Multimodal Smart Eyewear for Longitudinal Eye Movement Tracking
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Summary Contextual measurements of multiple physiological signals using familiar garments or accessories can provide insights into health and behavior. Recording these signals on or near the face is challenging because most subjects are sensitive to implements placed on the face or head. Here, fabric electrodes and garment design strategies are used synergistically to afford an unobtrusive platform, Chesma, for longitudinal acquisition of physiological signals from a user's face. Chesma contains two novel fabric-based electrodes: a hydrogel electrode (tAgTrode) that retains its ionic character after multiple uses/washes, does not cause skin irritation, and can be continuously operated for upward of 8 h without losing signal integrity. Second is an ion-conductive fabric pressure sensor (Press-ION) that captures pulse waveforms. When sewn onto a lightweight eye mask, these electrodes simultaneously gather complementary electro-oculography and cardiac data, which can enable sleep quality and psychological studies and improve the accuracy and usability of virtual reality headsets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The porous nature of hydrogels provides a scaffold for creating soft electrodes40, microneedle arrays41, wicking structures for the collection of bodily fluids42,43, or even transparent batteries44.”
From End-to-end design of wearable sensors (2022) · cites this paper as [40]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanomaterial-Enabled Wearable Sensors for Healthcare
Yao, S., Swetha, P., & Zhu, Y. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700889 · Cited by 576
Kim, T., Park, J., Sohn, J., Cho, D., & Jeon, S. (2016) · ACS Nano · doi:10.1021/acsnano.6b01355 · Cited by 474
Photo-Rechargeable Fabrics as Sustainable and Robust Power Sources for Wearable Bioelectronics
Zhang, N., Huang, F., Zhao, S., Lv, X., Zhou, Y., Xiang, S., Xu, S., Li, Y., Chen, G., Tao, C., et al. (2020) · Matter · doi:10.1016/j.matt.2020.01.022 · Cited by 260
Novel dry electrodes for ECG monitoring
Gruetzmann, A., Hansen, S., & Müller, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/11/005 · Cited by 248
Imperceptible electrooculography graphene sensor system for human–robot interface
Ameri, S. K., Kim, M., Kuang, I. A., Perera, W. K., Alshiekh, M., Jeong, H., Topcu, U., Akinwande, D., & Lu, N. (2018) · npj 2D Materials and Applications · doi:10.1038/s41699-018-0064-4 · Cited by 162
Automating sleep stage classification using wireless, wearable sensors
Boe, A. J., McGee Koch, L. L., O’Brien, M. K., Shawen, N., Rogers, J. A., Lieber, R. L., Reid, K. J., Zee, P. C., & Jayaraman, A. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0210-1 · Cited by 98
Research works printed but not linked: 52
- Meng, 2020, A wireless textile-based sensor system for self-powered personalized health care, Matter, 2, 896, 10.1016/j.matt.2019.12.025 · DOI · Paper page
- Chen, 2020, Smart textiles for electricity generation, Chem. Rev., 120, 3668, 10.1021/acs.chemrev.9b00821 · DOI · Paper page
- Majumder, 2018, Noncontact wearable wireless ECG systems for long-term monitoring, IEEE Rev. Biomed. Eng., 11, 306, 10.1109/RBME.2018.2840336 · DOI · Paper page
- Weder, 2015, Embroidered electrode with silver/titanium coating for long-term ECG monitoring, Sensors (Switzerland), 15, 1750, 10.3390/s150101750 · DOI
- Takamatsu, 2015, Direct patterning of organic conductors on knitted textiles for long-term electrocardiography, Sci. Rep., 5, 10.1038/srep15003 · DOI · Paper page
- Sinha, 2017, Screen-printed PEDOT:PSS electrodes on commercial finished textiles for electrocardiography, ACS Appl. Mater. Interfaces, 9, 37524, 10.1021/acsami.7b09954 · DOI · Paper page
- Bihar, 2017, Inkjet-printed PEDOT: PSS electrodes on paper for electrocardiography, Adv. Healthc. Mater., 6, 1601167, 10.1002/adhm.201601167 · DOI
- Pani, 2018, Survey on textile electrode technologies for electrocardiographic (ECG) monitoring, from metal wires to polymers, Adv. Mater. Technol., 3, 1800008, 10.1002/admt.201800008 · DOI
- Ramasamy, 2018, Wearable sensors for ECG measurement: a review, Sens. Rev., 38, 412, 10.1108/SR-06-2017-0110 · DOI
- Golparvar, 2017, Wearable graphene textile-enabled EOG sensing, Proc. IEEE Sensors, 2017
- Liang, 2015, Development of an EOG-based automatic sleep-monitoring eye mask, IEEE Trans. Instrum. Meas., 64, 2977, 10.1109/TIM.2015.2433652 · DOI
- Kanoh, 2015, Development of an eyewear to measure eye and body movements, Proc. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc. EMBS, 2015, 2267
- Alba, 2010, Novel hydrogel-based preparation-free EEG electrode, IEEE Trans. Neural Syst. Rehabil. Eng., 18, 415, 10.1109/TNSRE.2010.2048579 · DOI
- Lin, 2011, Novel dry polymer foam electrodes for long-term EEG measurement, IEEE Trans. Biomed. Eng., 58, 1200, 10.1109/TBME.2010.2102353 · DOI · Paper page
- Crea, 2018, Feasibility and safety of shared EEG/EOG and vision-guided autonomous whole-arm exoskeleton control to perform activities of daily living, Sci. Rep., 8, 10.1038/s41598-018-29091-5 · DOI
- Chi, 2010, Dry-contact and noncontact biopotential electrodes: methodological review, IEEE Rev. Biomed. Eng., 3, 106, 10.1109/RBME.2010.2084078 · DOI · Paper page
- Acar, 2019, Wearable and flexible textile electrodes for biopotential signal monitoring: a review, Electron, 8
- Bulling, 2009, Wearable EOG goggles: seamless sensing and context-awareness in everyday environments, J. Ambient Intell. Smart Environ., 1, 157, 10.3233/AIS-2009-0020 · DOI
- Vidal, 2012, Wearable eye tracking for mental health monitoring, Comput. Commun., 35, 1306, 10.1016/j.comcom.2011.11.002 · DOI · Paper page
- Banerjee, 2014, Biomedical Signal Processing and Control Eye movement sequence analysis using electrooculogram to assist autistic children, Biomed. Signal. Process. Control, 14, 134, 10.1016/j.bspc.2014.07.010 · DOI
- Crawford, 2005, Inhibitory control of saccadic eye movements and cognitive impairment in Alzheimer’s disease, J. Biol. Psychiatry, 57, 1052, 10.1016/j.biopsych.2005.01.017 · DOI · Paper page
- Cruz-Aguilar, 2020, Melatonin effects on EEG activity during non-rapid eye movement sleep in mild-to-moderate Alzheimer’s disease: a pilot study, Int. J. Neurosci.
- Winsky-Sommerer, 2019, Disturbances of sleep quality, timing and structure and their relationship with other neuropsychiatric symptoms in Alzheimer’s disease and schizophrenia: insights from studies in patient populations and animal models, Neurosci. Biobehav. Rev., 97, 112, 10.1016/j.neubiorev.2018.09.027 · DOI
- Danjou, 2019, Electrophysiological assessment methodology of sensory processing dysfunction in schizophrenia and dementia of the Alzheimer type, Neurosci. Biobehav. Rev., 97, 70, 10.1016/j.neubiorev.2018.09.004 · DOI
- Kumar, 2016, Electrooculogram-based Virtual Reality game control using blink detection and gaze calibration, Int. Conf. Adv. Comput. Commun. Inform., 2016, 2358
- Xiao, 2019, An electrooculogram-based interaction method and its music-on-demand application in a virtual reality environment, IEEE Access, 7, 22059, 10.1109/ACCESS.2019.2898324 · DOI
- López, 2018, Development of an EOG-based system to control a serious game, Meas. J. Int. Meas. Confed., 127, 481, 10.1016/j.measurement.2018.06.017 · DOI
- Avenel-Audran, 2003, Contact dermatitis from electrocardiograph-monitoring electrodes: role of p-tert-butylphenol-formaldehyde resin, Contact Dermatitis, 48, 108, 10.1034/j.1600-0536.2003.480210.x · doi:10.1034/j.1600-0536.2003.480210.x
- Golparvar, 2018, Electrooculography by wearable graphene textiles, IEEE Sens. J., 18, 8971, 10.1109/JSEN.2018.2868879 · DOI
- Arnin, 2013, Wireless-based portable EEG-EOG monitoring for real time drowsiness detection, 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 4977
- Rostaminia, 2019, W!NCE: unobtrusive sensing of upper facial action units with EOG-based eyewear, Proc. ACM Interact. Mob. Wearable Ubiquitous Technol., 3, 10.1145/3314410 · DOI
- Penzel, 2003, Dynamics of heart rate and sleep stages in normals and patients with sleep apnea, Neuropsychopharmacology, 28, S48, 10.1038/sj.npp.1300146 · DOI · Paper page
- Medeiros, 2020, Abnormal atrial function in hypertensive patients with obstructive sleep apnea assessed by speckle tracking echocardiography, Hypertens. Res., 43, 841, 10.1038/s41440-020-0415-3 · DOI
- Mokhlesi, 2018, Obstructive sleep apnea and cardiovascular disease. REM sleep matters!, Am. J. Respir. Crit. Care Med., 197, 554, 10.1164/rccm.201710-2147ED · DOI
- Koo, 2018, Sleep disturbances as a risk factor for stroke, J. Stroke, 20, 12, 10.5853/jos.2017.02887 · DOI · Paper page
- Chouchou, 2014, Heart rate variability: a tool to explore the sleeping brain?, Front. Neurosci., 8, 10.3389/fnins.2014.00402 · DOI · Paper page
- Gupta, 2008, Initiated chemical vapor deposition (iCVD ) of conformal polymeric nanocoatings for the surface modification of high-aspect-ratio pores, Chem. Mater., 20, 1646, 10.1021/cm702810j · doi:10.1021/cm702810j
- Siafaka, 2016, Porous dressings of modified chitosan with poly(2-hydroxyethyl acrylate) for topical wound delivery of levofloxacin, Carbohydr. Polym., 143, 90, 10.1016/j.carbpol.2016.02.009 · DOI
- Gallego Ferrer, 2005, Poly(2-hydroxyethyl acrylate) hydrogel confined in a hydrophobous porous matrix, Colloid Polym. Sci., 283, 681, 10.1007/s00396-004-1208-y · doi:10.1007/s00396-004-1208-y
- Pradas, 2001, Porous poly(2-hydroxyethyl acrylate) hydrogels, Polymer, 42, 4667, 10.1016/S0032-3861(00)00742-4 · doi:10.1016/s0032-3861(00)00742-4
- Wanwong, 2019, Wash-stable, oxidation resistant conductive cotton electrodes for wearable electronics, RSC Adv., 9, 9198, 10.1039/C9RA00932A · DOI
- Soto, 2018, Short-fluorinated iCVD coatings for nonwetting fabrics, Adv. Funct. Mater., 28, 10.1002/adfm.201707355 · DOI
- Liu, 2019, Ingestible hydrogel device, Nat. Commun., 10, 493, 10.1038/s41467-019-08355-2 · DOI · Paper page
- Kiaghadi, 2019, Phyjama: physiological sensing via fiber-enhanced pyjamas, Proc. ACM Interact. Mob. Wearable Ubiquitous Technol., 3, 10.1145/3351247 · DOI · Paper page
- Sun, 2019, Ionogel-based, highly stretchable, transparent, durable triboelectric nanogenerators for energy harvesting and motion sensing over a wide temperature range, Nano Energy, 63, 103847, 10.1016/j.nanoen.2019.06.043 · DOI · Paper page
- Macdonald, 2006, Reflections on the history of electrochemical impedance spectroscopy, Electrochim. Acta, 51, 1376, 10.1016/j.electacta.2005.02.107 · DOI · Paper page
- Simini, F., Touya, A., Senatore, A., and Pereira, J. (2011). Gaze tracker by electrooculography (EOG) on a head-band 10th International Workshop on Biomedical Engineering, https://doi.org/10.1109/IWBE.2011.6079050. · doi:10.1109/iwbe.2011.6079050
- Gu, 2001, A study of natural eye movement detection and ocular implant movement control using processed EOG signals, vol. 2, 1555
- Hossain, 2015, Implementation of an EOG based security system by analyzing eye movement patterns, International Conference on Advances in Electrical Engineering (ICAEE), 149
- Barbara, 2019, EOG-based eye movement detection and gaze estimation for an asynchronous virtual keyboard, Biomed. Signal. Process. Control, 47, 159, 10.1016/j.bspc.2018.07.005 · doi:10.1016/j.bspc.2018.07.005
- Ireland, 1996, Factors affecting electrode-gel-skin interface impedance in electrical impedance tomography, Med. Biol. Eng. Comput., 34, 397, 10.1007/BF02523842 · DOI · Paper page
- Taji, 2014, Impact of skin-electrode interface on conductive textile electrodes, IEEE Trans. Instrum. Meas., 63, 1412, 10.1109/TIM.2013.2289072 · DOI · Paper page
Cited by
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
Smart textiles for personalized healthcare
Libanori, A., Chen, G., Zhao, X., Zhou, Y., & Chen, J. (2022) · Nature Electronics · doi:10.1038/s41928-022-00723-z · Cited by 739
Electronic Textiles for Wearable Point-of-Care Systems
Chen, G., Xiao, X., Zhao, X., Tat, T., Bick, M., & Chen, J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00502 · Cited by 688
Zhu, M., Li, J., Yu, J., Li, Z., & Ding, B. (2022) · Angewandte Chemie International Edition · doi:10.1002/anie.202200226 · Cited by 191
Han, Q., Zhang, C., Guo, T., Tian, Y., Song, W., Lei, J., Li, Q., Wang, A., Zhang, M., Bai, S., et al. (2023) · Advanced Materials · doi:10.1002/adma.202209606 · Cited by 181
Metadata
- Authors
- Homayounfar, S. Z., Rostaminia, S., Kiaghadi, A., Chen, X., Alexander, E. T., Ganesan, D., & Andrew, T. L.
- Venue
- Matter
- Publisher
- Elsevier BV
- Published
- 2020-10
- Volume
- 3
- Issue
- 4
- Pages
- 1275-1293
- ISSN
- 2590-2385
- Cited by
- 59
- References
- 6
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- www.elsevier.com/open-access/userlicense/1.0/ (vor, 371 d)
- Funders
- National Science Foundation
- David and Lucile Packard Foundation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.