The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Characterization of the anisotropic mechanical properties of excised human skin
Open accessAbstract
The mechanical properties of skin are important for a number of applications including surgery, dermatology, impact biomechanics and forensic science. In this study, we have investigated the influence of location and orientation on the deformation characteristics of 56 samples of excised human skin. Uniaxial tensile tests were carried out at a strain rate of 0.012 s(-1) on skin from the back. Digital Image Correlation was used for 2D strain measurement and a histological examination of the dermis was also performed. The mean ultimate tensile strength (UTS) was 21.6±8.4 MPa, the mean failure strain 54%±17%, the mean initial slope 1.18±0.88 MPa, the mean elastic modulus 83.3±34.9 MPa and the mean strain energy was 3.6±1.6 MJ/m(3). A multivariate analysis of variance has shown that these mechanical properties of skin are dependent upon the orientation of the Langer lines (P<0.0001-P=0.046). The location of specimens on the back was also found to have a significant effect on the UTS (P=0.0002), the elastic modulus (P=0.001) and the strain energy (P=0.0052). The histological investigation concluded that there is a definite correlation between the orientation of the Langer lines and the preferred orientation of collagen fibres in the dermis (P<0.001). The data obtained in this study will provide essential information for those wishing to model the skin using a structural constitutive model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The tensile strength of human skin is reported to vary from 7 to 40 MPa, with an average of 21.6 ± 8.4 MPa at a strain rate of 50 mm/min [41].”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CircStat : A MATLAB Toolbox for Circular Statistics
Berens, P. (2009) · Journal of Statistical Software · doi:10.18637/jss.v031.i10 · Cited by 3,099
Hyperelastic modelling of arterial layers with distributed collagen fibre orientations
Gasser, T. C., Ogden, R. W., & Holzapfel, G. A. (2006) · Journal of The Royal Society Interface · doi:10.1098/rsif.2005.0073 · Cited by 2,411
Statistical Analysis of Circular Data.
Lange, N., & Fisher, N. I. (1995) · Journal of the American Statistical Association · doi:10.2307/2291098 · Cited by 2,146
Statistical Analysis of Circular Data
Fisher, N. I. (1993) · Cambridge University Press eBooks · doi:10.1017/cbo9780511564345 · Cited by 1,670
Mechanical properties and Young's modulus of human skin in vivo
Agache, P. G., Monneur, C., Leveque, J. L., & De Rigal, J. (1980) · Archives of Dermatological Research · doi:10.1007/bf00406415 · Cited by 741
In vivo measurements of the elastic mechanical properties of human skin by indentation tests
Pailler-Mattei, C., Bec, S., & Zahouani, H. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.06.011 · Cited by 724
Anatomy and Physiology of the Skin
Kolarsick, P. A. J., Kolarsick, M. A., & Goodwin, C. (2011) · Journal of the Dermatology Nurses' Association · doi:10.1097/jdn.0b013e3182274a98 · Cited by 578 · cited 2×
“Specimens are superimposed onto a map of the Langer lines to indicate their orientation with respect to the lines (Langer 1861).”
Viscoelastic properties of human skin and processed dermis
Silver, F. H., Freeman, J. W., & DeVore, D. (2001) · Skin Research and Technology · doi:10.1034/j.1600-0846.2001.007001018.x · Cited by 476
Biomechanical Properties of In Vivo Human Skin From Dynamic Optical Coherence Elastography
Liang, X., & Boppart, S. A. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2033464 · Cited by 470
Two-dimensional mechanical properties of rabbit skin—I. Experimental system
Lanir, Y., & Fung, Y. C. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90067-0 · Cited by 423
Cited by
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Processing of collagen based biomaterials and the resulting materials properties
Meyer, M. (2019) · BioMedical Engineering OnLine · doi:10.1186/s12938-019-0647-0 · Cited by 539
Soft network composite materials with deterministic and bio-inspired designs
Jang, K.-I., Chung, H. U., Xu, S., Lee, C. H., Luan, H., Jeong, J., Cheng, H., Kim, G.-T., Han, S. Y., Lee, J. W., et al. (2015) · Nature Communications · doi:10.1038/ncomms7566 · Cited by 533
Skin mechanical properties and modeling: A review
Joodaki, H., & Panzer, M. B. (2018) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1177/0954411918759801 · Cited by 480
On the tear resistance of skin
Yang, W., Sherman, V. R., Gludovatz, B., Schaible, E., Stewart, P., Ritchie, R. O., & Meyers, M. A. (2015) · Nature Communications · doi:10.1038/ncomms7649 · Cited by 440
Wu, H., Yang, G., Zhu, K., Liu, S., Guo, W., Jiang, Z., & Li, Z. (2021) · Advanced Science · doi:10.1002/advs.202001938 · Cited by 395
Mechanical properties of whole-body soft human tissues: a review
Singh, G., & Chanda, A. (2021) · Biomedical Materials · doi:10.1088/1748-605x/ac2b7a · Cited by 364
Bioprinting: From Tissue and Organ Development to in Vitro Models
Mota, C., Camarero-Espinosa, S., Baker, M. B., Wieringa, P., & Moroni, L. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00789 · Cited by 345
Age-dependent biomechanical properties of the skin
Pawlaczyk, M., Lelonkiewicz, M., & Wieczorowski, M. (2013) · Advances in Dermatology and Allergology · doi:10.5114/pdia.2013.38359 · Cited by 335
Mechanically and biologically skin-like elastomers for bio-integrated electronics
Chen, S., Sun, L., Zhou, X., Guo, Y., Song, J., Qian, S., Liu, Z., Guan, Q., Meade Jeffries, E., Liu, W., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-14446-2 · Cited by 311
Ma, Q., Cheng, H., Jang, K.-I., Luan, H., Hwang, K.-C., Rogers, J. A., Huang, Y., & Zhang, Y. (2016) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2016.02.012 · Cited by 309
Wearable Skin Sensors and Their Challenges: A Review of Transdermal, Optical, and Mechanical Sensors
Ahmad Tarar, A., Mohammad, U., & K. Srivastava, S. (2020) · Biosensors · doi:10.3390/bios10060056 · Cited by 119
Griffin, M. F., Leung, B. C., Premakumar, Y., Szarko, M., & Butler, P. E. (2017) · Journal of Otolaryngology - Head & Neck Surgery · doi:10.1186/s40463-017-0210-6 · Cited by 113
“9 to 150 MPa irrespective of different donor sites [19].”
BackgroundKoosha, M., Aalipour, H., Sarraf Shirazi, M. J., Jebali, A., Chi, H., Hamedi, S., Wang, N., Li, T., & Moravvej, H. (2021) · Journal of Functional Biomaterials · doi:10.3390/jfb12040061 · Cited by 92
Sander, E. A., Lynch, K. A., & Boyce, S. T. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4026290 · Cited by 62
A highly stretchable smart dressing for wound infection monitoring and treatment
Su, R., Wang, L., Han, F., Bian, S., Meng, F., Qi, W., Zhai, X., Li, H., Wu, J., Pan, X., et al. (2024) · Materials Today Bio · doi:10.1016/j.mtbio.2024.101107 · Cited by 24
Macartney, R. A., Weaver, E., Irwin, R., Wylie, M. P., Burke, G. A., & Lamprou, D. A. (2024) · Biomaterials Advances · doi:10.1016/j.bioadv.2024.213765 · Cited by 19
Thermally damaged porcine skin is not a surrogate mechanical model of human skin
Gallagher, S., Kruger, U., Josyula, K., Rahul, Gong, A., Song, A., Sweet, R., Makled, B., Parsey, C., Norfleet, J., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-08551-z · Cited by 17
Metadata
- Authors
- Ní Annaidh, A., Bruyère, K., Destrade, M., Gilchrist, M. D., & Otténio, M.
- Venue
- Journal of the Mechanical Behavior of Biomedical Materials
- Publisher
- Elsevier BV
- Published
- 2012-01
- Volume
- 5
- Issue
- 1
- Pages
- 139-148
- ISSN
- 1751-6161 (ISSN-L)
- OpenAlex
- W2146112273
- Cited by
- 763
- References
- 39
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.