The DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.
A review on the wettability of dental implant surfaces I: Theoretical and experimental aspects
Open accessAbstract
The surface wettability of biomaterials determines the biological cascade of events at the biomaterial/host interface. Wettability is modulated by surface characteristics, such as surface chemistry and surface topography. However, the design of current implant surfaces focuses mainly on specific micro- and nanotopographical features and is still far from predicting the concomitant wetting behavior. There is an increasing interest in understanding the wetting mechanisms of implant surfaces and the role of wettability on the biological response at the implant/bone or implant/soft tissue interface. Fundamental knowledge related to the influence of surface roughness (i.e., a quantification of surface topography) on titanium and titanium alloy surface wettability, and the different associated wetting regimes, can improve our understanding of the role of wettability of rough implant surfaces on the biological outcome. Such an approach has been applied to biomaterial surfaces only in a limited way. Focusing on titanium dental and orthopaedic implants, the present study reviews the current knowledge on the wettability of biomaterial surfaces, encompassing basic and applied aspects that include measurement techniques, thermodynamic aspects of wetting, and models predicting topographical and roughness effects on the wetting behavior.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wettability of porous surfaces
Cassie, A. B. D., & Baxter, S. (1944) · Transactions of the Faraday Society · doi:10.1039/tf9444000546 · Cited by 13,807 · cited 16×
“Fundamental theories of roughness-induced wetting were initially described about 70 years ago [92,93] and are still under intense research due to their widespread technical and biomedical importance.”
BackgroundMethodInfluentialRESISTANCE OF SOLID SURFACES TO WETTING BY WATER
Wenzel, R. N. (1936) · Industrial & Engineering Chemistry · doi:10.1021/ie50320a024 · Cited by 13,316 · cited 1×
“Fundamental theories of roughness-induced wetting were initially described about 70 years ago [92,93] and are still under intense research due to their widespread technical and biomedical importance.”
BackgroundEstimation of the surface free energy of polymers
Owens, D. K., & Wendt, R. C. (1969) · Journal of Applied Polymer Science · doi:10.1002/app.1969.070130815 · Cited by 9,476
Purity of the sacred lotus, or escape from contamination in biological surfaces
Barthlott, W., & Neinhuis, C. (1997) · Planta · doi:10.1007/s004250050096 · Cited by 6,860
III. An essay on the cohesion of fluids
Young, T. (1805) · Philosophical Transactions of the Royal Society of London · doi:10.1098/rstl.1805.0005 · Cited by 6,643
A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
Adell, R., Lekholm, U., Rockler, B., & Brånemark, P.-I. (1981) · International Journal of Oral Surgery · doi:10.1016/s0300-9785(81)80077-4 · Cited by 4,816
Lafuma, A., & Quéré, D. (2003) · Nature Materials · doi:10.1038/nmat924 · Cited by 3,315
Quéré, D. (2008) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.38.060407.132434 · Cited by 2,691
Albrektsson, T., Brånemark, P.-I., Hansson, H.-A., & Lindström, J. (1981) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678108991776 · Cited by 2,690
Interfacial Lifshitz-van der Waals and polar interactions in macroscopic systems
Van Oss, C. J., Chaudhury, M. K., & Good, R. J. (1988) · Chemical Reviews · doi:10.1021/cr00088a006 · Cited by 2,546
Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period.
Brånemark, P. I., Hansson, B. O., Adell, R., Breine, U., Lindström, J., Hallén, O., & ÖHMAN, A. E. (1977) · PubMed · Cited by 2,385
Petal Effect: A Superhydrophobic State with High Adhesive Force
Feng, L., Zhang, Y., Xi, J., Zhu, Y., Wang, N., Xia, F., & Jiang, L. (2008) · Langmuir · doi:10.1021/la703821h · Cited by 1,982
Intra-Osseous Anchorage of Dental Prostheses:I. Experimental Studies
Brånemark, P.-I., Breine, U., Adell, R., Hansson, B. O., Lindström, J., & Ohlsson, Å. (1969) · Scandinavian Journal of Plastic and Reconstructive Surgery · doi:10.3109/02844316909036699 · Cited by 1,811
Contact Angle, Wettability, and Adhesion
(1964) · Advances in Chemistry · doi:10.1021/ba-1964-0043 · Cited by 1,786
Structure and reactivity of water at biomaterial surfaces
Vogler, E. A. (1998) · Advances in Colloid and Interface Science · doi:10.1016/s0001-8686(97)00040-7 · Cited by 1,640
Dispersion-Polar Surface Tension Properties of Organic Solids
Kaelble, D. H. (1970) · The Journal of Adhesion · doi:10.1080/0021846708544582 · Cited by 1,499
Effects of titanium surface topography on bone integration: a systematic review
Wennerberg, A., & Albrektsson, T. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01775.x · Cited by 1,462
Surface and Interfacial Aspects of Biomedical Polymers
(1985) · Springer eBooks · doi:10.1007/978-1-4684-8610-0 · Cited by 1,284
Contact angle, wetting, and adhesion: a critical review
Good, R. J. (1992) · Journal of Adhesion Science and Technology · doi:10.1163/156856192x00629 · Cited by 1,230
Enhanced Bone Apposition to a Chemically Modified SLA Titanium Surface
Buser, D., Broggini, N., Wieland, M., Schenk, R. K., Denzer, A. J., Cochran, D. L., Hoffmann, B., Lussi, A., & Steinemann, S. G. (2004) · Journal of Dental Research · doi:10.1177/154405910408300704 · Cited by 1,202
Yan, Y. Y., Gao, N., & Barthlott, W. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2011.08.005 · Cited by 1,000
Herminghaus, S. (2000) · Europhysics Letters (EPL) · doi:10.1209/epl/i2000-00418-8 · Cited by 848
Contact Angle Hysteresis. III. Study of an Idealized Heterogeneous Surface
Johnson, R. E., & Dettre, R. H. (1964) · The Journal of Physical Chemistry · doi:10.1021/j100789a012 · Cited by 688
Rupp, F., Scheideler, L., Olshanska, N., de Wild, M., Wieland, M., & Geis‐Gerstorfer, J. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30518 · Cited by 651
Self-citationBuser, D., Janner, S. F. M., Wittneben, J., Brägger, U., Ramseier, C. A., & Salvi, G. E. (2012) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2012.00456.x · Cited by 642
Protein adsorption in three dimensions
Vogler, E. A. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.10.059 · Cited by 585
Hydrophobicity of biosurfaces — Origin, quantitative determination and interaction energies
van Oss, C. J. (1995) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/0927-7765(95)01217-7 · Cited by 574
The Impact of Contact Angle on the Biocompatibility of Biomaterials
Menzies, K. L., & Jones, L. (2010) · Optometry and Vision Science · doi:10.1097/opx.0b013e3181da863e · Cited by 559
Zhao, G., Raines, A. L., Wieland, M., Schwartz, Z., & Boyan, B. D. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.02.024 · Cited by 473
Self-citationSuggested guidelines for the topographic evaluation of implant surfaces.
Wennerberg, A., & Albrektsson, T. O. (2000) · PubMed · Cited by 462
Marshall, S. J., Bayne, S. C., Baier, R., Tomsia, A. P., & Marshall, G. W. (2010) · Dental Materials · doi:10.1016/j.dental.2009.11.157 · Cited by 430
Apparent contact angles on rough surfaces: the Wenzel equation revisited
Wolansky, G., & Marmur, A. (1999) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/s0927-7757(99)00098-9 · Cited by 400
Self-citationUnderlying mechanisms at the bone–biomaterial interface.
Schwartz, Z., & Boyan, B. D. (1994) · Journal of Cellular Biochemistry · doi:10.1002/jcb.240560310 · Cited by 397
Self-citationSurface properties determine bioadhesive outcomes: Methods and results
Baier, R., Meyer, A. E., Natiella, J. R., et al. (1984) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820180404 · Cited by 379
Marmur, A. (2008) · Langmuir · doi:10.1021/la800304r · Cited by 375
Self-citationContact angle measurement on rough surfaces
Meiron, T. S., Marmur, A., & Saguy, I. S. (2004) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2004.02.036 · Cited by 362
Self-citationThe use of environmental scanning electron microscopy for imaging wet and insulating materials
Donald, A. M. (2003) · Nature Materials · doi:10.1038/nmat898 · Cited by 357
Roughness induced dynamic changes of wettability of acid etched titanium implant modifications
Rupp, F., Scheideler, L., Rehbein, D., Axmann, D., & Geis-Gerstorfer, J. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.015 · Cited by 355
Self-citationThe Role of Implant Surface Characteristics in the Healing of Bone
Kieswetter, K., Schwartz, Z., Dean, D. D., & Boyan, B. D. (1996) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/10454411960070040301 · Cited by 338
Self-citationSharma, P. K., & Hanumantha Rao, K. (2002) · Advances in Colloid and Interface Science · doi:10.1016/s0001-8686(02)00004-0 · Cited by 335
Gittens, R. A., Olivares-Navarrete, R., Cheng, A., Anderson, D. M., McLachlan, T., Stephan, I., Geis-Gerstorfer, J., Sandhage, K. H., Fedorov, A. G., Rupp, F., et al. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.12.002 · Cited by 301
Self-citationThe surface energy of various biomaterials coated with adhesion molecules used in cell culture
Harnett, E. M., Alderman, J., & Wood, T. (2007) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2006.11.021 · Cited by 295
Nonlinear Dependence of the Contact Angle of Nanodroplets on Contact Line Curvature
Checco, A., Guenoun, P., & Daillant, J. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.186101 · Cited by 267
Schwarz, F., Wieland, M., Schwartz, Z., Zhao, G., Rupp, F., Geis‐Gerstorfer, J., Schedle, A., Broggini, N., Bornstein, M. M., Buser, D., et al. (2008) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31233 · Cited by 259
Self-citationWetting transitions on rough surfaces
Ishino, C., Okumura, K., & Quéré, D. (2004) · Europhysics Letters (EPL) · doi:10.1209/epl/i2004-10206-6 · Cited by 259
A systematic comparison of contact angle methods
Lander, L. M., Siewierski, L. M., Brittain, W. J., & Vogler, E. A. (1993) · Langmuir · doi:10.1021/la00032a055 · Cited by 244
Atmospheric plasma enhances wettability and cell spreading on dental implant metals
Duske, K., Koban, I., Kindel, E., Schröder, K., Nebe, B., Holtfreter, B., Jablonowski, L., Weltmann, K. D., & Kocher, T. (2012) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.2012.01853.x · Cited by 244
Solid-Surface Characterization by Wetting
Marmur, A. (2009) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.38.060407.132425 · Cited by 244
Self-citationKasemo, B., & Lausmaa, J. (1988) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820221307 · Cited by 237
Partial wetting of chemically patterned surfaces: The effect of drop size
Brandon, S., Haimovich, N., Yeger, E., & Marmur, A. (2003) · Journal of Colloid and Interface Science · doi:10.1016/s0021-9797(03)00285-6 · Cited by 195
Self-citationHydro- hygro- oleo- omni-phobic? Terminology of wettability classification
Marmur, A. (2012) · Soft Matter · doi:10.1039/c2sm25443c · Cited by 190
Self-citationChappuis, V., Buser, R., Brägger, U., Bornstein, M. M., Salvi, G. E., & Buser, D. (2013) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12056 · Cited by 182
Surface energy characterization of unalloyed titanium implants
Kilpadi, D. V., & Lemons, J. E. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820281206 · Cited by 177
Mechanisms of superhydrophobicity on hydrophilic substrates
Liu, J.-L., Feng, X.-Q., Wang, G., & Yu, S.-W. (2007) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/19/35/356002 · Cited by 161
Water condensation on a super-hydrophobic spike surface
Narhe, R. D., & Beysens, D. (2006) · Europhysics Letters (EPL) · doi:10.1209/epl/i2006-10069-9 · Cited by 140
Méndez-Vilas, A., Jódar‐Reyes, A. B., & González-Martín, M. L. (2009) · Small · doi:10.1002/smll.200800819 · Cited by 132
Bellon-Fontaine, M. N., Mozes, N., van der Mei, H. C., et al. (1990) · Cell Biochemistry and Biophysics · doi:10.1007/bf02989805 · Cited by 116
Temperature dependence of blood surface tension
Rosina, J., Kvašňák, E., Šuta, D., et al. (2007) · Physiological Research · doi:10.33549/physiolres.931306 · Cited by 92
Adsorption of human salivary proteins to titanium powder. I. Adsorption of human salivary albumin
Steinberg, D., Klinger, A., Kohavi, D., et al. (1995) · Biomaterials · doi:10.1016/0142-9612(95)91050-9 · Cited by 84
Dynamic Contact Angles and Contact Angle Hysteresis of Plasma Polymers
Wang, J.-H., Claesson, P. M., Parker, J. L., & Yasuda, H. K. (1994) · Langmuir · doi:10.1021/la00022a080 · Cited by 68
Scheideler, L., Rupp, F., Wendel, H. P., Sathe, S., & Geis‐Gerstorfer, J. (2006) · Dental Materials · doi:10.1016/j.dental.2006.03.005 · Cited by 56
Self-citationA Guide to the Equilibrium Contact Angles Maze
Marmur, A. (2009) · doi:10.1201/b12247-3 · Cited by 55
Self-citationRupp, F., Axmann, D., Ziegler, C., & Geis‐Gerstorfer, J. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10198 · Cited by 53
Self-citationEichler, M., Katzur, V., Scheideler, L., Haupt, M., Geis‐Gerstorfer, J., Schmalz, G., Rühl, S., Müller, R., & Rupp, F. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.08.063 · Cited by 46
Self-citationRuiz‐Cabello, F. J. M., Rodríguez-Valverde, M. A., Marmur, A., & Cabrerizo-Vílchez, M. Á. (2011) · Langmuir · doi:10.1021/la201248z · Cited by 43
Self-citationHilditch, C. J., McEvoy, R. D., George, K. E., Thompson, C., Ryan, M. K., Rischmueller, M., & CATCHESIDE, P. G. (2008) · SLEEP · doi:10.1093/sleep/31.3.367 · Cited by 42
Park, J. H., Olivares‐Navarrete, R., Wasilewski, C. E., Boyan, B. D., Tannenbaum, R., & Schwartz, Z. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.03.074 · Cited by 37
Self-citationHayashi, M. K., Jimbo, R., Lindh, L., Sotres, J., Sawase, T., Mustafa, K., Andersson, M., & Wennerberg, A. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.03.010 · Cited by 36
Levine, R. A., Sendi, P., & Bornstein, M. M. (2012) · PubMed · Cited by 19
Cited by
Surface characteristics of dental implants: A review
Rupp, F., Liang, L., Geis-Gerstorfer, J., Scheideler, L., & Hüttig, F. (2018) · Dental Materials · doi:10.1016/j.dental.2017.09.007 · Cited by 585
Self-citationHan, X., Yang, D., Yang, C., Spintzyk, S., Scheideler, L., Li, P., Li, D., Geis-Gerstorfer, J., & Rupp, F. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8020240 · Cited by 361
Self-citationYuan, B., Cheng, Q., Zhao, R., Zhu, X., Yang, X., Yang, X., Zhang, K., Song, Y., & Zhang, X. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.04.014 · Cited by 204
Lin, K.-F., He, S., Song, Y., Wang, C.-M., Gao, Y., Li, J.-Q., Tang, P., Wang, Z., Bi, L., & Pei, G.-X. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b00815 · Cited by 176
Jing, Z., Pan, Z., Liang, J., Li, Y., & Mohd Said, F. (2024) · European Polymer Journal · doi:10.1016/j.eurpolymj.2024.112753 · Cited by 16
Metadata
- Authors
- Rupp, F., Gittens, R. A., Scheideler, L., Marmur, A., Boyan, B. D., Schwartz, Z., & Geis-Gerstorfer, J.
- Venue
- Acta Biomaterialia
- Publisher
- Elsevier BV
- Published
- 2014-07
- Volume
- 10
- Issue
- 7
- Pages
- 2894-2906
- ISSN
- 1742-7061 (ISSN-L)
- OpenAlex
- W2091277905
- Cited by
- 507
- References
- 69
- FWCI
- 30.84
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.