The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics
Open accessAbstract
This article demonstrates an instrumented mouthguard capable of non-invasively monitoring salivary uric acid (SUA) levels. The enzyme (uricase)-modified screen printed electrode system has been integrated onto a mouthguard platform along with anatomically-miniaturized instrumentation electronics featuring a potentiostat, microcontroller, and a Bluetooth Low Energy (BLE) transceiver. Unlike RFID-based biosensing systems, which require large proximal power sources, the developed platform enables real-time wireless transmission of the sensed information to standard smartphones, laptops, and other consumer electronics for on-demand processing, diagnostics, or storage. The mouthguard biosensor system offers high sensitivity, selectivity, and stability towards uric acid detection in human saliva, covering the concentration ranges for both healthy people and hyperuricemia patients. The new wireless mouthguard biosensor system is able to monitor SUA level in real-time and continuous fashion, and can be readily expanded to an array of sensors for different analytes to enable an attractive wearable monitoring system for diverse health and fitness applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Wearable saliva biosensors can have different configurations, such as a wireless mouthguard biosensor used by Kim et al. [156] to detect uric acid to prevent diseases such as hyperuricemia, gout, and Lesch–Nyhan syndrome.”
From The emergence of AI-based wearable sensors for digital health technology: a review (2023) · cites this paper as [156]
In the citing paper
“We (J.K., J.W. et al.)36 have further continued development of oral-cavity sensors by demonstrating a mouthguard-based uric acid biosensor that incorporated anatomically miniaturized instrumentation electronics featuring a potentiostat, microcontroller, and a Bluetooth low energy (BLE) transceiver for monitoring salivary uric acid levels toward clinical applications (Fig. 6a).”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [36]
In the citing paper
“This platform enables non-invasive monitoring of blood uric acid levels, which is a biomarker for various diseases (e.g., hyperuricemia, gout and renal syndrome), and it displays highly sensitive, selective, stable and rapid response toward obtaining dynamic chemical data on salivary biomarkers in the oral cavity.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [36]
In the citing paper
“The efficacy of the biosensor was successfully assessed in artificial saliva, undiluted human saliva, and in a hyperuricemia patient with and without medication control.”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [15]
In the citing paper
“The untreated hyperuricemia patient showed a sustained high-SUA level for 5 h (Fig. 1e).”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [15]
In the citing paper
“Several research groups have recently developed mechanically flexible and fully integrated wearable sweat sensors (in wristband, temporary tattoo, eyeglasses, mouthguard) for analysis of biofluid metabolites and electrolytes (e.g., glucose, lactate, sodium, potassium) and pH sensing [156-160].”
From Wearables and the Medical Revolution (2018) · cites this paper as [160]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sontrop, J. M., Dixon, S. N., Garg, A. X., Jiménez, I. B., Dohein, O., Huang, S. S., & Clark, W. F. (2013) · American Journal of Nephrology · doi:10.1159/000350377 · Cited by 5,903
A review of saliva: normal composition, flow, and function.
Humphrey, S. P., & Williamson, R. (2001) · The Journal of prosthetic dentistry (Print) · doi:10.1067/mpr.2001.113778 · Cited by 2,276
Navazesh, M. (1993) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1993.tb18343.x · Cited by 1,449
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Self-citationA causal role for uric acid in fructose-induced metabolic syndrome
Nakagawa, T., Hu, H., Zharikov, S. I., Tuttle, K. R., Short, R., Glushakova, O. Y., Ouyang, X., Feig, D. I., Block, E. R., Herrera-Acosta, J., et al. (2005) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.00140.2005 · Cited by 1,111
Graphene-based wireless bacteria detection on tooth enamel
Mannoor, M. S., Tao, H., Clayton, J. D., Sengupta, A., Kaplan, D. L., Naik, R. R., Verma, N., Omenetto, F. G., & McAlpine, M. C. (2012) · Nature Communications · doi:10.1038/ncomms1767 · Cited by 1,014
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Self-citationSensor and biosensor preparation, optimisation and applications of Prussian Blue modified electrodes
Ricci, F., & Palleschi, G. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.001 · Cited by 781
Wearable Electrochemical Sensors and Biosensors: A Review
Windmiller, J. R., & Wang, J. (2012) · Electroanalysis · doi:10.1002/elan.201200349 · Cited by 717
Self-citationTattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700
Self-citation
Flagged first, then by citations
Research works printed but not linked: 2
- Abikshyeet, 2012, Diabetes Metab. Syndr. Obes., 5, 149
- Graf, 1966, Helv. Odontol. Acta, 10, 94
Cited by
Sorted by citations
Items 301–400 of 679
Huynh, V. L., Trung, T. Q., Meeseepong, M., Lee, H., Nguyen, T. D., & Lee, N. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202004684 · Cited by 37
Hsieh, Y., Lin, C., Lin, H., Kuo, C., Yin, S., Hsu, Y., Yeh, H., Wang, J., & Wan, D. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202300321 · Cited by 38
Self-citationMoradi, S., Firoozbakhtian, A., Hosseini, M., Karaman, O., Kalikeri, S., Raja, G. G., & Karimi‐Maleh, H. (2023) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2023.127577 · Cited by 40
Enhancing the Performance of Wearable Flexible Sensors via Electrospinning
Chung, M., Nirmale, V. S., Reddy, V. S., Koutsos, V., Ramakrishna, S., & Radacsi, N. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5c02129 · Cited by 36
Calabretta, M. M., Zangheri, M., Lopreside, A., Marchegiani, E., Montali, L., Simoni, P., & Roda, A. (2020) · The Analyst · doi:10.1039/c9an02041a · Cited by 38
Piedras, J. J., Dominguez, R. B., & Gutiérrez, J. M. (2021) · Chemosensors · doi:10.3390/chemosensors9040073 · Cited by 36
Current development in wearable glucose meters
Chen, Q., Zhao, Y. J., & Liu, Y. (2021) · Chinese Chemical Letters · doi:10.1016/j.cclet.2021.05.043 · Cited by 40
Liu, Y., Li, H., Feng, Q., Su, H., Li, D., Shang, Y., Chen, H., Li, B., & Dong, H. (2022) · ACS Omega · doi:10.1021/acsomega.2c00128 · Cited by 36
Wireless accessing of salivary biomarkers based wearable electrochemical sensors: A mini-review
Swetha, P., Balijapalli, U., & Feng, S. (2022) · Electrochemistry Communications · doi:10.1016/j.elecom.2022.107314 · Cited by 38
Handrea-Dragan, I. M., Botiz, I., Tatar, A.-S., & Boca, S. (2022) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2022.112730 · Cited by 43
Petrušić, I., Chiang, C., García‐Azorín, D., Ha, W., Ornello, R., Pellesi, L., Rubio‐Beltrán, E., Ruscheweyh, R., Waliszewska‐Prosół, M., & Wells-Gatnik, W. D. (2025) · The Journal of Headache and Pain · doi:10.1186/s10194-024-01944-7 · Cited by 36
A microfluidic patch for wireless wearable electrochemical detection of sweat metabolites
Hu, M., Wang, Z., Zhang, L., Lin, S., & Liao, J. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.136604 · Cited by 35
Giannetto, M., Bianchi, V., Gentili, S., Fortunati, S., Munari, I. D., & Careri, M. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.07.056 · Cited by 35
Advanced Nanoscale Build‐Up Sensors for Daily Life Monitoring of Diabetics
El‐Safty, S. A., & Shenashen, M. A. (2020) · Advanced Materials Interfaces · doi:10.1002/admi.202000153 · Cited by 35
Conductive Materials with Elaborate Micro/Nanostructures for Bioelectronics
Guo, J., Wang, Y., Zhang, H., & Zhao, Y. (2022) · Advanced Materials · doi:10.1002/adma.202110024 · Cited by 35
Song, Y., Shu, C., Song, Z., Zeng, X., Yuan, X., Wang, Y., Xu, J., Feng, Q., Song, T., Shao, B., et al. (2023) · Chemical Engineering Journal · doi:10.1016/j.cej.2023.143797 · Cited by 35
Real Time Analysis of Bioanalytes in Healthcare, Food, Zoology and Botany
Wang, T., Ramnarayanan, A., & Cheng, H. (2017) · Sensors · doi:10.3390/s18010005 · Cited by 34
Micro/nanodevices for assessment and treatment in stomatology and ophthalmology
Sheng, A., Lin, L., Zhu, J., Zhuang, J., Li, J., Chang, L., & Cheng, H. (2021) · Microsystems & Nanoengineering · doi:10.1038/s41378-021-00238-1 · Cited by 34
Bae, C. W., Chinnamani, M. V., Lee, E. H., & Lee, N. (2022) · Advanced Materials Interfaces · doi:10.1002/admi.202200492 · Cited by 35
RoyChoudhury, S., Umasankar, Y., Hutcheson, J. D., Lev‐Tov, H. A., Kirsner, R. S., & Bhansali, S. (2018) · Electroanalysis · doi:10.1002/elan.201800360 · Cited by 34
Microfluidic Wearable Devices for Sports Applications
Ju, F., Wang, Y., Yin, B., Zhao, M., Zhang, Y., Gong, Y., & Jiao, C. (2023) · Micromachines · doi:10.3390/mi14091792 · Cited by 35
Li, Y., Guan, C., Liu, C., Li, Z., & Han, G. (2023) · Talanta · doi:10.1016/j.talanta.2023.125394 · Cited by 33
Patle, S. K., & Rotake, D. R. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.110457 · Cited by 35
Revolutionizing biosensing with wearable microneedle patches: innovations and applications
Rabiee, N. (2025) · Journal of Materials Chemistry B · doi:10.1039/d5tb00251f · Cited by 35
Chen, W., Wang, Z., Wang, L., & Chen, X. S. (2021) · Advanced Materials · doi:10.1002/adma.202106701 · Cited by 33
Ultra‐thin ISFET‐based sensing systems
Baghini, M. S., Vilouras, A., Douthwaite, M., Georgiou, P., & Dahiya, R. (2021) · Electrochemical Science Advances · doi:10.1002/elsa.202100202 · Cited by 33
An Overview on Recent Advances in Biosensor Technology and its Future Application
Fatima, A., Younas, I., & Ali, M. W. (2022) · Archives of Pharmacy Practice · doi:10.51847/ltogi43jil · Cited by 33
Multifunctional Wearable System for Mapping Body Temperature and Analyzing Sweat
Alam, M. S., Kim, J. K., & Choi, J. (2023) · ACS Sensors · doi:10.1021/acssensors.3c00098 · Cited by 35
Self-citationNong, J., Zhang, N., Wen, A., & Hu, C. (2023) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2023.117982 · Cited by 32
A three-level model for therapeutic drug monitoring of antimicrobials at the site of infection
Brasier, N., Ates, H. C., Sempionatto, J. R., Cotta, M. O., Widmer, A. F., Eckstein, J., Goldhahn, J., Roberts, J. A., Gao, W. F., & Dincer, C. (2023) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(23)00215-3 · Cited by 32
Nanoparticles Based on Prussian Blue for Biosensor Applications: A Review
Ma, X., Zhang, T., Wang, X., Zhang, T., Zhang, R., Xu, Z., Ma, M., Ma, Y., & Shi, F. (2023) · ACS Applied Nano Materials · doi:10.1021/acsanm.3c04466 · Cited by 31
Uric acid biosensors based on molecular recognition: Classifications, advances, and prospects
Cheng, J., Wu, Y., Zhu, L., Lin, S., Liu, Y., Huang, K., & Xu, W. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.117887 · Cited by 31
Ma, C., Shang, X., Zhu, Z., Zheng, L., Sun, M., Cao, M., Bai, J., Du, Y., & Zhou, M. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.117889 · Cited by 32
Application of Electrochemical Methods in Biosensing Technologies
Dziąbowska, K., Czaczyk, E., & Nidzworski, D. (2018) · InTech eBooks · doi:10.5772/intechopen.72175 · Cited by 31
Solvent Treatment of Wet-Spun PEDOT: PSS Fibers for Fiber-Based Wearable pH Sensing
Reid, D., Smith, R. E., García‐Torres, J., Watts, J. F., & Crean, C. (2019) · Sensors · doi:10.3390/s19194213 · Cited by 31
市川, 健., & Hijikata, W. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4071777 · Cited by 31
Paper and thread as media for the frugal detection of urinary tract infections (UTIs)
Hasandka, A., Singh, A., Prabhu, A., Singhal, H. R., Nandagopal, M. S. G., & Mani, N. K. (2021) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03671-3 · Cited by 30
CMOS Interfaces for Internet-of-Wearables Electrochemical Sensors: Trends and Challenges
Dei, M., Aymerich, J., Piotto, M., Bruschi, P., del Campo, F. J., & Serra-Graells, F. (2019) · Electronics · doi:10.3390/electronics8020150 · Cited by 29
Wireless Wearable Electrochemical Sensors: A Review
Alves, T., Deroco, P. B., Wachholz, D., Vidotto, L. H. B., & Kubota, L. T. (2021) · Brazilian Journal of Analytical Chemistry · doi:10.30744/brjac.2179-3425.rv-62-2020 · Cited by 30
Development of Flexible Electronic Biosensors for Healthcare Engineering
Zhao, Y. G., Yan, J., Cheng, J., Fu, Y., Zhou, J., Yan, J., & Guo, J. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3287291 · Cited by 30
Oral fluid-based biosensors: A novel method for rapid and noninvasive diagnosis
Lakshmi, K., Nelakurthi, H., Kumar, A., & Amrutha, R. (2017) · Indian Journal of Dental Sciences · doi:10.4103/ijds.ijds_6_17 · Cited by 29
Rind, S., Zhang, N., Khan, W. U., & Zhang, Q. M. (2025) · Wearable electronics. · doi:10.1016/j.wees.2025.08.002 · Cited by 28
Engineering with Biomedical Sciences Changing the Horizon of Healthcare-A Review
Weerarathna, I. N., Kumar, P., Luharia, A. A., & Mishra, G. (2024) · Bioengineered · doi:10.1080/21655979.2024.2401269 · Cited by 29
Novel interfaces for internet of wearable electrochemical sensors
Shahzad, S., Iftikhar, F. J., Shah, A., Rehman, H. A., & Iwuoha, E. I. (2024) · RSC Advances · doi:10.1039/d4ra07165d · Cited by 27
Advances in 2D materials for wearable biomonitoring
Chen, S., Xu, S., Fan, X., Xiao, X., Duan, Z., Zhao, X., Chen, G., Zhou, Y., & Chen, J. (2025) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2025.100971 · Cited by 27
Advanced nanomaterials for health monitoring and diagnostics in next-generation wearable sensors
Chandran, M., Veerapandian, M., Dhanasekaran, B., Govindaraju, S., & Yun, K. (2025) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2025.101015 · Cited by 27
The marriage of biochemistry and nanotechnology for non-invasive real-time health monitoring
Ji, D., Guo, X., Fu, W., Ding, Z., Wang, C., Zhang, Q., Ramakrishna, S., & Qin, X. (2022) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2022.100681 · Cited by 27
Martins, T. S., Bott‐Neto, J. L., Machado, S. A. S., & Oliveira, O. N. (2022) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.2c08381 · Cited by 27
Wearables technology for drug abuse detection: A survey of recent advancement
Mahmud, M. S., Fang, H., Carreiro, S., Wang, H., & Boyer, E. W. (2018) · Smart Health · doi:10.1016/j.smhl.2018.09.002 · Cited by 27
Wearable Orofacial Technology and Orthodontics
Prasad, S., Sivakumar, A., Boillat, T., Ghoneima, A. A. M., Gandedkar, N. H., & Diar-Bakirly, S. (2023) · Dentistry Journal · doi:10.3390/dj11010024 · Cited by 27
Corsato, P. C. R., de Lima, L. F., Paschoarelli, M. V., & de Araujo, W. R. (2024) · Chemosphere · doi:10.1016/j.chemosphere.2024.142771 · Cited by 26
Metal-organic frameworks (MOFs)-based hybrid structures in developing glucose sensors
Sharifabad, A. H., Safavi-Mirmahalleh, S.-A., Golshan, M., Sienkiewicz, M., Saeb, M., & Salami-Kalajahi, M. (2025) · Chemical Engineering Journal · doi:10.1016/j.cej.2025.161513 · Cited by 37
Wackers, G., Putzeys, T., Peeters, M., de Cauter, L. V., Cornelis, P., Wübbenhorst, M., Tack, J. F., Troost, F. J., Verhaert, N., Doll, T., et al. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112152 · Cited by 26
Recent advances in biofluid detection with micro/nanostructured bioelectronic devices
Li, H., Gu, S., Zhang, Q., Song, E., Kuang, T., Chen, F., Yu, X., & Chang, L. (2020) · Nanoscale · doi:10.1039/d0nr07478k · Cited by 26
Kim, M., Kim, S., Kwon, Y. W., Seo, H., Chung, W. G., Kim, E., Park, W., Song, H., Lee, D. H., Lee, J., et al. (2023) · Advanced Sensor Research · doi:10.1002/adsr.202200049 · Cited by 26
Periodontal disease and emerging point-of-care technologies for its diagnosis
Korgaonkar, J., Tarman, A. Y., Koydemir, H. C., & Chukkapalli, S. S. (2024) · Lab on a Chip · doi:10.1039/d4lc00295d · Cited by 27
Vigneshvar, S., & Senthilkumaran, B. (2018) · Medical Devices & Sensors · doi:10.1002/mds3.10011 · Cited by 26
2D Materials‐Based Field‐Effect Transistor Biosensors for Healthcare
Li, J., Wijaya, L. N. A., Jang, D. W., Hu, Y., You, J., Cai, Y., Gao, Z., Mi, Y., & Luo, Z. (2024) · Small · doi:10.1002/smll.202408961 · Cited by 27
Wang, Z., Xiao, X., Yang, C., & Kikkawa, T. (2021) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2021.3124468 · Cited by 25
Sheffield, Z., Paul, P., Krishnakumar, S., & Pan, D. (2024) · Advanced Science · doi:10.1002/advs.202411339 · Cited by 24
Saliva diagnostics: emerging techniques and biomarkers for salivaomics in cancer detection
Liu, J., Huang, D., Cai, Y., Cao, Z., Liu, Z., Zhang, S., Zhao, L. L., Wang, X., Wang, Y., Huang, F., et al. (2022) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2022.2167556 · Cited by 26
Wang, J., Yu, J., Wang, T., Li, C., Wei, Y. Q., Deng, X., & Chen, X. (2019) · Journal of Materials Chemistry B · doi:10.1039/c9tb02352f · Cited by 23
Self-citationNotley, S. R., Meade, R. D., Looney, D. P., Chapman, C. L., Potter, A. W., Fogarty, A. L., Howlader, T., Main, L. C., Friedl, K. E., & Kenny, G. P. (2025) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2024-0395 · Cited by 25
Wearable chemical sensors: Opportunities and challenges
Imani, S., Mercier, P. P., Bandodkar, A. J., Kim, J., & Wang, J. (2016) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2016.7527442 · Cited by 22
Self-citationSuperior Non-Invasive Glucose Sensor Using Bimetallic CuNi Nanospecies Coated Mesoporous Carbon
Radwan, A. B., Paramparambath, S., Cabibihan, J., Al-Ali, A. K., Kasák, P., Shakoor, A., Malik, R. A., Mansour, S. A., & Sadasivuni, K. K. (2021) · Biosensors · doi:10.3390/bios11110463 · Cited by 22
Multifunctional Prussian blue from nano-structure designed to wearable sensors application
Li, R., Zhang, W., Qin, Y., Zhang, Y., Zhu, X., Li, Y., Zhu, N., Hou, C., & Zhang, M. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116729 · Cited by 22
Label‐Free Metal‐Oxide Transistor Biosensors for Metabolite Detection in Human Saliva
Sharma, A., Faber, H. A., AlGhamdi, W. S., Naphade, D. R., Lin, Y., Heeney, M., & Anthopoulos, T. D. (2024) · Advanced Science · doi:10.1002/advs.202306038 · Cited by 22
Towards Closed-Loop Integration of Point-of-Care Technologies
Tan, E. K. W., Au, Y. Z., Moghaddam, G. K., Occhipinti, L. G., & Lowe, C. R. (2019) · Trends in biotechnology · doi:10.1016/j.tibtech.2018.12.004 · Cited by 22
Recent advances of tissue-interfaced chemical biosensors
Chen, C., Guo, Y., Chen, P., & Peng, H. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02476j · Cited by 22
Non-Invasive Glucose Monitoring using Machine Learning
Srinivasan, H. K., Vinupritha, P., & Kathirvelu, D. (2020) · International Conference on Communications and Signal Processing (ICCSP) · doi:10.1109/iccsp48568.2020.9182434 · Cited by 22
RF energy harvesting for intraoral orthodontic force monitoring
Li, P., Zhu, L., Ding, Y., Long, Z., Yang, Y., Pan, J., Gu, M., Wang, W., & Yang, Z. (2023) · Nano Energy · doi:10.1016/j.nanoen.2023.109244 · Cited by 21
Electrochemical carbon-based sensors for non-enzymatic uric acid sensing
Joshi, A., & Slaughter, G. E. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.112331 · Cited by 21
Dewan, M., Shrivastava, D., Srivastava, K. C., Goyal, L., Zwiri, A. M. A., Hussein, A. F., Alam, M. K., & Anil, S. (2024) · European Journal of Dentistry · doi:10.1055/s-0044-1792010 · Cited by 21
Eftekhari, A., Dizaj, S. M., Sharifi, S., Salatin, S., Khalilov, R. I., Samiei, M., Vahed, S. Z., & Ahmadian, E. (2022) · Advances in clinical chemistry · doi:10.1016/bs.acc.2022.06.005 · Cited by 21
The Exposome in the Era of the Quantified Self
Zhang, X., Gao, P., & Snyder, M. P. (2021) · Annual Review of Biomedical Data Science · doi:10.1146/annurev-biodatasci-012721-122807 · Cited by 22
Zhou, J., Zhang, Q., Zhang, M., Aikebaier, S., Zhu, X., & Zhou, X. (2025) · Journal of Advanced Research · doi:10.1016/j.jare.2025.08.036 · Cited by 20
Wearable sensors for health monitoring: Current applications, trends, and future directions
Kurul, F., Aydoğan, D., Janat, S., Kirlangiç, İ. A., Kaya, H. O., & Topkaya, S. N. (2025) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2025.100727 · Cited by 24
Wearable biosensors and sample handling strategies
Parlak, O., Curto, V. F., Ojeda, E., Basabe‐Desmonts, L., Benito‐Lopez, F., & Salleo, A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-08-102407-2.00004-7 · Cited by 20
Masi, S. D., Costa, M., Canfarotta, F., Guerreiro, A. R., Hartley, A., Piletsky, S. A., & Malitesta, C. (2023) · Analytical Methods · doi:10.1039/d3ay01762a · Cited by 20
Wireless Biological Electronic Sensors
Cui, Y. (2017) · Sensors · doi:10.3390/s17102289 · Cited by 20
Perspective—The Feasibility of Continuous Protein Monitoring in Interstitial Fluid
Young, T., Clark, V., Arroyo‐Currás, N., & Heikenfeld, J. C. (2023) · ECS Sensors Plus · doi:10.1149/2754-2726/accd7e · Cited by 20
Advances in Electrochemical Biosensors for the Detection of Common Oral Diseases
Liu, C., Guan, C., Li, Y., Li, Y., Wang, Y., & Han, G. (2024) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2024.2315112 · Cited by 19
Design and manufacturing of soft electronics for in situ biochemical sensing
Xing, Y., Wang, J., & Li, J. (2024) · International Journal of Extreme Manufacturing · doi:10.1088/2631-7990/ad65a0 · Cited by 19
Self-citationVishnu, N., Kumar, A. S., Pan, G., & Yang, T. C. ‐. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.08.022 · Cited by 19
Examining the design, manufacturing and analytics of smart wearables
López, X., Afrin, K., & Nepal, B. P. (2020) · Medical Devices & Sensors · doi:10.1002/mds3.10087 · Cited by 19
Editorial: Current development on wearable biosensors towards biomedical applications
Zhang, S. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1264337 · Cited by 20
Zhao, X., Tanaka, R., Mandour, A. S., Shimada, K., & Hamabe, L. (2025) · Animals · doi:10.3390/ani15071033 · Cited by 18
Tsegay, Z. T., Hosseini, E., D’Amore, T., Smaoui, S., & Varzakas, T. H. (2025) · Biosensors · doi:10.3390/bios15070415 · Cited by 18
Cavitas electrochemical sensors for the direct determination of salivary thiocyanate levels
Sangsawang, R., Thammakhet‐Buranachai, C., Thavarungkul, P., Kanatharana, P., & Jeerapan, I. (2021) · Microchimica Acta · doi:10.1007/s00604-021-05067-7 · Cited by 18
Liu, M., He, D., Liu, Z., & Hu, C. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115312 · Cited by 18
Nanobiosensors for Biomedical Application
Mishra, R. K., & Rajakumari, R. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-814031-4.00001-5 · Cited by 18
A selective voltammetric pH sensor using graphitized mesoporous carbon/polyaniline hybrid system
Saikrithika, S., & Kumar, A. S. (2021) · Journal of Chemical Sciences · doi:10.1007/s12039-021-01908-3 · Cited by 18
Leote, R. J. B., Crisan, D. N., Matei, E., Enculescu, I., & Diculescu, V. C. (2024) · ACS Applied Polymer Materials · doi:10.1021/acsapm.3c02811 · Cited by 17
Advancements in enzyme-based wearable sensors for health monitoring
Mehrotra, S., Rai, P., Saxena, A., Priya, S., & Sharma, S. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.110250 · Cited by 17
Smart Contact Lens for Colorimetric Visualization of Glucose Levels in the Body Fluid
Seo, J., Kang, J., Kim, J., Han, H.-J., Park, M., Shin, M., & Lee, K. (2024) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.4c00431 · Cited by 17
Self-citationXu, D., Yang, Y., Numata, K., & Pang, B. (2026) · Nano-Micro Letters · doi:10.1007/s40820-025-02059-7 · Cited by 17
A flexible micro direct methanol fuel cells array based on FPCB
Zhu, J., Yu, J., Yin, L., Yang, W., Liu, H., Wang, G., Wang, L., & Cai, W. (2022) · Energy Conversion and Management · doi:10.1016/j.enconman.2022.115469 · Cited by 17
Ornelas‐González, A., Rito‐Palomares, M., & González‐González, M. (2022) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.7165 · Cited by 16
Waghmare, A., Parizi, F. S., Hoffman, J. S., Wang, Y., Thompson, M. J., & Patel, S. (2023) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3580855 · Cited by 16
Perspective of Printed Solid‐State Ion Sensors toward High Sensitivity and Selectivity
Bao, C., & Kim, W. S. (2020) · Advanced Engineering Materials · doi:10.1002/adem.202000116 · Cited by 17
Metadata
- Authors
- Kim, J., Imani, S., de Araujo, W. R., Warchall, J., Valdés-Ramírez, G., Paixão, T. R. L. C., Mercier, P. P., & Wang, J.
- Affiliations
- University of California System (US)
- Universidade de São Paulo (BR)
- Corresponding author
- Mercier, Patrick P.
- Wang, Joseph
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2015-12
- Volume
- 74
- Pages
- 1061-1068
- ISSN
- 0956-5663 (ISSN-L)
- PMC
- PMC4718709
- OpenAlex
- W1034491903
- Cited by
- 678
- References
- 54
- Citations by year
- 2026: 49 · 2025: 78 · 2024: 83 · 2023: 74 · 2022: 95 · 2021: 84 · 2020: 74 · 2019: 50 · 2018: 42 · 2017: 26 · 2016: 22 · 2015: 1
- FWCI
- 14.63
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Biosensors and Bioelectronics (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Funders
- National Institute of Biomedical Imaging and Bioengineering of NIH (R21EB019698)
- Air Force Research Laboratory (through the FlexTech Consortium -LTR SUBK
- FAPESP-BEPE (2014/00788-0)
- NSF Graduate Research Fellowship (DGE-1144086)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Keywords
- salivary uric acid, uric acid biosensor, mouthguards, wearable biosensors, uricase, screen-printed electrodes, wireless devices, Bluetooth Low Energy, hyperuricemia, real-time monitoring, non-invasive monitoring, potentiostat, microcontroller
- MeSH terms
- Computer Communication Networks, Conductometry, Equipment Design, Humans, Mouth Protectors, Saliva, Sensitivity and Specificity, Uric Acid, Reproducibility of Results, Biosensing Techniques, Systems Integration, Monitoring, Ambulatory, Equipment Failure Analysis, Hyperuricemia, Wireless Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review