T1 weighted brain images at 7 Tesla unbiased for Proton Density, T2⁎ contrast and RF coil receive B1 sensitivity with simultaneous vessel visualization
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
At high magnetic field, MR images exhibit large, undesirable signal intensity variations commonly referred to as “intensity field bias”. Such inhomogeneities mostly originate from heterogeneous RF coil B1 profiles and, with no appropriate correction, are further pronounced when utilizing rooted sum of square reconstruction with receive coil arrays. These artifacts can significantly alter whole brain high resolution T1-weighted (T1w) images that are extensively utilized for clinical diagnosis, for gray/white matter segmentation as well as for coregistration with functional time series. In T1 weighted 3D-MPRAGE sequences, it is possible to preserve a bulk amount of T1 contrast through space by using adiabatic inversion RF pulses that are insensitive to transmit B1 variations above a minimum threshold. However, large intensity variations persist in the images, which are significantly more difficult to address at very high field where RF coil B1 profiles become more heterogeneous. Another characteristic of T1w MPRAGE sequences is their intrinsic sensitivity to Proton Density and T2* contrast, which cannot be removed with post-processing algorithms utilized to correct for receive coil sensitivity. In this paper, we demonstrate a simple technique capable of producing normalized, high resolution T1w 3D-MPRAGE images that are devoid of receive coil sensitivity, Proton Density and T2* contrast. These images, which are suitable for routinely obtaining whole brain tissue segmentation at 7 Tesla, provide higher T1 contrast specificity than standard MPRAGE acquisitions. Our results show that removing the Proton Density component can help identifying small brain structures and that T2* induced artifacts can be removed from the images. The resulting unbiased T1w images can also be used to generate Maximum Intensity Projection angiograms, without additional data acquisition, that are inherently registered with T1w structural images. In addition, we introduce a simple technique to reduce residual signal intensity variations induced by Transmit B1 heterogeneity. Because this approach requires two 3D images, one divided with the other, head motion could create serious problems, especially at high spatial resolution. To alleviate such inter-scan motion problems, we developed a new sequence where the two contrast acquisitions are interleaved within a single scan. This interleaved approach however comes with greater risk of intra-scan motion issues because of a longer single scan time. Users can choose between these two trade offs depending on specific protocols and patient populations. We believe that the simplicity and the robustness of this double contrast based approach to address intensity field bias at high field and improve T1 contrast specificity, together with the capability of simultaneously obtaining angiography maps, advantageously counter balance the potential drawbacks of the technique, mainly a longer acquisition time and a moderate reduction in signal to noise ratio.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Data Reduction and Error Analysis for the Physical Sciences
Bevington, P. R., Robinson, D. K., Blair, J. M., Mallinckrodt, A. J., & McKay, S. (1993) · Computers in Physics · doi:10.1063/1.4823194 · Cited by 14,824
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630
Jenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
Roemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322
Three‐dimensional magnetization‐prepared rapid gradient‐echo imaging (3D MP RAGE)
Mugler, J. P., & Brookeman, J. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910150117 · Cited by 1,265
Yarnykh, V. L. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21120 · Cited by 1,026
7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890
Katscher, U., Börnert, P., Leussler, C., & van den Brink, J. S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10353 · Cited by 719
Snapshot flash mri. applications to t1, t2, and chemical‐shift imaging
Haase, A. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130109 · Cited by 693
Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivo
Rooney, W. D., Johnson, G., Li, X., Cohen, E. R., Kim, S., Ugurbil, K., & Springer, C. S. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21122 · Cited by 652
Cited by
The minimal preprocessing pipelines for the Human Connectome Project
Glasser, M. F., Sotiropoulos, S. N., Wilson, J. A., Coalson, T. S., Fischl, B., Andersson, J. L., Xu, J., Jbabdi, S., Webster, M., Polimeni, J. R., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.127 · Cited by 5,253
MP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high field
Marques, J. P., Kober, T., Krueger, G., van der Zwaag, W., Van de Moortele, P.-F., & Gruetter, R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.002 · Cited by 1,453
Self-citationMapping Human Cortical Areas In Vivo Based on Myelin Content as Revealed by T1- and T2-Weighted MRI
Glasser, M. F., & Van Essen, D. C. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.2180-11.2011 · Cited by 1,447
“These assumptions will not apply at higher resonant frequencies (i.e., at higher field strengths like 7T) where local transmit coils are used and where the transmit field biases are much stronger (Van de Moortele et al., 2009).”
Slow expansion of multiple sclerosis iron rim lesions: pathology and 7 T magnetic resonance imaging
Dal-Bianco, A., Grabner, G., Kronnerwetter, C., Weber, M., Höftberger, R., Berger, T., Auff, E., Leutmezer, F., Trattnig, S., Lassmann, H., et al. (2017) · Acta Neuropathologica · doi:10.1007/s00401-016-1636-z · Cited by 463
“Furthermore, we could not account for the effect of whole brain atrophy on longitudinal lesion volumes in this study, since brain volumetry using 7 T MRI is still challenging [37].”
BackgroundTrends and properties of human cerebral cortex: Correlations with cortical myelin content
Glasser, M. F., Goyal, M. S., Preuss, T. M., Raichle, M. E., & Van Essen, D. C. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.03.060 · Cited by 456
Contextual Feedback to Superficial Layers of V1
Muckli, L., De Martino, F., Vizioli, L., Petro, L. S., Smith, F. W., Ugurbil, K., Goebel, R., & Yacoub, E. (2015) · Current Biology · doi:10.1016/j.cub.2015.08.057 · Cited by 423
Self-citationClinical applications of 7T MRI in the brain
van der Kolk, A. G., Hendrikse, J., Zwanenburg, J. J. M., Visser, F., & Luijten, P. R. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.07.007 · Cited by 268
Goal-dependent dissociation of visual and prefrontal cortices during working memory
Lee, S.-H., Kravitz, D. J., & Baker, C. I. (2013) · Nature Neuroscience · doi:10.1038/nn.3452 · Cited by 246
Mapping Human Somatosensory Cortex in Individual Subjects With 7T Functional MRI
Sanchez-Panchuelo, R. M., Francis, S., Bowtell, R., & Schluppeck, D. (2010) · Journal of Neurophysiology · doi:10.1152/jn.01017.2009 · Cited by 227
Layer-specific fMRI reflects different neuronal computations at different depths in human V1
Olman, C. A., Harel, N., Feinberg, D. A., He, S., Zhang, P., Ugurbil, K., & Yacoub, E. (2012) · PLoS ONE · doi:10.1371/journal.pone.0032536 · Cited by 194
Mapping the Organization of Axis of Motion Selective Features in Human Area MT Using High-Field fMRI
Zimmermann, J., Goebel, R., De Martino, F., van de Moortele, P.-F., Feinberg, D., Adriany, G., Chaimow, D., Shmuel, A., Uğurbil, K., & Yacoub, E. (2011) · PLoS ONE · doi:10.1371/journal.pone.0028716 · Cited by 188
“Visual stimuli were presented using video projector and mirror at the rear of the magnet. An additional mirror was attached to the coil above the subject's eyes, allowing them to view a screen behind the coil where the image was projected onto. Stimuli were presented using custom-built stimulation software (StimulGL).…”
MethodSelf-citation7‐T MR—from research to clinical applications?
Moser, E., Stahlberg, F., Ladd, M. E., & Trattnig, S. (2012) · NMR in Biomedicine · doi:10.1002/nbm.1794 · Cited by 187
“Further evaluations are needed to show, for example, how this precise registration (96,97) between vessels and parenchyma can be helpful in the work-up of vascular stenosis.”
BackgroundAdvances in resting state fMRI acquisitions for functional connectomics
Raimondo, L., Oliveira, Ĺ. A. F., Heij, J., Priovoulos, N., Kundu, P., Leoni, R. F., & van der Zwaag, W. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118503 · Cited by 180
“High fields present several technical and methodological challenges, uch as inhomogeneous B0, receive and transmit RF coil sensitivity rofiles ( Van de Moortele et al., 2009 ; Yang et al., 2002 ).”
BackgroundRobust T1-Weighted Structural Brain Imaging and Morphometry at 7T Using MP2RAGE
O'Brien, K. R., Kober, T., Hagmann, P., Maeder, P., Marques, J., Lazeyras, F., Krueger, G., & Roche, A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0099676 · Cited by 179
“In addition to the estimation of a quantitative T1map, the ratio of the two image volumes was shown to correct for the proton density, T2* contrast, and B1 inhomogeneities [4,7].”
BackgroundMethodInfluentialGray and white matter changes associated with tool-use learning in macaque monkeys
Quallo, M. M., Price, C. J., Ueno, K., Asamizuya, T., Cheng, K., Lemon, R. N., & Iriki, A. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0909751106 · Cited by 177
“We found that the T1/T2* image provided the best contrast between gray and white matter (16, 17) (see Methods); images from the three different monkeys were spatially normalized by using a template based on gray matter MR images from 17 Japanese macaques and were used for the VBM analysis with SPM5 (15) (Wellcome Trus…”
MethodBrainVoyager — Past, present, future
Goebel, R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.083 · Cited by 173
“Since simulated and measured data co-exist in a common representational space, the same analysis tools (e.g. univariate GLM, multivariate pattern analysis, effective connectivity analysis) can be applied to both data sets (Peters et al., 2010; van de Ven et al., 2012).”
Groen, I. I., Greene, M. R., Baldassano, C., Fei-Fei, L., Beck, D. M., & Baker, C. I. (2018) · eLife · doi:10.7554/elife.32962 · Cited by 169
“…rapid-acquisition gradient echo) and corresponding GE-PD (gradient echo–proton density) images were acquired, and the MPRAGE images were then normalized by the GE-PD images for use as a high-resolution anatomical image for the following fMRI data analysis (Van de Moortele et al., 2009).”
MethodDe Martino, F., Moerel, M., Ugurbil, K., Goebel, R., Yacoub, E., & Formisano, E. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1507552112 · Cited by 166
Self-citationCortical Depth Dependent Functional Responses in Humans at 7T: Improved Specificity with 3D GRASE
De Martino, F., Zimmermann, J., Muckli, L., Ugurbil, K., Yacoub, E., & Goebel, R. (2013) · PLoS ONE · doi:10.1371/journal.pone.0060514 · Cited by 166
Self-citationGallichan, D., Marques, J. P., & Gruetter, R. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25670 · Cited by 162
Advanced MRI techniques to improve our understanding of experience-induced neuroplasticity
Tardif, C. L., Gauthier, C. J., Steele, C. J., Bazin, P.-L., Schäfer, A., Schaefer, A., Turner, R., & Villringer, A. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.047 · Cited by 127
Voxel-based morphometry at ultra-high fields. A comparison of 7T and 3T MRI data
Seiger, R., Hahn, A., Hummer, A., Kranz, G. S., Ganger, S., Küblböck, M., Kraus, C., Sladky, R., Kasper, S., Windischberger, C., et al. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.03.019 · Cited by 48
The human habenula is responsive to changes in luminance and circadian rhythm
Kaiser, C., Kaufmann, C., Leutritz, T., Arnold, Y. L., Speck, O., & Ullsperger, M. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.01.064 · Cited by 28
“Since heterogeneities in the local B0 field are especially prominent at high field strengths, signal intensity and contrast inhomogeneities in the MPRAGE image were corrected using the GE image as proposed by Van de Moortele et al. (2009).”
Bosse, K. E., Ghoddoussi, F., Eapen, A. T., Charlton, J. L., Susick, L. L., Desai, K., Berkowitz, B. A., Perrine, S. A., & Conti, A. C. (2019) · Brain Imaging and Behavior · doi:10.1007/s11682-018-9856-6 · Cited by 10
Metadata
- Authors
- Van de Moortele, P.-F., Auerbach, E. J., Olman, C., Yacoub, E., Uğurbil, K., & Moeller, S.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2009-06
- Volume
- 46
- Issue
- 2
- Pages
- 432-446
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2035613792
- Cited by
- 265
- References
- 39
- FWCI
- 10.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.