The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Nanosensors and nanomaterials for monitoring glucose in diabetes
Open accessAbstract
Worldwide, diabetes is a rapidly growing problem that is managed at the individual level by monitoring and controlling blood glucose levels to minimize the negative effects of the disease. Because of limitations in diagnostic methods, significant research efforts are focused on developing improved methods to measure glucose. Nanotechnology has impacted these efforts by increasing the surface area of sensors, improving the catalytic properties of electrodes and providing nanoscale sensors. Herein, we discuss developments in the past several years on both nanosensors that directly measure glucose as well as nanomaterials that improve glucose sensor function. Finally, we discuss challenges that must be overcome to apply these developments in the clinic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Jiang, L.-C., & Zhang, W.-D. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.10.038 · Cited by 667
Nonenzymatic Electrochemical Glucose Sensor Based on Nanoporous PtPb Networks
Wang, J., Thomas, D. F., & Chen, A. (2008) · Analytical Chemistry · doi:10.1021/ac701790z · Cited by 534
Synthesis of CuO nanostructures and their application for nonenzymatic glucose sensing
Wang, X., Hu, C., Liu, H., Du, G., He, X., & Xi, Y. (2010) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.09.067 · Cited by 415
Projecting the Future Diabetes Population Size and Related Costs for the U.S.
Huang, E. S., Basu, A., O'Grady, M., & Capretta, J. C. (2009) · Diabetes Care · doi:10.2337/dc09-0459 · Cited by 414
Meng, L., Jin, J., Yang, G., Lu, T., Zhang, H., & Cai, C. (2009) · Analytical Chemistry · doi:10.1021/ac901005p · Cited by 412
Liu, Y., Teng, H., Hou, H., & You, T. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.04.032 · Cited by 391
Emerging synergy between nanotechnology and implantable biosensors: A review
Vaddiraju, S., Tomazos, I., Burgess, D. J., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.001 · Cited by 368
Wu, P., He, Y., Wang, H.-F., & Yan, X.-P. (2010) · Analytical Chemistry · doi:10.1021/ac902531g · Cited by 345
Kong, T., Chen, Y., Ye, Y., Zhang, K., Wang, Z., & Wang, X. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.01.002 · Cited by 319
Wang, Z., Liu, S., Wu, P., & Cai, C. (2009) · Analytical Chemistry · doi:10.1021/ac802421h · Cited by 307
Fabrication of a glucose sensor based on a novel nanocomposite electrode
Safavi, A., Maleki, N., & Farjami, E. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.08.040 · Cited by 296
Tang, B., Cao, L., Xu, K., Zhuo, L., Ge, J., Li, Q., & Yu, L. (2008) · Chemistry – A European Journal · doi:10.1002/chem.200701871 · Cited by 280
Shamsipur, M., Najafi, M., & Hosseini, M.-R. M. (2010) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2009.07.007 · Cited by 251
Gold nanowire array electrode for non-enzymatic voltammetric and amperometric glucose detection
Cherevko, S., & Chung, C.-H. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.07.023 · Cited by 251
Feng, D., Wang, F., & Chen, Z. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.02.048 · Cited by 236
A practical glucose biosensor based on Fe3O4 nanoparticles and chitosan/nafion composite film
Yang, L., Ren, X., Tang, F., & Zhang, L. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.09.002 · Cited by 231
Pang, X., He, D., Luo, S., & Cai, Q. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2008.09.051 · Cited by 221
Baby, T. T., & Ramaprabhu, S. (2010) · Talanta · doi:10.1016/j.talanta.2009.11.010 · Cited by 220
Lin, J., He, C., Zhao, Y., & Zhang, S. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.01.033 · Cited by 214
ZnO Nanotube Arrays as Biosensors for Glucose
Yang, K., She, G.-W., Wang, H., Ou, X.-M., Zhang, X.-H., Lee, C.-S., & Lee, S.-T. (2009) · The Journal of Physical Chemistry C · doi:10.1021/jp901894j · Cited by 202
Luo, D., Wu, L., & Zhi, J. (2009) · ACS Nano · doi:10.1021/nn9003154 · Cited by 196
Pt Nanoparticles Inserting in Carbon Nanotube Arrays: Nanocomposites for Glucose Biosensors
Wen, Z., Ci, S., & Li, J. (2009) · The Journal of Physical Chemistry C · doi:10.1021/jp902830z · Cited by 186
Glucose Biosensor Based on Nanocomposite Films of CdTe Quantum Dots and Glucose Oxidase
Li, X., Zhou, Y., Zheng, Z., Yue, X., Dai, Z., Liu, S., & Tang, Z. (2009) · Langmuir · doi:10.1021/la900066z · Cited by 177
Usman Ali, S. M., Nur, O., Willander, M., & Danielsson, B. (2010) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.12.072 · Cited by 176
Cella, L. N., Chen, W., Myung, N. V., & Mulchandani, A. (2010) · Journal of the American Chemical Society · doi:10.1021/ja100503b · Cited by 176
Chen, X.-M., Lin, Z., Chen, D.-J., Jia, T., Cai, Z.-M., Wang, X., Chen, X., Chen, G., & Oyama, M. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.035 · Cited by 157
Reversible Control of Carbon Nanotube Aggregation for a Glucose Affinity Sensor
Barone, P. W., & Strano, M. S. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200603138 · Cited by 153
Enzyme-free amperometric sensing of glucose using Cu-CuO nanowire composites
Wang, G., Yan, W., Zhang, W., Zhang, X., Fang, B., & Wang, L. (2009) · Microchimica Acta · doi:10.1007/s00604-009-0260-1 · Cited by 145
Cherevko, S., & Chung, C. (2009) · Talanta · doi:10.1016/j.talanta.2009.09.038 · Cited by 136
Wired-Enzyme Core−Shell Au Nanoparticle Biosensor
Scodeller, P., Flexer, V., Szamocki, R., Calvo, E. J., Tognalli, N. G., Troiani, H. E., & Fainstein, A. (2008) · Journal of the American Chemical Society · doi:10.1021/ja802318f · Cited by 124
Nanomedicine and its potential in diabetes research and practice
Pickup, J. C., Zhi, Z., Khan, F., Saxl, T., & Birch, D. J. S. (2008) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.893 · Cited by 124
Gopalan, A., Lee, K. P., Dhanusuraman, R., Lee, S. H., & Lee, J. W. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.07.047 · Cited by 123
Rathod, D. G., Dickinson, C., Egan, D. A., & Dempsey, E. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.09.064 · Cited by 118
Amperometric glucose biosensor based on NiFe2O4 nanoparticles and chitosan
Luo, L., Li, Q., Xu, Y., et al. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.12.018 · Cited by 117
Electrochemical oxidation of glucose on silver nanoparticle-modified composite electrodes
Quan, H., Park, S.-U., & Park, J. (2009) · Electrochimica Acta · doi:10.1016/j.electacta.2009.11.074 · Cited by 115
Functional One‐Dimensional Nanomaterials: Applications in Nanoscale Biosensors
Chopra, N., Gavalas, V. G., Bachas, L. G., Hinds, B. J., & Bachas, L. G. (2007) · Analytical Letters · doi:10.1080/00032710701567170 · Cited by 104
Li, J., Wei, X., & Yuan, Y. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.03.004 · Cited by 104
Self-assembled microstructure of carbon nanotubes for enzymeless glucose sensor
Li, X., Zhu, Q., Tong, S., Wang, W., & Song, W. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.10.051 · Cited by 100
Babu, T. G. S., & Ramachandran, T. (2009) · Electrochimica Acta · doi:10.1016/j.electacta.2009.10.034 · Cited by 96
Modulation of Single-Walled Carbon Nanotube Photoluminescence by Hydrogel Swelling
Barone, P. W., Yoon, H., Ortiz-García, R., Zhang, J., Ahn, J., Kim, J., & Strano, M. S. (2009) · ACS Nano · doi:10.1021/nn901025x · Cited by 89
Continuous Glucose Monitoring: The Future of Diabetes Management
Burge, M. R., Mitchell, S., Sawyer, A. M., & Schade, D. S. (2008) · Diabetes Spectrum · doi:10.2337/diaspect.21.2.112 · Cited by 78
Novel potentiometric approach in glucose biosensor using silver nanoparticles as redox marker
Ngeontae, W., Janrungroatsakul, W., Maneewattanapinyo, P., Ekgasit, S., Aeungmaitrepirom, W., & Tuntulani, T. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.11.003 · Cited by 75
Optical colorimetric sensor strip for direct readout glucose measurement
Wang, X., Chen, H., Zhou, T., Lin, Z., Zeng, J., Xie, Z., Chen, X., Wong, K., Chen, G., & Wang, X. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.05.018 · Cited by 68
Single Walled Carbon Nanotubes as Reporters for the Optical Detection of Glucose
Barone, P. W., & Strano, M. S. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300204 · Cited by 68
Sugar‐Responsive Fluorescent Nanospheres
Zenkl, G., Mayr, T., & Klimant, I. (2007) · Macromolecular Bioscience · doi:10.1002/mabi.200700174 · Cited by 67
Labib, M., Hedström, M., Amin, M. A., & Mattìasson, B. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.11.028 · Cited by 64
Saxl, T., Khan, F., Matthews, D. R., Zhi, Z., Rolinski, O. J., Ameer‐Beg, S., & Pickup, J. C. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.04.003 · Cited by 61
Wang, X., Zhang, Y., Banks, C. E., Chen, Q., & Ji, X. (2010) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2010.03.035 · Cited by 57
Miao, F., Tao, B., Sun, L. J., Liu, T., You, J., Wang, L., & Chu, P. K.-H. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.05.002 · Cited by 56
Gao, F., Luo, F., Chen, X., Wu, Y., Yin, J., Yao, Z., & Wang, L. (2009) · Talanta · doi:10.1016/j.talanta.2009.06.050 · Cited by 55
Glucose biosensor based on the room-temperature phosphorescence of TiO2/SiO2 nanocomposite
Li, Y., Liu, X., Yuan, H., & Xiao, D. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.05.033 · Cited by 53
Photoelectrochemical glucose biosensor incorporating CdS nanoparticles
Sun, J., Zhu, Y., Yang, X., & Li, C. (2009) · Particuology · doi:10.1016/j.partic.2009.04.009 · Cited by 45
Toward real-time continuous brain glucose and oxygen monitoring with a smart catheter
Li, C., Ahn, C. H., Shutter, L., & Narayan, R. K. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.06.032 · Cited by 41
A novel approach to ultrasensitive diagnosis using supramolecular protein nanoparticles
Lee, S., Lee, H., Park, J.-S., Choi, H. J., Han, K., Seo, H.-S., Ahn, K.-Y., Han, S., Cho, Y., Lee, K., et al. (2007) · The FASEB Journal · doi:10.1096/fj.06-7303com · Cited by 40
Zhang, Y., Guo, G., Zhao, F., Mo, Z., Xiao, F., & Zeng, B. (2009) · Electroanalysis · doi:10.1002/elan.200900306 · Cited by 40
Fluorescent acrylamide nanoparticles for boronic acid based sugar sensing — from probes to sensors
Zenkl, G., & Klimant, I. (2009) · Microchimica Acta · doi:10.1007/s00604-009-0172-0 · Cited by 36
Long-term calibration considerations during subcutaneous microdialysis sampling in mobile rats
Mou, X., Lennartz, M. R., Loegering, D. J., & Stenken, J. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.02.016 · Cited by 33
The region ion sensitive field effect transistor, a novel bioelectronic nanosensor
Risveden, K., Pontén, J. F., Calander, N. P., Willander, M., & Danielsson, B. R. G. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.01.019 · Cited by 30
Chaudhary, A., Raina, M., Härmä, H., Hanninen, P. E., McShane, M. J., & Srivastava, R. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22500 · Cited by 21
Near‐Infrared Resonance Energy Transfer Glucose Biosensors in Hybrid Microcapsule Carriers
Chinnayelka, S., Zhu, H., & McShane, M. J. (2008) · Journal of Sensors · doi:10.1155/2008/346016 · Cited by 15
Cited by
Zhang, Q., Zhang, K., Xu, D., Yang, G., Huang, H., Nie, F., Liu, C., & Yang, S. (2014) · Progress in Materials Science · doi:10.1016/j.pmatsci.2013.09.003 · Cited by 1,404
The Toxic Effects and Mechanisms of CuO and ZnO Nanoparticles
Chang, Y.-N., Zhang, M., Xia, L., Zhang, J., & Xing, G. (2012) · Materials · doi:10.3390/ma5122850 · Cited by 772
Graphene: Promises, Facts, Opportunities, and Challenges in Nanomedicine
Mao, H. Y., Laurent, S., Chen, W., Akhavan, O., Imani, M., Ashkarran, A. A., & Mahmoudi, M. (2013) · Chemical Reviews · doi:10.1021/cr300335p · Cited by 701
Optical methods for sensing glucose
Steiner, M.-S., Duerkop, A., & Wolfbeis, O. S. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15063d · Cited by 497
Flexible Electrochemical Bioelectronics: The Rise of In Situ Bioanalysis
Yu, Y., Nyein, H. Y. Y., Gao, W., & Javey, A. (2020) · Advanced Materials · doi:10.1002/adma.201902083 · Cited by 349
Metadata
- Authors
- Cash, K. J., & Clark, H. A.
- Venue
- Trends in Molecular Medicine
- Publisher
- Elsevier BV
- Published
- 2010-12
- Volume
- 16
- Issue
- 12
- Pages
- 584-593
- ISSN
- 1471-4914 (ISSN-L)
- OpenAlex
- W2038055857
- Cited by
- 369
- References
- 61
- FWCI
- 1.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.