Determination of monoisotopic masses and ion populations for large biomolecules from resolved isotopic distributions
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
The coupling of electrospray ionization with Fourier-transform mass spectrometry allows the analysis of large biomolecules with mass-measuring errors of less than 1 ppm. The large number of atoms incorporated in these molecules results in a low probability for the all-monoisotopic species. This produces the potential to misassign the number of heavy isotopes in a specific peak and make a mass error of ±1 Da, although the certainty of the measurement beyond the decimal place is greater than 0.1 Da. Statistical tests are used to compare the measured isotopic distribution with the distribution for a model molecule of the same average molecular mass, which allows the assignment of the monoisotopic mass, even in cases where the monoisotopic peak is absent from the spectrum. The statistical test produces error levels that are inversely proportional to the number of molecules in a distribution, which allows an estimation of the number of ions in the trapped ion cell. It has been determined, via this method that 128 charges are required to produce a signal-to-noise ratio of 3:1, which correlates well with previous experimental methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“THRASH uses a theoretical isotopomer envelope based on the average elemental composition of amino acids (averagine) [125] to compare to the experimental envelopes. A statistical score is then assigned based on the overlap of the experimental and theoretical fit.”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [125]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Matrix-assisted ultraviolet laser desorption of non-volatile compounds
Karas, M., Bachmann, D., Bahr, U., & Hillenkamp, F. (1987) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(87)87041-6 · Cited by 1,953
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
New developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
Smith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
High-resolution electrospray mass spectra of large molecules
Henry, K. D., Quinn, J. P., & McLafferty, F. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00014a043 · Cited by 309
Loo, J. A., Udseth, H. R., & Smith, R. D. (1989) · Analytical Biochemistry · doi:10.1016/0003-2697(89)90153-x · Cited by 264
A general approach to calculating isotopic distributions for mass spectrometry
Yergey, J. A. (1983) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(83)85053-0 · Cited by 222
Fourier-transform mass spectrometry of large molecules by electrospray ionization.
Henry, K. D., Williams, E. R., Wang, B. H., McLafferty, F. W., Shabanowitz, J., & Hunt, D. F. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.23.9075 · Cited by 215
Loo, J. A., Edmonds, C. G., & Smith, R. D. (1991) · Analytical Chemistry · doi:10.1021/ac00021a018 · Cited by 189
Research works printed but not linked: 2
- 1. Teer, D.; Dole, M. J. Polym. Sci. 1975, 13, 985.
- 21. Labowski, M.; Whitehouse, C. M.; Fenn, J. B. Rapid Commun. Mass Spectrom. 1993, 7, 71.
Cited by
Items 401–455 of 455
Lanzillotti, M. B., Dunham, S. D., Juetten, K. J., & Brodbelt, J. S. (2025) · Journal of Proteome Research · doi:10.1021/acs.jproteome.4c00607 · Cited by 1
Semi-Quantitative MALDI Measurements of Blood-Based Samples for Molecular Diagnostics
Koc, M. A., Asmellash, S. G., Norman, P., Rightmyer, S., Roder, J., Georgantas, R. W., & Röder, H. (2022) · Molecules · doi:10.3390/molecules27030997 · Cited by 1
“As proteins get larger, we expect to see a wider isotopic distribution [33].”
BackgroundBob, K., Teschner, D., Kemmer, T., Gomez‐Zepeda, D., Tenzer, S., Schmidt, B., & Hildebrandt, A. (2022) · BMC Bioinformatics · doi:10.1186/s12859-022-04833-5 · Cited by 1
“The averagine model as proposed by [11] was used to create all reference patterns.”
BackgroundMethodInfluentialAgten, A., Claesen, J., Burzykowski, T., & Valkenborg, D. (2023) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.9480 · Cited by 1
Automated Assignment of 15N And 13C Enrichment Levels in Doubly-Labeled Proteins
Roberts, E. T., Davis, A. R., Risher, J. T., Barb, A. W., & Amster, I. J. (2024) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.4c00218 · Cited by 1
High‐Resolution Mass Spectrometry and Its Applications
Jennings, K. R. (2000) · Wiley eBooks · doi:10.1002/9780470027318.a6009 · Cited by 1
In-depth analysis of zero-length crosslinking for structural mass spectrometry
Sriswasdi, S. (2013) · ScholarlyCommons (University of Pennsylvania) · Cited by 3
Topics in learning sparse and low-rank models of non-negative data
Slawski, M. (2014) · Publications of the UdS (Saarland University) · doi:10.22028/d291-26602 · Cited by 1
“The latter represents an isotopic pattern which is modeled as a positive combination of Diracs centered at m/z-positions {μk+ l zk }, where the weights {αl(μ ∗ k; zk)}l∈Z follow a well-established model for isotopic abundances [142] given the position μk of the leading peak (i.”
BackgroundSpeed Improvement of an FTICR Mass Spectra Analysis Program by Simple Modifications
Jeon, S.-H., Chang, H.-S., Hur, M., Kwon, K., Kim, H. S., Yoo, J., Kim, S., Park, S., & Oh, H. B. (2009) · Bulletin of the Korean Chemical Society · doi:10.5012/bkcs.2009.30.9.2061 · Cited by 1
Investigation and interpretation of large mass spectrometry imaging datasets
Race, A. (2016) · University of Birmingham Institutional Research Archive (University of Birmingham) · Cited by 2
Belov (2017) · Digital Repository Service (Northeastern University) · doi:10.17760/d20259955 · Cited by 1
Etmann, C., Schmidt, M., Behrmann, J., Boskamp, T., Hauberg‐Lotte, L., Peter, A., Casadonte, R., Kriegsmann, J., & Maaß, P. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1912.05459 · Cited by 4
“The convolutional and locally-connected layers are only applied as many times as necessary for the receptive fields to cover the isotopic patterns of peptides, based on the ’averagine’ model [Senko et al. , 1995].”
Ross, R. L., Cowley, R. E., Murphy, K., Gamez, R. C., Gazis, P., Sutton, J. N., & Du, M. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.06.07.544034 · Cited by 1
Elemental allocation to molecular drivers of biogeochemistry in the Southern OceanPreprint
Jabre, L. J., Rowland, E. E., Eich, C., van Manen, M., Brussaard, C. P. D., Middag, R., & Bertrand, E. M. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.10.03.680396 · Cited by 2
“II) We identified peptide-like features based on feature resemblance to the isotopic distribution of a theoretical peptide model, “averagine” 108 , and quantified their total abundance for each sample using Hardklör and Krönik 109 .”
Li, K., Liu, K., Fulcher, J. M., Kaulich, P. T., Tang, H., & Liu, X. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.02.20.707032 · Cited by 1
“(1) For each deconvoluted mass, the theoretical isotopic envelope was calculated using the Averagine model [25].”
Image Analysis Tools in Proteomics
Dowsey, A. W., English, J. A., Lisacek, F., Morris, J. S., Yang, G., & Dunn, M. J. (2011) · Wiley eBooks · doi:10.1002/9780470015902.a0006216.pub2
Neto, J. G. A. B. (2002) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.46.2002.tde-07072003-100805 · Cited by 3
Inferring Proteolytic Processes from Mass Spectrometry Time Series Data
Aiche, S. (2013) · Universitätsbibliothek der FU Berlin Hochschulschriftenstelle u. Dokumentenserver · doi:10.17169/refubium-4956
“2Swiss-Prot:P05305[53-73] 3Swiss-Prot:P01019[34-43] 4Swiss-Prot:P61278[89-116]”
Blakney, G. T. (2003) · Texas ScholarWorks (Texas Digital Library)
Law of Localised Fine Structure with application in mass spectrometryPreprint
Łącki, M. K., & Gambin, A. (2014) · arXiv (Cornell University) · doi:10.48550/arxiv.1410.7378
“[20] established the concept of m-avergine, i.”
Li, J. (2006) · UA Campus Repository (The University of Arizona)
Accurate samples for testing mass spectrometry based peptide quantification algorithms
Carrillo, B., LaBoissière, S., Nadon, R., & Kearney, R. E. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626766
Statistical methods for biomarker discovery in proteomics
Tan, C. S. (2008) · Figshare
Grayson, M. A. (2015) · Elsevier eBooks · doi:10.1016/b978-0-08-100379-4.00138-6
Characterization of ribonucleoproteins by cross-linking and mass spectrometry.
Pourshahian, S. (2008) · OhioLink ETD Center (Ohio Library and Information Network)
Synthetic Biology Approaches for Combinatorial Biosynthesis of Polyketide Natural Products.
Koryakina, I. (2014) · NCSU Libraries Repository (North Carolina State University Libraries)
Algorithms for MS1-Based Quantitation
Liao, H., Phillips, A. M., Jankevics, A., & Dowsey, A. W. (2016) · Royal Society of Chemistry eBooks · doi:10.1039/9781782626732-00133
Quantitative Approaches for Protein Differential Expression Analysis
Xu, Y. (2009) · VTechWorks (Virginia Tech)
Quijada, J. V. (2017) · Digital Repository Service (Northeastern University) · doi:10.17760/d20248916
Time of flight mass spectrometer (TOF-MS)
Takeda, U., Kasamatsu, T., Takinami, Y., & Satoh, T. (2017) · Japanese Journal of Pesticide Science · doi:10.1584/jpestics.w17-53
Quantitative glycomics using simulation optimization
Han, J. (2012)
DIAFree enables untargeted open-search identification for Data-Independent Acquisition dataPreprint
Xu, X. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.08.30.274209
“The quality of the isotope cluster is assessed by comparing this reconstructed isotope cluster to the theoretical cluster calculated by the Averagine(25) model using a simplified EMASS(26) algorithm implementation.”
MethodQuantitative phosphoproteomics for studying B-cell receptor signaling in Burkitt’s lymphoma
Corso, J. (2017) · eDiss (Georg-August-Universität Göttingen) · doi:10.53846/goediss-6137
Joshi, R., & Hawkridge, A. M. (2024) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.4c00246
Scharrenbroch, L., Scheid, N., Holdermann, T., Schäfer, T., Ahrens, B., Worbs, S., Dorner, B. G., & Lermyte, F. (2025) · The Analyst · doi:10.1039/d5an00572h
Precise Monoisotopic Peak Assignment of Intact Glycopeptides Using Partial Average Mass Matching
Ye, Q., Shen, J., Zhu, B., Chen, Z., Yuan, X., & Sun, S. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.5c01493
Meenakshi, M., Migas, L. G., Djambazova, K. V., Dufresne, M., Spraggins, J. M., & de Plas, R. V. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2025.11.30.691393 · Cited by 1
“The third dataset is a lipid-focused measurement of human kidney tissue from the HuBMAP initiative 12 , using a MALDI timsTOF fleX (Bruker Daltonik, Bremen, Germany).”
Xiong, Y., Mueller, R., Feng, S., Guo, X., & Pan, C. (2024) · Figshare · doi:10.6084/m9.figshare.26758784
Xiong, Y., Mueller, R., Feng, S., Guo, X., & Pan, C. (2024) · Figshare · doi:10.6084/m9.figshare.26525195
Xiong, Y., Mueller, R., Feng, S., Guo, X., & Pan, C. (2024) · Figshare · doi:10.6084/m9.figshare.26525159
Xiong, Y., Mueller, R., Feng, S., Guo, X., & Pan, C. (2024) · Figshare · doi:10.6084/m9.figshare.26758778
Xiong, Y., Mueller, R., Feng, S., Guo, X., & Pan, C. (2024) · Figshare · doi:10.6084/m9.figshare.26758781
Xiong, Y., Mueller, R., Feng, S., Guo, X., & Pan, C. (2024) · Figshare · doi:10.6084/m9.figshare.26758799
Xiong, Y., Mueller, R., Feng, S., Guo, X., & Pan, C. (2024) · Figshare · doi:10.6084/m9.figshare.26758793
Xiong, Y., Mueller, R., Feng, S., Guo, X., & Pan, C. (2024) · Figshare · doi:10.6084/m9.figshare.26758796
Xiong, Y., Mueller, R., Feng, S., Guo, X., & Pan, C. (2024) · Figshare · doi:10.6084/m9.figshare.26758787
Xiong, Y., Mueller, R., Feng, S., Guo, X., & Pan, C. (2024) · Figshare · doi:10.6084/m9.figshare.26758790
Anderson, L. C., Kaiser, N. K., Kamadana, K. S., & Mallory, X. (2026) · Analytical Chemistry · doi:10.1021/acs.analchem.5c06165
Ross, R. L., Sun, H., Bursch, M., de Souza, B., Gamez, R., Murphy, K., Du, M., & Suzuki, T. (2026) · Analytical Chemistry · doi:10.1021/acs.analchem.6c01855
The Rise of Top‐Down Mass Spectrometry for the Characterization of Oligonucleotide Therapeutics
Blevins, M. S., Crittenden, C. M., & Chen, B. (2026) · Mass Spectrometry Reviews · doi:10.1002/mas.70037
“To address this intrinsic challenge, the Averagine model (Senko et al. 1995) and the THRASH (Horn et al. 2000) algorithm were developed (originally, for larger protein ions), which were foundational to many existing vendor solutions, including Xtract (Thermo), SNAP (Bruker), and MaxEnt (Agilent,…”
Veth, T. S., Sutherland, E., Hinkle, J. D., Bergen, D., Melani, R. D., McAlister, G. C., Mullen, C., & Riley, N. M. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.08.27.747529 · Cited by 1
“61 The resulting atomic composition of the glycan is rounded to the nearest integer.”
Evaluating a Lightweight Neural Network for Aggregate Isotope Distribution Prediction
Pavek, J. G., Grimes, J., Frey, B. L., Welham, N. V., Smith, L. M., & Marty, M. T. (2026) · Journal of Proteome Research · doi:10.1021/acs.jproteome.6c00685
How conformational dynamics shape hydrogen–deuterium exchange isotopic envelopes
Grimaldi, A., & Paci, E. (2026) · The Journal of Chemical Physics · doi:10.1063/5.0347532
Kühle, L. C., Harsh, M., Hermon, S. J., Magalang, J. A. R., Köster, J., & Becker, S. M. (2026) · Analytical Chemistry · doi:10.1021/acs.analchem.6c02546
RNabel─A Standalone Software Tool for Annotating Tandem Mass Spectra of Modified Ribonucleic Acids
Song, G., Du, Y.-J. N., Sun, R., & Dong, M. (2026) · Analytical Chemistry · doi:10.1021/acs.analchem.6c02176
Metadata
- Authors
- Senko, M. W., Beu, S. C., & McLaffertycor, F. W.
- Affiliations
- Cornell University (US)
- ORCID
- Senko, Michael W.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1995-04-01
- Volume
- 6
- Issue
- 4
- Pages
- 229-233
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2086502504
- Semantic Scholar
- 94b2dabffe606cc05171d713f5c8c92da73345ca
- Cited by
- 451
- References
- 24
- Citations by year
- 2026: 12 · 2025: 14 · 2024: 19 · 2023: 12 · 2022: 11 · 2021: 19 · 2020: 28 · 2019: 18 · 2018: 16 · 2017: 23 · 2016: 20 · 2015: 17 · 2014: 21 · 2013: 22 · 2012: 15
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the American Society for Mass Spectrometry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- isotopic distribution, large biomolecules, electrospray ionization, Fourier transform mass spectrometry, statistical tests, signal-to-noise ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.