Recent progress in energy harvesting systems for wearable technology
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
This paper provides a comprehensive review of the recent progress made in energy harvesting systems for wearable technology. An energy-harvesting system would be a useful strategy to address the issue of powering wearable electronic devices. This review presents different wearable energy harvesting methods based on the human body's heat and mechanical energy. To achieve continuous operation and high performance, reduce the requirement for external sources of energy, and enhance the lifespan of wearable devices, the invention of a sustainable and compatible power supply is required. In the human body, heat and mechanical motions are the two reliable and readily available energy sources. This study highlights the most recent research and advancements in energy harvesting from the human's mechanical motion and heat source. This article provides a detailed overview of the different wearable energy harvesters, their fabrication, working, and output results, which include piezoelectric, electrostatic, triboelectric, electromagnetic, thermoelectric, solar and hybrid wearable energy harvesters. The second part defines wearable energy harvesting using smart systems and artificial intelligence technology. Then the comparison of these energy harvesters is analyzed. Hybrid wearable energy harvesters provide the maximum power densities because they use two combined energy conversions. The advantages, limitations, and future perspectives of wearable energy harvesting technology are also discussed. Lastly, the wearable energy harvesters' market, and general developing and manufacturing cost of each wearable device is also presented functioning as a point of reference to comprehend the cost factors that are taken into account during the development and manufacturing processes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flexible triboelectric generator
Fan, F.-R., Tian, Z.-Q., & Lin Wang, Z. (2012) · Nano Energy · doi:10.1016/j.nanoen.2012.01.004 · Cited by 6,705
Stretchable, Skin-Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review
Amjadi, M., Kyung, K., Park, I., & Sitti, M. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504755 · Cited by 3,202
Wearable Electronics and Smart Textiles: A Critical Review
Stoppa, M., & Chiolerio, A. (2014) · Sensors · doi:10.3390/s140711957 · Cited by 2,107
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
Wearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
Advances of flexible pressure sensors toward artificial intelligence and health care applications
Zang, Y., Zhang, F., Di, C.-A., & Zhu, D. (2015) · Materials Horizons · doi:10.1039/c4mh00147h · Cited by 1,272
Big data and its technical challenges.
Jagadish, H. V., Gehrke, J., Labrinidis, A., Papakonstantinou, Y., Patel, J. M., Ramakrishnan, R., & Shahabi, C. (2014) · Communications of the ACM · doi:10.1145/2611567 · Cited by 1,048
Human-powered wearable computing
Starner, T. (1996) · IBM Systems Journal · doi:10.1147/sj.353.0618 · Cited by 876
Flexible High-Output Nanogenerator Based on Lateral ZnO Nanowire Array
Zhu, G., Yang, R., Wang, S., & Wang, Z. L. (2010) · Nano Letters · doi:10.1021/nl101973h · Cited by 805
Yu, Y., Nassar, J., Xu, C., Min, J., Yang, Y., Dai, A., Doshi, R., Huang, A., Song, Y., Gehlhar, R., et al. (2020) · Science Robotics · doi:10.1126/scirobotics.aaz7946 · Cited by 655
Electromagnetic generator for harvesting energy from human motion
Saha, C. R., O’Donnell, T., Wang, N., & McCloskey, P. (2008) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2008.03.008 · Cited by 608
Machine-knitted washable sensor array textile for precise epidermal physiological signal monitoring
Fan, W., He, Q., Meng, K., Tan, X., Zhou, Z., Zhang, G., Yang, J., & Wang, Z. L. (2020) · Science Advances · doi:10.1126/sciadv.aay2840 · Cited by 516
Yang, Y., Pan, H., Xie, G., Jiang, Y., Chen, C., Su, Y., Wang, Y., & Tai, H. (2020) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2019.111789 · Cited by 496
Paper‐Based Electrical Respiration Sensor
Güder, F., Ainla, A., Redston, J., Mosadegh, B., Glavan, A., Martin, T. J., & Whitesides, G. M. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201511805 · Cited by 472
Hierarchically patterned self-powered sensors for multifunctional tactile sensing
Wang, Y., Wu, H., Xu, L., Zhang, H., Yang, Y., & Wang, Z. L. (2020) · Science Advances · doi:10.1126/sciadv.abb9083 · Cited by 425
Relation between blood pressure and pulse wave velocity for human arteries
Ma, Y., Choi, J., Hourlier-Fargette, A., Xue, Y., Chung, H. U., Lee, J. Y., Wang, X., Xie, Z., Kang, D., Wang, H., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1814392115 · Cited by 309
Sim, K., Rao, Z., Zou, Z., Ershad, F., Lei, J., Thukral, A., Chen, J., Huang, Q.-A., Xiao, J., & Yu, C. (2019) · Science Advances · doi:10.1126/sciadv.aav9653 · Cited by 305
A piezoelectric fibre composite based energy harvesting device for potential wearable applications
Swallow, L. M., Luo, J. K., Siores, E., Patel, I., & Dodds, D. (2008) · Smart Materials and Structures · doi:10.1088/0964-1726/17/2/025017 · Cited by 208
Wearable textile biofuel cells for powering electronics
Jia, W., Wang, X., Imani, S., Bandodkar, A. J., Ramírez, J., Mercier, P. P., & Wang, J. (2014) · J. Mater. Chem. A · doi:10.1039/c4ta04796f · Cited by 184
Design, manufacturing and applications of wearable triboelectric nanogenerators
Wang, H., Han, M., Song, Y., & Zhang, H. (2021) · Nano Energy · doi:10.1016/j.nanoen.2020.105627 · Cited by 179
Survey of energy scavenging for wearable and implantable devices
Ghomian, T., & Mehraeen, S. (2019) · Energy · doi:10.1016/j.energy.2019.04.088 · Cited by 126
AlN-based flexible piezoelectric skin for energy harvesting from human motion
Guido, F., Qualtieri, A., Algieri, L., Lemma, E. D., De Vittorio, M., & Todaro, M. T. (2016) · Microelectronic Engineering · doi:10.1016/j.mee.2016.03.041 · Cited by 83
Cited by
A review of green artificial intelligence: Towards a more sustainable future
Bolón-Canedo, V., Morán-Fernández, L., Cancela, B., & Alonso-Betanzos, A. (2024) · Neurocomputing · doi:10.1016/j.neucom.2024.128096 · Cited by 486
Metadata
- Authors
- Ali, A., Shaukat, H., Bibi, S., Altabey, W. A., Noori, M., & Kouritem, S. A.
- Venue
- Energy Strategy Reviews
- Publisher
- Elsevier BV
- Published
- 2023-09
- Volume
- 49
- Pages
- 101124
- ISSN
- 2211-467X (ISSN-L)
- OpenAlex
- W4384436418
- Cited by
- 238
- References
- 22
- FWCI
- 23.41
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.