The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
A quantitative comparison of NIRS and fMRI across multiple cognitive tasks
Open accessAbstract
Near infrared spectroscopy (NIRS) is an increasingly popular technology for studying brain function. NIRS presents several advantages relative to functional magnetic resonance imaging (fMRI), such as measurement of concentration changes in both oxygenated- and deoxygenated hemoglobin, finer temporal resolution, and ease of administration, as well as disadvantages, most prominently inferior spatial resolution and decreased signal-to-noise ratio (SNR). While fMRI has become the gold standard for in vivo imaging of the human brain, in practice NIRS is a more convenient and less expensive technology than fMRI. It is therefore of interest to many researchers how NIRS compares to fMRI in studies of brain function. In the present study we scanned participants with simultaneous NIRS and fMRI on a battery of cognitive tasks, placing NIRS probes over both frontal and parietal brain regions. We performed detailed comparisons of the signals in both temporal and spatial domains. We found that NIRS signals have significantly weaker SNR, but are nonetheless often highly correlated with fMRI measurements. Both SNR and the distance between the scalp and the brain contributed to variability in the NIRS/fMRI correlations. In the spatial domain, we found that a photon path forming an ellipse between the NIRS emitter and detector correlated most strongly with the BOLD response. Taken together these findings suggest that, while NIRS can be an appropriate substitute for fMRI for studying brain activity related to cognitive tasks, care should be taken when designing studies with NIRS to ensure that: 1) the spatial resolution is adequate for answering the question of interest and 2) the design accounts for weaker SNR, especially in brain regions more distal from the scalp.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Dynamics of blood flow and oxygenation changes during brain activation: the Balloon model
Buxton, R. B., Wong, E. C., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390602 · Cited by 1,665
Strangman, G., Culver, J. P., Thompson, J. H., & Boas, D. A. (2002) · NeuroImage · doi:10.1006/nimg.2002.1227 · Cited by 1,415
Brain magnetic resonance imaging with contrast-dependent oxygenation
Ogawa, S. (1990) · Medical Entomology and Zoology · Cited by 1,367
Cope, M., & Delpy, D. T. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447083 · Cited by 1,065
A temporal comparison of BOLD, ASL, and NIRS hemodynamic responses to motor stimuli in adult humans
Huppert, T. J., Hoge, R. D., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.065 · Cited by 846
Cui, X., Bray, S., & Reiss, A. L. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.11.050 · Cited by 807
Self-citationInfluence of heart rate on the BOLD signal: The cardiac response function
Chang, C., Cunningham, J. P., & Glover, G. H. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.09.029 · Cited by 667
Self-citationSpiral‐in/out BOLD fMRI for increased SNR and reduced susceptibility artifacts
Glover, G. H., & Law, C. S. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1222 · Cited by 599
Self-citationSitaram, R., Zhang, H., Guan, C., Thulasidas, M., Hoshi, Y., Ishikawa, A., Shimizu, K., & Birbaumer, N. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.005 · Cited by 590
Strangman, G., Franceschini, M. A., & Boas, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00021-1 · Cited by 581
Brain–computer interface using a simplified functional near-infrared spectroscopy system
Coyle, S. M., Ward, T. E., & Markham, C. M. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/007 · Cited by 505
Okada, E., Firbank, M., Schweiger, M., Arridge, S. R., Cope, M., & Delpy, D. T. (1997) · Applied Optics · doi:10.1364/ao.36.000021 · Cited by 477
Kleinschmidt, A., Obrig, H., Requardt, M., Merboldt, K.-D., Dirnagl, U., Villringer, A., & Frahm, J. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199609000-00006 · Cited by 456
Malonek, D., Dirnagl, U., Lindauer, U., Yamada, K., Kanno, I., & Grinvald, A. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.26.14826 · Cited by 443
Toronov, V., Webb, A., Choi, J. H., Wolf, M., Michalos, A., Gratton, E., & Hueber, D. (2001) · Medical Physics · doi:10.1118/1.1354627 · Cited by 380
Zhang, Y., Brooks, D. H., Franceschini, M. A., & Boas, D. A. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1852552 · Cited by 373
On the suitability of near-infrared (NIR) systems for next-generation brain–computer interfaces
Coyle, S., Ward, T., Markham, C., & McDarby, G. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/003 · Cited by 361
Event-related functional near-infrared spectroscopy (fNIRS): Are the measurements reliable?
Plichta, M. M., Herrmann, M. J., Baehne, C. G., Ehlis, A.-C., Richter, M. M., Pauli, P., & Fallgatter, A. J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.12.008 · Cited by 358
Illuminating the BOLD signal: combined fMRI–fNIRS studies
Steinbrink, J., Villringer, A., Kempf, F., Haux, D., Boden, S., & Obrig, H. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.12.034 · Cited by 334
Use of fNIRS to assess resting state functional connectivity
Lu, C.-M., Zhang, Y.-J., Biswal, B. B., Zang, Y.-F., Peng, D.-L., & Zhu, C.-Z. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.11.010 · Cited by 294
Resting-state functional connectivity in the human brain revealed with diffuse optical tomography
White, B. R., Snyder, A. Z., Cohen, A. L., Petersen, S. E., Raichle, M. E., Schlaggar, B. L., & Culver, J. P. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.03.058 · Cited by 287
Okada, E., & Delpy, D. T. (2003) · Applied Optics · doi:10.1364/ao.42.002906 · Cited by 274
Mehagnoul‐Schipper, D. J., van der Kallen, B. F. W., Colier, W. N. J. M., van der Sluijs, M. C., van Erning, L. J. T. O., Thijssen, H. O. M., Oeseburg, B., Hoefnagels, W. H. L., & Jansen, R. W. M. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10026 · Cited by 264 · cited 5×
“Several other studies have found good correlation between NIRS and fMRI signals (Mehagnoul-Schipper et al., 2002; Kennan et al., 2002; Okamoto et al., 2004; Hoge et al., 2005; Toronov et al., 2001b; 2001a; Huppert et al., 2006b) in both simultaneous and sequential acquisitions on a range of tasks including motor, lang…”
InfluentialObata, T., Liu, T. T., Miller, K. L., Luh, W.-M., Wong, E. C., Frank, L. R., & Buxton, R. B. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.08.040 · Cited by 252
Multimodal assessment of cortical activation during apple peeling by NIRS and fMRI
Okamoto, M., Dan, H., Shimizu, K., Takeo, K., Amita, T., Oda, I., Konishi, I., Sakamoto, K., Isobe, S., Suzuki, T., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.12.003 · Cited by 224
Zhang, H., Zhang, Y.-J., Lu, C.-M., Ma, S.-Y., Zang, Y.-F., & Zhu, C.-Z. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.02.080 · Cited by 182
Can the cerebral metabolic rate of oxygen be estimated with near-infrared spectroscopy?
Boas, D. A., Strangman, G., Culver, J. P., Hoge, R. D., Jasdzewski, G., Poldrack, R. A., Rosen, B. R., & Mandeville, J. B. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/15/311 · Cited by 175
Toronov, V., Walker, S., Gupta, R., Choi, J. H., Gratton, E., Hueber, D. M., & WEBB, A. G. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00152-6 · Cited by 172
Investigating the post-stimulus undershoot of the BOLD signal—a simultaneous fMRI and fNIRS study
Schroeter, M. L., Kupka, T., Mildner, T., Uludaǧ, K., & von Cramon, D. Y. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.09.048 · Cited by 163
Power, S. D., Falk, T. H., & Chau, T. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026002 · Cited by 158
Hoge, R. D., Franceschini, M. A., Covolan, R. J. M., Huppert, T. J., Mandeville, J. B., & Boas, D. A. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.12.032 · Cited by 132
Kennan, R. P., Kim, D., Maki, A., Koizumi, H., & Constable, R. T. (2002) · Human Brain Mapping · doi:10.1002/hbm.10039 · Cited by 132
Functional neuroanatomy of visuo‐spatial working memory in turner syndrome
HABERECHT, M. F., Menon, V., Warsofsky, I. S., White, C. D., Dyer‐Friedman, J., Glover, G. H., Neely, E. K., & Reiss, A. L. (2001) · Human Brain Mapping · doi:10.1002/hbm.1044 · Cited by 132
Self-citationHuppert, T. J., Allen, M., Benav, H., Jones, P., & Boas, D. A. (2007) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600435 · Cited by 125
Toronov, V. Y., Zhang, X., & WEBB, A. G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.08.048 · Cited by 115
Suda, M., Takei, Y., Aoyama, Y., Narita, K., Sato, T., Fukuda, M., & Mikuni, M. (2009) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2009.09.036 · Cited by 108
Lee, J., Folley, B. S., Gore, J. C., & Park, S. (2008) · PLoS ONE · doi:10.1371/journal.pone.0001760 · Cited by 107
The effect of overlying tissue on the spatial sensitivity profile of near-infrared spectroscopy
Okada, E., Firbank, M., & Delpy, D. T. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/12/007 · Cited by 106
Hoeft, F., Hernandez, A., Parthasarathy, S., Watson, C., Hall, S. S., & Reiss, A. L. (2007) · Human Brain Mapping · doi:10.1002/hbm.20406 · Cited by 104
Self-citationFunctional Neuroanatomy of Spatial Orientation Processing in Turner Syndrome
Kesler, S. R., Haberecht, M. F., Menon, V., Warsofsky, I. S., Dyer-Friedman, J., Neely, E. K., & Reiss, A. L. (2003) · Cerebral Cortex · doi:10.1093/cercor/bhg116 · Cited by 104
Self-citationBoecker, M., Buecheler, M. V., Schroeter, M. L., & Gauggel, S. (2006) · Behavioural Brain Research · doi:10.1016/j.bbr.2006.10.009 · Cited by 87
Huppert, T. J., Hoge, R. D., Dale, A. M., Franceschini, M. A., & Boas, D. A. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2400910 · Cited by 87
Development of wearable optical topography system for mapping the prefrontal cortex activation
Atsumori, H., Kiguchi, M., Obata, A. N., Sato, H. R., Katura, T., Funane, T., & Maki, A. (2009) · Review of Scientific Instruments · doi:10.1063/1.3115207 · Cited by 82
Toronov, V. Y., WEBB, A. G., Choi, J. H., Wolf, M., Safonova, L. P., Wolf, U., & Gratton, E. (2001) · Optics Express · doi:10.1364/oe.9.000417 · Cited by 74
False Positives In Functional Nearinfrared Topography
Tachtsidis, I., Leung, T. S., Chopra, A., Koh, P. H., Reid, C. B., & Elwell, C. E. (2008) · Advances in experimental medicine and biology · doi:10.1007/978-0-387-85998-9_46 · Cited by 68
Detection of hypofrontality in drivers with Alzheimer's disease by near-infrared spectroscopy
Tomioka, H., Yamagata, B., Takahashi, T., Yano, M., Isomura, A. J., Kobayashi, H., & Mimura, M. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2008.12.059 · Cited by 65
Herrmann, M. J., Ehlis, A., Wagener, A., Jacob, C., & Fallgatter, A. J. (2005) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2005.02.011 · Cited by 61
Estimating cerebral oxygen metabolism from fMRI with a dynamic multicompartment Windkessel model
Huppert, T. J., Allen, M., Diamond, S. G., & Boas, D. A. (2008) · Human Brain Mapping · doi:10.1002/hbm.20628 · Cited by 59
The Effect of Optode Positioning on Optical Pathlength in Near Infrared Spectroscopy of Brain
van der Zee, P., Arridge, S., Cope, M., & Delpy, D. T. (1990) · Advances in experimental medicine and biology · doi:10.1007/978-1-4684-8181-5_11 · Cited by 57
How do infants perceive scrambled face?: A near-infrared spectroscopic study
Honda, Y., Nakato, E., Otsuka, Y., Kanazawa, S., Kojima, S., Yamaguchi, M. K., & Kakigi, R. (2009) · Brain Research · doi:10.1016/j.brainres.2009.10.046 · Cited by 55
Direct estimation of evoked hemoglobin changes by multimodality fusion imaging
Huppert, T. J., Diamond, S. G., & Boas, D. A. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2976432 · Cited by 42
Emir, U. E., Öztürk, C., & Akın, A. (2007) · Physiological Measurement · doi:10.1088/0967-3334/29/1/004 · Cited by 34
Topographic localization of brain activation in diffuse optical imaging using spherical wavelets
Abdelnour, F., Schmidt, B., & Huppert, T. J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/20/023 · Cited by 31
GO-STOP Control Using Optical Brain-Computer Interface during Calculation Task
Utsugi, K., Obata, A., Sato, H. R., Aoki, R., Maki, A., KOIZUMI, H., SAGARA, K., Kawamichi, H., Atsumori, H., & Katura, T. (2008) · IEICE Transactions on Communications · doi:10.1093/ietcom/e91-b.7.2133 · Cited by 11
An event-related fNIRS investigation of Japanese word order
Nishimura, Y., Sugisaki, K., Hattori, N., Inokuchi, Y., Komachi, M., Nishimura, Y., Ogawa, M., Okada, M., Okazaki, Y., Taki, W., et al. (2009) · Experimental Brain Research · doi:10.1007/s00221-009-2113-x · Cited by 5
Glover (2000) · doi:10.1002/1522-2594(200007)44:1<162::aid-mrm23>3.0.co;2-e
Cited by
Pinti, P., Tachtsidis, I., Hamilton, A., Hirsch, J., Aichelburg, C., Gilbert, S., & Burgess, P. W. (2020) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.13948 · Cited by 1,336
Overview of Functional Magnetic Resonance Imaging
Glover, G. H. (2011) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2010.11.001 · Cited by 1,024
“NIRS resolution is low (10–20 mm) and is limited predominantly by the strong scatter and attenuation of infrared photons (which also limits the depth of cortex that can be imaged within a bananashaped region connecting optodes), the modest density of optodes, and the ill-conditioned inverse problem of reconstructing 3…”
BackgroundSelf-citationCui, X., Bryant, D. M., & Reiss, A. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.003 · Cited by 807
Self-citationShining light on the head: Photobiomodulation for brain disorders
Hamblin, M. R. (2016) · BBA Clinical · doi:10.1016/j.bbacli.2016.09.002 · Cited by 627
Brain Photobiomodulation Therapy: a Narrative Review
Salehpour, F., Mahmoudi, J., Kamari, F., Sadigh-Eteghad, S., Rasta, S. H., & Hamblin, M. R. (2018) · Molecular Neurobiology · doi:10.1007/s12035-017-0852-4 · Cited by 517
Metadata
- Authors
- Cui, X., Bray, S., Bryant, D. M., Glover, G. H., & Reiss, A. L.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2011-02
- Volume
- 54
- Issue
- 4
- Pages
- 2808-2821
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2092770659
- Cited by
- 945
- References
- 57
- FWCI
- 19.04
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.