Thermodilution cardiac output: A critical analysis and review of the literature
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new technique for measurement of cardiac output by thermodilution in man
Ganz, W., Donoso, R., Marcus, H. S., Forrester, J. S., & Swan, H. J. C. (1971) · The American Journal of Cardiology · doi:10.1016/0002-9149(71)90436-x · Cited by 763
Thermodilution cardiac output determination with a single flow-directed catheter
Forrester, J. S., Ganz, W., Diamond, G., McHugh, T., Chonette, D. W., & Swan, H. J. C. (1972) · American Heart Journal · doi:10.1016/0002-8703(72)90429-2 · Cited by 501
MEASUREMENT OF CARDIAC OUTPUT IN ANÆSTHETIZED ANIMALS BY A THERMO‐DILUTION METHOD
Fegler, G. (1954) · Quarterly Journal of Experimental Physiology and Cognate Medical Sciences · doi:10.1113/expphysiol.1954.sp001067 · Cited by 406
Measurement of blood flow by thermodilution
Ganz, W., & Swan, H. J. C. (1972) · The American Journal of Cardiology · doi:10.1016/0002-9149(72)90635-2 · Cited by 374
Measurement of Cardiac Output by Thermodilution
Weisel, R. D., Berger, R. L., & Hechtman, H. B. (1975) · New England Journal of Medicine · doi:10.1056/nejm197503272921307 · Cited by 207
Tympanic Thermometry in Surgery and Anesthesia
Benzinger, M. (1969) · JAMA · doi:10.1001/jama.1969.03160210039009 · Cited by 149
Measurement of Flow in Single Blood Vessels Including Cardiac Output by Local Thermodilution
FRONĚ, A., & Ganz, V. (1960) · Circulation Research · doi:10.1161/01.res.8.1.175 · Cited by 116
Hosie, K. F. (1962) · Circulation Research · doi:10.1161/01.res.10.3.491 · Cited by 99
Cardiac output measured by thermal dilution of room temperature injectate
Evonuk, E., Imig, C. J., Greenfield, W., & Eckstein, J. W. (1961) · Journal of Applied Physiology · doi:10.1152/jappl.1961.16.2.271 · Cited by 96
The use of the thermal dilution principle for measurement of cardiac output in the rat
Cooper, T., Pinakatt, T., & Richardson, A. W. (1963) · Medical & Biological Engineering & Computing · doi:10.1007/bf02474133 · Cited by 35
Cited by
Assessment of cardiac output from systemic arterial pressure in humans
Romano, S. M., & Pistolesi, M. (2002) · Critical Care Medicine · doi:10.1097/00003246-200208000-00027 · Cited by 616
Noninvasive Doppler determination of cardiac output in man. Clinical validation.
Huntsman, L. L., Stewart, D. K., Barnes, S. R., Franklin, S. B., Colocousis, J. S., & Hessel, E. A. (1983) · Circulation · doi:10.1161/01.cir.67.3.593 · Cited by 595
Zöllner, C., Haller, M., Weis, M., Mörstedt, K., Lamm, P., Kilger, E., & Goetz, A. E. (2000) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(00)90003-x · Cited by 375
HARMS, M. P. M., WESSELING, K. H., POTT, F., JENSTRUP, M., VAN GOUDOEVER, J., SECHER, N. H., & VAN LIESHOUT, J. J. (1999) · Clinical Science · doi:10.1042/cs0970291 · Cited by 345
Partial CO2 Rebreathing Indirect Fick Technique for Non-Invasive Measurement of Cardiac Output
Haryadi, D. G., Orr, J. A., Kuck, K., McJames, S., & Westenskow, D. R. (2000) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1011403717822 · Cited by 328
Errors in the measurement of cardiac output by thermodilution
Nishikawa, T., & Dohi, S. (1993) · Canadian Journal of Anaesthesia · doi:10.1007/bf03011312 · Cited by 302
Van De Water, J. M., Miller, T. W., Vogel, R. L., Mount, B. E., & Dalton, M. L. (2003) · Chest · doi:10.1378/chest.123.6.2028 · Cited by 219
Christie, J., Sheldahl, L. M., Tristani, F. E., Sagar, K. B., Ptacin, M. J., & Wann, S. (1987) · Circulation · doi:10.1161/01.cir.76.3.539 · Cited by 194
Sprangers, R. L., Wesseling, K. H., Imholz, A. L., Imholz, B. P., & Wieling, W. (1991) · Journal of Applied Physiology · doi:10.1152/jappl.1991.70.2.523 · Cited by 179
Tibby, S. M., Hatherill, M., Marsh, M. J., Morrison, G., Anderson, D., & Murdoch, I. A. (1997) · Intensive Care Medicine · doi:10.1007/s001340050443 · Cited by 178
“We chose to use CO measurements using the Fick principle via indirect calorimetry using a monitor with constant internal flow [7, 8] as our “gold-standard” because of the 10‐20 % documented variation with PA TD [9, 10 ], along with the difficulties in PATD catheter placement in the very young.”
Stroke volume equation for impedance cardiography
Bernstein, D. P., & Lemmens, H. J. M. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344724 · Cited by 165
Low oxygen delivery produced by anemia, hypoxia, and low cardiac output
Cilley, R. E., Scharenberg, A. M., Bongiorno, P. F., Guire, K. E., & Bartlett, R. H. (1991) · Journal of Surgical Research · doi:10.1016/0022-4804(91)90145-c · Cited by 54
Metadata
- Authors
- Levett, J. M., & Replogle, R. L.
- Venue
- Journal of Surgical Research
- Publisher
- Elsevier BV
- Published
- 1979-12
- Volume
- 27
- Issue
- 6
- Pages
- 392-404
- ISSN
- 0022-4804 (ISSN-L)
- OpenAlex
- W2003094126
- Cited by
- 241
- References
- 10
- FWCI
- 1.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.