The DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
Measurements of mechanical anisotropy in brain tissue and implications for transversely isotropic material models of white matter
Open accessAbstract
White matter in the brain is structurally anisotropic, consisting largely of bundles of aligned, myelin-sheathed axonal fibers. White matter is believed to be mechanically anisotropic as well. Specifically, transverse isotropy is expected locally, with the plane of isotropy normal to the local mean fiber direction. Suitable material models involve strain energy density functions that depend on the I4 and I5 pseudo-invariants of the Cauchy–Green strain tensor to account for the effects of relatively stiff fibers. The pseudo-invariant I4 is the square of the stretch ratio in the fiber direction; I5 contains contributions of shear strain in planes parallel to the fiber axis. Most, if not all, published models of white matter depend on I4 but not on I5. Here, we explore the small strain limits of these models in the context of experimental measurements that probe these dependencies. Models in which strain energy depends on I4 but not I5 can capture differences in Young’s (tensile) moduli, but will not exhibit differences in shear moduli for loading parallel and normal to the mean direction of axons. We show experimentally, using a combination of shear and asymmetric indentation tests, that white matter does exhibit such differences in both tensile and shear moduli. Indentation tests were interpreted through inverse fitting of finite element models in the limit of small strains. Results highlight that: (1) hyperelastic models of transversely isotropic tissues such as white matter should include contributions of both the I4 and I5 strain pseudo-invariants; and (2) behavior in the small strain regime can usefully guide the choice and initial parameterization of more general material models of white matter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonlinear Solid Mechanics: A Continuum Approach for Engineering
Holzapfel, G. A. (2000) · Cited by 2,700
Hyperelastic modelling of arterial layers with distributed collagen fibre orientations
Gasser, T. C., Ogden, R. W., & Holzapfel, G. A. (2006) · Journal of The Royal Society Interface · doi:10.1098/rsif.2005.0073 · Cited by 2,411
Bower, A. F. (2009) · CRC Press eBooks · doi:10.1201/9781439802489 · Cited by 1,536
Diffuse axonal injury and traumatic coma in the primate
Gennarelli, T. A., Thibault, L. E., Adams, J. H., Graham, D. I., Thompson, C. J., & Marcincin, R. P. (1982) · Annals of Neurology · doi:10.1002/ana.410120611 · Cited by 1,528
A Proposed Injury Threshold for Mild Traumatic Brain Injury
Zhang, L., Yang, K. H., & King, A. I. (2004) · Journal of Biomechanical Engineering · doi:10.1115/1.1691446 · Cited by 939
Surveillance for traumatic brain injury-related deaths--United States, 1997-2007.
Coronado, V. G., Xu, L., Basavaraju, S. V., McGuire, L. C., Wald, M. M., Faul, M. D., Guzman, B. R., & Hemphill, J. D. (2011) · PubMed · Cited by 913
Finite element implementation of incompressible, transversely isotropic hyperelasticity
Weiss, J. A., Maker, B. N., & Govindjee, S. (1996) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(96)01035-3 · Cited by 797
Regional, Directional, and Age-Dependent Properties of the Brain Undergoing Large Deformation
Prange, M. T., & Margulies, S. S. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1449907 · Cited by 635
Mechanical properties of brain tissue in tension
Miller, K., & Chinzei, K. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00234-2 · Cited by 635
Continuum Theory of the Mechanics of Fibre-Reinforced Composites
Spencer, A. (1984) · Springer eBooks · doi:10.1007/978-3-7091-4336-0 · Cited by 475
A proposed tolerance criterion for diffuse axonal injury in man
Margulies, S. S., & Thibault, L. E. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90231-o · Cited by 466
Magnetic resonance elastography of the brain
Kruse, S. A., Rose, G. H., Glaser, K. J., Manduca, A., Felmlee, J. P., Jack, C. R., & Ehman, R. L. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.08.030 · Cited by 424
In vivo brain viscoelastic properties measured by magnetic resonance elastography
Green, M. A., Bilston, L. E., & Sinkus, R. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1254 · Cited by 418
Are in vivo and in situ brain tissues mechanically similar?
Gefen, A., & Margulies, S. S. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.032 · Cited by 417
A viscoelastic study of scalp, brain, and dura
Galford, J. E., & McElhaney, J. H. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90007-2 · Cited by 347
Fifty years of brain tissue mechanical testing: From in vitro to in vivo investigations
Chatelin, S., Constantinesco, A., & Willinger, R. (2010) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.3233/bir-2010-0576 · Cited by 342
Axonal Damage in Traumatic Brain Injury
Smith, D. H., & Meaney, D. F. (2000) · The Neuroscientist · doi:10.1177/107385840000600611 · Cited by 342
Non‐invasive measurement of brain viscoelasticity using magnetic resonance elastography
Sack, I., Beierbach, B., Hamhaber, U., Klatt, D., & Braun, J. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1189 · Cited by 316
Rheological Response of Human Brain Tissue in Shear
Shuck, L. Z., & Advani, S. H. (1972) · Journal of Basic Engineering · doi:10.1115/1.3425588 · Cited by 308
Continuum Theory of the Mechanics of Fibre-Reinforced Composites
Spencer, A. J. M., & Hashin, Z. (1986) · Journal of Applied Mechanics · doi:10.1115/1.3171730 · Cited by 304
Deformation of the Human Brain Induced by Mild Acceleration
Bayly, P. V., Cohen, T. S., Leister, E. P., Ajo, D., Leuthardt, E. C., & Genin, G. M. (2005) · Journal of Neurotrauma · doi:10.1089/neu.2005.22.845 · Cited by 288
Self-citationDynamic mechanical properties of human brain tissue
Fallenstein, G. T., Hulce, V. D., & Melvin, J. W. (1969) · Journal of Biomechanics · doi:10.1016/0021-9290(69)90079-7 · Cited by 288
Mechanical properties of brain tissue by indentation: Interregional variation
van Dommelen, J. A. W., van der Sande, T. P. J., Hrapko, M., & Peters, G. W. M. (2010) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2009.09.001 · Cited by 283
Mechanical response of fiber-reinforced incompressible non-linearly elastic solids
Merodio, J., & Ogden, R. W. (2005) · International Journal of Non-Linear Mechanics · doi:10.1016/j.ijnonlinmec.2004.05.003 · Cited by 266
Anisotropic constitutive equations and experimental tensile behavior of brain tissue
Velardi, F., Fraternali, F., & Angelillo, M. (2006) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-005-0007-9 · Cited by 258
McAllister, T. W., Ford, J. C., Ji, S., Beckwith, J. G., Flashman, L. A., Paulsen, K., & Greenwald, R. M. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0402-6 · Cited by 251
Christ, A. F., Franze, K., Gautier, H., Moshayedi, P., Fawcett, J., Franklin, R. J. M., Karadottir, R. T., & Guck, J. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.07.002 · Cited by 243
Material characterization of the brainstem from oscillatory shear tests
Arbogast, K. B., & Margulies, S. S. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00068-2 · Cited by 225
Measurement of the hyperelastic properties of ex vivo brain tissue slices
Kaster, T., Sack, I., & Samani, A. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.01.019 · Cited by 223
Rheological properties of the tissues of the central nervous system: A review
Cheng, S., Clarke, E. C., & Bilston, L. E. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.06.003 · Cited by 212
Morrison, B., Cater, H. L., Wang, C. C.-B., Thomas, F. C., Hung, C. T., Ateshian, G. A., & Sundstrom, L. E. (2003) · SAE Technical Paper Series · doi:10.4271/2003-22-0006 · Cited by 210
On planar biaxial tests for anisotropic nonlinearly elastic solids. A continuum mechanical framework
Holzapfel, G. A., & Ogden, R. W. (2009) · Mathematics and Mechanics of Solids · doi:10.1177/1081286507084411 · Cited by 206
LaPlaca, M. C., Cullen, D. K., McLoughlin, J. J., & Cargill, R. S. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.032 · Cited by 205
Brody, D. L., Mac Donald, C., Kessens, C. C., Yuede, C., Parsadanian, M., Spinner, M., Kim, E., Schwetye, K. E., Holtzman, D. M., & Bayly, P. V. (2007) · Journal of Neurotrauma · doi:10.1089/neu.2006.0011 · Cited by 198
Self-citationDeformation of the human brain induced by mild angular head acceleration
Sabet, A. A., Christoforou, E., Zatlin, B., Genin, G. M., & Bayly, P. V. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.016 · Cited by 198
Self-citationThe Influence of Test Conditions on Characterization of the Mechanical Properties of Brain Tissue
Hrapko, M., van Dommelen, J. A. W., Peters, G. W. M., & Wismans, J. S. H. M. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2907746 · Cited by 184
Shear linear behavior of brain tissue over a large frequency range
Nicolle, S., Lounis, M., Willinger, R., & Palierne, J. ‐. (2005) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.1177/0006355x2005042003003 · Cited by 176
An axonal strain injury criterion for traumatic brain injury
Wright, R. M., & Ramesh, K. T. (2012) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-011-0307-1 · Cited by 169
Garo, A., Hrapko, M., van Dommelen, J. A. W., & Peters, G. G. (2007) · Biorheology · doi:10.1177/0006355x2007044001003 · Cited by 144
Ning, X., Zhu, Q., Lanir, Y., & Margulies, S. S. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2354208 · Cited by 141
Defining Brain Mechanical Properties: Effects of Region, Direction, and Species
Prange, M. T., & Meaney, D. F. (2000) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2000-01-sc15 · Cited by 133
In vivo waveguide elastography of white matter tracts in the human brain
Romano, A. J., Scheel, M., Hirsch, S., Braun, J., & Sack, I. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24141 · Cited by 130
Relative brain displacement and deformation during constrained mild frontal head impact
Feng, Y., Abney, T. M., Okamoto, R. J., Pless, R. B., Genin, G. M., & Bayly, P. V. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0210 · Cited by 129
Self-citationDynamic mechanical response of brain tissue in indentation in vivo, in situ and in vitro
Prevost, T. P., Jin, G., de Moya, M. A., Alam, H. B., Suresh, S., & Socrate, S. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.06.032 · Cited by 124
Frequency-dependent viscoelastic parameters of mouse brain tissue estimated by MR elastography
Clayton, E. H., Garbow, J. R., & Bayly, P. V. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/8/005 · Cited by 122
Self-citationTransmission, attenuation and reflection of shear waves in the human brain
Clayton, E. H., Genin, G. M., & Bayly, P. V. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2012.0325 · Cited by 113
Self-citationViscoelastic properties of human cerebellum using magnetic resonance elastography
Zhang, J. H., Green, M. A., Sinkus, R., & Bilston, L. E. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.04.034 · Cited by 112
Okamoto, R. J., Clayton, E. H., & Bayly, P. V. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/19/014 · Cited by 111
Self-citationMeaney, D. F. (2003) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-002-0020-1 · Cited by 107
In vivo imaging of rapid deformation and strain in an animal model of traumatic brain injury
Bayly, P. V., Black, E. E., Pedersen, R. C., Leister, E. P., & Genin, G. M. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.02.014 · Cited by 104
Self-citationA Detailed Viscoelastic Characterization of the P17 and Adult Rat Brain
Elkin, B. S., Ilankovan, A., & Morrison, B. (2011) · Journal of Neurotrauma · doi:10.1089/neu.2010.1604 · Cited by 99
Qin, E. C., Sinkus, R., Geng, G., Cheng, S., Green, M., Rae, C. D., & Bilston, L. E. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23797 · Cited by 99
Dynamic, Regional Mechanical Properties of the Porcine Brain: Indentation in the Coronal Plane
Elkin, B. S., Ilankova, A., & Morrison, B. (2011) · Journal of Biomechanical Engineering · doi:10.1115/1.4004494 · Cited by 92
An anisotropic viscous hyperelastic constitutive law for brain material finite-element modeling
Chatelin, S., Deck, C., & Willinger, R. (2012) · Journal of Biorheology · doi:10.1007/s12573-012-0055-6 · Cited by 88
Wide-range dynamic magnetic resonance elastography
Riek, K., Klatt, D., Nuzha, H., Mueller, S. G., Neumann, U. P., Sack, I., & Braun, J. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.12.031 · Cited by 76
Presynaptic Inhibition of Corticothalamic Feedback by Metabotropic Glutamate Receptors
Alexander, G. M., & Godwin, D. W. (2005) · Journal of Neurophysiology · doi:10.1152/jn.01198.2004 · Cited by 60
Namani, R., Feng, Y., Okamoto, R. J., Jesuraj, N. J., Sakiyama‐Elbert, S. E., Genin, G. M., & Bayly, P. V. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4006848 · Cited by 53
Self-citationA tissue-level anisotropic criterion for brain injury based on microstructural axonal deformation
Cloots, R. J. H., van Dommelen, J. A. W., & Geers, M. G. D. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.09.012 · Cited by 44
Time-harmonic magnetic resonance elastography of the normal feline brain
Pattison, A. J., Lollis, S. S., Perriñez, P. R., Perreard, I. M., McGarry, M., Weaver, J. B., & Paulsen, K. D. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.06.008 · Cited by 36
Principal Component Analysis of Dynamic Relative Displacement Fields Estimated from MR Images
Abney, T. M., Feng, Y., Pless, R. B., Okamoto, R. J., Genin, G. M., & Bayly, P. V. (2011) · PLoS ONE · doi:10.1371/journal.pone.0022063 · Cited by 11
Self-citation
Cited by
Mechanical characterization of human brain tissue
Budday, S., Sommer, G., Birkl, C., Langkammer, C., Haybaeck, J., Kohnert, J., Bauer, M., Paulsen, F., Steinmann, P., Kuhl, E., et al. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.10.036 · Cited by 656
Fifty Shades of Brain: A Review on the Mechanical Testing and Modeling of Brain Tissue
Budday, S., Ovaert, T. C., Holzapfel, G. A., Steinmann, P., & Kuhl, E. (2020) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-019-09352-w · Cited by 469
Mechanics of the brain: perspectives, challenges, and opportunities
Goriely, A., Geers, M. G. D., Holzapfel, G. A., Jayamohan, J., Jérusalem, A., Sivaloganathan, S., Squier, W., van Dommelen, J. A. W., Waters, S., & Kuhl, E. (2015) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-015-0662-4 · Cited by 371
Mechanical properties of whole-body soft human tissues: a review
Singh, G., & Chanda, A. (2021) · Biomedical Materials · doi:10.1088/1748-605x/ac2b7a · Cited by 364
Hyperelastic Energy Densities for Soft Biological Tissues: A Review
Chagnon, G., Rebouah, M., & Favier, D. (2015) · Journal of Elasticity · doi:10.1007/s10659-014-9508-z · Cited by 292
Metadata
- Authors
- Feng, Y., Okamoto, R. J., Namani, R., Genin, G. M., & Bayly, P. V.
- Venue
- Journal of the Mechanical Behavior of Biomedical Materials
- Publisher
- Elsevier BV
- Published
- 2013-07
- Volume
- 23
- Pages
- 117-132
- ISSN
- 1751-6161 (ISSN-L)
- OpenAlex
- W2083627232
- Cited by
- 316
- References
- 60
- FWCI
- 8.68
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.