier, N., Osthoff, M. F., Ieso, F. D., & Eckstein, J. (2021) · Journal of Medical Internet Research · doi:10.2196/25907 · Cited by 15
“Electrolyte concentrations in sweat are known to be dynamic over time when exercising, and sweat rate is known to change with alterations in body temperature [74].”
Tattoos do not affect exercise-induced localised sweat rate or sodium concentration
Rogers, E., Irwin, C., McCartney, D., Cox, G. R., & Desbrow, B. (2019) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2019.06.004 · Cited by 12
Impact of Sodium Ingestion During Exercise on Endurance Performance: A Systematic Review
McCubbin, A. J., & Costa, R. J. S. (2018) · Monash University Research Portal (Monash University) · doi:10.5923/j.sports.20180803.05 · Cited by 12
Post-Exercise Sweat Loss Estimation Accuracy of Athletes and Physically Active Adults: A Review
O'Neal, E. K., Boy, T. G., Davis, B. H., Pritchett, K. L., PRITCHETT, R. C., Nepocatych, S., & Black, K. E. (2020) · Sports · doi:10.3390/sports8080113 · Cited by 15
“The authors recognize that sweat loss is more complex than this simple model due to the presence and density of electrolytes and metabolites found in sweat [19] and respiratory water and gas exchanges related to metabolic processes [20].”
BackgroundSoft, Sweat‐Powered Health Status Sensing and Visualization System Enabled by Laser‐Fabrication
Zhao, G., Park, W., Huang, X., Hu, Y., Li, Z.-Y., Chen, Y., Zhang, Q., Xu, G., Gao, Y., Zhang, B., et al. (2023) · Advanced Sensor Research · doi:10.1002/adsr.202300070 · Cited by 13
García-Rey, S., Gil-Hernández, E., Gunatilake, U. B., Basabe‐Desmonts, L., & Benito‐Lopez, F. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.133514 · Cited by 12
Grossmann, F., Perret, C., Roelands, B., MEEUSEN, R. R., & Flueck, J. L. (2022) · Nutrients · doi:10.3390/nu14142930 · Cited by 11
“, hot temperatures, high relative humidity) [9,10] and varies from 0.”
BackgroundReal-time smart multisensing wearable platform for monitoring sweat biomarkers during exercise
Lafaye, C., Rovira, M., Demuru, S., Wang, S., Kim, J., Kunnel, B. P., Besson, C., Fernández‐Sánchez, C., Serra-Graells, F., Margarit, J. M., et al. (2022) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas54905.2022.9948565 · Cited by 14
“with exercise [2] and hot/humid conditions or pharmacologically using the pilocarpine iontophoresis technique [3].”
MethodBorra, V., Brier, N. D., Berry, D. C., Zideman, D. A., Singletary, E. M., Buck, E. D. J. D., & _, _. (2023) · Journal of Athletic Training · doi:10.4085/1062-6050-0682.22 · Cited by 13
Wearable Device for Continuous and Real-Time Monitoring of Human Sweat Sodium
Noor, A. M., Farisi, M. S. A., Mazalan, M., Ibrahim, N. F. A., Wahab, A. A., Zakaria, Z., Rusli, N. I., Sabani, N. B., & Manaf, A. A. (2025) · Sensors · doi:10.3390/s25113467 · Cited by 13
“These tests involved analyzing samples with known sodium ion concentrations as artificial sweat, ranging from 10 mM to 200 mM [35].”
Nelson, R. S., Grossman, M. G., Klug, Z. M., Calamari, M., Donayre, A., Cybulski, T. R., Schooley, J., Griffith, G. J., Corcos, D. M., Wright, D. E., et al. (2025) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2506137122 · Cited by 14
“A detailed description of the CF Patch and smartphone application has been published previously (12, 13, 22).”
Exercise and Heat Stress: Inflammation and the Iron Regulatory Response
McKay, A. K. A., McCormick, R., Tee, N., & Peeling, P. (2021) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2021-0080 · Cited by 13
How to integrate recovery during heat acclimation
Ihsan, M., Périard, J. D., & Racinais, S. (2020) · British Journal of Sports Medicine · doi:10.1136/bjsports-2020-102390 · Cited by 15
A fully wearable conductive yarn-based sweat sensor powered by shoe insole-based TENG
Johns, M., Puluckul, P. P., Singh, R. K., Parrilla, M., Wael, K. D., & Weyn, M. (2025) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2025.138166 · Cited by 11
Rivera‐Brown, A. M., & Quiñones-González, J. R. (2020) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2019-0299 · Cited by 11
PCL/PEO Polymer Membrane Prevents Biofouling in Wearable Detection Sensors
Delgado‐Rivera, R., García-Rodríguez, W., López, L., Cunci, L., Resto, P. J., & Domenech, M. (2023) · Membranes · doi:10.3390/membranes13080728 · Cited by 10
“The dyed DI water was pumped through the system at a rate of 3 mL/min, simulating the sweat rate under constant exercise [34,35].”
MethodMolecular biomarkers for assessing the heat-adapted phenotype: a narrative scoping review
Corbett, J., Young, J. S., Tipton, M., Costello, J. T., Williams, T. B., Walker, E. F., Lee, B., & Stevens, C. E. (2023) · The Journal of Physiological Sciences · doi:10.1186/s12576-023-00882-4 · Cited by 10
“However, caution is warranted due to reported substantial inter and intra-individual variability in sweat Na+ concentration [11].”
BackgroundCellular Chemical Field and Cellular Homeostasis
Cong, B., Lü, L., Wang, Q., He, T., Li, J., Xie, H., Zhang, A., & Fan, X. (2024) · Engineering · doi:10.1016/j.eng.2024.03.001 · Cited by 11
Keefe, M. S., Benjamin, C. L., Casa, D. J., & Sekiguchi, Y. (2024) · Applied Sciences · doi:10.3390/app142210103 · Cited by 18
Liquid transport strategies in wearable and implantable microfluidic systems
Wang, Q., Jia, Y., & Li, J. (2025) · Lab on a Chip · doi:10.1039/d5lc00593k · Cited by 11
Wei, L., Lv, Z., He, Y., Guo, D., Cheng, L., Wu, H., & Liu, A. (2022) · Biosensors · doi:10.3390/bios13010067 · Cited by 10
“This trend is similar to previous reports [17,20], which may be due to the secretion rate of chloride ion in secretory coil of sweat glands increasing proportionally with the sweat rate, but it is larger than the reabsorption rate in the proximal duct of sweat glands, so that a higher final concentration of chloride i…”
ResultYang, H., Ding, H., Wei, W., Li, X.-F., Duan, X., Zhuang, C., Liu, W., Chen, S., & Wang, X. (2024) · Lab on a Chip · doi:10.1039/d3lc00791j · Cited by 10
Metadata
- Authors
- Baker, L. B.
- Affiliations
- Gatorade Sports Science Institute (US)
- Corresponding author
- Baker, Lindsay B.
- ORCID
- Baker, Lindsay B.
- Venue
- Sports Medicine
- Published
- 2017-03
- Volume
- 47
- Issue
- S1
- Pages
- 111-128
- ISSN
- 0112-1642 (ISSN-L)
- 1179-2035
- PMC
- PMC5371639
- OpenAlex
- W2597545654
- Cited by
- 403
- References
- 233
- Citations by year
- 2026: 66 · 2025: 53 · 2024: 46 · 2023: 48 · 2022: 45 · 2021: 47 · 2020: 47 · 2019: 27 · 2018: 18 · 2017: 5
- FWCI
- 3.25
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Sports Medicine (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- PepsiCo
- Gran Sasso Science Institute
- Topics
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- sweat rate, sweat sodium concentration, sweat test, within-person variability, interindividual variability, fluid and electrolyte replacement, thermoregulatory sweating, weight change, heat acclimation, exercise intensity, hydration status, athletes
- MeSH terms
- Humans, Sodium, Sports, Sweat, Sweating, Water-Electrolyte Balance, Exercise, Athletes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.