Determination of monoisotopic masses and ion populations for large biomolecules from resolved isotopic distributions
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
The coupling of electrospray ionization with Fourier-transform mass spectrometry allows the analysis of large biomolecules with mass-measuring errors of less than 1 ppm. The large number of atoms incorporated in these molecules results in a low probability for the all-monoisotopic species. This produces the potential to misassign the number of heavy isotopes in a specific peak and make a mass error of ±1 Da, although the certainty of the measurement beyond the decimal place is greater than 0.1 Da. Statistical tests are used to compare the measured isotopic distribution with the distribution for a model molecule of the same average molecular mass, which allows the assignment of the monoisotopic mass, even in cases where the monoisotopic peak is absent from the spectrum. The statistical test produces error levels that are inversely proportional to the number of molecules in a distribution, which allows an estimation of the number of ions in the trapped ion cell. It has been determined, via this method that 128 charges are required to produce a signal-to-noise ratio of 3:1, which correlates well with previous experimental methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“THRASH uses a theoretical isotopomer envelope based on the average elemental composition of amino acids (averagine) [125] to compare to the experimental envelopes. A statistical score is then assigned based on the overlap of the experimental and theoretical fit.”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [125]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Matrix-assisted ultraviolet laser desorption of non-volatile compounds
Karas, M., Bachmann, D., Bahr, U., & Hillenkamp, F. (1987) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(87)87041-6 · Cited by 1,953
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
New developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
Smith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
High-resolution electrospray mass spectra of large molecules
Henry, K. D., Quinn, J. P., & McLafferty, F. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00014a043 · Cited by 309
Loo, J. A., Udseth, H. R., & Smith, R. D. (1989) · Analytical Biochemistry · doi:10.1016/0003-2697(89)90153-x · Cited by 264
A general approach to calculating isotopic distributions for mass spectrometry
Yergey, J. A. (1983) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(83)85053-0 · Cited by 222
Fourier-transform mass spectrometry of large molecules by electrospray ionization.
Henry, K. D., Williams, E. R., Wang, B. H., McLafferty, F. W., Shabanowitz, J., & Hunt, D. F. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.23.9075 · Cited by 215
Loo, J. A., Edmonds, C. G., & Smith, R. D. (1991) · Analytical Chemistry · doi:10.1021/ac00021a018 · Cited by 189
Research works printed but not linked: 2
- 1. Teer, D.; Dole, M. J. Polym. Sci. 1975, 13, 985.
- 21. Labowski, M.; Whitehouse, C. M.; Fenn, J. B. Rapid Commun. Mass Spectrom. 1993, 7, 71.
Cited by
Items 301–400 of 455
Froehlich, B. C., Popp, R., Sobsey, C. A., Ibrahim, S., LeBlanc, A. M., Mohammed, Y., Aguilar‐Mahecha, A., Poetz, O., Chen, M. X., Spatz, A., et al. (2020) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.202000034 · Cited by 9
Approximating Isotope Distributions of Biomolecule Fragments
Goldfarb, D., Lafferty, M. J., Herring, L. E., Wang, W. W., & Major, M. B. (2018) · ACS Omega · doi:10.1021/acsomega.8b01649 · Cited by 12
Palasser, M., & Breuker, K. (2024) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.4c00236 · Cited by 12
Shifting unoccupied spectral space in mass spectrum of peptide fragment ions
Bajrami, B., Shi, Y., Lapierre, P., & Yao, X. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.07.005 · Cited by 9
“0543052 u that is statistically obtained by sampling all of the amino acids in naturallyoccurring proteins [8].”
BackgroundMethodInfluentialTopMSV: A Web-Based Tool for Top-Down Mass Spectrometry Data Visualization
Choi, I. K., Jiang, T., Kankara, S. R., Wu, S., & Liu, X. (2021) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.0c00460 · Cited by 10
Maleknia, S. D., & Downard, K. M. (2005) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2005.08.002 · Cited by 10
Sun, Y., Zhang, J., Braga-Neto, U., & Dougherty, E. R. (2011) · Bioinformatics · doi:10.1093/bioinformatics/btr675 · Cited by 9
Managa, M., Ngoy, B. P., Mafukidze, D. M., Britton, J. E., & Nyokong, T. (2017) · Journal of Photochemistry and Photobiology A Chemistry · doi:10.1016/j.jphotochem.2017.08.033 · Cited by 11
Toward Efficient Analysis of >70 kDa Proteins with 100% Sequence Coverage
Forbes, A. J., Mazur, M. T., Kelleher, N. L., Patel, H. M., & Walsh, C. T. (2001) · European Journal of Mass Spectrometry · doi:10.1255/ejms.393 · Cited by 9
Assignment of coronavirus spike protein site-specific glycosylation using GlycReSoftPreprint
Klein, J., & Zaia, J. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.05.31.125302 · Cited by 9
Prostko, P., Radziński, P., Ciach, M. A., Liu, Y., Startek, M. P., Lermyte, F., Vijlder, T. D., Gambin, A., Appeltans, S., & Valkenborg, D. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.3c04351 · Cited by 8
Jia, G., Gao, J., Yang, F., Tianyu, F., & Wang, C. (2022) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/bs.mie.2021.10.013 · Cited by 8
Chen, Y.-F., Chang, C. A., Lin, Y.-H., & Tsay, Y. (2013) · Analytical Biochemistry · doi:10.1016/j.ab.2013.05.018 · Cited by 8
Jing, L., & Amster, I. J. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2009.02.011 · Cited by 8
Fabrik, I., Link, M., Härtlová, A., Daňková, V., Řehulka, P., & Stulík, J. (2013) · Journal of Proteome Research · doi:10.1021/pr4007798 · Cited by 8
Ghavidel, F. Z., Mertens, I., Baggerman, G., Laukens, K., Burzykowski, T., & Valkenborg, D. (2014) · Journal of Proteomics · doi:10.1016/j.jprot.2013.12.013 · Cited by 8
Proteoform characterization based on top-down mass spectrometry
Zhong, J., Sun, Y., Xie, M., Peng, W., Zhang, C., Wu, F., & Wang, J. (2020) · Briefings in Bioinformatics · doi:10.1093/bib/bbaa015 · Cited by 11
Optimal analysis of complex protein mass spectra
Dijkstra, M., & Jansen, R. C. (2009) · PROTEOMICS · doi:10.1002/pmic.200701064 · Cited by 8
“derived a model amino acid ‘‘averagine’’ [20].”
Gutenbrunner, P., Kyriakidou, P., Welker, F., & Cox, J. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.09.04.458985 · Cited by 10
“Isotope patterns are found based on correlation to the averagine model 25 .”
MethodŁącki, M. K., Lermyte, F., Miasojedow, B., Startek, M. P., Sobott, F., Valkenborg, D., & Gambin, A. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b01479 · Cited by 8
Advancing Intact Protein Quantitation with Updated Deconvolution Routines
Robey, M. T., Utley, D., Greer, J. B., Fellers, R. T., Kelleher, N. L., & Durbin, K. R. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.3c02345 · Cited by 7
Sotomayor, B., Donahue, T. C., Mahajan, S. P., Taw, M. N., Hulbert, S. W., Bidstrup, E. J., Owitipana, D. N., Pang, A., Xu, Y., Ghosal, S., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-61440-7 · Cited by 9
Yang, W., Ivanov, D. G., & Kaltashov, I. A. (2022) · mAbs · doi:10.1080/19420862.2022.2103906 · Cited by 7
Bi-Linear Regression for 18O Quantification: Modeling across the Elution Profile
Eckel‐Passow, J. E. (2010) · Journal of Proteomics & Bioinformatics · doi:10.4172/jpb.1000158 · Cited by 7
“Eckel-Passow and colleagues used averagine (Senko et al., 1995) to estimate the expected isotopic distribution, which does not require that the amino acid sequence be known.”
BackgroundAgten, A., Prostko, P., Geubbelmans, M., Liu, Y., Vijlder, T. D., & Valkenborg, D. (2021) · Metabolites · doi:10.3390/metabo11060400 · Cited by 7
“[36] that scales the elemental composition of an average amino acid, denoted as averagine.”
BackgroundLermyte, F., Dittwald, P., Claesen, J., Baggerman, G., Sobott, F., O’Connor, P. B., Laukens, K., Hooyberghs, J., Gambin, A., & Valkenborg, D. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b02682 · Cited by 8
Comment on the uncertainties in isotope patterns of molecules
Meija, J., & Mester, Z. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.09.029 · Cited by 7
Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (2000) · Wiley eBooks · doi:10.1002/9780470027318.a6006m · Cited by 8
Taylor, P. K., Kurtz, D. M. J., & Amster, I. J. (2001) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(01)00454-7 · Cited by 7
Matthiesen, R. (2019) · Methods in molecular biology · doi:10.1007/978-1-4939-9744-2_2 · Cited by 6
Mass spectrometric analysis of protein species of biologics
Richter, V., Kwiatkowski, M., Omidi, M., Omidi, A., Robertson, W. D., & Schlüter, H. (2013) · Pharmaceutical Bioprocessing · doi:10.4155/pbp.13.39 · Cited by 6
Hu, A. K., Lu, Y. Y., Bilmes, J., & Noble, W. S. (2018) · Journal of Proteome Research · doi:10.1021/acs.jproteome.8b00365 · Cited by 7
Vutov, V., & Dickhaus, T. (2022) · Biometrical Journal · doi:10.1002/bimj.202100328 · Cited by 6
MAZIE: A mass and charge inference engine to enhance database searching of tandem mass spectra
Victor, K. G., Murgai, M., Lyons, C. E., Templeton, T. A. B., Moshnikov, S. А., & Templeton, D. J. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.09.007 · Cited by 7
“Second, employing the concept of the “averagine” average amino acid [12], the peptide was treated as if a single average element was its sole constituent and that this average element had a single heavy isotope, instead of including in the calculation the explicit contribution for each of the elemental constituents (c…”
MethodShinkawa, T., Nagano, K., Inomata, N., & Haramura, M. (2009) · Journal of Proteomics · doi:10.1016/j.jprot.2009.08.009 · Cited by 6
pyBinder: Quantitation to Advance Affinity Selection-Mass Spectrometry
Brown, J. S., Lee, M. A., Vuong, W., Loas, A., & Pentelute, B. L. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.4c04445 · Cited by 6
Henning, S., Mormann, M., Peter‐Katalinić, J., & Pohlentz, G. (2010) · Amino Acids · doi:10.1007/s00726-010-0671-7 · Cited by 5
“Molecular weights of full-size HbA of Patagonian cavy and Persian gazelle were determined by mass deconvolution (Senko et al. 1995) of the centroid distribution in a Gaussian shaped envelope with base line separation of isotopically resolved multiprotonated species (Fig.”
MethodOkawa, S., Fischer, B., & Krijgsveld, J. (2013) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.6551 · Cited by 5
“Isotope patterns have been used for various purposes such as charge state assignment,([15]) determination of monoisotopic mass and deisotoping,([16]) filtering of nonpeptide features,([17]) estimation of protein turnover rate,([18]) and detection of peptides containing particular atoms such as mercury.”
MethodConditional Fragment Ion Probabilities Improve Database Searching for Nonmonoisotopic Precursors
O’Brien, J. J., Gadzuk-Shea, M. M., Seitzer, P., Rad, R., McAllister, F. E., & Schweppe, D. K. (2022) · Journal of Proteome Research · doi:10.1021/acs.jproteome.2c00247 · Cited by 5
“While the mono-isotopic mass of the precursor can be estimated by searching for more precursor offsets or by incorporating monoisotopic peak estimation, 3,6,10 the effect on fragment isotopic distributions has not been widely explored for peptide spectral matching.”
Siqueira, E., Kim, B.-H., Reser, L., Chow, R. L., Delaney, K., Esteller, M., Ross, M., Shabanowitz, J., Hunt, D. F., Guil, S., et al. (2023) · Epigenetics · doi:10.1080/15592294.2023.2276425 · Cited by 4
“The targeted MS2 spectra were deconvolved using the Xtract algorithm (Thermo Scientific) [37] and manually annotated.”
MethodBreuker, K. (2014) · Physical chemistry in action · doi:10.1007/978-3-642-54842-0_7 · Cited by 7
Criscione, A., Cunsolo, V., Tumino, S., Francesco, A. D., Bordonaro, S., Muccilli, V., Saletti, R., & Marletta, D. (2018) · Amino Acids · doi:10.1007/s00726-018-2555-1 · Cited by 6
Cederkvist, F. H., Mormann, M., Froesch, M., Eijsink, V. G. H., Sørlie, M., & Peter‐Katalinić, J. (2010) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2010.10.031 · Cited by 5
Matching isotopic distributions from metabolically labeled samples
McIlwain, S. J., Page, D., Huttlin, E. L., & Sussman, M. R. (2008) · Bioinformatics · doi:10.1093/bioinformatics/btn190 · Cited by 5
“We also create features that are the ratio of the difference over the light m/z and mass, respectively.”
BackgroundMethodZhang, J., Xu, D. H., Gao, W., Lin, G., & He, S. (2009) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4272 · Cited by 5
Palmblad, M., & Bergquist, J. (2003) · Journal of chromatography library · doi:10.1016/s0301-4770(03)80012-x · Cited by 5
Comment on “Computation of Isotopic Peak Center-Mass Distribution by Fourier Transform”
Hu, H., Dittwald, P., Zaia, J., & Valkenborg, D. (2013) · Analytical Chemistry · doi:10.1021/ac402731h · Cited by 5
Data Processing in Bottom‐Up Hydrogen Exchange Mass Spectrometry
Sarpe, V., & Schriemer, D. C. (2016) · Wiley eBooks · doi:10.1002/9781118703748.ch3 · Cited by 5
Chen, B., Wei, B., Dai, L., Wang, J., Kou, D., & Zhang, K. (2025) · Analytica Chimica Acta · doi:10.1016/j.aca.2025.344218 · Cited by 5
Wang, Z., Chen, X., Deng, L., Li, W., Wong, Y.-L. E., & Chan, T. ‐. D. (2015) · European Journal of Mass Spectrometry · doi:10.1255/ejms.1386 · Cited by 4
Kakourou, A., Vach, W., Nicolardi, S., van der Burgt, Y. E. M., & Mertens, B. J. A. (2016) · Statistical Applications in Genetics and Molecular Biology · doi:10.1515/sagmb-2016-0005 · Cited by 4
Zhong, J., Song, X., & Wang, S. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.4c00152 · Cited by 4
Lebedev, V. V., Yarykin, D. I., & Buryak, A. K. (2024) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.4c00153 · Cited by 4
Pesavento, J. J., Bindra, M. S., Das, U., Rommelfanger, S. R., Zhou, M., Paša‐Tolić, L., & Umen, J. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.4c02650 · Cited by 4
Miyaguchi, H., Yamamuro, T., Ohta, H., Nakahara, H., & Suzuki, S. (2015) · Journal of Agricultural and Food Chemistry · doi:10.1021/acs.jafc.5b03703 · Cited by 4
Laguillo-Gómez, A., Calvo, E., Martin-Cofreces, N. B., Lozano-Prieto, M., Sánchez‐Madrid, F., & Vázquez, J. (2023) · Journal of Proteomics · doi:10.1016/j.jprot.2023.104968 · Cited by 4
Protamines and the sperm nuclear basic proteins Pandora’s Box of insects
Leyden, M. R., Gowen, B. E., González‐Romero, R., Eirin-Lopez, J. M., Kim, B.-H., Hayashi, F., McCartney, J., Zhang, P. C., Kubo‐Irie, M., Shabanowitz, J., et al. (2024) · Biochemistry and Cell Biology · doi:10.1139/bcb-2023-0363 · Cited by 4
Tay, A. P., Liang, A., Hamey, J. J., Hart‐Smith, G., & Wilkins, M. R. (2019) · PROTEOMICS · doi:10.1002/pmic.201800444 · Cited by 7
McGee, W. M., Faron, M. L., Neil, J. R., Kronewitter, S. R., Buchan, B. W., Ledeboer, N. A., & Stephenson, J. L. (2020) · Clinical mass spectrometry · doi:10.1016/j.clinms.2020.07.001 · Cited by 4
Robust MS quantification method for phospho-peptides using 18O/16O labeling
Andersen, C. A. F., Gotta, S., Magnoni, L., Raggiaschi, R., Kremer, A., & Terstappen, G. C. (2009) · BMC Bioinformatics · doi:10.1186/1471-2105-10-141 · Cited by 5
Modeling of isotopomeric cluster of the molecular ion
Gorączko, A. J. (2007) · Journal of Molecular Modeling · doi:10.1007/s00894-007-0206-7 · Cited by 4
Ghavidel, F. Z., Claesen, J., Burzykowski, T., & Valkenborg, D. (2013) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-013-0773-z · Cited by 5
Pevzner, P. A. (2000) · The MIT Press eBooks · doi:10.7551/mitpress/2022.003.0012 · Cited by 4
Marshall, A. G., Emmett, M. R., Freitas, M. A., Hendrickson, C. L., & Zhang, Z. (2000) · Humana Press eBooks · doi:10.1007/978-1-59259-719-2_3 · Cited by 4
Redox poise in R. rubrum phototrophic growth drives large-scale changes in macromolecular pathways
Cannon, W. R., King, E., Huening, K. A., & North, J. A. (2025) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1013015 · Cited by 3
A Fast Neural Network for Isotopic Charge State Assignment
Pavek, J. G., Bollis, N. E., Grimes, J., Shortreed, M. R., Smith, L. M., & Marty, M. T. (2025) · Journal of the American Chemical Society · doi:10.1021/jacs.5c03162 · Cited by 3
Lieu, L. B., Huang, J., Kline, J. T., Bergen, D., McAlister, G. C., Durbin, K. R., Mullen, C., Melani, R. D., & Fornelli, L. (2026) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.6c00016 · Cited by 3
Gao, S., Koch, B. P., Kümmel, S., Tebben, J., & Lechtenfeld, O. J. (2026) · Science Advances · doi:10.1126/sciadv.aee5238 · Cited by 3
Computed Vibrational Heat Capacities for Gas-Phase Biomolecular Ions
Paris, L., Green, A. W., & Prell, J. S. (2025) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.5c00008 · Cited by 3
Multi-reflecting TOF MS for analyzing proteins
Verenchikov, A. N., Kirillov, S. N., Vorobyev, A., & Makarov, V. V. (2024) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2024.117389 · Cited by 3
Bondarenko, A. A., Vlasova, Y. S., Polynski, M. V., Ilyushenkova, V. V., & Ananikov, V. P. (2022) · Inorganic Chemistry Frontiers · doi:10.1039/d2qi01098d · Cited by 3
Agten, A., Vilenne, F., Prostko, P., & Valkenborg, D. (2023) · PROTEOMICS · doi:10.1002/pmic.202300154 · Cited by 4
“To this end, several estimation procedures have been developed in the past decades [5–10].”
MethodMaleknia, S. D., & Green, D. C. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2009.10.005 · Cited by 3
Demirev, P. A., & Fenselau, C. (2002) · European Journal of Mass Spectrometry · doi:10.1255/ejms.485 · Cited by 3
McGee, W. M., Verma, A., Viirtola, M., Kronewitter, S. R., Neil, J. R., & Stephenson, J. L. (2021) · Journal of Mass Spectrometry and Advances in the Clinical Lab · doi:10.1016/j.jmsacl.2021.05.001 · Cited by 5
“Deconvolution of intact protein mass spectra was performed using the Xtract software from the Averagine model [52], set for low sulfur content.”
MethodSolovyeva, E. M., Moshkovskii, S. A., & Gorshkov, M. V. (2020) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.0c00281 · Cited by 3
Leyden, M. R., Michalik, P., Baruffaldi, L., Mahmood, S., Kalani, L., Hunt, D. F., Eirin-Lopez, J. M., Andrade, M. C. B., Shabanowitz, J., & Ausió, J. (2024) · Development · doi:10.1242/dev.203134 · Cited by 2
Automating Middle-Down Mass Spectrometry Analysis for Extensive Antibody Characterization
Carfagno, A. K., Lieu, L. B., Kline, J. T., Fornelli, L., & Durbin, K. R. (2026) · Analytical Chemistry · doi:10.1021/acs.analchem.5c06408 · Cited by 2
PepPre: Promote Peptide Identification Using Accurate and Comprehensive Precursors
Tarn, C., Wu, Y., & Wang, K. (2023) · Journal of Proteome Research · doi:10.1021/acs.jproteome.3c00293 · Cited by 2
Easterling, M. L., & Agar, J. N. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814013-0.00003-x · Cited by 6
Screening of herbal medicines for potential allopathic antidiabetic adulterants: An analytical study
Mathaiyan, J., Pamidimarri, G., Manikandan, S., Rajan, S. S., & Batmanabane, G. (2019) · AYU (An International Quarterly Journal of Research in Ayurveda) · doi:10.4103/ayu.ayu_227_19 · Cited by 2
“Monoisotopic mass was considered as an initial mass of all the analytes since all were small molecules.[20]”
BackgroundApplications in Data-Intensive Computing
Shah, A. R., Adkins, J., Baxter, D. J., Cannon, W. R., Chavarría-Miranda, D., Choudhury, S., Gorton, I., Gracio, D. K., Halter, T. D., Jaitly, N., et al. (2010) · Advances in computers · doi:10.1016/s0065-2458(10)79001-x · Cited by 2
Mono-isotope prediction for mass spectra using Bayes network
Li, H., Liu, C., Rwebangira, M. R., & Burge, L. (2014) · Tsinghua Science & Technology · doi:10.1109/tst.2014.6961030 · Cited by 2
“For example, Senko et al. [11] introduced a notion of an “average” amino acid called averagine and suggested a computational method to determine mono-isotopic masses using it.”
MethodBurzykowski, T., Claesen, J., & Valkenborg, D. (2016) · Springer eBooks · doi:10.1007/978-3-319-45809-0_3 · Cited by 2
iTop-Q: an Intelligent Tool for Top-down Proteomics Quantitation Using DYAMOND Algorithm
Chang, H.-Y., Chen, C.-T., Ko, C.-L., Chen, Y., Chen, Y., Hsu, W., Juo, C., & Sung, T. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02343 · Cited by 2
Richardson, L. T., Brantley, M. R., & Solouki, T. (2020) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.02.036 · Cited by 2
Miyaguchi, H. (2016) · Journal of Visualized Experiments · doi:10.3791/54402 · Cited by 2
GPU-based Implementations of MM Algorithms. Application to Spectroscopy Signal Restoration
Gharbi, M., Chouzenoux, É., Pesquet, J.-C., & Duval, L. C. (2021) · European Signal Processing Conference (EUSIPCO) · doi:10.23919/eusipco54536.2021.9616274 · Cited by 2
Envemind: Accurate Monoisotopic Mass Determination Based On Isotopic Envelope
Radziński, P., Valkenborg, D., Startek, M. P., & Gambin, A. (2022) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.2c00176 · Cited by 2
Computational methods for Quantitative Peptide Mass Spectrometry
Schulz-Trieglaff, O. B. (2009) · Universitätsbibliothek der FU Berlin Hochschulschriftenstelle u. Dokumentenserver · doi:10.17169/refubium-9714 · Cited by 2
“In this case, we estimate this distribution using so-called averagines (Senko et al., 1995a).”
MethodGa+ TOF-SIMS lineshape analysis for resolution enhancement of MALDI MS spectra of a peptide mixture
Malyarenko, D. I., Chen, H., Wilkerson, A., Tracy, E. R., Cooke, W. E., Manos, D. M., Sasinowski, M., & Semmes, O. J. (2004) · Applied Surface Science · doi:10.1016/j.apsusc.2004.03.097 · Cited by 2
Comparison of charge state determination methods for high resolution mass spectra
Kaur, P., & O’Connor, P. B. (2006) · IEEE International Conference on Granular Computing (GrC) · doi:10.1109/grc.2006.1635862 · Cited by 2
Quantification of the necessary labelling input in protein stable isotope probingPreprint
Starke, R. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.06.02.129254 · Cited by 2
Payne, T. G. (2011) · University of Birmingham Institutional Research Archive (University of Birmingham) · Cited by 2
Karalia, S., Engholm‐Keller, K., Poojary, M. M., Raak, N., & Lund, M. A. V. (2026) · Food Chemistry · doi:10.1016/j.foodchem.2026.149767 · Cited by 1
Hinkle, J. D., DeFiglia, S. A., D’Ippolito, R. A., Mullen, C., Blakney, G. T., Yip, P. F., Huguet, R., Håkansson, H., Shabanowitz, J., Hunt, D. F., et al. (2026) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.6c00257 · Cited by 1
Zhu, Q., & Burzykowski, T. (2011) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-010-0056-x · Cited by 1
“[14], the method allows for the isotopic distribution to be estimated from the data and thus accounting for the possible deviation around the average isotopic distribution.”
MethodEnhancing the stability of 18O-labeled peptides through removal of immobilized trypsin by ZipTips
Li, M., Peng, F., Zuo, J.-H., Yi, H. L., Tang, C., Li, C., Zhang, P., Chen, Z., & Xiao, Z. (2010) · Analytical Biochemistry · doi:10.1016/j.ab.2010.08.035 · Cited by 1
Fourier Transform Ion Cyclotron Resonance Mass Spectrometry in the Analysis of Peptides and Proteins
Cooper, H. J. (2009) · CRC Press eBooks · doi:10.1201/9781420083743-c5 · Cited by 1
Application of the half decimal place rule to increase the peptide identification rate
Koehler, C. J., Bollineni, R. C., & Thiede, B. (2016) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.7780 · Cited by 1
Metadata
- Authors
- Senko, M. W., Beu, S. C., & McLaffertycor, F. W.
- Affiliations
- Cornell University (US)
- ORCID
- Senko, Michael W.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1995-04-01
- Volume
- 6
- Issue
- 4
- Pages
- 229-233
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2086502504
- Semantic Scholar
- 94b2dabffe606cc05171d713f5c8c92da73345ca
- Cited by
- 451
- References
- 24
- Citations by year
- 2026: 12 · 2025: 14 · 2024: 19 · 2023: 12 · 2022: 11 · 2021: 19 · 2020: 28 · 2019: 18 · 2018: 16 · 2017: 23 · 2016: 20 · 2015: 17 · 2014: 21 · 2013: 22 · 2012: 15
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the American Society for Mass Spectrometry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- isotopic distribution, large biomolecules, electrospray ionization, Fourier transform mass spectrometry, statistical tests, signal-to-noise ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.