The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Review of signal distortion through metal microelectrode recording circuits and filters
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gamma (40-100 Hz) oscillation in the hippocampus of the behaving rat
Bragin, A., Jando, G., Nadasdy, Z., Hetke, J., Wise, K., & Buzsaki, G. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-01-00047.1995 · Cited by 1,527
Differential attention-dependent response modulation across cell classes in macaque visual area V4
Mitchell, J. F., Sundberg, K. A., & Reynolds, J. H. (2007) · Neuron · doi:10.1016/j.neuron.2007.06.018 · Cited by 665
Cited by
Neurophysiological and Computational Principles of Cortical Rhythms in Cognition
Wang, X.-J. (2010) · Physiological Reviews · doi:10.1152/physrev.00035.2008 · Cited by 1,939
“This results in frequency-dependent phase shifts and amplitude attenuation when the electrode impedance is not negligible relative to the effective input impedance of the head-stage amplifier (717).”
Backgroundvan Kerkoerle, T., Self, M. W., Dagnino, B., Gariel-Mathis, M.-A., Poort, J., van der Togt, C., & Roelfsema, P. R. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1402773111 · Cited by 918
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
“The “metal”-part of the model is an equivalent circuit of the microelectrode modified from Robinson (1968), Franks et al. (2005), Nelson et al. (2008), Hierlemann et al. (2011).”
InfluentialHuman memory strength is predicted by theta-frequency phase-locking of single neurons
Rutishauser, U., Ross, I. B., Mamelak, A. N., & Schuman, E. M. (2010) · Nature · doi:10.1038/nature08860 · Cited by 622
Zhang, A., & Lieber, C. M. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00608 · Cited by 621
Simeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468
Using a Common Average Reference to Improve Cortical Neuron Recordings From Microelectrode Arrays
Ludwig, K. A., Miriani, R. M., Langhals, N. B., Joseph, M. D., Anderson, D. J., & Kipke, D. R. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90989.2008 · Cited by 420
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
A MEMS-based flexible multichannel ECoG-electrode array
Rubehn, B., Bosman, C., Oostenveld, R., Fries, P., & Stieglitz, T. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/036003 · Cited by 387
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
Local Field Potentials: Myths and Misunderstandings
Herreras, O. (2016) · Frontiers in Neural Circuits · doi:10.3389/fncir.2016.00101 · Cited by 330
Boehler, C., Carli, S., Fadiga, L., Stieglitz, T., & Asplund, M. (2020) · Nature Protocols · doi:10.1038/s41596-020-0389-2 · Cited by 308
Abidian, M. R., Ludwig, K. A., Marzullo, T. C., Martin, D. C., & Kipke, D. R. (2009) · Advanced Materials · doi:10.1002/adma.200900887 · Cited by 255
Multiplexed, High Density Electrophysiology with Nanofabricated Neural Probes
Du, J., Blanche, T. J., Harrison, R. R., Lester, H. A., & Masmanidis, S. C. (2011) · PLoS ONE · doi:10.1371/journal.pone.0026204 · Cited by 231
“In order to accurately interpret LFP phase information, we first confirmed that the ASIC’s analog high-pass filter and any electrode impedance-dependent distortions in the phase and amplitude of electrophysiological signals were minimal [43].”
BackgroundHagen, E., Næss, S., Ness, T. V., & Einevoll, G. T. (2018) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2018.00092 · Cited by 129
Lithium Ameliorates Nucleus Accumbens Phase-Signaling Dysfunction in a Genetic Mouse Model of Mania
Dzirasa, K., Coque, L., Sidor, M. M., Kumar, S., Dancy, E. A., Takahashi, J. S., McClung, C. A., & Nicolelis, M. A. L. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.4289-10.2010 · Cited by 85
A Compact, Low Input Capacitance Neural Recording Amplifier
Ng, K. A., & Xu, Y. P. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2280066 · Cited by 81
Perspectives on electrical neural recording: a revisit to the fundamental concepts
Guo, L. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab702f · Cited by 28
Metadata
- Authors
- Nelson, M. J., Pouget, P., Nilsen, E. A., Patten, C. D., & Schall, J. D.
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2008-03
- Volume
- 169
- Issue
- 1
- Pages
- 141-157
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2149924097
- Cited by
- 167
- References
- 2
- FWCI
- 3.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.