The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics
Open accessAbstract
This article demonstrates an instrumented mouthguard capable of non-invasively monitoring salivary uric acid (SUA) levels. The enzyme (uricase)-modified screen printed electrode system has been integrated onto a mouthguard platform along with anatomically-miniaturized instrumentation electronics featuring a potentiostat, microcontroller, and a Bluetooth Low Energy (BLE) transceiver. Unlike RFID-based biosensing systems, which require large proximal power sources, the developed platform enables real-time wireless transmission of the sensed information to standard smartphones, laptops, and other consumer electronics for on-demand processing, diagnostics, or storage. The mouthguard biosensor system offers high sensitivity, selectivity, and stability towards uric acid detection in human saliva, covering the concentration ranges for both healthy people and hyperuricemia patients. The new wireless mouthguard biosensor system is able to monitor SUA level in real-time and continuous fashion, and can be readily expanded to an array of sensors for different analytes to enable an attractive wearable monitoring system for diverse health and fitness applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Wearable saliva biosensors can have different configurations, such as a wireless mouthguard biosensor used by Kim et al. [156] to detect uric acid to prevent diseases such as hyperuricemia, gout, and Lesch–Nyhan syndrome.”
From The emergence of AI-based wearable sensors for digital health technology: a review (2023) · cites this paper as [156]
In the citing paper
“We (J.K., J.W. et al.)36 have further continued development of oral-cavity sensors by demonstrating a mouthguard-based uric acid biosensor that incorporated anatomically miniaturized instrumentation electronics featuring a potentiostat, microcontroller, and a Bluetooth low energy (BLE) transceiver for monitoring salivary uric acid levels toward clinical applications (Fig. 6a).”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [36]
In the citing paper
“This platform enables non-invasive monitoring of blood uric acid levels, which is a biomarker for various diseases (e.g., hyperuricemia, gout and renal syndrome), and it displays highly sensitive, selective, stable and rapid response toward obtaining dynamic chemical data on salivary biomarkers in the oral cavity.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [36]
In the citing paper
“The efficacy of the biosensor was successfully assessed in artificial saliva, undiluted human saliva, and in a hyperuricemia patient with and without medication control.”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [15]
In the citing paper
“The untreated hyperuricemia patient showed a sustained high-SUA level for 5 h (Fig. 1e).”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [15]
In the citing paper
“Several research groups have recently developed mechanically flexible and fully integrated wearable sweat sensors (in wristband, temporary tattoo, eyeglasses, mouthguard) for analysis of biofluid metabolites and electrolytes (e.g., glucose, lactate, sodium, potassium) and pH sensing [156-160].”
From Wearables and the Medical Revolution (2018) · cites this paper as [160]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sontrop, J. M., Dixon, S. N., Garg, A. X., Jiménez, I. B., Dohein, O., Huang, S. S., & Clark, W. F. (2013) · American Journal of Nephrology · doi:10.1159/000350377 · Cited by 5,903
A review of saliva: normal composition, flow, and function.
Humphrey, S. P., & Williamson, R. (2001) · The Journal of prosthetic dentistry (Print) · doi:10.1067/mpr.2001.113778 · Cited by 2,276
Navazesh, M. (1993) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1993.tb18343.x · Cited by 1,449
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Self-citationA causal role for uric acid in fructose-induced metabolic syndrome
Nakagawa, T., Hu, H., Zharikov, S. I., Tuttle, K. R., Short, R., Glushakova, O. Y., Ouyang, X., Feig, D. I., Block, E. R., Herrera-Acosta, J., et al. (2005) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.00140.2005 · Cited by 1,111
Graphene-based wireless bacteria detection on tooth enamel
Mannoor, M. S., Tao, H., Clayton, J. D., Sengupta, A., Kaplan, D. L., Naik, R. R., Verma, N., Omenetto, F. G., & McAlpine, M. C. (2012) · Nature Communications · doi:10.1038/ncomms1767 · Cited by 1,014
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Self-citationSensor and biosensor preparation, optimisation and applications of Prussian Blue modified electrodes
Ricci, F., & Palleschi, G. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.001 · Cited by 781
Wearable Electrochemical Sensors and Biosensors: A Review
Windmiller, J. R., & Wang, J. (2012) · Electroanalysis · doi:10.1002/elan.201200349 · Cited by 717
Self-citationTattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700
Self-citationHigh Serum Uric Acid as a Novel Risk Factor for Type 2 Diabetes
Dehghan, A., van Hoek, M., Sijbrands, E. J. G., Albert Hofman, D., & Witteman, J. C. M. (2008) · Diabetes Care · doi:10.2337/dc07-1276 · Cited by 654
Malitesta, C., Palmisano, F., Torsi, L., & Zambonin, P. G. (1990) · Analytical Chemistry · doi:10.1021/ac00223a016 · Cited by 570
Bandodkar, A. J., Molinnus, D., Mirza, O., Guinovart, T., Windmiller, J. R., Valdés-Ramírez, G., Andrade, F. J., Schöning, M. J., & Wang, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.039 · Cited by 490
Self-citationFrom Wearable Sensors to Smart Implants-–Toward Pervasive and Personalized Healthcare
Andreu-Pérez, J., Leff, D. R., Ip, H. M. D., & Yang, G. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2422751 · Cited by 393
Tattoo-based potentiometric ion-selective sensors for epidermal pH monitoring
Bandodkar, A. J., Hung, V. W. S., Jia, W., Valdés-Ramírez, G., Windmiller, J. R., Martinez, A. G., Ramírez, J., Chan, G., Kerman, K., & Wang, J. (2013) · The Analyst · doi:10.1039/c2an36422k · Cited by 379
Self-citationNon-invasive mouthguard biosensor for continuous salivary monitoring of metabolites
Kim, J., Valdés-Ramírez, G., Bandodkar, A. J., Jia, W., Martinez, A. G., Ramírez, J., Mercier, P., & Wang, J. (2014) · The Analyst · doi:10.1039/c3an02359a · Cited by 367
Self-citationSaliva Composition and Exercise
Chicharro, J. L., Lucía, A., Pérez, M., Vaquero, A. F., & Ureña, R. (1998) · Sports Medicine · doi:10.2165/00007256-199826010-00002 · Cited by 345
Smart bandage with wireless connectivity for uric acid biosensing as an indicator of wound status
Kassal, P., Kim, J., Kumar, R., de Araujo, W. R., Steinberg, I. M., Steinberg, M. D., & Wang, J. (2015) · Electrochemistry Communications · doi:10.1016/j.elecom.2015.03.018 · Cited by 326
Self-citationSerum Uric Acid Levels and the Risk of Type 2 Diabetes: A Prospective Study
Bhole, V., Choi, J. W. J., Kim, S. W., Vera, M. A. D., & Choi, H. K. (2010) · The American Journal of Medicine · doi:10.1016/j.amjmed.2010.03.027 · Cited by 325
Advances in wearable chemical sensor design for monitoring biological fluids
Matzeu, G., Florea, L., & Diamond, D. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.01.077 · Cited by 307
Wearable Wireless Health Monitoring: Current Developments, Challenges, and Future Trends
Soh, P. J., Vandenbosch, G. A. E., Mercuri, M., & Schreurs, D. M. M.-P. (2015) · IEEE Microwave Magazine · doi:10.1109/mmm.2015.2394021 · Cited by 253
Wearable temporary tattoo sensor for real-time trace metal monitoring in human sweat
Kim, J., de Araujo, W. R., Samek, I. A., Bandodkar, A. J., Jia, W., Brunetti, B., Paixão, T. R. L. C., & Wang, J. (2015) · Electrochemistry Communications · doi:10.1016/j.elecom.2014.11.024 · Cited by 245
Self-citationA contact lens with an integrated lactate sensor
Thomas, N., Lähdesmäki, I., & Parviz, B. A. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.12.049 · Cited by 220
Corrie, S. R., Coffey, J. W., Islam, J., Markey, K. A., & Kendall, M. A. F. (2015) · The Analyst · doi:10.1039/c5an00464k · Cited by 220
A review of enzymatic uric acid biosensors based on amperometric detection
Erden, P. E., & Kılıç, E. (2013) · Talanta · doi:10.1016/j.talanta.2013.01.043 · Cited by 209
Yao, H., Liao, Y., Lingley, A. R., Afanasiev, A., Lähdesmäki, I., Otis, B. P., & Parviz, B. A. (2012) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/22/7/075007 · Cited by 182
The genetic basis of hyperuricaemia and gout
Merriman, T. R., & Dalbeth, N. (2010) · Joint Bone Spine · doi:10.1016/j.jbspin.2010.02.027 · Cited by 180
Glucose estimation in the salivary secretion of diabetes mellitus patients
Panda, A., Ramesh, & Oza (2012) · Diabetes Metabolic Syndrome and Obesity · doi:10.2147/dmso.s32112 · Cited by 158
Zhang, D., Jiang, J., Chen, J., Zhang, Q. Y., Lu, Y., Yao, Y., Li, S., Liu, G. L., & Liu, Q. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.03.004 · Cited by 141
Salivary uric acid as a noninvasive biomarker of metabolic syndrome
Soukup, M., Biesiada, I., Henderson, A. T., Idowu, B., Rodeback, D., Ridpath, L. C., Bridges, E. G., Nazar, A. M., & Bridges, K. G. (2012) · Diabetology & Metabolic Syndrome · doi:10.1186/1758-5996-4-14 · Cited by 140
The recognition of Lesch‐Nyhan syndrome as an inborn error of purine metabolism
Nyhan, W. L. (1997) · Journal of Inherited Metabolic Disease · doi:10.1023/a:1005348504512 · Cited by 136
Oxidation of urate in human skeletal muscle during exercise
Hellsten, Y., Tullson, P. C., Richter, E. A., & Bangsbo, J. (1997) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(96)00286-9 · Cited by 136
Falasca, G. F. (2006) · Clinics in Dermatology · doi:10.1016/j.clindermatol.2006.07.015 · Cited by 129
Wireless Integrated Biosensors for Point-of-Care Diagnostic Applications
Ghafar‐Zadeh, E. (2015) · Sensors · doi:10.3390/s150203236 · Cited by 122
Piermarini, S., Migliorelli, D., Volpe, G., Massoud, R., Pierantozzi, A., Cortese, C., & Palleschi, G. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.10.090 · Cited by 100
Disposable electrochemiluminescent biosensor for lactate determination in saliva
Ballesta Claver, J., Valencia Mirón, M. C., & Capitán-Vallvey, L. F. (2009) · The Analyst · doi:10.1039/b821922b · Cited by 93
Telemetry of plaque pH from interdental area.
Graf, H., & Hr, M. (1966) · PubMed · Cited by 82
Diamond, D., Lau, K. T., Brady, S. A., & Cleary, J. (2007) · Talanta · doi:10.1016/j.talanta.2007.11.022 · Cited by 77
Wireless enzyme sensor system for real-time monitoring of blood glucose levels in fish
Endo, H., Yonemori, Y., Hibi, K., Ren, H., Hayashi, T., Tsugawa, W., & Sode, K. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.08.038 · Cited by 76
Wireless smart tag with potentiometric input for ultra low-power chemical sensing
Kassal, P., Steinberg, I. M., & Steinberg, M. D. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.04.049 · Cited by 75
Shibasaki, K., Kimura, M., Ikarashi, R., Yamaguchi, A., & Watanabe, T. (2011) · Metabolomics · doi:10.1007/s11306-011-0334-z · Cited by 74
da Costa, A. M., Igualaacute, I., Bedini, J. L., Quintoacute, L., & Conget, I. (2002) · Metabolism · doi:10.1053/meta.2002.30523 · Cited by 72
A potentiometric disposable sensor strip for measuring pH in saliva
Zuliani, C., Matzeu, G., & Diamond, D. (2014) · Electrochimica Acta · doi:10.1016/j.electacta.2014.03.140 · Cited by 67
A study of ascorbic acid in human saliva
Mäkilä, E., & Kirveskari, P. (1969) · Archives of Oral Biology · doi:10.1016/0003-9969(69)90201-5 · Cited by 52
Polyaniline/Prussian‐Blue‐Based Amperometric Biosensor for Detection of Uric Acid
Thakur, B., & Sawant, S. N. (2012) · ChemPlusChem · doi:10.1002/cplu.201200222 · Cited by 49
Salivary urate in gout, exercise, and diurnal variation
Owen-Smith, B., Quiney, J., & Read, J. (1998) · The Lancet · doi:10.1016/s0140-6736(05)78616-5 · Cited by 45
Depari, A., Flammini, A., Rinaldi, S., & Vezzoli, A. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.05.001 · Cited by 45
Diagnostic Implications of Uric Acid in Electroanalytical Measurements
Dutt, J. S. N., Cardosi, M. F., Livingstone, C., & Davis, J. (2005) · Electroanalysis · doi:10.1002/elan.200403258 · Cited by 45
Oral telemetry of fluoride ion activity
Graf, H., & Mühlemann, H. R. (1969) · Archives of Oral Biology · doi:10.1016/0003-9969(69)90228-3 · Cited by 39
Moran, M. E. (2003) · Frontiers in bioscience · doi:10.2741/1178 · Cited by 37
A comparison of serum and saliva paracetamol concentrations.
Smith, M., Whitehead, E., O’Sullivan, G., & Reynolds, F. (1991) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.1991.tb05580.x · Cited by 36
Zloczower, M., Reznick, A. Z., Zouby, R. O., & Nagler, R. M. (2007) · Antioxidants and Redox Signaling · doi:10.1089/ars.2007.1515 · Cited by 34
Chu, Q., Lin, M., Geng, C., & Ye, J. N. (2006) · Chromatographia · doi:10.1365/s10337-006-0142-1 · Cited by 31
Wireless Biosensor System for Real-Time L-Lactic Acid Monitoring in Fish
Hibi, K., Hatanaka, K., Takase, M., Ren, H., & Endo, H. (2012) · Sensors · doi:10.3390/s120506269 · Cited by 29
Flagged first, then by citations
Research works printed but not linked: 2
- Abikshyeet, 2012, Diabetes Metab. Syndr. Obes., 5, 149
- Graf, 1966, Helv. Odontol. Acta, 10, 94
Cited by
Sorted by citations
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Self-citationBariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Self-citationBio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Metadata
- Authors
- Kim, J., Imani, S., de Araujo, W. R., Warchall, J., Valdés-Ramírez, G., Paixão, T. R. L. C., Mercier, P. P., & Wang, J.
- Affiliations
- University of California System (US)
- Universidade de São Paulo (BR)
- Corresponding author
- Mercier, Patrick P.
- Wang, Joseph
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2015-12
- Volume
- 74
- Pages
- 1061-1068
- ISSN
- 0956-5663 (ISSN-L)
- PMC
- PMC4718709
- OpenAlex
- W1034491903
- Cited by
- 678
- References
- 54
- Citations by year
- 2026: 49 · 2025: 78 · 2024: 83 · 2023: 74 · 2022: 95 · 2021: 84 · 2020: 74 · 2019: 50 · 2018: 42 · 2017: 26 · 2016: 22 · 2015: 1
- FWCI
- 14.63
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Biosensors and Bioelectronics (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Funders
- National Institute of Biomedical Imaging and Bioengineering of NIH (R21EB019698)
- Air Force Research Laboratory (through the FlexTech Consortium -LTR SUBK
- FAPESP-BEPE (2014/00788-0)
- NSF Graduate Research Fellowship (DGE-1144086)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Keywords
- salivary uric acid, uric acid biosensor, mouthguards, wearable biosensors, uricase, screen-printed electrodes, wireless devices, Bluetooth Low Energy, hyperuricemia, real-time monitoring, non-invasive monitoring, potentiostat, microcontroller
- MeSH terms
- Computer Communication Networks, Conductometry, Equipment Design, Humans, Mouth Protectors, Saliva, Sensitivity and Specificity, Uric Acid, Reproducibility of Results, Biosensing Techniques, Systems Integration, Monitoring, Ambulatory, Equipment Failure Analysis, Hyperuricemia, Wireless Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review