Gait posture estimation using wearable acceleration and gyro sensors
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A gait analysis data collection and reduction technique
Davis, R. B., Õunpuu, S., Tyburski, D., & Gage, J. R. (1991) · Human Movement Science · doi:10.1016/0167-9457(91)90046-z · Cited by 3,086
Bouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911 · cited 1×
“Such inertial sensors allow measurements to be made outside the laboratory environment (Veltink et al., 1996; Bouten et al., 1997; Bussmann et al., 1998; Foerster et al., 1999).”
BackgroundAssessment of spatio-temporal gait parameters from trunk accelerations during human walking
Zijlstra, W., & Hof, A. L. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00190-x · Cited by 870 · cited 1×
“It has been reported that the anterior-posterior acceleration of the trunk segment increased with walking velocity (Zijlstra and Hof, 2003), and as the current work conducted experiments at fairly low velocity (88 steps/min), the effect of any anterior-posterior acceleration may not have been apparent.”
BackgroundMeasuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647
Detection of static and dynamic activities using uniaxial accelerometers
Veltink, P. H., Bussmann, H. J., de Vries, W., Martens, W. J., & Van Lummel, R. C. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.547939 · Cited by 491 · cited 1×
“Such inertial sensors allow measurements to be made outside the laboratory environment (Veltink et al., 1996; Bouten et al., 1997; Bussmann et al., 1998; Foerster et al., 1999).”
BackgroundDetection of posture and motion by accelerometry: a validation study in ambulatory monitoring
Foerster, F., Smeja, M., & Fahrenberg, J. (1999) · Computers in Human Behavior · doi:10.1016/s0747-5632(99)00037-0 · Cited by 480 · cited 1×
“Such inertial sensors allow measurements to be made outside the laboratory environment (Veltink et al., 1996; Bouten et al., 1997; Bussmann et al., 1998; Foerster et al., 1999).”
BackgroundA practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460 · cited 1×
“A common method to estimate body segment orientation is by integrating angular velocity data measured by gyro sensors worn on body segments (Tong and Granat, 1999).”
MethodA real-time articulated human motion tracking using tri-axis inertial/magnetic sensors package
Zhu, R., & Zhou, Z. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.827825 · Cited by 390
Ambulatory Position and Orientation Tracking Fusing Magnetic and Inertial Sensing
Roetenberg, D., Slycke, P. J., & Veltink, P. H. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889184 · Cited by 334 · cited 2×
“92 for the knee F–E was consistent with the results using wearable sensors provided by Tong and Granat (1999) and Dejnabadi et al.”
MethodResultAccelerometry—A technique for the measurement of human body movements
Morris, J. R. W. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90029-8 · Cited by 325 · cited 1×
“An alternative method for measuring human motion is by placing small acceleration sensors on the body (Morris, 1973).”
Method
Cited by
Gait Analysis Using Wearable Sensors
Tao, W., Liu, T., Zheng, R., & Feng, H. (2012) · Sensors · doi:10.3390/s120202255 · Cited by 1,165
IMU-Based Joint Angle Measurement for Gait Analysis
Seel, T., Raisch, J., & Schauer, T. (2014) · Sensors · doi:10.3390/s140406891 · Cited by 867
Shull, P. B., Jirattigalachote, W., Hunt, M. A., Cutkosky, M. R., & Delp, S. L. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.03.189 · Cited by 388
Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review
Poitras, I., Dupuis, F., Bielmann, M., Campeau-Lecours, A., Mercier, C., Bouyer, L., & Roy, J.-S. (2019) · Sensors · doi:10.3390/s19071555 · Cited by 309
Tadano, S., Takeda, R., & Miyagawa, H. (2013) · Sensors · doi:10.3390/s130709321 · Cited by 171
“This method proved useful in obtaining accurate knee joint measurements and was expanded to calculating three dimensional positions of the hip, knee and ankle joint centers in a global coordinate system [13].”
BackgroundMethodSelf-citationBolink, S. A. A. N., Naisas, H., Senden, R., Essers, H., Heyligers, I. C., Meijer, K., & Grimm, B. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.11.009 · Cited by 147
“[31] ompared hip and knee joint motion during gait assessed by IMU and OCAP, with optical markers attached onto anatomical human body andmarks, and reported a mean RMSE of 8.”
BackgroundMethodBlair, S., Duthie, G., Robertson, S., Hopkins, W., & Ball, K. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.03.031 · Cited by 117
Optimization of IMU sensor placement for the measurement of lower limb joint kinematics
Niswander, W., Wang, W., & Kontson, K. (2020) · Sensors · doi:10.3390/s20215993 · Cited by 116
“Other studies have reported lower RMSE values at the same joints [39,40].”
BackgroundWearable Sensor-Based Rehabilitation Exercise Assessment for Knee Osteoarthritis
Chen, K.-H., Chen, P.-C., Liu, K.-C., & Chan, C.-T. (2015) · Sensors · doi:10.3390/s150204193 · Cited by 115
Drift Removal for Improving the Accuracy of Gait Parameters Using Wearable Sensor Systems
Takeda, R., Lisco, G., Fujisawa, T., Gastaldi, L., Tohyama, H., & Tadano, S. (2014) · Sensors · doi:10.3390/s141223230 · Cited by 84
“In this work gait analysis of five healthy volunteers was measured using a wearable sensor gait analysis system called H-Gait (Development Code, Laboratory of Biomechanical Design, Hokkaido University, Sapporo, Japan) [8,13,16].”
MethodSelf-citationCelik, Y., Stuart, S., Woo, W., Sejdic, E., & Godfrey, A. (2022) · Information Fusion · doi:10.1016/j.inffus.2021.09.016 · Cited by 83
Wearable Inertial Sensors and Their Applications
Tamura, T. (2014) · Wearable Sensors · doi:10.1016/b978-0-12-418662-0.00024-6 · Cited by 19
Ding, Z., Yang, C., Ma, J., Wei, J., & Jiang, F. (2020) · Multimedia Tools and Applications · doi:10.1007/s11042-019-07911-8 · Cited by 4
Metadata
- Authors
- Takeda, R., Tadano, S., Natorigawa, A., Todoh, M., & Yoshinari, S.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2009-11
- Volume
- 42
- Issue
- 15
- Pages
- 2486-2494
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2137677750
- Cited by
- 197
- References
- 18
- FWCI
- 5.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.