CoChat

A proposed model membrane and test method for microneedle insertion studies

Larrañeta, Eneko, Moore, Jessica, Vicente-Pérez, Eva M., González-Vázquez, Patricia, Lutton, Rebecca, Woolfson, A. David, Donnelly, Ryan F. · 2014 · International Journal of Pharmaceutics
Cited by 603

The DOI matches its Crossref record.

Abstract

A commercial polymeric film (Parafilm M(®), a blend of a hydrocarbon wax and a polyolefin) was evaluated as a model membrane for microneedle (MN) insertion studies. Polymeric MN arrays were inserted into Parafilm M(®) (PF) and also into excised neonatal porcine skin. Parafilm M(®) was folded before the insertions to closely approximate thickness of the excised skin. Insertion depths were evaluated using optical coherence tomography (OCT) using either a force applied by a Texture Analyser or by a group of human volunteers. The obtained insertion depths were, in general, slightly lower, especially for higher forces, for PF than for skin. However, this difference was not a large, being less than the 10% of the needle length. Therefore, all these data indicate that this model membrane could be a good alternative to biological tissue for MN insertion studies. As an alternative method to OCT, light microscopy was used to evaluate the insertion depths of MN in the model membrane. This provided a rapid, simple method to compare different MN formulations. The use of Parafilm M(®), in conjunction with a standardised force/time profile applied by a Texture Analyser, could provide the basis for a rapid MN quality control test suitable for in-process use. It could also be used as a comparative test of insertion efficiency between candidate MN formulations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ijpharm.2014.05.042

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 30

  1. Badran, 2009, Skin penetration enhancement by a microneedle device (Dermaroller) in vitro: dependency on needle size and applied formulation, Eur. J. Pharm. Sci., 36, 511, 10.1016/j.ejps.2008.12.008 · DOI · Paper page
  2. Bal, 2008, In vivo assessment of safety of microneedle arrays in human skin, Eur. J. Pharm. Sci., 35, 193, 10.1016/j.ejps.2008.06.016 · DOI · Paper page
  3. Chandrasekhar, 2013, Microarrays and microneedle arrays for delivery of peptides, proteins, vaccines and other applications, Expert Opin. Drug Deliv., 10, 1155, 10.1517/17425247.2013.797405 · DOI
  4. Coulman, 2011, In vivo, in situ imaging of microneedle insertion into the skin of human volunteers using optical coherence tomography, Pharm. Res., 28, 66, 10.1007/s11095-010-0167-x · DOI
  5. Davis, 2004, Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force, J. Biomech., 37, 1155, 10.1016/j.jbiomech.2003.12.010 · DOI · Paper page
  6. Donnelly, 2009, Microneedle arrays allow lower microbial penetration than hypodermic needles in vitro, Pharm. Res., 26, 2513, 10.1007/s11095-009-9967-2 · DOI · Paper page
  7. Donnelly, 2010, Optical coherence tomography is a valuable tool in the study of the effects of microneedle geometry on skin penetration characteristics and in-skin dissolution, J. Control. Release, 147, 333, 10.1016/j.jconrel.2010.08.008 · DOI · Paper page
  8. Donnelly, 2011, Design, optimization and characterisation of polymeric microneedle arrays prepared by a novel laser-based micromoulding technique, Pharm. Res., 28, 41, 10.1007/s11095-010-0169-8 · DOI · Paper page
  9. Donnelly, 2012, Hydrogel-forming microneedle arrays for enhanced transdermal drug delivery, Adv. Funct. Mater., 22, 4879, 10.1002/adfm.201200864 · DOI · Paper page
  10. Donnelly, 2014, Hydrogel-forming microneedle arrays can be effectively inserted in skin by self-application: a pilot study centred on pharmacist intervention and a patient information leaflet, Pharm. Res., 1
  11. Garland, 2011, Electrically enhanced solute permeation across poly(ethylene glycol)-crosslinked poly(methyl vinyl ether-co-maleic acid) hydrogels: effect of hydrogel crosslink density and ionic conductivity, Int. J. Pharm., 406, 91, 10.1016/j.ijpharm.2011.01.002 · doi:10.1016/j.ijpharm.2011.01.002
  12. Garland, 2012, Influence of skin model on in vitro performance of drug-loaded soluble microneedle arrays, Int. J. Pharm., 434, 80, 10.1016/j.ijpharm.2012.05.069 · DOI
  13. Henry, 1998, Microfabricated microneedles: a novel approach to transdermal drug delivery, J. Pharm. Sci., 87, 922, 10.1021/js980042+ · DOI · Paper page
  14. Kim, 2012, Microneedles for drug and vaccine delivery, Adv. Drug Deliv. Rev., 64, 1547, 10.1016/j.addr.2012.04.005 · DOI · Paper page
  15. Koelmans, 2013, Microneedle characterization using a double-layer skin simulant, Mech. Eng. Res., 3, 51, 10.5539/mer.v3n2p51 · DOI
  16. Kong, 2011, Numerical simulation of microneedles’ insertion into skin, Comput. Methods Biomech. Biomed. Eng., 14, 827, 10.1080/10255842.2010.497144 · DOI
  17. Meyer, 1996, Porcine skin as biological model for the human integument, Hautarzt, 47, 178, 10.1007/s001050050399 · DOI
  18. Migalska, 2011, Laser-engineered dissolving microneedle arrays for transdermal macromolecular drug delivery, Pharm. Res., 28, 1919, 10.1002/jps.23724 · DOI · Paper page
  19. Ng, 2012, The relevance of polymeric synthetic membranes in topical formulation assessment and drug diffusion study, Arch. Pharm. Res., 35, 579, 10.1007/s12272-012-0401-7 · doi:10.1007/s12272-012-0401-7
  20. Oh, 2008, Influence of the delivery systems using a microneedle array on the permeation of a hydrophilic molecule, calcein, Eur. J. Pharm. Biopharm., 69, 1040, 10.1016/j.ejpb.2008.02.009 · DOI
  21. Park, 2005, Biodegradable polymer microneedles: fabrication, mechanics and transdermal drug delivery, J. Control. Release, 104, 51, 10.1016/j.jconrel.2005.02.002 · DOI · Paper page
  22. Prausnitz, 2004, Microneedles for transdermal drug delivery, Adv. Drug Deliv. Rev., 56, 581, 10.1016/j.addr.2003.10.023 · DOI · Paper page
  23. Singh, 2009, Investigation of swelling and network parameters of poly(ethylene glycol)-crosslinked poly(methyl vinyl ether-co-maleic acid) hydrogels, Eur. Polym. J., 45, 1239, 10.1016/j.eurpolymj.2008.12.019 · DOI
  24. Singh, 2010, Investigation of solute permeation across hydrogels composed of poly(methyl vinyl ether-co-maleic acid) and poly(ethylene glycol), J. Pharm. Pharmacol., 62, 829, 10.1211/jpp.62.07.0003 · doi:10.1211/jpp.62.07.0003
  25. Tuan-Mahmood, 2013, Microneedles for intradermal and transdermal drug delivery, Eur. J. Pharm. Sci., 50, 623, 10.1016/j.ejps.2013.05.005 · DOI · Paper page
  26. Vedrine, 2003, Improving needle-point sharpness in prefillable syringes, Med. Device Technol., 14, 32
  27. Verbaan, 2008, Improved piercing of microneedle arrays in dermatomed human skin by an impact insertion method, J. Control. Release, 128, 80, 10.1016/j.jconrel.2008.02.009 · DOI · Paper page
  28. Wang, 2006, Precise microinjection into skin using hollow microneedles, J. Invest. Dermatol., 126, 1080, 10.1038/sj.jid.5700150 · DOI · Paper page
  29. Widera, 2006, Effect of delivery parameters on immunization to ovalbumin following intracutaneous administration by a coated microneedle array patch system, Vaccine, 24, 1653, 10.1016/j.vaccine.2005.09.049 · DOI · Paper page
  30. Zhang, 2014, Microneedle assisted micro-particle delivery from gene guns: experiments using skin-mimicking agarose gel, J. Pharm. Sci., 10.1002/jps.23835 · DOI · Paper page

Cited by

Metadata

Authors
Larrañeta, E., Moore, J., Vicente-Pérez, E. M., González-Vázquez, P., Lutton, R., Woolfson, A. D., & Donnelly, R. F.
Venue
International Journal of Pharmaceutics
Publisher
Elsevier BV
Published
2014-09
Volume
472
Issue
1-2
Pages
65-73
ISSN
0378-5173
Cited by
603
References
0
Language
en
Licence
Funders
  • Biotechnology and Biological Sciences Research Council (BB/K020234/1)
  • Wellcome Trust (WT094085MA)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.