Determination of monoisotopic masses and ion populations for large biomolecules from resolved isotopic distributions
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
The coupling of electrospray ionization with Fourier-transform mass spectrometry allows the analysis of large biomolecules with mass-measuring errors of less than 1 ppm. The large number of atoms incorporated in these molecules results in a low probability for the all-monoisotopic species. This produces the potential to misassign the number of heavy isotopes in a specific peak and make a mass error of ±1 Da, although the certainty of the measurement beyond the decimal place is greater than 0.1 Da. Statistical tests are used to compare the measured isotopic distribution with the distribution for a model molecule of the same average molecular mass, which allows the assignment of the monoisotopic mass, even in cases where the monoisotopic peak is absent from the spectrum. The statistical test produces error levels that are inversely proportional to the number of molecules in a distribution, which allows an estimation of the number of ions in the trapped ion cell. It has been determined, via this method that 128 charges are required to produce a signal-to-noise ratio of 3:1, which correlates well with previous experimental methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“THRASH uses a theoretical isotopomer envelope based on the average elemental composition of amino acids (averagine) [125] to compare to the experimental envelopes. A statistical score is then assigned based on the overlap of the experimental and theoretical fit.”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [125]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Matrix-assisted ultraviolet laser desorption of non-volatile compounds
Karas, M., Bachmann, D., Bahr, U., & Hillenkamp, F. (1987) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(87)87041-6 · Cited by 1,953
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
New developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
Smith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
High-resolution electrospray mass spectra of large molecules
Henry, K. D., Quinn, J. P., & McLafferty, F. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00014a043 · Cited by 309
Loo, J. A., Udseth, H. R., & Smith, R. D. (1989) · Analytical Biochemistry · doi:10.1016/0003-2697(89)90153-x · Cited by 264
A general approach to calculating isotopic distributions for mass spectrometry
Yergey, J. A. (1983) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(83)85053-0 · Cited by 222
Fourier-transform mass spectrometry of large molecules by electrospray ionization.
Henry, K. D., Williams, E. R., Wang, B. H., McLafferty, F. W., Shabanowitz, J., & Hunt, D. F. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.23.9075 · Cited by 215
Loo, J. A., Edmonds, C. G., & Smith, R. D. (1991) · Analytical Chemistry · doi:10.1021/ac00021a018 · Cited by 189
Research works printed but not linked: 2
- 1. Teer, D.; Dole, M. J. Polym. Sci. 1975, 13, 985.
- 21. Labowski, M.; Whitehouse, C. M.; Fenn, J. B. Rapid Commun. Mass Spectrom. 1993, 7, 71.
Cited by
Items 201–300 of 455
Towards a routine application of Top-Down approaches for label-free discovery workflows
Schmit, P.-O., Vialaret, J., Wessels, H. J. C. T., van Gool, A. J., Lehmann, S., Gabelle, A., Wood, J., Bern, M. W., Paape, R., Suckau, D., et al. (2017) · Journal of Proteomics · doi:10.1016/j.jprot.2017.08.003 · Cited by 25
“We further highlight the high mass accuracy and good isotopic fidelity of this method that enables the secure assignment of monoisotopic molecular weights [26], [27], [28].”
Jeong, K., Babović, M., Gorshkov, V., Kim, J., Jensen, O. N., & Kohlbacher, O. (2022) · Nature Communications · doi:10.1038/s41467-022-31922-z · Cited by 27
Cappadona, S., Muñoz, J., Spee, W., Low, T. Y., Mohammed, S., van Breukelen, B., & Heck, A. J. R. (2011) · Journal of Proteomics · doi:10.1016/j.jprot.2011.04.022 · Cited by 28
“First, the averagine model [7] was used to estimate peptide isotopic distributions and tomodel the predictable quantification error at increasing masses and differential expressions.”
MethodInfluentialAutomated Data Extraction from In Situ Protein-Stable Isotope Probing Studies
Slysz, G., Steinke, L., Ward, D. M., Klatt, C. G., Clauss, T. R., Purvine, S. O., Payne, S., Anderson, G., Smith, R. D., & Lipton, M. S. W. (2014) · Journal of Proteome Research · doi:10.1021/pr400633j · Cited by 22
Touchard, A., Déjean, A., Escoubas, P., & Orivel, J. (2015) · Journal of Hymenoptera Research · doi:10.3897/jhr.47.6804 · Cited by 22
“The value is derived from the statistical occurrence of amino acids in proteins (Senko et al. 1995), and calculated with the formula C4.”
MethodC-Terminal Cu II Coordination to α-Synuclein Enhances Aggregation
Abeyawardhane, D. L., Heitger, D. R., Fernández, R. D., Forney, A. K., & Lucas, H. R. (2018) · ACS Chemical Neuroscience · doi:10.1021/acschemneuro.8b00448 · Cited by 23
Identification of Peptide Features in Precursor Spectra Using Hardklör and Krönik
Hoopmann, M. R., MacCoss, M. J., & Moritz, R. L. (2012) · Current Protocols in Bioinformatics · doi:10.1002/0471250953.bi1318s37 · Cited by 26
“These tools employ many analytical techniques, including separating signal from background noise, calculation of ionic charge state, modeling of isotope distributions, and solving multiple signals (Senko et al., 1995a; Senko et al., 1995b; Rockwood et al., 1995; Kubinyi, 1991; Mann et al., 1989).”
MethodShi, Y., Bajrami, B., & Yao, X. (2009) · Analytical Chemistry · doi:10.1021/ac9008034 · Cited by 22
Pourshahian, S., & Limbach, P. A. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1391 · Cited by 22
Improved peptide sequencing using isotope information inherent in tandem mass spectra
Cannon, W. R., & Jarman, K. D. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1119 · Cited by 22
Multipurpose Dissociation Cell for Enhanced ETD of Intact Protein Species
Rose, C. M., Russell, J. D., Ledvina, A. R., McAlister, G. C., Westphall, M. S., Griep‐Raming, J., Schwartz, J. C., Coon, J. J., & Syka, J. E. P. (2013) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-013-0622-0 · Cited by 21
Xiao, H., Cao, X., Wang, L., Run, X., Su, Y., Cheng, T., Sheng-gang, S., & Liang, Z. (2011) · PubMed · Cited by 25
High-throughput peptide quantification using mTRAQ reagent triplex
Yoon, J. Y., Yeom, J., Lee, H., Kim, K., Na, S., Park, K., Paek, E., & Lee, C. (2011) · BMC Bioinformatics · doi:10.1186/1471-2105-12-s1-s46 · Cited by 21
“56% according to an averagine model [23].”
Using dynamic programming to create isotopic distribution maps from mass spectra
McIlwain, S. J., Page, D., Huttlin, E. L., & Sussman, M. R. (2007) · Bioinformatics · doi:10.1093/bioinformatics/btm198 · Cited by 25
Sriswasdi, S., Harper, S. L., Tang, H., & Speicher, D. W. (2013) · Journal of Proteome Research · doi:10.1021/pr400953w · Cited by 20
Computation of Isotopic Peak Center-Mass Distribution by Fourier Transform
Fernández-de-Cossio-Díaz, J., & Fernández-de-Cossio-Díaz, J. (2012) · Analytical Chemistry · doi:10.1021/ac301296a · Cited by 20
Lavallée‐Adam, M., Park, S. K. R., Martínez‐Bartolomé, S., He, L., & Yates, J. R. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-015-1161-7 · Cited by 20
“The RawConverter algorithm also addresses this problem by combining the Averagine model [41] and the information of successive MS1 scans to select the monoisotopic peak for each precursor ion.”
MethodValkenborg, D., Pryseley, A., Thomas, G. R., Krols, L., Kas, K., & Burzykowski, T. (2007) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3237 · Cited by 20
A novel comprehensive wave-form MS data processing method
Chen, S., Li, M., Hong, D., Billheimer, D. D., Hui-ming, L., Xu, B. J., & Shyr, Y. (2009) · Bioinformatics · doi:10.1093/bioinformatics/btp060 · Cited by 20
Basharat, A. R., Ning, X., & Liu, X. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00903 · Cited by 20
Mojumdar, A., Yoo, H.-J., Kim, D., Park, J., Park, S., Jeon, E., Choi, S., Choi, J. H., Park, M., Bang, G., et al. (2024) · Journal of Analytical Science & Technology · doi:10.1186/s40543-024-00437-1 · Cited by 19
“However, in the case of pure macromolecules, it is difficult to obtain isotopically resolved spectra (Senko et al. 1995).”
BackgroundNagel, T., & Meyer, B. (2014) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2014.09.021 · Cited by 19
Wong, J. W. H., Schwahn, A. B., & Downard, K. M. (2010) · BMC Bioinformatics · doi:10.1186/1471-2105-11-266 · Cited by 21
“To evaluate the composition of isotopic clusters, the model amino acid averagine (C 4.9384 H 7.7583 N 1.3577 O 1.4773 S 0.0417 ) [28] is used to define both the predicted distance between isotopic peaks and the intensity distribution of ions with an isotopic cluster.”
MethodInfluentialQuantitative Peptidomics with Five-plex Reductive Methylation labels
Tashima, A. K., & Fricker, L. D. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1852-3 · Cited by 20
Hernandez, Y. C., Boskamp, T., Casadonte, R., Hauberg‐Lotte, L., Oetjen, J., Lachmund, D., Peter, A., Trede, D., Kriegsmann, K., Kriegsmann, M., et al. (2018) · PROTEOMICS - CLINICAL APPLICATIONS · doi:10.1002/prca.201700168 · Cited by 19
Heep, J., Klaus, A., Kessel, T., Seip, M., Vilcinskas, A., & Škaljac, M. (2019) · Insects · doi:10.3390/insects10020042 · Cited by 20
“1254 Da), a theoretical average amino acid sequence based on the statistical abundance of each amino acid [55].”
BackgroundPoisson Model To Generate Isotope Distribution for Biomolecules
Sadygov, R. G. (2017) · Journal of Proteome Research · doi:10.1021/acs.jproteome.7b00807 · Cited by 20
Parallel processing of large datasets from NanoLC-FTICR-MS measurements
van der Burgt, Y. E. M., Barbu, I., Konijnenburg, M., Biskup, M., Duursma, M. C., Heeren, R. M. A., Römpp, A., van Nieuwpoort, R. V., & Bal, H. E. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.09.005 · Cited by 21
“The need for automation was already recognized after the first ESI experiments [6] and has been further developed since [7–10].”
MethodGallagher, K. J., Palasser, M., Hughes, S., Mackay, C. L., Kilgour, D. P. A., & Clarke, D. J. (2020) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.9b00119 · Cited by 19
Automatic assignment of metal-containing peptides in proteomic LC-MS and MS/MS data sets
Wootton, C. A., Lam, Y. P. Y., Willetts, M., van Agthoven, M. A., Barrow, M. P., Sadler, P. J., & O’Connor, P. B. (2017) · The Analyst · doi:10.1039/c7an00075h · Cited by 23
Curcuruto, O., Rovatti, L., Pastorino, A. M., & Hamdan, M. H. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990215)13:3 · Cited by 13
Uhlmann, K. R., Gibb, S., Kalkhof, S., Arroyo‐Abad, U., Schulz, C., Hoffmann, B., Stubbins, F. L., Carpenter, S. T., Beer, M., von Bergen�, M., et al. (2014) · Parasites & Vectors · doi:10.1186/1756-3305-7-392 · Cited by 17
“To detect monoisotopic peaks, an algorithm based on the artificial average amino acid “averagine” [52] and the isotopic-peak-ratio [53] was employed.”
Methodvan der Rest, G., Hui, R., Frison, G., & Chamot‐Rooke, J. (2011) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-011-0166-0 · Cited by 17
“Differentiation between peaks differing by 1 Da (such as (c-H) • /c or z • /(z+H)) was done based on intensity comparisons between both peaks: starting from the lowest mass peak that can be assigned to (c-H) • or z • , the intensity of the second isotopic peaks is computed based on carbon content of averagine composit…”
MethodZhang, R., Zhu, J., Lubman, D. M., Mechref, Y. S., & Tang, H. (2021) · Journal of Proteome Research · doi:10.1021/acs.jproteome.1c00245 · Cited by 20
Samgina, T. Y., Gorshkov, V., Artemenko, K. A., Vorontsov, E. A., Klykov, O. V., Ogourtsov, S. V., Zubarev, R. A., & Lebedev, А. T. (2012) · Peptides · doi:10.1016/j.peptides.2012.02.017 · Cited by 17
Averagine-Scaling Analysis and Fragment Ion Mass Defect Labeling in Peptide Mass Spectrometry
Yao, X., Diego, P. A., Ramos, A. A., & Shi, Y. (2008) · Analytical Chemistry · doi:10.1021/ac801096e · Cited by 17
Fundamentals and Advances of Orbitrap Mass Spectrometry
Ščigelová, M., & Makarov, A. (2000) · Wiley eBooks · doi:10.1002/9780470027318.a9309 · Cited by 20
Matthiesen, R. (2013) · Methods in molecular biology · doi:10.1007/978-1-62703-392-3_2 · Cited by 18
Fast Exact Computation of the k Most Abundant Isotope Peaks with Layer-Ordered Heaps
Kreitzberg, P. A., Pennington, J., Lucke, K., & Serang, O. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c01670 · Cited by 16
A Novel Algorithm for Validating Peptide Identification from a Shotgun Proteomics Search Engine
Jian, L., Niu, X., Xia, Z., Samir, P., Sumanasekera, C., Mu, Z., Jennings, J. L., Hoek, K. L., Allos, T. M., Howard, L. M., et al. (2013) · Journal of Proteome Research · doi:10.1021/pr300631t · Cited by 16
Polacco, B. J., Purvine, S. O., Zink, E., LaVoie, S. P., Lipton, M. S. W., Summers, A. O., & Miller, S. M. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.004853 · Cited by 21
“2A, box 4) computed from the target mass and average ratios of elements in peptides, denoted ‘averagine’ (14).”
MethodInfluentialHe, L., Weisbrod, C. R., & Marshall, A. G. (2017) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2017.11.012 · Cited by 16
A new scoring function for top-down spectral deconvolution
Kou, Q., Wu, S., & Liu, X. (2014) · BMC Genomics · doi:10.1186/1471-2164-15-1140 · Cited by 18
“When the chemical formula is unknown and the only available information is its monoisotopic or average mass, the wellknown averagine model [9] can be used to estimate the chemical formula from the monoisotopic or average mass.”
MethodGambin, A., Dutkowski, J., Karczmarski, J., Kluge, B., Kowalczyk, K., Ostrowski, J., Poznański, J. T., Tiuryn, J., Bakun, M., & Dadlez, M. (2006) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.06.011 · Cited by 17
Johnson, K. A., & Amster, I. J. (2001) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(01)00263-x · Cited by 16
A Fast and Accurate Algorithm for the Quantification of Peptides from Mass Spectrometry Data
Schulz-Trieglaff, O. B., Hussong, R., Gröpl, C., Hildebrandt, A., & Reinert, K. (2007) · Lecture notes in computer science · doi:10.1007/978-3-540-71681-5_33 · Cited by 34
“The averagine [25] has the molecular formula C4.”
BackgroundMethodImproving Mass Defect Filters for Human Proteins
Toumi, M. L., & Desaire, H. (2010) · Journal of Proteome Research · doi:10.1021/pr100291q · Cited by 15
Klein, O., Fogt, F., Hollerbach, S. H., Nebrich, G., Boskamp, T., & Wellmann, A. (2020) · PROTEOMICS - CLINICAL APPLICATIONS · doi:10.1002/prca.201900131 · Cited by 15
Global characterization of modifications to the charge isomers of IgG antibody
Cui, X., Mi, W., Hu, Z., Li, X., Meng, B., Zhao, X., Qian, X., Zhu, T., & Ying, W. (2020) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2020.11.006 · Cited by 15
“The reSpectTM algorithm was employed to resolve the spectra [21,22], which calculates the average mass using the form of the peak interval (used to represent the mass).”
MethodAccurate peak list extraction from proteomic mass spectra for identification and profiling studies
Barbarini, N., & Magni, P. (2010) · BMC Bioinformatics · doi:10.1186/1471-2105-11-518 · Cited by 16
“The Averagine proposed in [19] by Senko et al.”
BackgroundMethodInfluentialFernández-de-Cossío, J. (2010) · Analytical Chemistry · doi:10.1021/ac9023523 · Cited by 15
Quijada, J. V., Schmitt, N. D., Salisbury, J. P., Auclair, J. R., & Agar, J. N. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03234 · Cited by 15
Masselon, C., Kieffer‐Jaquinod, S., Brugière, S., Dupierris, V., & Garin, J. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3447 · Cited by 18
Taubert, M., von Bergen�, M., & Seifert, J. (2013) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-6828-y · Cited by 14
“% [27], has the highest influence on a peptide's isotopic distribution.”
BackgroundEsser‐Skala, W., Segl, M., Wohlschlager, T., Reisinger, V., Holzmann, J., & Huber, C. G. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02796-1 · Cited by 14
OpenPepXL: An Open-Source Tool for Sensitive Identification of Cross-Linked Peptides in XL-MS
Netz, E., Dijkstra, T. M. H., Sachsenberg, T. T., Zimmermann, L., Walzer, M., Monecke, T., Ficner, R., Dybkov, O., Urlaub, H., & Kohlbacher, O. (2020) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir120.002186 · Cited by 15
“For a given precursor mass in conventional MS-based protein identification, the length of a possibly matching linear peptide can be roughly estimated by applying an ‘averagine’ model (7).”
MethodLebede, M., Marco, F. D., Esser‐Skala, W., Hennig, R., Wohlschlager, T., & Huber, C. G. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c02199 · Cited by 16
Mass Spectrometry in Natural Product Structure Elucidation
Budzikiewicz, H. (2014) · Fortschritte der Chemie Organischer Naturstoffe/Fortschritte der Chemie organischer Naturstoffe/Progress in the chemistry of organic natural products · doi:10.1007/978-3-319-05275-5_2 · Cited by 16
IMTBX and Grppr: Software for Top-Down Proteomics Utilizing Ion Mobility-Mass Spectrometry
Avtonomov, D. M., Polasky, D. A., Ruotolo, B. T., & Nesvizhskii, A. I. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04999 · Cited by 16
On the Fine Isotopic Distribution and Limits to Resolution in Mass Spectrometry
Dittwald, P., Valkenborg, D., Claesen, J., Rockwood, A. L., & Gambin, A. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-015-1180-4 · Cited by 14
“We focus here on the fine structure of the most abundant peak of the tested polyaveragines [16] (Supplementary Table 2), which can be considered as approximations of several peptides and protomers, which are building blocks of viral capsids.”
BackgroundSinz, A., Jin, A. J., & Zschörnig, O. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.532 · Cited by 14
Lin, Y., Agarwal, A. M., Marshall, A. G., & Anderson, L. C. (2021) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.1c00291 · Cited by 13
Improved Mass Calibration in MALDI MSI Using Neural Network-Based Recalibration
Denker, A., Behrmann, J., & Boskamp, T. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.4c00304 · Cited by 13
Popovic, Z., Anderson, L. C., Zhang, X., Butcher, D. S., Blakney, G. T., Zubarev, R. A., & Marshall, A. G. (2023) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.2c00242 · Cited by 13
Kronewitter, S. R., Slysz, G., Marginean, I., Hagler, C. D., Lamarche, B. L., Zhao, R., Harris, M. Y., Monroe, M. E., Polyukh, C. A., Crowell, K. L., et al. (2014) · Analytical Chemistry · doi:10.1021/ac501492f · Cited by 13
Johnson, K. A., Verhagen, M. F. J. M., Adams, M. W. W., & Amster, I. J. (2001) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00337-7 · Cited by 13
Dufresne, C. P., Wood, T. D., & Hendrickson, C. L. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00102-0 · Cited by 13
Error tolerant searching of uninterpreted tandem mass spectrometry data
Creasy, D. M., & Cottrell, J. S. (2002) · PROTEOMICS · doi:10.1002/1615-9861(200210)2:10<1426::aid-prot1426>3.0.co;2-5 · Cited by 239
Mass spectrometry data confirming tetrameric α-synuclein N-terminal acetylation
Fernández, R. D., & Lucas, H. R. (2018) · Data in Brief · doi:10.1016/j.dib.2018.09.026 · Cited by 13
“Statistical analyses [4] of the isotopic distribution of the 17þ charge envelope verified the identification of N-terminally acetylated αS.”
BackgroundXiong, Y., Mueller, R., Feng, S., Guo, X., & Pan, C. (2024) · Microbiome · doi:10.1186/s40168-024-01866-1 · Cited by 12
“In Sipros 4, the unit mass offset range is customized according to the enrichment level of the SIP searches based on the simulation results using the poly-Averagine peptides [40].”
MethodGlycoGenius: a streamlined high-throughput glycan composition identification tool
Loponte, H. F. B. R., Zheng, J., Ding, Y., Oliveira, I. D. A., Basse, K., Todeschini, A. R., Horvatovich, P. L., & Lageveen‐Kammeijer, G. S. M. (2025) · Nature Communications · doi:10.1038/s41467-025-65265-2 · Cited by 14
Williams, B. J., Ciavarini, S. J., Devlin, C., Cohn, S. M., Xie, R., Vissers, J. P. C., Martin, L. B., Caswell, A., Langridge, J., & Geromanos, S. J. (2016) · PROTEOMICS · doi:10.1002/pmic.201500492 · Cited by 12
“The number of isotopes a precursor can generate is directly related to its elemental composition and concentration [19].”
BackgroundSparse Recovery for Protein Mass Spectrometry Data
Slawski, M., & Hein, M. (2014) · The MIT Press eBooks · doi:10.7551/mitpress/9333.003.0006 · Cited by 12
Resampling and deconvolution of linear time‐of‐flight records for enhanced protein profiling
Malyarenko, D. I., Cooke, W. E., Tracy, E. R., Drake, R. R., Shin, S. H., Semmes, O. J., Sasinowski, M., & Manos, D. M. (2006) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2496 · Cited by 12
Kinetics of a Collagen-Like Polypeptide Fragmentation after Mid-IR Free-Electron Laser Ablation
Zavalin, A. I., Hachey, D. L., Sundaramoorthy, M., Banerjee, S., Morgan, S. H., Feldman, L. C., TOLK, N. H., & Piston, D. W. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.122002 · Cited by 12
“supplied by Thermo Scientific as part of the Xcalibur software (21).”
MethodComputational Quantification of Peptides from LC-MS Data
Schulz-Trieglaff, O. B., Hussong, R., Gröpl, C., Leinenbach, A., Hildebrandt, A., Huber, C. G., & Reinert, K. (2008) · Journal of Computational Biology · doi:10.1089/cmb.2007.0117 · Cited by 12
“As mentioned above, it is straightforward to model the peak intensity pattern caused by a peptide in a mass spectrum based on the notion of an amino acid of averaged composition (Senko et al., 1995).”
InfluentialImproved Quantitative Analysis of Mass Spectrometry using Quadratic Equations
Yoon, J. Y., Lim, K. Y., Lee, S., Park, K., Paek, E., Kang, U., Yeom, J., & Lee, C. (2010) · Journal of Proteome Research · doi:10.1021/pr100183t · Cited by 12
Titulaer, M. K., Mustafa, D. A. M., Siccama, I., Konijnenburg, M., Burgers, P. C., Andeweg, A. C., Smitt, P. A. E. S., Kros, J. M., & Luider, T. M. (2008) · BMC Bioinformatics · doi:10.1186/1471-2105-9-133 · Cited by 14
“7583 (the theoretical "averagine" amino acid composition [13]), the additional constant unit "empty", the algorithm version 2.”
BackgroundMethodZhu, Q., Valkenborg, D., & Burzykowski, T. (2010) · Journal of Proteome Research · doi:10.1021/pr100169a · Cited by 12
Chen, L., & Yap, Y. L. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.10.015 · Cited by 12
“Senko and colleagues [5, 8] described a method that combines a Patterson pattern-recognition algorithm with a Fourier transform for charge determination of fragment ions from isotopically resolved collisioninduced dissociation tandem mass spectra of intact proteins in a Fourier transform ion cyclotron resonance (FTICR…”
MethodProgress in Tandem Mass Spectrometry Data Analysis for Nucleic Acids
Lanzillotti, M. B., & Brodbelt, J. S. (2025) · Mass Spectrometry Reviews · doi:10.1002/mas.21923 · Cited by 15
“Analogous to algorithmic deconvolution approaches often used to pre ‐ process MS/MS data of protein ions, this application reduces the complexity of the m/z domain data (Senko, Beu, and McLaffertycor 1995).”
Vyatkina, K., Dekker, L. J. M., Wu, S., VanDuijn, M. M., Liu, X., Tolić, N., Luider, T. M., & Paša‐Tolić, L. (2017) · PROTEOMICS · doi:10.1002/pmic.201600321 · Cited by 16
Schaffer, L. V., Anderson, L. C., Butcher, D. S., Shortreed, M. R., Miller, R., Pavelec, C. M., & Smith, L. M. (2020) · Journal of Proteome Research · doi:10.1021/acs.jproteome.0c00403 · Cited by 11
Peters-Clarke, T. M., Riley, N. M., Westphall, M. S., & Coon, J. J. (2021) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.1c00284 · Cited by 11
Exhaustive Cross-Linking Search with Protein Feedback
Zhou, C., Dai, S., Lin, Y., Lian, S., Fan, X., Li, N., & Yu, W. (2022) · Journal of Proteome Research · doi:10.1021/acs.jproteome.2c00500 · Cited by 14
Computation of the Isotopic Distribution in Two Dimensions
Fernández-de-Cossío, J. (2010) · Analytical Chemistry · doi:10.1021/ac101039x · Cited by 13
Niu, M., Mao, X., Ying, W., Qin, W., Zhang, Y., & Qian, X. (2012) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.6293 · Cited by 13
Pipelines and Systems for Threshold-Avoiding Quantification of LC–MS/MS Data
Brotons, A. S., Eriksson, J. O., Kwiatkowski, M., Wolters, J. C., Kema, I. P., Barcaru, A., Kuipers, F., Bakker, S. J. L., Bischoff, R., Suits, F., et al. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c01892 · Cited by 11
Quantitative Determination of Isotope Ratios from Experimental Isotopic Distributions
Kaur, P., & O’Connor, P. B. (2007) · Analytical Chemistry · doi:10.1021/ac061535z · Cited by 11
“Ions were generated for an “average” protein [27] with a molecular weight of 9000 Da.”
BackgroundFrahm, J. L., Mason, C. J., & Muddiman, D. C. (2004) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.02.004 · Cited by 12
Skinner, K. A., Fisher, T. D., Lee, A., Su, T., Forte, E., Sánchez, A., Caldwell, M. A., & Kelleher, N. L. (2025) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-025-06120-7 · Cited by 10
“Fragment ions were identified by matching their isotopic distributions to theoretical isotopic distributions generated using an avera-gine model [24] and the Mercury7 [25] algorithm.”
Valkenborg, D., Thomas, G. R., Krols, L., Kas, K., & Burzykowski, T. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1527 · Cited by 10
Lin, Y., Agarwal, A. M., Anderson, L. C., & Marshall, A. G. (2023) · Journal of Mass Spectrometry and Advances in the Clinical Lab · doi:10.1016/j.jmsacl.2023.01.004 · Cited by 11
“The δ/β ratios considered all detected charge states generated by positive electrospray ionization (ESI) and were calculated from m/z-to-mass deconvolved spectra [24].”
MethodElferich, J., Williamson, D. M., David, L. L., & Shinde, U. P. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01721 · Cited by 11
Bottom-up mass spectrometric sequencing of microRNA
Wambua, D. M., Ubukata, M., Dane, J., Cody, R. B., & Chiu, N. H. L. (2014) · Analytical Methods · doi:10.1039/c4ay01519c · Cited by 10
Iodine-Containing Mass-Defect-Tuned Dendrimers for Use as Internal Mass Spectrometry Calibrants
Giesen, J. A., Diament, B. J., & Grayson, S. M. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1849-y · Cited by 10
Fourier Transform Mass Spectrometry
Easterling, M. L., & Amster, I. J. (1997) · Springer eBooks · doi:10.1007/978-94-011-5165-8_15 · Cited by 10
Mass Spectrometry of Amino Acids and Proteins
Maleknia, S. D., & Johnson, R. S. (2011) · Wiley eBooks · doi:10.1002/9783527631841.ch1 · Cited by 18
ICPD-A New Peak Detection Algorithm for LC/MS
Zhang, J., & Haskins, W. E. (2010) · BMC Genomics · doi:10.1186/1471-2164-11-s3-s8 · Cited by 10
“One of the most popular is based on “ averagine ” , an averaged molecular formula for peptides [16].”
BackgroundMethodInfluentialClaesen, J., Lermyte, F., Sobott, F., Burzykowski, T., & Valkenborg, D. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01165 · Cited by 9
Metadata
- Authors
- Senko, M. W., Beu, S. C., & McLaffertycor, F. W.
- Affiliations
- Cornell University (US)
- ORCID
- Senko, Michael W.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1995-04-01
- Volume
- 6
- Issue
- 4
- Pages
- 229-233
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2086502504
- Semantic Scholar
- 94b2dabffe606cc05171d713f5c8c92da73345ca
- Cited by
- 451
- References
- 24
- Citations by year
- 2026: 12 · 2025: 14 · 2024: 19 · 2023: 12 · 2022: 11 · 2021: 19 · 2020: 28 · 2019: 18 · 2018: 16 · 2017: 23 · 2016: 20 · 2015: 17 · 2014: 21 · 2013: 22 · 2012: 15
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the American Society for Mass Spectrometry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- isotopic distribution, large biomolecules, electrospray ionization, Fourier transform mass spectrometry, statistical tests, signal-to-noise ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.