The DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.
The New York Head—A precise standardized volume conductor model for EEG source localization and tES targeting
Open accessAbstract
In source localization of electroencephalograpic (EEG) signals, as well as in targeted transcranial electric current stimulation (tES), a volume conductor model is required to describe the flow of electric currents in the head. Boundary element models (BEM) can be readily computed to represent major tissue compartments, but cannot encode detailed anatomical information within compartments. Finite element models (FEM) can capture more tissue types and intricate anatomical structures, but with the higher precision also comes the need for semi-automated segmentation, and a higher computational cost. In either case, adjusting to the individual human anatomy requires costly magnetic resonance imaging (MRI), and thus head modeling is often based on the anatomy of an 'arbitrary' individual (e.g. Colin27). Additionally, existing reference models for the human head often do not include the cerebro-spinal fluid (CSF), and their field of view excludes portions of the head and neck-two factors that demonstrably affect current-flow patterns. Here we present a highly detailed FEM, which we call ICBM-NY, or "New York Head". It is based on the ICBM152 anatomical template (a non-linear average of the MRI of 152 adult human brains) defined in MNI coordinates, for which we extended the field of view to the neck and performed a detailed segmentation of six tissue types (scalp, skull, CSF, gray matter, white matter, air cavities) at 0.5mm(3) resolution. The model was solved for 231 electrode locations. To evaluate its performance, additional FEMs and BEMs were constructed for four individual subjects. Each of the four individual FEMs (regarded as the 'ground truth') is compared to its BEM counterpart, the ICBM-NY, a BEM of the ICBM anatomy, an 'individualized' BEM of the ICBM anatomy warped to the individual head surface, and FEMs of the other individuals. Performance is measured in terms of EEG source localization and tES targeting errors. Results show that the ICBM-NY outperforms FEMs of mismatched individual anatomies as well as the BEM of the ICBM anatomy according to both criteria. We therefore propose the New York Head as a new standard head model to be used in future EEG and tES studies whenever an individual MRI is not available. We release all model data online at neuralengr.com/nyhead/ to facilitate broad adoption.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiple emitter location and signal parameter estimation
Schmidt, R. (1986) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.1986.1143830 · Cited by 14,718 · cited 1×
“Note that this approach is similar to the classical ‘multiple signal classification’ (MUSIC) scan (Schmidt, 1986; Mosher and Leahy, 1999).”
Oostenveld, R., Fries, P., Maris, E., & Schoffelen, J.-M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/156869 · Cited by 10,323
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507 · cited 1×
“Segmentation and electrode placement The two versions of the ICBM152 (v6 and v2009b), as well as the four individual heads (INDV1–4) were segmented using a probabilistic segmentation routine (New Segment, an extension of Unified Segmentation, (Ashburner and Friston, 2005)) in SPM8.”
Nitsche, M. A., & Paulus, W. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00633.x · Cited by 5,656
Spatial registration and normalization of images
Friston, K. J., Ashburner, J., Frith, C. D., Poline, J. ‐., Heather, J. D., & Frackowiak, R. S. J. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030303 · Cited by 3,744
Brainstorm: A User-Friendly Application for MEG/EEG Analysis
Tadel, F., Baillet, S., Mosher, J. C., Pantazis, D., & Leahy, R. M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/879716 · Cited by 3,677
Automatic 3D intersubject registration of MR volumetric data in standardized Talairach space
Collins, D. L., Neelin, P., Peters, T. M., & Evans, A. C. (1994) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199403000-00005 · Cited by 3,431 · cited 5×
“In addition to the MRI-to-native transform, a 12-parameter affine transform (M2) from the individual native space to the MNI reference-space defined by the MNI-305 template (Evans et al., 1993; Collins et al., 1994) was calculated for each individual using the ‘Normalise’ function (Friston et al., 1995) in SPM8.”
InfluentialIntroduction to Electrodynamics
Griffiths, D. J. (2017) · Cambridge University Press eBooks · doi:10.1017/9781108333511 · Cited by 3,408
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869
Mazziotta, J., Toga, A., Evans, A., Fox, P., Lancaster, J., Zilles, K., Woods, R., Paus, T., Simpson, G., Pike, B., et al. (2001) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.2001.0915 · Cited by 2,347
Unbiased average age-appropriate atlases for pediatric studies
Fonov, V., Evans, A. C., Botteron, K., Almli, C. R., McKinstry, R. C., & Collins, D. L. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.033 · Cited by 2,290 · cited 4×
“Specifically, we combined the highly detailed brain image of the ‘non-linear’ ICBM152 v2009b template (0.5 mm3 resolution, (Fonov et al., 2009, 2011)) with the highquality image of the non-brain area of the ICBM152 v6 template (1 mm3 resolution, (Grabner et al., 2006)).”
InfluentialUnbiased nonlinear average age-appropriate brain templates from birth to adulthood
Fonov, V., Evans, A., McKinstry, R., Almli, C., & Collins, D. (2009) · NeuroImage · doi:10.1016/s1053-8119(09)70884-5 · Cited by 2,102
MNE software for processing MEG and EEG data
Gramfort, A., Luessi, M., Larson, E., Engemann, D. A., Strohmeier, D., Brodbeck, C., Parkkonen, L., & Hämäläinen, M. S. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.027 · Cited by 1,951
The five percent electrode system for high-resolution EEG and ERP measurements
Oostenveld, R., & Praamstra, P. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00527-7 · Cited by 1,909
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
Baillet, S., Mosher, J. C., & Leahy, R. M. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962275 · Cited by 1,692
A Probabilistic Atlas of the Human Brain: Theory and Rationale for Its Development
Mazziotta, J. C., Toga, A. W., Evans, A., Fox, P., & Lancaster, J. (1995) · NeuroImage · doi:10.1006/nimg.1995.1012 · Cited by 1,584
3D statistical neuroanatomical models from 305 MRI volumes
Evans, A. C., Collins, D. L., Mills, S. R., Brown, E. D., Kelly, R. L., & Peters, T. M. (2005) · 1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference · doi:10.1109/nssmic.1993.373602 · Cited by 1,487
Enhancement of MR Images Using Registration for Signal Averaging
Holmes, C. J., Hoge, R., Collins, L., Woods, R., Toga, A. W., & Evans, A. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199803000-00032 · Cited by 1,417
Datta, A., Bansal, V., Diaz, J., Patel, J., Reato, D., & Bikson, M. (2009) · Brain Stimulation · doi:10.1016/j.brs.2009.03.005 · Cited by 1,290
Introduction to electrodynamics
CAPRI, A. Z. (2000) · Cited by 1,211
OpenMEEG: opensource software for quasistatic bioelectromagnetics
Gramfort, A., Papadopoulo, T., Olivi, E., & Clerc, M. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-45 · Cited by 1,154
A standardized boundary element method volume conductor model
Fuchs, M., Kastner, J., Wagner, M., Hawes, S., & Ebersole, J. S. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00030-5 · Cited by 999
EEG and MEG: forward solutions for inverse methods
Mosher, J. C., Leahy, R. M., & Lewis, P. S. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.748978 · Cited by 839
Unveiling the Biometric Potential of Finger-Based ECG Signals
Lourenço, A., Silva, H., & Fred, A. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/720971 · Cited by 754
A Survey of Stimulation Methods Used in SSVEP-Based BCIs
Zhu, D., Bieger, J., Garcia Molina, G., & Aarts, R. M. (2010) · Computational Intelligence and Neuroscience · doi:10.1155/2010/702357 · Cited by 654
Optimized multi-electrode stimulation increases focality and intensity at target
Dmochowski, J. P., Datta, A., Bikson, M., Su, Y., & Parra, L. C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046011 · Cited by 590
Self-citationTranscranial direct current stimulation: A computer-based human model study
Wagner, T., Fregni, F., Fecteau, S., Grodzinsky, A., Zahn, M., & Pascual-Leone, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.01.027 · Cited by 567 · cited 1×
“What is called ‘forward model’ in tES captures the electric field generated in the brain when applying current to scalp electrodes (Wagner et al., 2007; Datta et al., 2009, 2012; Mendonca et al., 2011; Dmochowski et al., 2013).”
Symmetric Atlasing and Model Based Segmentation: An Application to the Hippocampus in Older Adults
Grabner, G., Janke, A. L., Budge, M. M., Smith, D., Pruessner, J., & Collins, D. L. (2006) · Lecture Notes in Computer Science · doi:10.1007/11866763_8 · Cited by 549
Edwards, D., Cortes, M., Datta, A., Minhas, P., Wassermann, E. M., & Bikson, M. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.01.042 · Cited by 468
EEG Electrode Sensitivity-An Application of Reciprocity
Rush, S., & Driscoll, D. A. (1969) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1969.4502598 · Cited by 448
Windhoff, M., Opitz, A., & Thielscher, A. (2013) · Human Brain Mapping · doi:10.1002/hbm.21479 · Cited by 441
Datta, A., Truong, D., Minhas, P., Parra, L. C., & Bikson, M. (2012) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2012.00091 · Cited by 404
Self-citationSource localization using recursively applied and projected (RAP) MUSIC
Mosher, J. C., & Leahy, R. M. (1999) · IEEE Transactions on Signal Processing · doi:10.1109/78.740118 · Cited by 398
A study of dipole localization accuracy for MEG and EEG using a human skull phantom
Leahy, R. M., Mosher, J. C., Spencer, M. E., Huang, M. X., & Lewine, J. D. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00057-1 · Cited by 383
A Four-Dimensional Probabilistic Atlas of the Human Brain
Mazziotta, J., Toga, A., Evans, A., Fox, P., Lancaster, J., Zilles, K., Woods, R., Paus, T., Simpson, G., Pike, B., et al. (2001) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.2001.0080401 · Cited by 378
A guideline for head volume conductor modeling in EEG and MEG
Vorwerk, J., Cho, J.-H., Rampp, S., Hamer, H., Knösche, T. R., & Wolters, C. H. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.06.040 · Cited by 302
A new improved version of the realistic digital brain phantom
Aubert-Broche, B., Evans, A. C., & Collins, L. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.03.052 · Cited by 275
Modeling of the human skull in EEG source analysis
Dannhauer, M., Lanfer, B., Wolters, C. H., & Knösche, T. R. (2011) · Human Brain Mapping · doi:10.1002/hbm.21114 · Cited by 268
Effects of Forward Model Errors on EEG Source Localization
Akalin Acar, Z., & Makeig, S. (2013) · Brain Topography · doi:10.1007/s10548-012-0274-6 · Cited by 265
Datta, A., Bikson, M., & Fregni, F. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.04.252 · Cited by 211
Villamar, M. F., Wivatvongvana, P., Patumanond, J., Bikson, M., Truong, D. Q., Datta, A., & Fregni, F. (2013) · The Journal of Pain · doi:10.1016/j.jpain.2012.12.007 · Cited by 194
Investigation of tDCS volume conduction effects in a highly realistic head model
Wagner, S., Rampersad, S. M., Aydin, Ü., Vorwerk, J., Oostendorp, T. F., Neuling, T., Herrmann, C. S., Stegeman, D. F., & Wolters, C. H. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016002 · Cited by 177
Longitudinal Neurostimulation in Older Adults Improves Working Memory
Jones, K. T., Stephens, J. A., Alam, M., Bikson, M., & Berryhill, M. E. (2015) · PLOS ONE · doi:10.1371/journal.pone.0121904 · Cited by 167
Mendonca, M. E., Santana, M. B., Baptista, A. F., Datta, A., Bikson, M., Fregni, F., & Araujo, C. P. (2011) · The Journal of Pain · doi:10.1016/j.jpain.2010.12.015 · Cited by 163
Automated MRI segmentation for individualized modeling of current flow in the human head
Huang, Y., Dmochowski, J. P., Su, Y., Datta, A., Rorden, C., & Parra, L. C. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066004 · Cited by 162
Self-citationTargeted transcranial direct current stimulation for rehabilitation after stroke
Dmochowski, J., Datta, A., Huang, Y., Richardson, J. D., Bikson, M., Fridriksson, J., & Parra, L. C. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.02.049 · Cited by 161
Self-citationNeuroelectromagnetic Forward Head Modeling Toolbox
Acar, Z. A., & Makeig, S. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.04.031 · Cited by 134
Combining sparsity and rotational invariance in EEG/MEG source reconstruction
Haufe, S., Nikulin, V. V., Ziehe, A., Müller, K.-R., & Nolte, G. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.04.246 · Cited by 130 · cited 1×
“…were performed with computationally efficient BEM and spherical harmonics expansions (SHE, (Nolte and Dassios, 2005; Marzetti et al., 2008; Haufe et al., 2008, 2011)) models of the reference anatomy, a BEM of the ICBM152 anatomy, as well as ‘individualized’ BEMs that are adjusted to the…”
Self-citationLarge-scale EEG/MEG source localization with spatial flexibility
Haufe, S., Tomioka, R., Dickhaus, T., Sannelli, C., Blankertz, B., Nolte, G., & Müller, K. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.003 · Cited by 114
Self-citationMedical Image Computing and Computer-Assisted Intervention – MICCAI 2007
Ayache, N., Sebastien Ourselin, A., & Maeder, A. (2007) · Lecture notes in computer science · doi:10.1007/978-3-540-75759-7 · Cited by 110
Jung, Y., Kim, J., & Im, C. (2013) · Biomedical Engineering Letters · doi:10.1007/s13534-013-0087-x · Cited by 106
Salvador, R., Mekonnen, A., Ruffini, G., & Miranda, P. C. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626315 · Cited by 99
Wolters, C. H., Anwander, A., Berti, G., & Hartmann, U. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.890736 · Cited by 98
Determination of optimal electrode positions for transcranial direct current stimulation (tDCS)
Im, C., Jung, H., Choi, J., Lee, S. Y., & Jung, K.-Y. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/11/n03 · Cited by 89
Modeling Skull Electrical Properties
Sadleir, R., & Argibay, A. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9343-5 · Cited by 88
Suh, H. S., Lee, W. H., & Kim, T.-S. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/21/6961 · Cited by 84
Approximate average head models for EEG source imaging
Valdes-Hernandez, P. A., von Ellenrieder, N., Ojeda, A., Kochen, S. S., Alemán‐Gómez, Y., Muravchik, C. H., & Valdes-Sosa, P. A. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.09.005 · Cited by 83
Generic head models for atlas‐based EEG source analysis
Darvas, F., Ermer, J. J., Mosher, J. C., & Leahy, R. M. (2005) · Human Brain Mapping · doi:10.1002/hbm.20171 · Cited by 83
Marzetti, L., Gratta, C. D., & Nolte, G. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.04.250 · Cited by 81
Analytic expansion of the EEG lead field for realistic volume conductors
Nolte, G., & Dassios, G. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/16/010 · Cited by 74
Shahid, S. S., Wen, P. P., & Ahfock, T. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2012.09.001 · Cited by 71
Paired MEG data set source localization using recursively applied and projected (RAP) MUSIC
Ermer, J. J., Mosher, J. C., Huang, M., & Leahy, R. M. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.867959 · Cited by 64
Dannhauer, M., Brooks, D. H., Tucker, D. M., & MacLeod, R. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347236 · Cited by 56
Huang, Y., & Parra, L. C. (2015) · PLoS ONE · doi:10.1371/journal.pone.0125477 · Cited by 47
Self-citation2009 Nuclear science symposium and medical imaging conference
(2009) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2009.5402045 · Cited by 43
Richardson, J. D., Fillmore, P., Datta, A., Truong, D. Q., Bikson, M., & Fridriksson, J. (2014) · NeuroRegulation · doi:10.15540/nr.1.1.62 · Cited by 34
Correction: Longitudinal Neurostimulation in Older Adults Improves Working Memory
Jones, K. T., Stephens, J. A., Alam, M., Bikson, M., & Berryhill, M. E. (2015) · PLoS ONE · doi:10.1371/journal.pone.0129751 · Cited by 32
Simulating pad-electrodes with high-definition arrays in transcranial electric stimulation
Kempe, R., Huang, Y., & Parra, L. C. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026003 · Cited by 30
Self-citation
Cited by
Immediate neurophysiological effects of transcranial electrical stimulation
Liu, A., Vöröslakos, M., Kronberg, G., Henin, S., Krause, M. R., Huang, Y., Opitz, A., Mehta, A., Pack, C. C., Krekelberg, B., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-07233-7 · Cited by 589
Self-citationMethodological considerations for studying neural oscillations
Donoghue, T., Schaworonkow, N., & Voytek, B. (2022) · European Journal of Neuroscience · doi:10.1111/ejn.15361 · Cited by 309
Hagen, E., Næss, S., Ness, T. V., & Einevoll, G. T. (2018) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2018.00092 · Cited by 129
“…that the computed current dipole moments also can be used for subsequent calculation of EEG and MEG signals by means of boundary element (BEM) or finite element models (FEM) with anatomically detailed head models (He et al., 2002; Bangera et al., 2010; DeMunck et al., 2012), (Huang et al., 2016).”
MethodSalehinejad, M. A., Nejati, V., Mosayebi-Samani, M., Mohammadi, A., Wischnewski, M., Kuo, M.-F., Avenanti, A., Vicario, C. M., & Nitsche, M. A. (2020) · Neuroscience Bulletin · doi:10.1007/s12264-020-00501-x · Cited by 118
Biophysically detailed forward modeling of the neural origin of EEG and MEG signals
Næss, S., Halnes, G., Hagen, E., Hagler, D. J., Dale, A. M., Einevoll, G. T., & Ness, T. V. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2020.117467 · Cited by 66
Metadata
- Authors
- Huang, Y., Parra, L. C., & Haufe, S.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2016-10
- Volume
- 140
- Pages
- 150-162
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2207714503
- Cited by
- 259
- References
- 69
- FWCI
- 8.85
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.