Microwave Tumor Ablation: Mechanism of Action, Clinical Results, and Devices
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Microwave ablation uses dielectric hysteresis to produce direct volume heating of tissue. Microwaves are capable of propagating through many tissue types, even those with high impedance such as lung or bone, with less susceptibility to "heat-sink" effects along vessels. Microwaves are highly conducive to the use of multiple applicators, showing the synergy seen with other energies, but also the potential capability for phasing of the electromagnetic field. As a result, larger, more customizable ablation zones may be created in less time. Although multiple microwave ablation systems are currently available, further study and continued development are needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical properties of tissue : a comprehensive reference book
Duck, F. A. (1990) · Cited by 1,675
Microwave Ablation: Principles and Applications
Simon, C. J., Dupuy, D. E., & Mayo-Smith, W. W. (2005) · RadioGraphics · doi:10.1148/rg.25si055501 · Cited by 1,023
Brace, C. L. (2009) · Current Problems in Diagnostic Radiology · doi:10.1067/j.cpradiol.2007.10.001 · Cited by 624
Self-citationGervais, D. A., McGovern, F. J., Arellano, R. S., McDougal, W. S., & Mueller, P. R. (2005) · American Journal of Roentgenology · doi:10.2214/ajr.185.1.01850064 · Cited by 587
Shibata, T., Iimuro, Y., Yamamoto, Y., Maetani, Y., Ametani, F., Itoh, K., & Konishi, J. (2002) · Radiology · doi:10.1148/radiol.2232010775 · Cited by 575
Microwave Ablation of Lung Malignancies: Effectiveness, CT Findings, and Safety in 50 Patients
Wolf, F. J., Grand, D. J., Machan, J. T., DiPetrillo, T. A., Mayo-Smith, W. W., & Dupuy, D. E. (2008) · Radiology · doi:10.1148/radiol.2473070996 · Cited by 398
Liang, P., Wang, Y., Yu, X., & Dong, B. (2009) · Radiology · doi:10.1148/radiol.2513081740 · Cited by 378
Reference values for resting blood flow to organs of man
Williams, L. R., & Leggett, R. W. (1989) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/10/3/001 · Cited by 356
Wright, A. S., Lee, F. T., & Mahvi, D. M. (2003) · Annals of Surgical Oncology · doi:10.1245/aso.2003.03.045 · Cited by 317
Self-citationSkinner, M. G., Iizuka, M. N., Kolios, M. C., & Sherar, M. D. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/12/011 · Cited by 252
Cited by
Omata, M., Cheng, A.-L., Kokudo, N., Kudo, M., Lee, J. M., Jia, J., Tateishi, R., Han, K.-H., Chawla, Y. K., Shiina, S., et al. (2017) · Hepatology International · doi:10.1007/s12072-017-9799-9 · Cited by 2,171
Thermal ablation of tumours: biological mechanisms and advances in therapy
Chu, K. F., & Dupuy, D. E. (2014) · Nature Reviews Cancer · doi:10.1038/nrc3672 · Cited by 1,988
The Use of Alternative Strategies for Enhanced Nanoparticle Delivery to Solid Tumors
Izci, M., Maksoudian, C., Manshian, B. B., & Soenen, S. J. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00779 · Cited by 506
Phototherapy in cancer treatment: strategies and challenges
Cai, Y., Chai, T., Nguyen, W., Liu, J., Xiao, E., Ran, X., Ran, Y., Du, D., Chen, W., & Chen, X. (2025) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-025-02140-y · Cited by 453
Chemophototherapy: An Emerging Treatment Option for Solid Tumors
Luo, D., Carter, K. A., Miranda, D., & Lovell, J. F. (2017) · Advanced Science · doi:10.1002/advs.201600106 · Cited by 436
Heating technology for malignant tumors: a review
Kok, H. P., Cressman, E. N. K., Ceelen, W., Brace, C. L., Ivkov, R., Grüll, H., ter Haar, G., Wust, P., & Crezee, J. (2020) · International Journal of Hyperthermia · doi:10.1080/02656736.2020.1779357 · Cited by 422
Self-citationTumor Ablation: Common Modalities and General Practices
Knavel, E. M., & Brace, C. L. (2013) · Techniques in Vascular and Interventional Radiology · doi:10.1053/j.tvir.2013.08.002 · Cited by 368
Self-citationPoulou, L. S. (2015) · World Journal of Hepatology · doi:10.4254/wjh.v7.i8.1054 · Cited by 340
Orloff, L. A., Noel, J. E., Stack, B. C., Russell, M. D., Angelos, P., Baek, J. H., Brumund, K. T., Chiang, F., Cunnane, M. B., Davies, L., et al. (2022) · Head & Neck · doi:10.1002/hed.26960 · Cited by 315
Vietti Violi, N., Duran, R., Guiu, B., Cercueil, J.-P., Aubé, C., Digklia, A., Pache, I., Deltenre, P., Knebel, J.-F., & Denys, A. (2018) · The Lancet Gastroenterology & Hepatology · doi:10.1016/s2468-1253(18)30029-3 · Cited by 302
Colorectal liver metastases: Current management and future perspectives
Martin, J., Petrillo, A., Smyth, E. C., Shaida, N., Khwaja, S., Cheow, H., Duckworth, A., Heister, P., Praseedom, R., Jah, A., et al. (2020) · World Journal of Clinical Oncology · doi:10.5306/wjco.v11.i10.761 · Cited by 275
Emerging Nanomedicine‐Enabled/Enhanced Nanodynamic Therapies beyond Traditional Photodynamics
Hu, H., Feng, W., Qian, X., Yu, L., Chen, Y., & Li, Y. (2021) · Advanced Materials · doi:10.1002/adma.202005062 · Cited by 267
Ojha, T., Pathak, V., Shi, Y., Hennink, W. E., Moonen, C. T. W., Storm, G., Kiessling, F., & Lammers, T. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2017.07.007 · Cited by 260
Pillai, K., Akhter, J., Chua, T. C., Shehata, M., Alzahrani, N., Al-Alem, I., & Morris, D. L. (2015) · Medicine · doi:10.1097/md.0000000000000580 · Cited by 245
“The capacity to heat surrounding tissues more efficiently by MWs may have contributed to this observation.(25) Evaluation of heat sink on lateral and longitudinal dimensions ablated also showed lesser effect in MW compared with MP and BP.”
BackgroundKorean Liver Cancer Study Group (KLCSG), & National Cancer Center, K. (. (2015) · Korean Journal of Radiology · doi:10.3348/kjr.2015.16.3.465 · Cited by 201
“In addition, effective ablation can be expected even for tissues with low electrical conductivity, and the simultaneous application of multiple electrodes is technically feasible with this technique (280, 281).”
BackgroundJin, Y., Liang, X., An, Y., & Dai, Z. (2016) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.6b00603 · Cited by 72
Present and future of metal nanoparticles in tumor ablation therapy
Lou, W., Xie, L., Xu, L., Xu, M., Xu, F., Zhao, Q., & Jiang, T. (2023) · Nanoscale · doi:10.1039/d3nr04362b · Cited by 33
Oligometastatic Colorectal Cancer: A Review of Definitions and Patient Selection for Local Therapies
Miller, E. D., Hitchcock, K. E., & Romesser, P. B. (2023) · Journal of Gastrointestinal Cancer · doi:10.1007/s12029-022-00900-5 · Cited by 31
“Microwave ablation (MWA) is gaining popularity for the treatment of liver metastases due to technical advantages over RFA [33].”
Metadata
- Authors
- Lubner, M. G., Brace, C. L., Hinshaw, J. L., & Lee, F. T.
- Venue
- Journal of Vascular and Interventional Radiology
- Publisher
- Elsevier BV
- Published
- 2010-08
- Volume
- 21
- Issue
- 8
- Pages
- S192-S203
- ISSN
- 1051-0443 (ISSN-L)
- OpenAlex
- W2155763772
- Cited by
- 765
- References
- 25
- FWCI
- 13.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.