Determination of monoisotopic masses and ion populations for large biomolecules from resolved isotopic distributions
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
The coupling of electrospray ionization with Fourier-transform mass spectrometry allows the analysis of large biomolecules with mass-measuring errors of less than 1 ppm. The large number of atoms incorporated in these molecules results in a low probability for the all-monoisotopic species. This produces the potential to misassign the number of heavy isotopes in a specific peak and make a mass error of ±1 Da, although the certainty of the measurement beyond the decimal place is greater than 0.1 Da. Statistical tests are used to compare the measured isotopic distribution with the distribution for a model molecule of the same average molecular mass, which allows the assignment of the monoisotopic mass, even in cases where the monoisotopic peak is absent from the spectrum. The statistical test produces error levels that are inversely proportional to the number of molecules in a distribution, which allows an estimation of the number of ions in the trapped ion cell. It has been determined, via this method that 128 charges are required to produce a signal-to-noise ratio of 3:1, which correlates well with previous experimental methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“THRASH uses a theoretical isotopomer envelope based on the average elemental composition of amino acids (averagine) [125] to compare to the experimental envelopes. A statistical score is then assigned based on the overlap of the experimental and theoretical fit.”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [125]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Matrix-assisted ultraviolet laser desorption of non-volatile compounds
Karas, M., Bachmann, D., Bahr, U., & Hillenkamp, F. (1987) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(87)87041-6 · Cited by 1,953
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
New developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
Smith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
High-resolution electrospray mass spectra of large molecules
Henry, K. D., Quinn, J. P., & McLafferty, F. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00014a043 · Cited by 309
Loo, J. A., Udseth, H. R., & Smith, R. D. (1989) · Analytical Biochemistry · doi:10.1016/0003-2697(89)90153-x · Cited by 264
A general approach to calculating isotopic distributions for mass spectrometry
Yergey, J. A. (1983) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(83)85053-0 · Cited by 222
Fourier-transform mass spectrometry of large molecules by electrospray ionization.
Henry, K. D., Williams, E. R., Wang, B. H., McLafferty, F. W., Shabanowitz, J., & Hunt, D. F. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.23.9075 · Cited by 215
Loo, J. A., Edmonds, C. G., & Smith, R. D. (1991) · Analytical Chemistry · doi:10.1021/ac00021a018 · Cited by 189
Research works printed but not linked: 2
- 1. Teer, D.; Dole, M. J. Polym. Sci. 1975, 13, 985.
- 21. Labowski, M.; Whitehouse, C. M.; Fenn, J. B. Rapid Commun. Mass Spectrom. 1993, 7, 71.
Cited by
Items 101–200 of 455
Improved Precursor Characterization for Data-Dependent Mass Spectrometry
Hebert, A. S., Thöing, C., Riley, N. M., Kwiecien, N. W., Shiskova, E., Huguet, R., Cardasis, H. L., Kuehn, A., Eliuk, S., Zabrouskov, V., et al. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04808 · Cited by 67
Algorithms for automatic interpretation of high resolution mass spectra
Kaur, P., & O’Connor, P. B. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.11.024 · Cited by 74
“Hence, there is need for the development of advanced data analysis algorithms [15–21].”
BackgroundMethodInfluentialToward Automatic and Comprehensive Glycan Characterization by Online PGC-LC-EED MS/MS
Wei, J., Tang, Y., Bai, Y., Zaia, J., Costello, C. E., Hong, P., & Lin, C. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03183 · Cited by 68
Compartment Modeling for Mammalian Protein Turnover Studies by Stable Isotope Metabolic Labeling
Guan, S., Price, J. C., Ghaemmaghami, S., Prusiner, S. B., & Burlingame, A. L. (2012) · Analytical Chemistry · doi:10.1021/ac203330z · Cited by 67
Dinosaur: A Refined Open-Source Peptide MS Feature Detector
Teleman, J., Chawade, A., Sandin, M., Levander, F., & Malmström, J. A. (2016) · Journal of Proteome Research · doi:10.1021/acs.jproteome.6b00016 · Cited by 74
“Instead, Dinosaur compares the suggested isotope pattern intensity pro fi le to the shifted versions of an averagine peptide 35 of the same mass.”
BackgroundMass Spectrometric Analysis of Histone Proteoforms
Yuan, Z.-F., Arnaudo, A. M., & Garcia, B. A. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-015959 · Cited by 64
Data processing methods and quality control strategies for label-free LC–MS protein quantification
Sandin, M., Teleman, J., Malmström, J. A., & Levander, F. (2013) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2013.03.026 · Cited by 81
Díaz, P., D’Suze, G., Salazar, V., Sevcik, C., Shannon, J. D., Sherman, N. E., & Fox, J. W. (2009) · Toxicon · doi:10.1016/j.toxicon.2009.06.014 · Cited by 68
Husser, C., Brink, A., Zell, M., Müller, M. B., Koller, E., & Schadt, S. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01244 · Cited by 62
Palagi, A., Koh, J. M. S., Leblanc, M., Wilson, D. T. R., Dutertre, S., King, G. F., Nicholson, G. M., & Escoubas, P. (2013) · Journal of Proteomics · doi:10.1016/j.jprot.2013.01.002 · Cited by 61
“[37] Senko MW, Beu SC, McLafferty FW.”
A Method for Automatically Interpreting Mass Spectra of 18O-Labeled Isotopic Clusters
Mason, C. J., Therneau, T. M., Eckel-Passow, J. E., Johnson, K. L., Oberg, A. L., Olson, J. E., Nair, K. S., Muddiman, D. C., & Bergen, H. R. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m600148-mcp200 · Cited by 61
“Step 2: For each potential isotope cluster: a) Form a matrix X with theoretical isotopic abundances, generated using averagine (16) and Mercury (22), for incorporation of 0, 1, or 2 (18)O atoms.”
MethodKazazić, S., Zhang, H., Schaub, T. M., Emmett, M. R., Hendrickson, C. L., Blakney, G. T., & Marshall, A. G. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.12.016 · Cited by 65
“This averagine fitting is performed by the original 2 method [15].”
BackgroundMethodTopFD: A Proteoform Feature Detection Tool for Top–Down Proteomics
Basharat, A. R., Zang, Y., Sun, L., & Liu, X. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.2c05244 · Cited by 66
Fuerer, C., Jenni, R., Cardinaux, L., Andetsion, F., Wagnière, S., Moulin, J., & Affolter, M. (2019) · Journal of Dairy Science · doi:10.3168/jds.2019-16273 · Cited by 60
Roy, R. S., Kelleher, N. L., Milne, J. C., & Walsh, C. T. (1999) · Chemistry & Biology · doi:10.1016/s1074-5521(99)80076-3 · Cited by 60
Enhanced Dissociation of Intact Proteins with High Capacity Electron Transfer Dissociation
Riley, N. M., Mullen, C., Weisbrod, C. R., Sharma, S., Senko, M. W., Zabrouskov, V., Westphall, M. S., Syka, J. E. P., & Coon, J. J. (2016) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-015-1306-8 · Cited by 59
“1254 is the mass of averagine [55].”
Self-citationPalaniappan, K. K., Pitcher, A. A., Smart, B. P., Spiciarich, D. R., Iavarone, A. T., & Bertozzi, C. R. (2011) · ACS Chemical Biology · doi:10.1021/cb100338x · Cited by 67
Application of network smoothing to glycan LC-MS profiling
Klein, J., Carvalho, L. E., & Zaia, J. (2018) · Bioinformatics · doi:10.1093/bioinformatics/bty397 · Cited by 59
Jebanathirajah, J. A., Pittman, J. L., Thomson, B. A., Budnik, B., Kaur, P., Rapé, M., Kirschner, M. W., Costello, C. E., & O’Connor, P. B. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.08.008 · Cited by 59
“The resulting charge state information allows the generation of a model isotopic distribution [ 64 , 65] that was aligned with the observed isotopic distribution.”
MethodProteome Scale Turnover Analysis in Live Animals Using Stable Isotope Metabolic Labeling
Zhang, Y., Reckow, S., Webhofer, C., Boehme, M., Gormanns, P., Egge-Jacobsen, W. M., & Turck, C. W. (2011) · Analytical Chemistry · doi:10.1021/ac102755n · Cited by 78
Durbin, K. R., Tran, J. C., Zamdborg, L., Sweet, S. M. M., Catherman, A. D., Lee, J. E., Li, M., Kellie, J. F., & Kelleher, N. L. (2010) · PROTEOMICS · doi:10.1002/pmic.201000177 · Cited by 57
“By building on our previous platforms such as cRAWler and ProSightPC [19, 27], which all have their basis in the early study of Senko et al. [28, 29], we can now handle most of the data idiosyncrasies obtained through high-throughput Top-Down Proteomics platforms currently in operation [6, 12].”
MethodA Comprehensive, Open-source Platform for Mass Spectrometry-based Glycoproteomics Data Analysis
Liu, G., Cheng, K., Lo, C. Y., Li, J., Qu, J., & Neelamegham, S. (2017) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m117.068239 · Cited by 66
“The monoisotopic mass corresponding to each MS/MS product was determined using the “averagine” method (37), using trypsin digested fetuin glycopeptide results presented in this publication as a model.”
MethodErt, M. N. V., Hofstadler, S. A., Jiang, Y., Busch, J. D., Wagner, D. M., Drader, J. J., Ecker, D. J., Hannis, J. C., Huynh, L. Y., Schupp, J. M., et al. (2004) · BioTechniques · doi:10.2144/04374rr01 · Cited by 57
He, L., Anderson, L. C., Barnidge, D. R., Murray, D. L., Hendrickson, C. L., & Marshall, A. G. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1602-6 · Cited by 55
Frahm, J. L., Howard, B. E., Heber, S., & Muddiman, D. C. (2006) · Journal of Mass Spectrometry · doi:10.1002/jms.1024 · Cited by 56
French, W. R., Zimmerman, L. J., Schilling, B., Gibson, B. W., Miller, C. A., Townsend, R. R., Sherrod, S. D., Goodwin, C. R., MCLEAN, J. A. J., & Tabb, D. L. (2014) · Journal of Proteome Research · doi:10.1021/pr500886y · Cited by 59
He, F., Hendrickson, C. L., & Marshall, A. G. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00132-4 · Cited by 55
“In fact, the statistical variation in number of ions from scan to scan may be used (in reverse) to determine the number of trapped ions of that mass-tocharge ratio [ 34 ].”
MethodLC-MSsim – a simulation software for liquid chromatography mass spectrometry data
Schulz-Trieglaff, O. B., Pfeifer, N., Gröpl, C., Kohlbacher, O., & Reinert, K. (2008) · BMC Bioinformatics · doi:10.1186/1471-2105-9-423 · Cited by 60
“After this, we estimated the isotopic peak profile for a peptide of the same mass using the method of averagines [61].”
MethodEstablishing Drug Resistance in Microorganisms by Mass Spectrometry
Demirev, P. A., Hagan, N., Antoine, M. D., Lin, J. S., & Feldman, A. B. (2013) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-013-0609-x · Cited by 57
“*Prediction is based on a statistical amino acid “averagine” [16].”
BackgroundMethodBlake, S. L., Walker, S. H., Muddiman, D. C., Hinks, D., & Beck, K. R. (2011) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-011-0244-3 · Cited by 53
“The χ(2) value for the relative abundances in relation to the monoisotopic peak in the isotopic distribution of DY 42 was calculated to quantify spectral accuracy; shown as equation (2) [17].”
MethodAn Efficient Method to Calculate the Aggregated Isotopic Distribution and Exact Center-Masses
Claesen, J., Dittwald, P., Burzykowski, T., & Valkenborg, D. (2012) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-011-0326-2 · Cited by 52
Lindner, R. M., Lou, X., Reinstein, J., Shoeman, R. L., Hamprecht, F. A., & Winkler, A. (2014) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-014-0850-y · Cited by 52
“Since neither the peptides nor their isotope patterns are known in advance, NITPICK generates an over-complete set of candidate isotope patterns using an improved Averagine model [25] of all peaks exceeding a user-specified signal to noise ratio (SNR).”
Precursor-Ion Mass Re-Estimation Improves Peptide Identification on Hybrid Instruments
Luethy, R., Kessner, D., Katz, J. E., MacLean, B., Grothe, R., Kani, K., Faça, V. M., Pitteri, S. J., Hanash, S., Agus, D. B., et al. (2008) · Journal of Proteome Research · doi:10.1021/pr800307m · Cited by 51
Boskamp, T., Lachmund, D., Casadonte, R., Hauberg‐Lotte, L., Kobarg, J. H., Kriegsmann, J., & Maaß, P. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04473 · Cited by 51
Tucholski, T., Knott, S. J., Chen, B., Pistono, P., Lin, Z., & Ge, Y. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04082 · Cited by 49
Image analysis tools and emerging algorithms for expression proteomics
Dowsey, A. W., English, J. A., Lisacek, F., Morris, J. S., Yang, G., & Dunn, M. J. (2010) · PROTEOMICS · doi:10.1002/pmic.200900635 · Cited by 55
“The average isotope envelope of an unknown peptide with known m/z can be determined through multinomial expansion of the natural distributions of C, H, N, O and S in each amino acid [26], together with all expected amino acid configurations obtained from a proteomics database [27].”
MethodLodge, J. M., Schauer, K. L., Brademan, D. R., Riley, N. M., Shishkova, E., Westphall, M. S., & Coon, J. J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00705 · Cited by 55
Isotopic compositions and accurate masses of single isotopic peaks
Rockwood, A. L., Orman, J. R. V., & Dearden, D. V. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2003.08.011 · Cited by 49
“have proposed the use of “averagine” modeling as a way of estimating the unobservable mono-isotopic masses [2].”
BackgroundSoftware Platform for High-Throughput Glycomics
Vakhrushev, S. Y., Dadimov, D., & Peter‐Katalinić, J. (2009) · Analytical Chemistry · doi:10.1021/ac802408f · Cited by 48
Kronewitter, S. R., Leoz, M. L. A. D., Strum, J. S., An, H. J., Dimapasoc, L. M., Guerrero, A., Miyamoto, S., Lebrilla, C. B., & Leiserowitz, G. S. (2012) · PROTEOMICS · doi:10.1002/pmic.201100273 · Cited by 50
Dissociation of individual isotopic peaks: predicting isotopic distributions of product ions in MSn
Rockwood, A. L., Kushnir, M. M., & Nelson, G. J. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00062-x · Cited by 48
“For example, Figure 12 shows a calculated parent ion isotopic distributions for a hypothetical “averagine22” and “averagine44” peptides [25] of formulas C109H171N30O33S andC218H342N60O66S2 .”
BackgroundHigh‐efficiency nano‐ and micro‐HPLC – High‐resolution Orbitrap‐MS platform for top‐down proteomics
Mohr, J., Swart, R., Samonig, M., Böhm, G., & Huber, C. G. (2010) · PROTEOMICS · doi:10.1002/pmic.201000341 · Cited by 46
“It subsequently deconvolutes all signals related to a series of multiply charged ions into a spectrum of the uncharged protein and determines the monoisotopic mass by matching the measured isotope pattern to a calculated isotope pattern obtained from the elemental composition of an average hypothetical amino acid (ave…”
BackgroundA model-based method for the prediction of the isotopic distribution of peptides
Valkenborg, D., Jansen, I., & Burzykowski, T. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.01.009 · Cited by 46
“, calculate the average isotopic distribution for any mass peptide via the multinomial expansion [1], using a scaled version of Averagine [2].”
MethodNepomuceno, A. I., Mason, C. J., Muddiman, D. C., Bergen, H. R., & Zeldenrust, S. R. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.033274 · Cited by 47
Masselon, C., Paša‐Tolić, L., Tolić, N., Anderson, G., Bogdanov, B., Vilkov, A. N., Shen, Y., Zhao, R., Qian, W., Lipton, M. S. W., et al. (2004) · Analytical Chemistry · doi:10.1021/ac049043e · Cited by 46
Kelleher, N. L., Nicewonger, R., Begley, T. P., & McLafferty, F. W. (1997) · Journal of Biological Chemistry · doi:10.1074/jbc.272.51.32215 · Cited by 46
Proteoform Suite: Software for Constructing, Quantifying, and Visualizing Proteoform Families
Cesnik, A. J., Shortreed, M. R., Schaffer, L. V., Knoener, R. A., Frey, B. L., Scalf, M., Solntsev, S. K., Dai, Y., Gasch, A. P., & Smith, L. M. (2018) · Journal of Proteome Research · doi:10.1021/acs.jproteome.7b00685 · Cited by 43
Contemporary lipidomic analytics: opportunities and pitfalls
Giles, C., Takechi, R., Lam, V., Dhaliwal, S. S., & Mamo, J. C. L. (2018) · Progress in Lipid Research · doi:10.1016/j.plipres.2018.06.003 · Cited by 45
Eckel‐Passow, J. E., Oberg, A. L., Therneau, T. M., Mason, C. J., Mahoney, D. W., Johnson, K. L., Olson, J. E., & Bergen, H. R. (2006) · Bioinformatics · doi:10.1093/bioinformatics/btl464 · Cited by 44
Computational methods and challenges in hydrogen/deuterium exchange mass spectrometry
Claesen, J., & Burzykowski, T. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21519 · Cited by 46
Wehofsky, M., Hoffmann, R., Hubert, M., & Spengler, B. (2001) · European Journal of Mass Spectrometry · doi:10.1255/ejms.387 · Cited by 51
Touchard, A., Koh, J. M. S., Aili, S. R., Déjean, A., Nicholson, G. M., Orivel, J., & Escoubas, P. (2015) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.7116 · Cited by 49
Tran, B. Q., Barton, C., Feng, J., Sandjong, A., Yoon, S. H., Awasthi, S., Liang, T., Khan, M. M., Kilgour, D. P. A., Goodlett, D. R., et al. (2015) · Journal of Proteomics · doi:10.1016/j.jprot.2015.10.021 · Cited by 46
“Sophisticated numerical annotation procedure (SNAP) algorithm [19] was applied to the phased MALDI-ISD spectrum as well as ETD and ECD spectra extracting isotopic fragment ions at a quality factor threshold of 0.”
MethodDasari, S., Wilmarth, P. A., Reddy, A. P., Robertson, L. J. G., Nagalla, S. R., & David, L. L. (2009) · Journal of Proteome Research · doi:10.1021/pr801054w · Cited by 41
Rodgers, R. P., Blumer, E. N., Hendrickson, C. L., & Marshall, A. G. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00158-6 · Cited by 41
“However, a peptide of elemental composition averaged over the protein database [ 24 ] contains 27.5% as many nitrogens as carbons.”
BackgroundInfluentialXu, Y., & Lazar, I. M. (2009) · BMC Cancer · doi:10.1186/1471-2407-9-96 · Cited by 43
“12) [42].”
Higgins, K. A., Peng, H., Luebke, J. L., Chang, F. J., & Giedroc, D. P. (2015) · Biochemistry · doi:10.1021/acs.biochem.5b00056 · Cited by 38
Discussion on common data analysis strategies used in MS‐based proteomics
Matthiesen, R., Azevedo, L., Amorim, A., & Carvalho, A. S. (2011) · PROTEOMICS · doi:10.1002/pmic.201000404 · Cited by 45
“If no sequence information is available then the isotope distribution can be approximated by the ‘‘averagine’’ model [37].”
MethodAn insight into high-resolution mass-spectrometry data
Eckel‐Passow, J. E., Oberg, A. L., Therneau, T. M., & Bergen, H. R. (2009) · Biostatistics · doi:10.1093/biostatistics/kxp006 · Cited by 41
Identification of Splice Variants and Isoforms in Transcriptomics and Proteomics
Su, T., Hollas, M. A. R., Fellers, R. T., & Kelleher, N. L. (2023) · Annual Review of Biomedical Data Science · doi:10.1146/annurev-biodatasci-020722-044021 · Cited by 44
“To estimate the probability of obtaining at least as good a match as chance between the observed and theoretical fragments, Meng et al. developed the P-score (116), which has been implemented in ProsightPD (117).”
BackgroundBruce, J. E., Anderson, G., Udseth, H. R., & Smith, R. D. (1998) · Analytical Chemistry · doi:10.1021/ac9711706 · Cited by 36
Park, K., Yoon, J. Y., Lee, S., Paek, E., Park, H., Jung, H.-J., & Lee, S.-W. (2008) · Analytical Chemistry · doi:10.1021/ac800913b · Cited by 36
Computational Tools for Hydrogen–Deuterium Exchange Mass Spectrometry Data Analysis
Stofella, M., Grimaldi, A., Smit, J. H., Claesen, J., Paci, E., & Sobott, F. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00438 · Cited by 36
Wang, B., Sun, G., Anderson, D. R., Jia, M., Previs, S. F., & Anderson, V. E. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2007.03.036 · Cited by 34
“To determine f, we compared the IDs calculated using the general formula for averagine peptides [17] at 500, 1000, 1500, 2000 and 2500 Da to the correct ID determined with an average value calculated from IsoPro 3.”
MethodArtemenko, K. A., Zubarev, A. R., Samgina, T. Y., Lebedev, А. T., Savitski, M. M., & Zubarev, R. A. (2009) · Analytical Chemistry · doi:10.1021/ac802532j · Cited by 34
Two-dimensional mass spectrometry of biomolecules at the subfemtomole level
McLafferty, F. W., Kelleher, N. L., Begley, T. P., Fridriksson, E. K., Zubarev, R. A., & Horn, D. M. (1998) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(98)80085-9 · Cited by 44
Relative Retention Time Estimation Improves N-Glycopeptide Identifications by LC–MS/MS
Klein, J., & Zaia, J. (2020) · Journal of Proteome Research · doi:10.1021/acs.jproteome.0c00051 · Cited by 34
Yusuf, Y., Massiot, J., Chang, Y.-T., Wu, P., Yeh, V., Kuo, P., Shiue, J., & Yu, T. (2018) · Langmuir · doi:10.1021/acs.langmuir.8b00025 · Cited by 34
Abdrakhimov, D. A., Bubis, J. A., Gorshkov, V., Kjeldsen, F., Gorshkov, M. V., & Ivanov, M. V. (2021) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.9045 · Cited by 35
Mass calibration options for accurate electrospray ionization mass spectrometry
Romson, J., & Emmer, Å. (2021) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2021.116619 · Cited by 36
Next-Generation Serology by Mass Spectrometry: Readout of the SARS-CoV-2 Antibody Repertoire
Melani, R. D., Soye, B. J. D., Kafader, J. O., Forte, E., Hollas, M. A. R., Blagojevic, V., Negrão, F., McGee, J. P., Drown, B., Lloyd-Jones, C., et al. (2021) · Journal of Proteome Research · doi:10.1021/acs.jproteome.1c00882 · Cited by 32
The isotope distribution: A rose with thorns
Claesen, J., Rockwood, A. L., Gorshkov, M. V., & Valkenborg, D. (2023) · Mass Spectrometry Reviews · doi:10.1002/mas.21820 · Cited by 36
Accurate base composition of double-strand DNA by mass spectrometry
Aaserud, D. J., Kelleher, N. L., Little, D. P., & McLafferty, F. W. (1996) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(96)00194-8 · Cited by 32
Forstenlehner, I. C., Holzmann, J., Scheffler, K., Wieder, W., Toll, H., & Huber, C. G. (2013) · Analytical Chemistry · doi:10.1021/ac403390y · Cited by 32
SPOQ $\ell _p$-Over-$\ell _q$ Regularization for Sparse Signal Recovery Applied to Mass Spectrometry
Cherni, A., Chouzenoux, É., Duval, L. C., & Pesquet, J.-C. (2020) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2020.3025731 · Cited by 42
“Thus, its isotopic pattern at a given mass and charge state can be easily synthesized, by making use of the so-called “averagine”4 model [75], [76].”
MethodBresson, J. A., Anderson, G., Bruce, J. E., & Smith, R. D. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00047-6 · Cited by 31
Jehmlich, N., Schmidt, F., Taubert, M., Seifert, J., von Bergen�, M., Richnow, H. H., & Vogt, C. (2009) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4084 · Cited by 33
High-resolution ion isolation with the ion cyclotron resonance capacitively coupled open cell
O’Connor, P. B., & McLafferty, F. W. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00232-3 · Cited by 31
Dodds, E. D., An, H. J., Hagerman, P. J., & Lebrilla, C. B. (2006) · Journal of Proteome Research · doi:10.1021/pr050486o · Cited by 31
“34 Each of these peptides was then shifted in mass as appropriate for each modification of interest.”
Chen, J., Shiyanov, P. A., Zhang, L., Schlager, J. J., & Green‐Church, K. B. (2010) · Analytical Chemistry · doi:10.1021/ac1006766 · Cited by 31
Pena, A. B., Gibbons, B. C., Slysz, G., Crowell, K. L., Monroe, M. E., Ibrahim, Y., Smith, R. D., Payne, S., & Baker, E. S. (2017) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2017.11.003 · Cited by 32
“For the peptide analyses, the software implementation reported here used the so-called averagine method to create an approximate peptide molecular formula from the given monoisotopic mass [21].”
Hummel, M., Wigger, T., & Brockmeyer, J. (2015) · Journal of Proteome Research · doi:10.1021/pr5012262 · Cited by 33
Taubert, M., Baumann, S., von Bergen�, M., & Seifert, J. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5289-4 · Cited by 28
“demonstrated in this study allows an estimation based on the averaging model of peptides [ 24 ], suggesting that a determination of around 0.5% 15 N RIA should be possible”
MethodInfluentialAutopiquer - a Robust and Reliable Peak Detection Algorithm for Mass Spectrometry
Kilgour, D. P. A., Hughes, S., Kilgour, S. L., Mackay, C. L., Palmblad, M., Tran, B. Q., Goo, Y. A., Ernst, R. K., Clarke, D. J., & Goodlett, D. R. (2016) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1549-z · Cited by 30
“In the case of the isotopic wavelet, the isotopic distribution is estimated for peptides using the averagine model [11].”
MethodSchaffer, L. V., Shortreed, M. R., Cesnik, A. J., Frey, B. L., Solntsev, S. K., Scalf, M., & Smith, L. M. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04221 · Cited by 28
Data reduction of isotope-resolved LC-MS spectra
Du, P., Sudha, R., Prystowsky, M. B., & Angeletti, R. H. (2007) · Bioinformatics · doi:10.1093/bioinformatics/btm083 · Cited by 27
Wang, Z., Xie, H., Ren, J., Chen, Y., Li, X., Chen, X., & Chan, T. D. (2020) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2020.113177 · Cited by 26
Slawski, M., Hussong, R., Tholey, A., Jakoby, T., Gregorius, B., Hildebrandt, A., & Hein, M. (2012) · BMC Bioinformatics · doi:10.1186/1471-2105-13-291 · Cited by 34
“These heights are computed according to the averagine model [16].”
MethodRhoads, T. W., Williams, J. R., Lopez, N. I., Morré, J. T., Bradford, C. S., & Beckman, J. S. (2012) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-012-0500-1 · Cited by 28
“However, the natural abundance of (13)C and other stable isotopes in proteins obscures such low mass modifications because the same number of protein ions are distributed over dozens of isotopic mass peaks [2, 3].”
Ford, M. J., Cantone, J. L., Polson, C. T., Toyn, J. H., Meredith, J. E., & Drexler, D. M. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.11.019 · Cited by 26
PeakSelect : preprocessing tandem mass spectra for better peptide identification
Zhang, J., He, S., Ling, C. X., Cao, X.-J., Zeng, R., & Gao, W. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3488 · Cited by 26
Isotope depletion of large biomolecules: Implications for molecular mass measurements
Zubarev, R. A., & Demirev, P. A. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00232-8 · Cited by 26
Nicolardi, S., Palmblad, M., Dalebout, H., Bladergroen, M. R., Tollenaar, R. A. �. �., Deelder, A. M., & van der Burgt, Y. E. M. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2010.05.004 · Cited by 25
“to construct peptides from a hypothetical average amino acid [41].”
BackgroundMethodIsolation of recombinant tetrameric N-acetylated α-synuclein
Fernández, R. D., & Lucas, H. R. (2018) · Protein Expression and Purification · doi:10.1016/j.pep.2018.07.008 · Cited by 27
Distinguishing Small Molecular Mass Differences of Proteins by Mass Spectrometry
Green, M. K., Vestling, M. M., Johnston, M. V., & Larsen, B. S. (1998) · Analytical Biochemistry · doi:10.1006/abio.1998.2692 · Cited by 25
Heep, J., Škaljac, M., Grotmann, J., Kessel, T., Seip, M., Schmidtberg, H., & Vilcinskas, A. (2019) · Toxins · doi:10.3390/toxins11100562 · Cited by 30
Functional asymmetry and chemical reactivity of CsoR family persulfide sensors
Fakhoury, J. N., Zhang, Y., Edmonds, K. A., Bringas, M., Luebke, J. L., González-Gutiérrez, G., Capdevila, D. A., & Giedroc, D. P. (2021) · Nucleic Acids Research · doi:10.1093/nar/gkab1040 · Cited by 26
“The theoretical distribution and peak areas were determined using the averagine algorithm (38) and quantified by summing the total peak areas of the full isotopic distribution.”
MethodValence Parity Renders z•-Type Ions Chemically Distinct
Hubler, S. L., Jue, A. L., Keith, J. M., McAlister, G. C., Crăciun, G., & Coon, J. J. (2008) · Journal of the American Chemical Society · doi:10.1021/ja7099985 · Cited by 25
A MS data search method for improved 15N‐labeled protein identification
Zhang, Y., Webhofer, C., Reckow, S., Filiou, M., Maccarrone, G., & Turck, C. (2009) · Proteomics · doi:10.1002/pmic.200900108 · Cited by 22
“0417, which represents the statistical occurrence of the 20 common amino acids in the protein identification resource protein database [24].”
BackgroundImproving Spectral Validation Rates in Hydrogen–Deuterium Exchange Data Analysis
Raval, S., Sarpe, V., Hepburn, M., Crowder, D. A., Zhang, T., Viner, R., & Schriemer, D. C. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c05045 · Cited by 25
Metadata
- Authors
- Senko, M. W., Beu, S. C., & McLaffertycor, F. W.
- Affiliations
- Cornell University (US)
- ORCID
- Senko, Michael W.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1995-04-01
- Volume
- 6
- Issue
- 4
- Pages
- 229-233
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2086502504
- Semantic Scholar
- 94b2dabffe606cc05171d713f5c8c92da73345ca
- Cited by
- 451
- References
- 24
- Citations by year
- 2026: 12 · 2025: 14 · 2024: 19 · 2023: 12 · 2022: 11 · 2021: 19 · 2020: 28 · 2019: 18 · 2018: 16 · 2017: 23 · 2016: 20 · 2015: 17 · 2014: 21 · 2013: 22 · 2012: 15
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the American Society for Mass Spectrometry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- isotopic distribution, large biomolecules, electrospray ionization, Fourier transform mass spectrometry, statistical tests, signal-to-noise ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.