Sweating Rate and Sweat Sodium Concentration in Athletes: A Review of Methodology and Intra/Interindividual Variability
Open accessThe DOI matches its Crossref record; 233 of the 233 references it cites were found in a registry or an index.
Abstract
Athletes lose water and electrolytes as a consequence of thermoregulatory sweating during exercise and it is well known that the rate and composition of sweat loss can vary considerably within and among individuals. Many scientists and practitioners conduct sweat tests to determine sweat water and electrolyte losses of athletes during practice and competition. The information gleaned from sweat testing is often used to guide personalized fluid and electrolyte replacement recommendations for athletes; however, unstandardized methodological practices and challenging field conditions can produce inconsistent/inaccurate results. The primary objective of this paper is to provide a review of the literature regarding the effect of laboratory and field sweat-testing methodological variations on sweating rate (SR) and sweat composition (primarily sodium concentration [Na + ]). The simplest and most accurate method to assess whole-body SR is via changes in body mass during exercise; however, potential confounding factors to consider are non-sweat sources of mass change and trapped sweat in clothing. In addition, variability in sweat [Na + ] can result from differences in the type of collection system used (whole body or localized), the timing/duration of sweat collection, skin cleaning procedure, sample storage/handling, and analytical technique. Another aim of this paper is to briefly review factors that may impact intra/interindividual variability in SR and sweat [Na + ] during exercise, including exercise intensity, environmental conditions, heat acclimation, aerobic capacity, body size/composition, wearing of protective equipment, sex, maturation, aging, diet, and/or hydration status. In summary, sweat testing can be a useful tool to estimate athletes’ SR and sweat Na + loss to help guide fluid/electrolyte replacement strategies, provided that data are collected, analyzed, and interpreted appropriately.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Fig. 1 Frequency histograms of (a) absolute whole-body sweating rate and (b) relative whole-body sweating rate from 461 athletes (327 adults, 134 youth; 369 male, 92 female) of various sports (e.g. American Football, basketball, baseball, soccer, tennis, and endurance) tested during training or competition in various environmental conditions (15–50 °C, 20–79% relative humidity). The vertical line represents the mean value. Reproduced from Baker et al. [96], with permission](https://figures.cochat.ai/paper-figures/0c406296f9324ce4a1009eef5abc81cb/sweating-rate-and-sweat-sodium-concentration-in-athletes-a-review-of-methodology-figure-1.jpg)
![Fig. 2 Frequency histograms of (a) forearm sweat sodium concentration ([Na+]) using the absorbent patch technique and (b) predicted whole-body sweat [Na+] from 506 athletes (367 adults, 139 youth; 404 male, 102 female) of various sports (e.g. American Football, basketball, baseball, soccer, tennis, and endurance) tested during training or competition in various environmental conditions (15–50 °C, 20–79% relative humidity). The vertical line represents the mean value. Reproduced from Baker et al. [96], with permission](https://figures.cochat.ai/paper-figures/c9cba02b8bb04a6a9f0c3d59a3cc51d2/sweating-rate-and-sweat-sodium-concentration-in-athletes-a-review-of-methodology-figure-2.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Since sweat composition is modulated by a variety of factors including age, body mass, diet, and hydration status (46)”
From Regional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat (2019) · cites this paper as [46]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“a wide range of analytical techniques have been used by scientists and practitioners to measure sweat composition”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Baker 2017
The cited source says what the claim attributes to it.
In the citing paper
“Nonetheless, final sweat typically has a [K+] similar, albeit with a slightly broader range (~2–8 mmol/L), to that reported for blood plasma.29,41,42”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [29]
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“These findings agree with previous investigations of exercise sweat (21, 46, 47).”
From Regional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat (2019) · cites this paper as [46]
Experimental — accuracy not yet measuredIn the citing paper
“However, the current mechanism of potassium ion secretion in sweat is still uncertain, so the final potassium concentration in sweat may be maintained within the plasma potassium concentration range 76 .”
From A review of sampling, energy supply and intelligent monitoring for long-term sweat sensors (2022) · cites this paper as [76]
3 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · Applied Ergonomics · doi:10.1016/0003-6870(92)90318-p · Cited by 5,737
Webb, A. K. (2006) · Cited by 4,369
ACSM Position Stand: Exercise and Fluid Replacement
Convertino, V. A., Armstrong, L. E., Coyle, E. F., Mack, G. W., Sawka, M. N., Senay, L. C., & Sherman, W. M. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199610000-00045 · Cited by 1,965
Gibson, L. E., & Cooke, R. E. (1959) · Pediatrics · doi:10.1542/peds.23.3.545 · Cited by 1,434 · cited 2×
“Pilocarpine iontophoresis was standardized by Gibson and Cooke in 1959 (Quantitative Pilocarpine Iontophoretic Test [or QPIT] method [89]).”
MethodRowe, S. M., Miller, S., & Sorscher, E. J. (2005) · New England Journal of Medicine · doi:10.1056/nejmra043184 · Cited by 1,398
Balance of carbohydrate and lipid utilization during exercise: the "crossover" concept
Brooks, G. A., & Mercier, J. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.76.6.2253 · Cited by 862 · cited 1×
“In addition, the following papers provide equations to calculate mass loss from substrate oxidation [79, 85, 86] and respiratory water [79, 85].”
BackgroundBiology of sweat glands and their disorders. I. Normal sweat gland function
Sato, K., Kang, W. H., Saga, K., & Sato, K. T. (1989) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(89)70063-3 · Cited by 717 · cited 2×
“More details on the structure, function, and control of eccrine sweat glands can be found in several comprehensive reviews [19, 26, 29, 32, 44, 57].”
BackgroundAssessing Hydration Status: The Elusive Gold Standard
Armstrong, L. E. (2007) · Journal of the American College of Nutrition · doi:10.1080/07315724.2007.10719661 · Cited by 643 · cited 1×
“The simplest and most accurate method to assess WBSR is via changes in nude body mass from before to after exercise [2, 4, 78]; however, corrections for non-sweat sources of body mass change should be considered.”
MethodInvited Review: Aging and human temperature regulation
Kenney, W. L., & Munce, T. A. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00202.2003 · Cited by 577
Robinson, S., & Robinson, A. H. (1954) · Physiological Reviews · doi:10.1152/physrev.1954.34.2.202 · Cited by 514 · cited 4×
“Regarding the impact of sweat stimulation methodology on sweat composition, two studies have shown higher [Na] and [Cl] with exercise versus passive heating [98, 104].”
BackgroundInfluential
Research works printed but not linked: 5
- Kuno Y Human perspiration 1956 Springfield Charles C. Thomas Publisher
- Berne RM Levy MN Physiology 1998 St. Louis Mosby
- Ogata K Functional variations in human sweat glands, with remarks upon the regional difference of the amount of sweat J Orient Med 1935 23 98 101
- Yoshimura H Acclimatization to heat and cold. Essential problems in climatic physiology 1960 Kyoto Nankodo
- Candas V Dejours P Adaptation to extreme environments. Thermophysiological changes in man during humid heat acclimation Comparative physiology of environmental adaptations 1987 Basel Karger 76 93
Cited by
Accessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758
Physiology of sweat gland function: The roles of sweating and sweat composition in human health
Baker, L. B. (2019) · Temperature · doi:10.1080/23328940.2019.1632145 · Cited by 732
“However, a fundamental issue with this assertion is that sweat [Na] and [Cl] are known to vary considerably within and among individuals; and a change in hydration status is only one of many factors that could play a role in this variability [132].”
BackgroundSelf-citationSkin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Périard, J. D., Eijsvogels, T. M. H., & Daanen, H. A. M. (2021) · Physiological Reviews · doi:10.1152/physrev.00038.2020 · Cited by 647
Wearable sensors for monitoring the physiological and biochemical profile of the athlete
Seshadri, D. R., Li, R. T., Voos, J. E., Rowbottom, J. R., Alfes, C. M., Zorman, C. A., & Drummond, C. K. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0150-9 · Cited by 537
Skin-interfaced systems for sweat collection and analytics
Choi, J., Ghaffari, R., Baker, L. B., & Rogers, J. A. (2018) · Science Advances · doi:10.1126/sciadv.aar3921 · Cited by 433
Self-citationNyein, H. Y. Y., Bariya, M., Kivimäki, L., Uusitalo, S., Liaw, T. S., Jansson, E., Ahn, C. H., Hangasky, J. A., Zhao, J., Lin, Y., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw9906 · Cited by 388
“Since sweat composition is modulated by a variety of factors including age, body mass, diet, and hydration status (46), more comprehensive longitudinal studies will be conducted to extract personalized relations between sweat parameters and medical or physiological status.”
Physiological mechanisms determining eccrine sweat composition
Baker, L. B., & Wolfe, A. S. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04323-7 · Cited by 367
“For example, if the intent is to use the results to inform athletes on their individual sweat electrolyte losses, then the sweat testing should be conducted during exercise and in conditions (i.e., thermal environment) specific/relevant to their sport (Baker 2017).”
BackgroundMethodSelf-citationWearable potentiometric ion sensors
Parrilla, M., Cuartero, M., & Crespo, G. A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.11.024 · Cited by 334
Lactate Biosensing for Reliable On-Body Sweat Analysis
Xuan, X., Pérez-Ràfols, C., Chen, C., Cuartero, M., & Crespo, G. A. (2021) · ACS Sensors · doi:10.1021/acssensors.1c01009 · Cited by 250
Baker, L. B., Model, J. B., Barnes, K. A., Anderson, M. L., Lee, S. P., Lee, K. A., Brown, S. D., Reimel, A. J., Roberts, T. J., Nuccio, R. P., et al. (2020) · Science Advances · doi:10.1126/sciadv.abe3929 · Cited by 243
Self-citationKwon, K., Kim, J. U., Deng, Y., Krishnan, S. R., Choi, J., Jang, H., Lee, K., Su, C.-J., Yoo, I., Wu, Y., et al. (2021) · Nature Electronics · doi:10.1038/s41928-021-00556-2 · Cited by 230
The challenges and promise of sweat sensing
Davis, N., Heikenfeld, J., Milla, C., & Javey, A. (2024) · Nature Biotechnology · doi:10.1038/s41587-023-02059-1 · Cited by 211
“The gold standards in the field for measuring local sweat rate are hygrometry and gravimetry, although these both require trained technicians for device use 73 .”
Advanced Wearable Microfluidic Sensors for Healthcare Monitoring
Li, S., Ma, Z., Cao, Z., Pan, L., & Shi, Y. (2020) · Small · doi:10.1002/smll.201903822 · Cited by 212
Skin in the diagnostics game: Wearable biosensor nano- and microsystems for medical diagnostics
Dervisevic, M., Alba, M., Prieto-Simon, B., & Voelcker, N. H. (2020) · Nano Today · doi:10.1016/j.nantod.2019.100828 · Cited by 203
Ardalan, S., Hosseinifard, M., Vosough, M., & Golmohammadi, H. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112450 · Cited by 195
State of Sweat: Emerging Wearable Systems for Real-Time, Noninvasive Sweat Sensing and Analytics
Ghaffari, R., Yang, D. S., Kim, J., Mansour, A., Wright, J. A., Model, J. B., Wright, D. E., Rogers, J. A., & Ray, T. R. (2021) · ACS Sensors · doi:10.1021/acssensors.1c01133 · Cited by 178
Bioaccessibility and Bioavailability of Minerals in Relation to a Healthy Gut Microbiome
Bielik, V., & Kolisek, M. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22136803 · Cited by 172
“gender [15], and intra/interindividual variability [16].”
Zhong, B., Jiang, K., Wang, L., & Shen, G. (2022) · Advanced Science · doi:10.1002/advs.202103257 · Cited by 164
Zhai, Q., Yap, L. W., Wang, R., Gong, S., Guo, Z., Liu, Y., Lyu, Q., Wang, J., Simon, G. P., & Cheng, W. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00274 · Cited by 162
A wearable sensor for the detection of sodium and potassium in human sweat during exercise
Pirovano, P., Dorrian, M., Shinde, A., Donohoe, A., Brady, A. J., Moyna, N. M., Wallace, G., Diamond, D., & McCaul, M. (2020) · Talanta · doi:10.1016/j.talanta.2020.121145 · Cited by 158
“This concentration range falls within the typical physiological range reported for K+ (between 2 and 10 mM) [29].”
BackgroundParrilla, M., Ortiz‐Gómez, I., Cánovas, R., Salinas‐Castillo, A., Cuartero, M., & Crespo, G. A. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b02126 · Cited by 167
Sasikala, A., Nguyen, N., & Sreejith, K. R. (2024) · Lab on a Chip · doi:10.1039/d4lc00089g · Cited by 153
Madruga, L. Y. C., Sabino, R. M., dos Santos, E. C. G., Popat, K. C., Balaban, R. D. C., & Kipper, M. J. (2020) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2020.02.274 · Cited by 140
Can Wearable Sweat Lactate Sensors Contribute to Sports Physiology?
Hoovels, K. V., Xuan, X., Cuartero, M., Gijssel, M., Swarén, M., & Crespo, G. A. (2021) · ACS Sensors · doi:10.1021/acssensors.1c01403 · Cited by 143
Condo, D., Lohman, R., Kelly, M., & Carr, A. (2019) · Nutrients · doi:10.3390/nu11050971 · Cited by 122
“There is limited available evidence on the required sodium intake in an athletic population, as there is a high degree of inter-variability between athletes, often dependent on individual sweat sodium concentrations and sweat rates [43].”
BackgroundKim, S. B., Lee, K., Raj, M. S., Lee, B., Reeder, J. T., Koo, J., Hourlier‐Fargette, A., Bandodkar, A. J., Won, S. M., Sekine, Y., et al. (2018) · Small · doi:10.1002/smll.201802876 · Cited by 115
Data-driven personal thermal comfort prediction: A literature review
Feng, Y., Liu, S., Wang, J., Yang, J., Jao, Y., & Wang, N. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2022.112357 · Cited by 130
Baker, L. B., De Chavez, P. J. D., Ungaro, C. T., Sopeña, B. C., Nuccio, R. P., Reimel, A. J., & Barnes, K. A. (2019) · European Journal of Applied Physiology · doi:10.1007/s00421-018-4048-z · Cited by 110
“Sweat [K+] was included in this study, because it has been suggested to be a good measure of quality control (Baker 2017; Dziedzic et al.”
BackgroundMethodInfluentialSelf-citationSeshadri, D. R., Thom, M. L., Harlow, E. R., Gabbett, T. J., Geletka, B. J., Hsu, J. J., Drummond, C. K., Phelan, D. M. J., & Voos, J. E. (2021) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2020.630576 · Cited by 147
“It is well-established that sweat rate is proportional to exercise intensity (Baker, 2017).”
BackgroundMondal, S., Kim, S., & Choi, C. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b22915 · Cited by 101
Printed microfluidic sweat sensing platform for cortisol and glucose detection
Naik, A. R., Zhou, Y., Dey, A. A., Arellano, D. L. G., Okoroanyanwu, U., Secor, E. B., Hersam, M. C., Morse, J. D., Rothstein, J. P., Carter, K. R., et al. (2022) · Lab on a Chip · doi:10.1039/d1lc00633a · Cited by 108
Sweat and Sebum Preferences of the Human Skin Microbiota
Swaney, M. H., Nelsen, A., Sandstrom, S., & Kalan, L. R. (2023) · Microbiology Spectrum · doi:10.1128/spectrum.04180-22 · Cited by 96
Wearable and Biodegradable Sensors for Clinical and Environmental Applications
Baldo, T. A., de Lima, L. F., Mendes, L. F., de Araujo, W. R., Paixão, T. R. L. C., & Coltro, W. K. T. (2020) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.0c00735 · Cited by 98
Lam, C. K. C., Hang, J., Zhang, D., Wang, Q., Ren, M., & Huang, C. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107877 · Cited by 94
Schwartz, D., Magen, Y. K., Levy, A., & Gefen, A. (2018) · International Wound Journal · doi:10.1111/iwj.12937 · Cited by 88
“Specifically, the sweat that we used was collected from athletes during the first 30 minutes of practice and was hence characterised by a higher mineral content compared with subsequent sweat samples.(49) When water evaporates from the skin surface, the remaining salts generate a thin textured layer, which contributes…”
BackgroundWu, C.-H., Hing, H. J., Baessler, P., Balanay, R. K., & Ray, T. R. (2023) · Science Advances · doi:10.1126/sciadv.adg4272 · Cited by 95
Klous, L., de Ruiter, C. J., Scherrer, S., Gerrett, N., & Daanen, H. A. M. (2021) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04562-8 · Cited by 86
“Sweat sodium and chloride are suggested to be potential biomarkers for an electrolyte imbalance, as in hyponatremia, muscle cramps and dehydration (Baker 2017; Morgan et al.”
BackgroundGarg, M., Guo, H., Maclam, E., Zhanov, E., Samudrala, S., Pavlov, A. F., Rahman, M. S., Namkoong, M., Moreno, J. P., & Tian, L. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c10033 · Cited by 95
A non-contact wearable device for monitoring epidermal molecular flux
Shin, J., Song, J. W., Flavin, M. T., Cho, S., Li, S., Tan, A., Pyun, K. R., Huang, A. G., Wang, H., Jeong, S., et al. (2025) · Nature · doi:10.1038/s41586-025-08825-2 · Cited by 104
Zhao, Z., Li, Q., Dong, Y., Gong, J., Li, Z., & Zhang, J. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.131154 · Cited by 81
Yang, Q., Rosati, G., Abarintos, V., Aroca, M. A., Osma, J. F., & Merkoçi, A. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114005 · Cited by 92
Niu, J., Lin, S., Chen, D., Wang, Z., Cao, C., Gao, A., Cui, S., Liu, Y., Hong, Y., Zhi, X., et al. (2023) · Small · doi:10.1002/smll.202306769 · Cited by 84
A review of sampling, energy supply and intelligent monitoring for long-term sweat sensors
Yang, P., Wei, G., Liu, A., Huo, F., & Zhang, Z. (2022) · npj Flexible Electronics · doi:10.1038/s41528-022-00165-9 · Cited by 77
A novel device for detecting anaerobic threshold using sweat lactate during exercise
Seki, Y., Nakashima, D., Shiraishi, Y., Ryuzaki, T., Ikura, H., Miura, K., Suzuki, M., Watanabe, T., Nagura, T., Matsumato, M., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-84381-9 · Cited by 86
Sports Dietitians Australia Position Statement: Nutrition for Exercise in Hot Environments
McCubbin, A. J., Allanson, B. A., Caldwell Odgers, J. N., Cort, M. M., Costa, R. J. S., Cox, G. R., Crawshay, S. T., Desbrow, B., Freney, E. G., Gaskell, S. K., et al. (2020) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2019-0300 · Cited by 74
“Methodological considerations for assessing sweat composition are beyond the scope of this statement; readers are directed to a recent comprehensive review on the subject (Baker, 2017).”
BackgroundSilicon Micropillar Array-Based Wearable Sweat Glucose Sensor
Dervisevic, M., Alba, M., Esser, L., Tabassum, N. H., Prieto‐Simón, B., & Voelcker, N. H. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c22383 · Cited by 78
An Integrated Paper-Based Microfluidic Device for Real-Time Sweat Potassium Monitoring
Liang, B., Cao, Q., Mao, X., Pan, W., Tu, T., Lü, F., & Ye, X. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3009327 · Cited by 76
“By report, the mechanism of sweat potassium loss is unclear, irrespective of the sweat rate [30].”
BackgroundPaul, B., Demuru, S., Lafaye, C., Saubade, M., & Briand, D. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202000910 · Cited by 74
Finewax, Z., Pagonis, D., Claflin, M. S., Handschy, A. V., Brown, W. L., Jenks, O. J., Nault, B. A., Day, D. A., Lerner, B. M., Jimenez, J. L., et al. (2020) · Indoor Air · doi:10.1111/ina.12781 · Cited by 79
Skin-Mountable Biosensors and Therapeutics: A Review
Lee, E. K., Kim, M. K., & Lee, C. H. (2019) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-060418-052315 · Cited by 75
A Capacitive Sweat Rate Sensor for Continuous and Real-Time Monitoring of Sweat Loss
Choi, D., Gonzales, M., Kitchen, G. B., Phan, D., & Searson, P. C. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01219 · Cited by 72
Exploitation of Antimicrobial Nanoparticles and Their Applications in Biomedical Engineering
Yang, X. A., Chung, E., Johnston, I., Ren, G., & Cheong, Y. (2021) · Applied Sciences · doi:10.3390/app11104520 · Cited by 72
Chen, Y., Kuan, W., & Liu, C. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17103377 · Cited by 72
“Previous studies employed a diverse range of methods to collect sweat for composition analyses [19,22,23].”
BackgroundA sweat-activated, wearable microbial fuel cell for long-term, on-demand power generation
Ryu, J., Landers, M., & Choi, S. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114128 · Cited by 69
Pérez, D., & Orozco, J. (2022) · Microchimica Acta · doi:10.1007/s00604-022-05228-2 · Cited by 72
“It is also possible to conclude that sweat composition changes according to the situation [61] and that the best sweat sample comes from the body at rest conditions.”
BackgroundMini review about metal organic framework (MOF)-based wearable sensors: Challenges and prospects
Meskher, H., Belhouari, S. B., & Sharifianjazi, F. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e21621 · Cited by 66
“Due to the quick sampling times and the ability to take measurements while sitting, which is more convenient than exercising [75].”
BackgroundAll-solid state ion-selective carbon black-modified printed electrode for sodium detection in sweat
Mazzaracchio, V., Serani, A., Fiore, L. D., Moscone, D., & Arduini, F. (2021) · Electrochimica Acta · doi:10.1016/j.electacta.2021.139050 · Cited by 69
A Focused Review on the Flexible Wearable Sensors for Sports: From Kinematics to Physiologies
Liu, L., & Zhang, X. (2022) · Micromachines · doi:10.3390/mi13081356 · Cited by 77
“SR can be simply measured by the body mass changes over time, but this imprecise, belated method may not detect the appearance of fluid imbalances in time, which greatly affects the performance and even the health of players [77,78].”
BackgroundBarwood, M. J., Gibson, O. R., Gillis, D. J., Jeffries, O., Morris, N. B., Pearce, J., Ross, M. L., Stevens, C. J., Rinaldi, K., Kounalakis, S. N., et al. (2020) · Sports Medicine · doi:10.1007/s40279-020-01313-9 · Cited by 73
Epidermal Wearable Biosensors for Monitoring Biomarkers of Chronic Disease in Sweat
Yuan, X., Li, C., Yin, X., Yang, Y., Ji, B., Niu, Y., & Ren, L. M. (2023) · Biosensors · doi:10.3390/bios13030313 · Cited by 64
“While some studies have shown that K+ in sweat has nothing to do with the rate of sweat production, and its correlation with blood K+ concentration has yet to be confirmed, other studies have found that K+ may vary within the blood concentration range [45].”
BackgroundJain, V., Ochoa, M., Jiang, H., Rahimi, R., & Ziaie, B. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0067-0 · Cited by 57
Liquid Metal‐Based Biosensors: Fundamentals and Applications
Jamalzadegan, S., Kim, S., Mohammad, N., Koduri, H., Hetzler, Z., Lee, G., Dickey, M. D., & Wei, Q. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202308173 · Cited by 63
Wei, L., Lv, Z., He, Y., Cheng, L., Qiu, Y., Huang, X., Ding, C., Wu, H., & Liu, A. (2022) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2022.133213 · Cited by 59
Vairo, D., Bruzzese, L., Marlinge, M., Fuster, L., Adjriou, N., Kipson, N., Brunet, P., Cautela, J., Jammes, Y., Mottola, G., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-12211-y · Cited by 54
Study of the Dielectric Properties of Artificial Sweat Mixtures at Microwave Frequencies
Eldamak, A. R., Thorson, S., & Fear, E. C. (2020) · Biosensors · doi:10.3390/bios10060062 · Cited by 61
Wang, S., Liu, M., Yang, X., Lu, Q., Xiong, Z., Li, L., Zheng, H., Feng, S., & Zhang, T. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114351 · Cited by 52
Recent Advances in Wearable Healthcare Devices: From Material to Application
Luo, X., Tan, H., & Wen, W. (2024) · Bioengineering · doi:10.3390/bioengineering11040358 · Cited by 81
“The concentration of Na + and K + , can be used for monitoring the whole body’s sweat rate [214,238,239], which would be helpful for athletes and workers who work outdoors during summer.”
BackgroundUncovering the Sweat Biofouling Components and Distributions in Electrochemical Sensors
Wang, X., He, A., Yu, B., Zhang, L., Pang, W., Zhang, H., & Niu, P. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c03158 · Cited by 53
The Gx Sweat Patch for personalized hydration management
Ghaffari, R., Aranyosi, A. J., Lee, S. P., Model, J. B., & Baker, L. B. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-022-00005-5 · Cited by 49
Self-citationConformal and Disposable Antenna-Based Sensor for Non-Invasive Sweat Monitoring
Eldamak, A. R., & Fear, E. C. (2018) · Sensors · doi:10.3390/s18124088 · Cited by 51
“r t real [46] a artificial s eat [19,47–50], a l re rese ts al st 65 f s eat electr l tes er a ra e f iffere t rati states [15,19].”
BackgroundGoulet, E. D. B., & Hoffman, M. D. (2019) · Sports Medicine · doi:10.1007/s40279-018-01051-z · Cited by 46
Wickham, K. A., McCarthy, D. G., Spriet, L. L., & Cheung, S. S. (2021) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00266.2021 · Cited by 53
Spinelli, J. C., Suleski, B. J., Wright, D. E., Grow, J. L., Fagans, G. R., Buckley, M. J., Yang, D. S., Yang, K., Beil, S. M., Wallace, J. C., et al. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01466-9 · Cited by 44
Tiwari, N., Chatterjee, S., Kaswan, K., Chung, J.-H., Fan, K., & Lin, Z. (2022) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2022.116064 · Cited by 48
Naderi, A., Rothschild, J. A., Santos, H. O., Hamidvand, A., Koozehchian, M. S., Ghazzagh, A., Berjisian, E., & Podlogar, T. (2025) · Sports Medicine · doi:10.1007/s40279-025-02213-6 · Cited by 77
“…exercise in a hot or humid environment, athletes may lose more than 2 L of sweat per hour, accompanied by substantial electrolyte, extracellular, and intracellular water loss that may negatively affect processes such as the rate of post-exercise glycogen and muscle protein resynthesis [44, 99].”
Quesnel, D. A., Cooper, M., Fernández-del-Valle, M., Reilly, A., & Calogero, R. M. (2023) · Journal of Eating Disorders · doi:10.1186/s40337-022-00685-9 · Cited by 64
“This pressure is required to supply vital organs with adequate oxygen and energy to function; thus, low blood pressure contributes to inadequate oxygen and nutrient availability, compromising vital organ functioning [77].”
BackgroundYang, M., Sun, N., Lai, X., Li, Y., Zhao, X., Wu, J., & Zhou, W. (2023) · Micromachines · doi:10.3390/mi14081497 · Cited by 43
“The sensitivity and linearity of the sensor were evaluated considering the concentration ranges of potassium and sodium ions in human sweat, which are approximately 1–24 mM [40–42] and 8–128 mM [22,43,44], respectively.”
BackgroundLohman, R., Carr, A., & Condo, D. (2019) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2018-0031 · Cited by 43
Wearable biosensors for human fatigue diagnosis: A review
Zhang, J., Chen, M., Peng, Y., Li, S., Han, D., Ren, S., Qin, K., Li, S., Han, T., Wang, Y., et al. (2022) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10318 · Cited by 51
An epifluidic electronic patch with spiking sweat clearance for event-driven perspiration monitoring
Kim, S., Park, S., Choi, J., Hwang, W., Kim, S.-H., Choi, I., Yi, H., & Kwak, R. (2022) · Nature Communications · doi:10.1038/s41467-022-34442-y · Cited by 43
Hashimoto, Y., Ishihara, T., Kuwabara, K., Amano, T., & Togo, H. (2022) · Micromachines · doi:10.3390/mi13040575 · Cited by 43
Dong, Y., Liu, T., Chen, S., Nithianandam, P., Matar, K., & Li, J. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202210136 · Cited by 41
Fabric as a Sensor: Towards Unobtrusive Sensing of Human Behavior with Triboelectric Textiles
Kiaghadi, A., Baima, M., Gummeson, J., Andrew, T., & Ganesan, D. (2018) · Proceedings of the 16th ACM Conference on Embedded Networked Sensor Systems · doi:10.1145/3274783.3274845 · Cited by 35
“Clinical gold-standard measures for perspiration sensing include weighing collected sweat generated or weighing an athlete before and after exercise [9].”
BackgroundSweat rate and sweat composition during heat acclimation
Klous, L., de Ruiter, C. J., Alkemade, P., Daanen, H. A. M., & Gerrett, N. (2020) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2020.102697 · Cited by 45
Autonomous wearable sensing enabled by capillary microfluidics: a review
Kuruvinashetti, K., Komeili, A., & Sanati‐Nezhad, A. (2025) · Lab on a Chip · doi:10.1039/d5lc00536a · Cited by 48
Rollo, I., Randell, R. K., Baker, L. B., Yanguas, J., Leal, D. M., Lizarraga, A., Mesalles, J., Jeukendrup, A. E., James, L. J., & Carter, J. M. (2021) · Nutrients · doi:10.3390/nu13020401 · Cited by 46
“Second, the analysis of sweat did not include potassium concentration, which would have been preferential as a quality control for sweat samples [43].”
BackgroundSelf-citationSpehar‐Délèze, A., Anastasova, S., & Vadgama, P. M. (2021) · Chemosensors · doi:10.3390/chemosensors9080195 · Cited by 39
Cinca-Morros, S., García-Rey, S., Álvarez‐Herms, J., Basabe‐Desmonts, L., & Benito‐Lopez, F. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.342988 · Cited by 39
Na, C. H., Sharma, N., Madugundu, A. K., Chen, R., Aksit, M. A., Rosson, G. D., Cutting, G. R., & Pandey, A. (2019) · Molecular & Cellular Proteomics · doi:10.1074/mcp.ra118.001101 · Cited by 35
“isotonic to plasma with the concentration of Na 145 mmol/l and Cl 115 mmol/l (36, 37).”
BackgroundBarnes, T. L., Cadaret, C. N., Beede, K. A., Schmidt, T. B., Petersen, J. L., & Yates, D. T. (2019) · Journal of Animal Science · doi:10.1093/jas/skz271 · Cited by 36
Choi, D.-H., Kitchen, G. B., Stewart, K. J., & Searson, P. C. (2020) · Scientific Reports · doi:10.1038/s41598-020-64406-5 · Cited by 35
Carr, A. R., Patel, Y., Neff, C. R., Charkhabi, S., Kallmyer, N. E., Angus, H. F., & Reuel, N. F. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0270-2 · Cited by 40
Bio-inspired fractal textile device for rapid sweat collection and monitoring
Chen, Y.-C., Shan, S.-S., Liao, Y., & Liao, Y. (2021) · Lab on a Chip · doi:10.1039/d1lc00328c · Cited by 36
Baker, L. B., Chavez, P. J. D. D., Nuccio, R. P., Brown, S. D., King, M. A., Sopeña, B. C., & Barnes, K. A. (2022) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00391.2022 · Cited by 42
Self-citationStepless IR Chromism in Ti3C2Tx MXene Tuned by Interlayer Water Molecules
Li, K., Lin, C., Liu, G., Guang, W., Ma, W., Li, M., Li, Y., & Huang, B. (2023) · Advanced Materials · doi:10.1002/adma.202308189 · Cited by 33
Microneedle-based sampling of dermal interstitial fluid using a vacuum-assisted skin patch
Jiang, X., Wilkirson, E. C., Bailey, A. O., Russell, W. K., & Lillehoj, P. B. (2024) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2024.101975 · Cited by 54
“15 Furthermore, prior studies have shown variability in the collection of other bodily fluids, including blood, 34 sweat, 35 and saliva, 36 among different individuals.”
A microfluidic patch for wireless wearable electrochemical detection of sweat metabolites
Hu, M., Wang, Z., Zhang, L., Lin, S., & Liao, J. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.136604 · Cited by 38
Screening of Potential Stress Biomarkers in Sweat Associated with Sports Training
Nunes, M. J., Cordas, C. M., Moura, J. J. G., Noronha, J. P., & Branco, L. C. (2021) · Sports Medicine - Open · doi:10.1186/s40798-020-00294-3 · Cited by 40
“Athletes lose water and electrolytes because of thermoregulatory sweating during physical training, and it is well known that the rate and composition of sweat loss can vary considerably within and among individuals [19].”
BackgroundMultifunctional Wearable System for Mapping Body Temperature and Analyzing Sweat
Alam, M. S., Kim, J. K., & Choi, J. (2023) · ACS Sensors · doi:10.1021/acssensors.3c00098 · Cited by 36
Metadata
- Authors
- Baker, L. B.
- Affiliations
- Gatorade Sports Science Institute (US)
- Corresponding author
- Baker, Lindsay B.
- ORCID
- Baker, Lindsay B.
- Venue
- Sports Medicine
- Published
- 2017-03
- Volume
- 47
- Issue
- S1
- Pages
- 111-128
- ISSN
- 0112-1642 (ISSN-L)
- 1179-2035
- PMC
- PMC5371639
- OpenAlex
- W2597545654
- Cited by
- 403
- References
- 233
- Citations by year
- 2026: 66 · 2025: 53 · 2024: 46 · 2023: 48 · 2022: 45 · 2021: 47 · 2020: 47 · 2019: 27 · 2018: 18 · 2017: 5
- FWCI
- 3.25
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Sports Medicine (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- PepsiCo
- Gran Sasso Science Institute
- Topics
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- sweat rate, sweat sodium concentration, sweat test, within-person variability, interindividual variability, fluid and electrolyte replacement, thermoregulatory sweating, weight change, heat acclimation, exercise intensity, hydration status, athletes
- MeSH terms
- Humans, Sodium, Sports, Sweat, Sweating, Water-Electrolyte Balance, Exercise, Athletes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.