Development of a multi-parametric model predictive control algorithm for insulin delivery in type 1 diabetes mellitus using clinical parameters
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
A multi-parametric model predictive control (mpMPC) algorithm for subcutaneous insulin delivery for individuals with type 1 diabetes mellitus (T1DM) that is computationally efficient, robust to variations in insulin sensitivity, and involves minimal burden for the user is proposed. System identification was achieved through impulse response tests feasible for ambulatory conditions on the UVa/Padova simulator adult subjects with T1DM. An alternative means of system identification using readily available clinical parameters was also investigated. A safety constraint was included explicitly in the algorithm formulation using clinical parameters typical of those available to an attending physician. Closed-loop simulations were carried out with daily consumption of 200 g carbohydrate. Controller robustness was assessed by subject/model mismatch scenarios addressing daily, simultaneous variation in insulin sensitivity and meal size with the addition of Gaussian white noise with a standard deviation of 10%. A second-order-plus-time-delay transfer function model fit the validation data with a mean (coefficient of variation) root-mean-square-error (RMSE) of 26 mg/dL (19%) for a 3 h prediction horizon. The resulting control law maintained a low risk Low Blood Glucose Index without any information about carbohydrate consumption for 90% of the subjects. Low-order linear models with clinically meaningful parameters thus provided sufficient information for a model predictive control algorithm to control glycemia. The use of clinical knowledge as a safety constraint can reduce hypoglycemic events, and this same knowledge can further improve glycemic control when used explicitly as the controller model. The resulting mpMPC algorithm was sufficiently compact to be implemented on a simple electronic device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Diabetes Control and Complications Trial Research Group (1995) · Diabetes · doi:10.2337/diab.44.8.968 · Cited by 1,301
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
Meal Simulation Model of the Glucose-Insulin System
Dalla Man, C., Rizza, R. A., & Cobelli, C. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.893506 · Cited by 955
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
Franco, O. H., Steyerberg, E. W., Hu, F. B., Mackenbach, J., & Nusselder, W. (2007) · Archives of Internal Medicine · doi:10.1001/archinte.167.11.1145 · Cited by 400
Effect of intensive insulin therapy on glycemic thresholds for counterregulatory hormone release.
Amiel, S. A., Sherwin, R. S., Simonson, D. C., & Tamborlane, W. V. (1988) · Diabetes · doi:10.2337/diab.37.7.901 · Cited by 393
Partitioning glucose distribution/transport, disposal, and endogenous production during IVGTT
Hovorka, R., Shojaee-Moradie, F., Carroll, P. V., Chassin, L. J., Gowrie, I. J., Jackson, N. C., Tudor, R. S., Umpleby, A. M., & Jones, R. H. (2002) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00304.2001 · Cited by 393
Model Predictive Control of Type 1 Diabetes: An in Silico Trial
Magni, L., Raimondo, D. M., Bossi, L., Dalla Man, C., De Nicolao, G., Kovatchev, B., & Cobelli, C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100603 · Cited by 317
Variability of Insulin Absorption and Insulin Action
Heinemann, L. (2002) · Diabetes Technology & Therapeutics · doi:10.1089/152091502320798312 · Cited by 267
Preventing hypoglycaemia: what is the appropriate glucose alert value?
Cryer, P. E. (2009) · Diabetologia · doi:10.1007/s00125-008-1205-7 · Cited by 77
Research works printed but not linked: 44
- Diabetes Control and Complications Trials Research Group, 1993, The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus, N. Engl. J. Med., 329, 977, 10.1056/NEJM199309303291401 · DOI · Paper page
- Bequette, 2005, A critical assessment of algorithms and challenges in the development of a closed-loop artificial pancreas, Diabetes Technol. Ther., 7, 28, 10.1089/dia.2005.7.28 · DOI · Paper page
- Renard, 2008, Insulin delivery route for the artificial pancreas: subcutaneous, intraperitoneal, or intravenous? pros and cons, J. Diabetes Sci. Technol., 2, 735, 10.1177/193229680800200429 · DOI · Paper page
- Renard, 2010, Closed-loop insulin delivery using a subcutaneous glucose sensor and intraperitoneal insulin delivery: feasibility study testing a new model for the artificial pancreas, Diabetes Care, 33, 121, 10.2337/dc09-1080 · DOI · Paper page
- Hovorka, 2006, Continuous glucose monitoring and closed-loop systems, Diabet. Med., 23, 1, 10.1111/j.1464-5491.2005.01672.x · DOI · Paper page
- Parker, 2001, The intravenous route to blood glucose control, IEEE Eng. Med. Biol., 20, 65, 10.1109/51.897829 · DOI · Paper page
- Ellingsen, 2009, Safety constraints in an artificial pancreatic β cell: an implementation of model predictive control with insulin on board, J. Diabetes Sci. Technol., 3, 536, 10.1177/193229680900300319 · DOI · Paper page
- Parker, 1999, A model-based algorithm for blood glucose control in type I diabetic patients, IEEE Trans. Biomed. Eng., 46, 148, 10.1109/10.740877 · DOI · Paper page
- Hovorka, 2010, Manual closed-loop insulin delivery in children and adolescents with type 1 diabetes: a phase 2 randomised crossover trial, Lancet, 375, 743, 10.1016/S0140-6736(09)61998-X · DOI · Paper page
- Tatò, 1991, Circadian variation of basal and postprandial insulin sensitivity in healthy individuals and patients with type-1 diabetes, Diabetes Res., 17, 13
- Allen, 1992, Insulin sensitivity after phototherapy for seasonal affective disorder, Lancet, 339, 1065, 10.1016/0140-6736(92)90594-S · DOI
- Hopkins, 2004, Exercise-induced and other daytime hypoglycemic events in patients with diabetes: prevention and treatment, Diabetes Res. Clin. Pract., 65, S35, 10.1016/j.diabres.2004.07.009 · DOI
- Scheiner, 2005, Characteristics of basal insulin requirements by age and gender in type-1 diabetes patients using insulin pump therapy, Diabetes Res. Clin. Pract., 69, 14, 10.1016/j.diabres.2004.11.005 · DOI
- Dalla Man, 2006, A system model of oral glucose absorption: validation on gold standard data, IEEE Trans. Biomed. Eng., 53, 2472, 10.1109/TBME.2006.883792 · DOI · Paper page
- Wilinska, 2005, Insulin kinetics in type-1 diabetes: continuous and bolus delivery of rapid acting insulin, IEEE Trans. Biomed. Eng., 52, 3, 10.1109/TBME.2004.839639 · DOI · Paper page
- Oruklu, 2009, Estimation of future glucose concentrations with subject-specific recursive linear models, Diabetes Technol. Ther., 11, 243, 10.1089/dia.2008.0065 · DOI · Paper page
- Finan, 2007, Practical issues in the identification of empirical models from simulated type 1 diabetes data, Diabetes Technol. Ther., 9, 438, 10.1089/dia.2007.0202 · DOI
- Finan, 2009, Effect of input excitation on the quality of empirical dynamic models for type 1 diabetes, AIChE J., 55, 1135, 10.1002/aic.11699 · DOI
- Percival, 2010, Modeling the effects of subcutaneous insulin administration and carbohydrate consumption on blood glucose, J. Diabetes Sci. Technol., 4, 1214, 10.1177/193229681000400522 · DOI · Paper page
- Zisser, 2005, Run-to-run control of meal-related insulin dosing, Diabetes Technol. Ther., 7, 48, 10.1089/dia.2005.7.48 · DOI
- Bemporad, 2002, The explicit linear quadratic regulator for constrained systems, Automatica, 38, 3, 10.1016/S0005-1098(01)00174-1 · DOI · Paper page
- Dua, 2005, Modelling and control of drug delivery systems, Comput. Chem. Eng., 29, 2290, 10.1016/j.compchemeng.2005.05.014 · DOI
- Dua, 2006, Model-based blood glucose control for type 1 diabetes via parametric programming, IEEE Trans. Biomed. Eng., 53, 1478, 10.1109/TBME.2006.878075 · DOI · Paper page
- Cobelli, 1983, Evaluation of portal/peripheral route and of algorithms for insulin delivery in the closed-loop control of glucose in diabetes—a modeling study, IEEE Trans. Biomed. Eng., 30, 93, 10.1109/TBME.1983.325203 · DOI · Paper page
- Vicini, 1997, Estimation of endogenous glucose production after a glucose perturbation by nonparametric stochastic deconvolution, Comput. Methods Programs Biomed., 52, 147, 10.1016/S0169-2607(96)01784-1 · DOI
- Percival, 2009, Practical approach to design and implementation of a control algorithm in an artificial pancreatic beta cell, Ind. Eng. Chem. Res., 48, 6059, 10.1021/ie801432u · DOI
- Percival, 2009, Am. Diabetes Assoc. 69th Scientific Sessions
- Kovatchev, 1998, Assessment of risk for severe hypoglycemia among adults with IDDM: validation of the low blood glucose index, Diabetes Care, 21, 1870, 10.2337/diacare.21.11.1870 · DOI · Paper page
- Marchetti, 2008, A feedforward-feedback glucose control strategy for type 1 diabetes mellitus, J. Process Control, 18, 149, 10.1016/j.jprocont.2007.07.008 · DOI
- Grancharova, 2004, Explicit model predictive control of gas-liquid separation plant via orthogonal search tree partitioning, Comput. Chem. Eng., 28, 2481, 10.1016/j.compchemeng.2004.06.010 · doi:10.1016/j.compchemeng.2004.06.010
- Kvasnica, 2004, Multi-parametric toolbox (MPT), Hybrid Syst.: Comput. Control, 2993, 448, 10.1007/978-3-540-24743-2_30 · DOI
- Löfberg, 2004, YALMIP: a toolbox for modeling and optimization in MATLAB, IEEE Int. Symp. Comp. Aided Contr. Syst. Des., 1, 284
- Bantle, 1988, The dietary treatment of diabetes mellitus, Med. Clin. North Am., 72, 1285, 10.1016/S0025-7125(16)30707-6 · DOI
- Cameron, 2008, Statistical hypoglycemia prediction, J. Diabetes Sci. Technol., 2, 612, 10.1177/193229680800200412 · DOI · Paper page
- Buckingham, 2009, Preventing hypoglycemia using predictive alarm algorithms and insulin pump suspension, Diabetes Technol. Ther., 11, 93, 10.1089/dia.2008.0032 · DOI · Paper page
- Dassau, 2010, Realtime hypoglycemia prediction suite using continuous glucose monitoring (CGM), a safety net for the artificial pancreas, Diabetes Care, 33, 1249, 10.2337/dc09-1487 · DOI · Paper page
- Finan, 2010, Automatic detection of stress states in type 1 diabetes subjects in ambulatory conditions, Ind. Eng. Chem. Res., 49, 7843, 10.1021/ie901891c · DOI
- Palerm, 2008, A run-to-run control strategy to adjust basal insulin infusion rates in type 1 diabetes, J. Process Control, 18, 258, 10.1016/j.jprocont.2007.07.010 · DOI
- Wang, 2010, Closed-loop control of artificial pancreatic β-cell in type 1 diabetes mellitus using model predictive iterative learning control, IEEE Trans. Biomed. Eng., 57, 211, 10.1109/TBME.2009.2024409 · DOI · Paper page
- Magni, 2009, Run-to-run tuning of model predictive control for type 1 diabetes subjects: in silico trial, J. Diabetes Sci. Technol., 3, 1091, 10.1177/193229680900300512 · DOI · Paper page
- L. Jovanovič, Insulin therapy and algorithms for treating type 1 diabetes mellitus, in: Optimizing insulin therapy in patients with diabetes, CME Activity jointly sponsored by Washington Hospital Center and MedStar Research Institute, 2002, pp. 13–19.
- Wansink, 2006, Meal size, not body size, explains errors in estimating the calorie content of meals, Ann. Intern. Med., 145, 326, 10.7326/0003-4819-145-5-200609050-00005 · DOI · Paper page
- Kovatchev, 2002, Methods for quantifying self-monitoring blood glucose profiles exemplified by an examination of blood glucose patterns in patients with type 1 and type 2 diabetes, Diabetes Technol. Ther., 4, 295, 10.1089/152091502760098438 · DOI · Paper page
- Chassin, 2005, Grading system to assess clinical performance of closed-loop glucose control, Diabetes Technol. Ther., 7, 72, 10.1089/dia.2005.7.72 · DOI
Cited by
Model Predictive Control — Status and Challenges
XI, Y.-G., LI, D.-W., & LIN, S. (2013) · Acta Automatica Sinica · doi:10.1016/s1874-1029(13)60024-5 · Cited by 291
A review of personalized blood glucose prediction strategies for T1DM patients
Oviedo, S., Vehí, J., Calm, R., & Armengol, J. (2017) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2833 · Cited by 279
Resalat, N., El Youssef, J., Tyler, N., Castle, J., & Jacobs, P. G. (2019) · PLOS ONE · doi:10.1371/journal.pone.0217301 · Cited by 78
Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility
Cobelli, C., & Kovatchev, B. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231195081 · Cited by 46
Metadata
- Authors
- Percival, M. W., Wang, Y., Grosman, B., Dassau, E., Zisser, H., Jovanovič, L., & Doyle, F. J.
- Venue
- Journal of Process Control
- Publisher
- Elsevier BV
- Published
- 2011-03
- Volume
- 21
- Issue
- 3
- Pages
- 391-404
- ISSN
- 0959-1524 (ISSN-L)
- OpenAlex
- W1973409145
- Cited by
- 75
- References
- 10
- FWCI
- 5.28
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.