Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 160

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

A novel 3D paper-based microfluidic electrochemical glucose biosensor based on rGO-TEPA/PB sensitive film

Cao, Liangli, Han, Guo-Cheng, Xiao, Haolin, Chen, Zhencheng, Fang, Cheng·2020·Analytica Chimica Acta

Abstract

A novel 3D paper-based microfluidic screen-printed electrode (SPE) composed of two layers was constructed by photolithography and screen-printing technology. Aldehyde functionalized hydrophilic zone of the counter and reference electrodes layer was prepared for glucose oxidase immobilization. Highly conductive prussian blue deposited reduced graphene oxide-tetraethylene pentamine (rGO-TEPA/PB) modified paper working electrode layer can be used as an electrochemical sensitive membrane for quantitative detection of hydrogen peroxide (H2O2), which was the enzyme-catalyzed reaction product. Therefore, this 3D paper-based microfluidic electrochemical biosensor can be used for quantitative detection of glucose. Under optimum conditions, the proposed biosensor can be used for quantitative determination of glucose over a wide linear range of 0.1 mM-25 mM with detection limit of 25 μM. Finally, the 3D paper-based microfluidic electrochemical biosensor was applied to determine glucose in human sweat and blood, and the obtained results were in good consistency with values measured by Roche's blood glucose meter. In addition, the proposed 3D paper-based electrochemical device showed good repeatability, stability, and anti-interference, which would be of great potential to monitor glucose in complex biological fluids.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.aca.2019.10.049

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 160

Metadata

Authors
Cao, L., Han, G.-C., Xiao, H., Chen, Z., & Fang, C.
Venue
Analytica Chimica Acta
Publisher
Elsevier BV
Published
2020-02
Volume
1096
Pages
34-43
ISSN
0003-2670 (ISSN-L)
OpenAlex
W2981931690
Cited by
160
References
8
FWCI
6.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A novel 3D paper-based microfluidic electrochemical glucose biosensor based on rGO-TEPA/PB sensitive film. https://app.cochat.ai/papers/10.1016/j.aca.2019.10.049
The paper
Cao, L., Han, G.-C., Xiao, H., Chen, Z., & Fang, C. (2020). A novel 3D paper-based microfluidic electrochemical glucose biosensor based on rGO-TEPA/PB sensitive film. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2019.10.049

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.