Studies of diffusion in random fields produced by variations in susceptibility
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
The effects of diffusion of nuclear spins on the echo amplitudes in a multiple echo sequence are analyzed in a medium containing random distributions of susceptibility variations. It is predicted from theory that the apparent transverse relaxation rate is directly proportional to the variance of the distribution of the magnetic field gradients in a heterogeneous region. This dependence has been confirmed by computer simulation of diffusion in a randomly varying array of gradient fields. A physical model has been developed by considering the magnetostatic superposition of the field perturbations arising from many microspherical deposits, and a relationship derived between the number density, composition and size of the particles, and the variance of the resultant gradient field distribution. The Bloch equations are solved numerically for spins diffusing in random arrangements of such particles for multiple echo sequences of RF pulses, and the rate of loss of coherent transverse magnetization due to diffusion effects is calculated. The precise dependence of the apparent T2 on the statistics of the field arrangement has been demonstrated. The relevance of these calculations to a variety of problems, including the design and behavior of superparamagnetic and ferromagnetic contrast materials, and to the effects of susceptibility variations arising from metal deposits or air-tissue interfaces in NMR imaging is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Modified Spin-Echo Method for Measuring Nuclear Relaxation Times
Meiboom, S., & Gill, D. (1958) · Review of Scientific Instruments · doi:10.1063/1.1716296 · Cited by 6,022
Principles of Magnetic Resonance
Slichter, C. P. (1990) · Springer Series in Solid-State Sciences · doi:10.1007/978-3-662-09441-9 · Cited by 5,520
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,085
Bloch Equations with Diffusion Terms
Torrey, H. C. (1956) · Physical Review · doi:10.1103/physrev.104.563 · Cited by 1,216
Stejskal, E. O. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1696526 · Cited by 894
Restricted Self-Diffusion of Protons in Colloidal Systems by the Pulsed-Gradient, Spin-Echo Method
Tanner, J. E., & Stejskal, E. O. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670306 · Cited by 867
Intracranial hematomas: imaging by high-field MR.
Gomori, J. M., Grossman, R. I., Goldberg, H. I., Zimmerman, R. A., & Bilaniuk, L. T. (1985) · Radiology · doi:10.1148/radiology.157.1.4034983 · Cited by 731
Spectral Diffusion Decay in Spin Resonance Experiments
Klauder, J. R., & Anderson, P. W. (1962) · Physical Review · doi:10.1103/physrev.125.912 · Cited by 727
Cited by
Theory of NMR signal behavior in magnetically inhomogeneous tissues: The static dephasing regime
Yablonskiy, D. A., & Haacke, E. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320610 · Cited by 1,198
Perfusion imaging with NMR contrast agents
Rosen, B. R., Belliveau, J. W., Vevea, J. M., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140211 · Cited by 1,151
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Microscopic susceptibility variation and transverse relaxation: Theory and experiment
Weisskoff, R., Zuo, C. S., Boxerman, J. L., & Rosen, B. R. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310605 · Cited by 715
Functional cerebral imaging by susceptibility‐contrast NMR
Belliveau, J. W., Rosen, B. R., Kantor, H. L., Rzedzian, R. R., Kennedy, D. N., McKinstry, R. C., Vevea, J. M., Cohen, M. S., Pykett, I. L., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140311 · Cited by 570
Intravascular susceptibility contrast mechanisms in tissues
Kennan, R. P., Zhong, J., & Gore, J. C. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310103 · Cited by 524
Self-citationMolecular diffusion, tissue microdynamics and microstructure
Bihan, D. L. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080711 · Cited by 497
NMR survey of reflected Brownian motion
Grebenkov, D. S. (2007) · Reviews of Modern Physics · doi:10.1103/revmodphys.79.1077 · Cited by 421
Fisel, C. R., Ackerman, J. L., Buxton, R. B., Garrido, L., Belliveau, J. W., Rosen, B. R., & Brady, T. J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170206 · Cited by 356
Pitfalls in MR measurement of tissue blood flow with intravascular tracers: Which mean transit time?
Weisskoff, R. M., Chesler, D., Boxerman, J. L., & Rosen, B. R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290420 · Cited by 335
Contrast agents and cerebral hemodynamics
Rosen, B. R., Belliveau, J. W., Buchbinder, B. R., McKinstry, R. C., Porkka, L. M., Kennedy, D. N., Neuder, M. S., Fisel, C. R., Aronen, H. J., Kwong, K. K., et al. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910190216 · Cited by 290
On T2‐shortening by strongly magnetized spheres: A partial refocusing model
Gillis, P., Moiny, F., & Brooks, R. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10059 · Cited by 270
Water diffusion and exchange as they influence contrast enhancement
Donahue, K. M., Weisskoff, R. M., & Burstein, D. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070114 · Cited by 270
Lee, S., Duong, T. Q., Yang, G., Iadecola, C., & Kim, S. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1107 · Cited by 263
Quantitation of intrinsic magnetic susceptibility‐related effects in a tissue matrix. Phantom study
Yablonskiy, D. A. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390312 · Cited by 245
On T2‐shortening by weakly magnetized particles: The chemical exchange model†
Brooks, R. A., Moiny, F., & Gillis, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1135 · Cited by 228
“which is obtained by integrating the square of the z-component of magnetic field, Bz~r, u! 5 ~mC/r(3)!~1 2 3 cos(2)u!, [6]”
BackgroundApplication of the static dephasing regime theory to superparamagnetic iron‐oxide loaded cells
Bowen, C. V., Zhang, X., Saab, G., Gareau, P. J., & Rutt, B. K. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10192 · Cited by 226
Diffusion MRI: Precision, accuracy and flow effects
Conturo, T. E., McKinstry, R. C., Aronovitz, J. A., & Neil, J. J. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080706 · Cited by 211
Transverse relaxivity of particulate MRI contrast media: From theories to experiments
Muller, R. N., Gillis, P., Moiny, F., & Roch, A. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910220203 · Cited by 171
Magnetoferritin: Characterization of a novel superparamagnetic MR contrast agent
Bulte, J. W. M., Douglas, T., Mann, S., Frankel, R. B., Moskowitz, B. M., Brooks, R. A., Baumgarner, C. D., Vymazal, J., Strub, M., & Frank, J. A. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040343 · Cited by 162
Metadata
- Authors
- Majumdar, S., & Gore, J. C.
- Venue
- Journal of Magnetic Resonance (1969)
- Publisher
- Elsevier BV
- Published
- 1988-06
- Volume
- 78
- Issue
- 1
- Pages
- 41-55
- ISSN
- 0022-2364 (ISSN-L)
- OpenAlex
- W2018114616
- Cited by
- 161
- References
- 18
- FWCI
- 9.38
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.