Two-photon imaging of chronically implanted neural electrodes: Sealing methods and new insights
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Background Two-photon microscopy has enabled the visualization of dynamic tissue changes to injury and disease in vivo. While this technique has provided powerful new information, in vivo two-photon chronic imaging around tethered cortical implants, such as microelectrodes or neural probes, present unique challenges. New Method A number of strategies are described to prepare a cranial window to longitudinally observe the impact of neural probes on brain tissue and vasculature for up to 3 months. Results It was found that silastic sealants limit cell infiltration into the craniotomy, thereby limiting light scattering and preserving window clarity over time. In contrast, low concentration hydrogel sealants failed to prevent cell infiltration and their use at high concentration displaced brain tissue and disrupted probe performance. Comparison with Existing Method(s) The use of silastic sealants allows for a suitable imaging window for long term chronic experiments and revealed new insights regarding the dynamic leukocyte response around implants and the nature of chronic BBB leakage in the sub-dural space. Conclusion The presented method provides a valuable tool for evaluating the chronic inflammatory response and the performance of emerging implantable neural technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogels as extracellular matrix mimics for 3D cell culture
Tibbitt, M. W., & Anseth, K. S. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22361 · Cited by 2,727 · cited 1×
“Low concentration hydrogels such as alginate do not swell but can form scaffolds for cell infiltration and growth, as often employed in 3D cell cultures (Tibbitt and Anseth, 2009).”
BackgroundReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719 · cited 1×
“More recently, they have demonstrated significant promise in restoring functional control to patients with tetraplegia by extracting the intent of the subject via detection of firing rates of small populations of neurons (Collinger et al., 2012; Hochberg et al., 2012).”
BackgroundHigh-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848 · cited 1×
“More recently, they have demonstrated significant promise in restoring functional control to patients with tetraplegia by extracting the intent of the subject via detection of firing rates of small populations of neurons (Collinger et al., 2012; Hochberg et al., 2012).”
BackgroundWake, H., Moorhouse, A. J., Jinno, S., Kohsaka, S., & Nabekura, J. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.4363-08.2009 · Cited by 1,619 · cited 1×
“…used as a research tool to understand temporal dynamics of injury and disease (Bell et al., 2010; Davalos et al., 2005; Kozai et al., 2012b; Masamoto et al., 2012; Wake et al., 2009) For example, in vivo TPM has been previously used to map the BBB prior to implant insertion (Kozai et al., 2010).”
MethodIn vivo three-photon microscopy of subcortical structures within an intact mouse brain
Horton, N. G., Wang, K., Kobat, D., Clark, C. G., Wise, F. W., Schaffer, C. B., & Xu, C. (2013) · Nature Photonics · doi:10.1038/nphoton.2012.336 · Cited by 1,505 · cited 2×
“…such as regenerative amplification multiphoton microscopy (Mittmann et al., 2011), adaptive optics (Ji et al., 2010), multiphoton microscopy (Horton et al., 2013), liquid light guide technology, and a greater library of long wavelength proteins and dyes (red, far red, and infra-red)…”
BackgroundBell, R. D., Winkler, E. A., Sagare, A. P., Singh, I., LaRue, B., Deane, R., & Zlokovic, B. V. (2010) · Neuron · doi:10.1016/j.neuron.2010.09.043 · Cited by 1,448 · cited 2×
“TPM has been successfully used as a research tool to understand temporal dynamics of injury and disease (Bell et al., 2010; Davalos et al., 2005; Kozai et al., 2012b; Masamoto et al., 2012; Wake et al., 2009) For example, in vivo TPM has been previously used to map the BBB prior to implant…”
MethodRepair of bone defects using synthetic mimetics of collagenous extracellular matrices
Lutolf, M. P., Weber, F. E., Schmoekel, H. G., Schense, J. C., Kohler, T., Müller, R., & Hubbell, J. A. (2003) · Nature Biotechnology · doi:10.1038/nbt818 · Cited by 850 · cited 1×
“This has also been reported in studies using silicone elastomer as a sealant, but not with PEG-based sealants, which encourage bone regrowth into large calvarial defects (Lutolf et al., 2003; Spitler and Gothard, 2008; Terella et al., 2010).”
ResultKozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721 · cited 3×
“TPM has been successfully used as a research tool to understand temporal dynamics of injury and disease (Bell et al., 2010; Davalos et al., 2005; Kozai et al., 2012b; Masamoto et al., 2012; Wake et al., 2009) For example, in vivo TPM has been previously used to map the BBB prior to implant…”
BackgroundMethodSelf-citationLutolf, M. P., & Hubbell, J. A. (2003) · Biomacromolecules · doi:10.1021/bm025744e · Cited by 679
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622 · cited 8×
“Unlike material failure modes of implantable electrodes(Kozai et al., 2015b; Prasad et al., 2012; Stensaas and Stensaas, 1978), the mechanism(s) behind the progression of the tissue response and the large variability of observed outcomes are poorly understood (Kozai et al., 2015d).”
BackgroundInfluentialSelf-citationFailure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600
Emergence of a stable cortical map for neuroprosthetic control
Ganguly, K., & Carmena, J. M. (2009) · PLoS Biology · doi:10.1371/journal.pbio.1000153 · Cited by 578 · cited 1×
“…research tools that allow investigators to link low level neural circuits to behavior, decision making, memory, learning, and the progression of neurological injury and disease (Gage et al., 2010; Ganguly and Carmena, 2009; Guitchounts et al., 2013; Kozai et al., 2015c; Stoetzner et al., 2010).”
BackgroundAnderson, J. M. (2000) · Current Opinion in Hematology · doi:10.1097/00062752-200001000-00008 · Cited by 386 · cited 1×
“It is believed that the fusion of macrophages is done in attempt to degrade large, non-phagocytosable materials (Anderson, 2000).”
BackgroundPrasad, A., Xue, Q.-S., Sankar, V., Nishida, T., Shaw, G., Streit, W. J., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056015 · Cited by 298
A carbon-fiber electrode array for long-term neural recording
Guitchounts, G., Markowitz, J. E., Liberti, W. A., & Gardner, T. J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/046016 · Cited by 224 · cited 2×
“Introduction Implantable intracortical electrodes are powerful neuroscience research tools that allow investigators to link low level neural circuits to behavior, decision making, memory, learning, and the progression of neurological injury and disease (Gage et al., 2010; Ganguly and Carmena, 2009; Guitchounts et al.,…”
BackgroundKozai, T. D. Y., Vazquez, A. L., Weaver, C. L., Kim, S.-G., & Cui, X. T. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/066001 · Cited by 215
Self-citationKozai, T. D. Y., Gugel, Z., Li, X., Gilgunn, P. J., Khilwani, R., Ozdoganlar, O. B., Fedder, G. K., Weber, D. J., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.07.039 · Cited by 193 · cited 8×
“…is hypothesized to be due to the combination of the inflammatory response and material failure over time following implantation (Barrese et al., 2013; Kozai et al., 2015b; Kozai et al., 2015d; Kozai et al., 2014c; Kozai et al., 2010; Prasad et al., 2012) (see (Kozai et al., 2015d) for Review).”
BackgroundResultInfluentialSelf-citationAbiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants
Prasad, A., Xue, Q.-S., Dieme, R., Sankar, V., Mayrand, R. C., Nishida, T., Streit, W. J., & Sanchez, J. C. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00002 · Cited by 178 · cited 3×
“…its associated loss of insulation dielectric properties and ionic contamination (Escamilla-Mackert et al., 2009; Gilgunn et al., 2013; Kim et al., 2014; Kozai et al., 2014a; Kozai et al., 2015a; Kozai et al., 2015b; Prasad et al., 2014; Prasad et al., 2012; Sankar et al., 2014; Ware et al., 2014).”
BackgroundResultAzemi, E., Lagenaur, C. F., & Cui, X. T. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.09.033 · Cited by 164 · cited 1×
“With this established method, it will be possible study the long term dynamic effects and side-effects of different intervention strategies such as biological camouflage coatings and controlled anti-inflammatory drug release (Azemi et al., 2011; Luo et al., 2011).”
MethodSelf-citationKozai, T. D. Y., Li, X., Bodily, L. M., Caparosa, E. M., Zenonos, G. A., Carlisle, D. L., Friedlander, R. M., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.08.006 · Cited by 136
Self-citationPotter, K. A., Buck, A. C., Self, W. K., Callanan, M. E., Sunil, S., & Capadona, J. R. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.05.035 · Cited by 129
Cited by
Glial responses to implanted electrodes in the brain
Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0154-1 · Cited by 642
“In turn, inflammation leads to the recruitment of blood-borne monocytes and neutrophils through the intact BBB, and to the formation of multinucleated giant cells 34 .”
Self-citationUltraflexible nanoelectronic probes form reliable, glial scar–free neural integration
Luan, L., Wei, X., Zhao, Z., Siegel, J. J., Potnis, O., Tuppen, C. A., Lin, S., Kazmi, S., Fowler, R. A., Holloway, S., et al. (2017) · Science Advances · doi:10.1126/sciadv.1601966 · Cited by 612
Ultrasoft microwire neural electrodes improve chronic tissue integration
Du, Z. J., Kolarcik, C. L., Kozai, T. D. Y., Luebben, S. D., Sapp, S. A., Zheng, X. S., Nabity, J. A., & Cui, X. T. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.02.010 · Cited by 209
Self-citationRecent advances in neural electrode–tissue interfaces
Woeppel, K., Yang, Q., & Cui, X. T. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.09.003 · Cited by 99
“Two-photon microscopy (TPM) has been used to visualize vascular damage and remodeling, microglial polarization and migration [48, 49], or shape and activity of the neurons around electrode devices [20, 50] before and after electrode array insertion and over extended periods of time.”
Self-citationCody, P. A., Eles, J. R., Lagenaur, C. F., Kozai, T. D. Y., & Cui, X. T. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.01.025 · Cited by 87
Self-citation
Metadata
- Authors
- Kozai, T. D. Y., Eles, J. R., Vazquez, A. L., & Cui, X. T.
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2016-01
- Volume
- 258
- Pages
- 46-55
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2174424141
- Cited by
- 91
- References
- 23
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.