Abstract
Optically-pumped magnetometers (OPMs) are highly sensitive, compact magnetic field sensors, which offer a viable alternative to cryogenic sensors (superconducting quantum interference devices - SQUIDs) for magnetoencephalography (MEG). With the promise of a wearable system that offers lifespan compliance, enables movement during scanning, and provides higher quality data, OPMs could drive a step change in MEG instrumentation. However, this potential can only be realised if background magnetic fields are appropriately controlled, via a combination of optimised passive magnetic screening (i.e. enclosing the system in layers of high-permeability materials), and electromagnetic coils to further null the remnant magnetic field. In this work, we show that even in an OPM-optimised passive shield with extremely low (<2 nT) remnant magnetic field, head movement generates significant artefacts in MEG data that manifest as low-frequency interference. To counter this effect we introduce a magnetic field mapping technique, in which the participant moves their head to sample the background magnetic field using a wearable sensor array; resulting data are compared to a model to derive coefficients representing three uniform magnetic field components and five magnetic field gradient components inside the passive shield. We show that this technique accurately reconstructs the magnitude of known magnetic fields. Moreover, by feeding the obtained coefficients into a bi-planar electromagnetic coil system, we were able to reduce the uniform magnetic field experienced by the array from a magnitude of 1.3±0.3 nT to 0.29±0.07 nT. Most importantly, we show that this field compensation generates a five-fold reduction in motion artefact at 0‒2 Hz, in a visual steady-state evoked response experiment using 6 Hz stimulation. We suggest that this technique could be used in future OPM-MEG experiments to improve the quality of data, especially in paradigms seeking to measure low-frequency oscillations, or in experiments where head movement is encouraged.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684 · cited 2×
“MEG offers a high spatial and temporal resolution assessment of neural activity (Baillet, 2017; Hämäläinen et al., 1993) in which the formation and dissolution of networks can be tracked in real time (Baker et al.”
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631 · cited 2×
“…al., 2015 ; Sander et al., 2012 )) and sensor miniaurisation and commercialisation ( Allred et al., 2002 ; Johnson et al., 013 ; Kamada et al., 2015 ; Kominis et al., 2003 ; Mhaskar et al., 2012 ; ander et al., 2012 ; Schwindt et al., 2007 ; Shah and Wakai, 2013 ; heng et al., 2017 ) means that…”
Moving magnetoencephalography towards real-world applications with a wearable system
Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., et al. (2018) · Nature · doi:10.1038/nature26147 · Cited by 1,377 · cited 8×
“…field, a rotation of ~4° would generate sufficient hange in field to take an OPM outside its ± 1.5 nT dynamic range (dened here as a 5% gain error) ( Boto et al., 2018 ; Iivanainen et al., 2019 ). ven if the sensor were to remain working, the resulting magnetic arteact would be much larger in…”
InfluentialSelf-citationHigh-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049 · cited 4×
“For PMs to attain sufficient sensitivity to detect changes in the neuromagetic field, they are operated around a zero-field resonance in the spinxchange relaxation free (SERF) regime ( Allred et al., 2002 ).”
InfluentialMagnetoencephalography for Brain Electrophysiology and Imaging
Baillet, S. (2017) · Nature Neuroscience · doi:10.1038/nn.4504 · Cited by 992
Cohen, D. (1972) · Science · doi:10.1126/science.175.4022.664 · Cited by 785 · cited 2×
“Despite its utility, the current generation of MEG systems is limted due to the use of superconducting quantum interference devices SQUIDs) to detect the neuromagnetic field ( Cohen, 1972 ).”
BackgroundMagnetoencephalography: Evidence of Magnetic Fields Produced by Alpha-Rhythm Currents
Cohen, D. (1968) · Science · doi:10.1126/science.161.3843.784 · Cited by 750
Boto, E., Meyer, S. S., Shah, V., Alem, O., Knappe, S., Kruger, P., Fromhold, T. M., Lim, M., Glover, P. M., Morris, P. G., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.034 · Cited by 471 · cited 4×
“The abilty of OPMs to measure neuromagnetic fields – first shown by Xia et al. 2006) – is now well established (e.g. ( Boto et al., 2017 ; Johnson et al., 010 ; Kamada et al., 2015 ; Sander et al., 2012 )) and sensor miniaurisation and commercialisation ( Allred et al., 2002 ; Johnson et al., 013 ;…”
InfluentialSelf-citationOptically pumped magnetometers: from quantum origins to multi-channel magnetoencephalography
Tierney, T. M., Holmes, N., Mellor, S., López, J. D., Roberts, G., Hill, R. M., Boto, E., Leggett, J., Shah, V., Brookes, M. J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.063 · Cited by 400
Self-citationA compact, high performance atomic magnetometer for biomedical applications
Shah, V. K., & Wakai, R. T. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/8153 · Cited by 322 · cited 2×
“…( Allred et al., 2002 ; Johnson et al., 013 ; Kamada et al., 2015 ; Kominis et al., 2003 ; Mhaskar et al., 2012 ; ander et al., 2012 ; Schwindt et al., 2007 ; Shah and Wakai, 2013 ; heng et al., 2017 ) means that robust, small, and lightweight OPMs can ow be mounted on the scalp surface.”
Self-citationMeasuring MEG Closer to the Brain: Performance of on-Scalp Sensor Arrays
Iivanainen, J., Stenroos, M., & Parkkonen, L. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.048 · Cited by 296 · cited 2×
“This, in turn, limits spatial resolution ( Boto et al., 016 ; Iivanainen et al., 2017 ).”
BackgroundMulti-Channel Whole-Head OPM-MEG: Helmet Design and a Comparison with a Conventional System
Hill, R. M., Boto, E., Rea, M., Holmes, N., Leggett, J., Coles, L. A., Papastavrou, M., Everton, S. K., Hunt, B. A. E., Sims, D., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116995 · Cited by 285
Self-citationOn-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers
Iivanainen, J., Zetter, R., Grön, M., Hakkarainen, K., & Parkkonen, L. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.03.022 · Cited by 269
Holmes, N., Leggett, J., Boto, E., Roberts, G., Hill, R. M., Tierney, T. M., Shah, V., Barnes, G. R., Brookes, M. J., & Bowtell, R. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.07.028 · Cited by 250 · cited 9×
“Bi-planar coils—The two planes of the bi-planar coil system (Holmes et al., 2018) were placed on either side of the participant (Fig.”
BackgroundMethodInfluentialSelf-citationOn the Potential of a New Generation of Magnetometers for MEG: A Beamformer Simulation Study
Boto, E., Bowtell, R., Krüger, P., Fromhold, T. M., Morris, P. G., Meyer, S. S., Barnes, G. R., & Brookes, M. J. (2016) · PLOS ONE · doi:10.1371/journal.pone.0157655 · Cited by 194 · cited 1×
“This, in turn, limits spatial resolution (Boto et al., 2016; Iivanainen et al., 2017).”
Self-citationA tool for functional brain imaging with lifespan compliance
Hill, R. M., Boto, E., Holmes, N., Hartley, C., Seedat, Z. A., Leggett, J., Roberts, G., Shah, V., Tierney, T. M., Woolrich, M. W., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-12486-x · Cited by 180 · cited 4×
“technology, with the promise of a wearable system that adapts to any head shape (Hill et al., 2019), enables movement during scanning (Boto et al.”
InfluentialSelf-citationA microfabricated optically-pumped magnetic gradiometer
Sheng, D., Perry, A. R., Krzyzewski, S. P., Geller, S., Kitching, J., & Knappe, S. (2017) · Applied Physics Letters · doi:10.1063/1.4974349 · Cited by 179 · cited 1×
“, 2012)) and sensor miniaturisation and commercialisation (Allred et al., 2002; Johnson et al., 2013; Kamada et al., 2015; Kominis et al., 2003; Mhaskar et al., 2012; Sander et al., 2012; Schwindt et al., 2007; Shah and Wakai, 2013; Sheng et al., 2017) means that robust, small, and lightweight OPMs can now be mounted…”
BackgroundHolmes, N., Tierney, T. M., Leggett, J., Boto, E., Mellor, S., Roberts, G., Hill, R. M., Shah, V., Barnes, G. R., Brookes, M. J., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-50697-w · Cited by 163 · cited 11×
“…generated at he helmet by pulsing a coil with a unit voltage generated by the DAQ. s expected, each coil maps almost exclusively to a different component n our field model, but with some small, off-diagonal elements that are ikely caused by field interactions with the MSR ( Holmes et al., 2019 ).”
BackgroundMethodInfluentialSelf-citationNon-Invasive Functional-Brain-Imaging with an OPM-based Magnetoencephalography System
Borna, A., Carter, T. R., Colombo, A. P., Jau, Y.-Y., McKay, J., Weisend, M., Taulu, S., Stephen, J. M., & Schwindt, P. D. D. (2020) · PLOS ONE · doi:10.1371/journal.pone.0227684 · Cited by 158
Wearable neuroimaging: Combining and contrasting magnetoencephalography and electroencephalography
Boto, E., Seedat, Z. A., Holmes, N., Leggett, J., Hill, R. M., Roberts, G., Shah, V., Fromhold, T. M., Mullinger, K. J., Tierney, T. M., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116099 · Cited by 136
Self-citationTowards OPM-MEG in a Virtual Reality Environment
Roberts, G., Holmes, N., Alexander, N., Boto, E., Leggett, J., Hill, R. M., Shah, V., Rea, M., Vaughan, R., Maguire, E. A., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.06.010 · Cited by 128 · cited 3×
“…1 Hz has also been demonstrated using a high-speed eedback controller to modulate the coil currents ( Holmes et al., 2019 ). hese bi-planar coil systems have proved effective, allowing OPM-MEG tudies to be carried out in freely moving participants (e.g. ( Hill et al., 019 ; Roberts et al., 2019 )).”
MethodSelf-citationMinimizing magnetic fields for precision experiments
Altarev, I., Fierlinger, P., Lins, T., Marino, M. G., Nießen, B., Petzoldt, G., Reisner, M., Stuiber, S., Sturm, M., Taggart Singh, J., et al. (2015) · Journal of Applied Physics · doi:10.1063/1.4922671 · Cited by 66 · cited 3×
“When driven with a linearly decaying sinusoidal current, these oils force the mu-metal around its hysteresis curve towards a point of ero magnetisation ( Altarev et al., 2015 , 2014 ; Voigt et al., 2013 ).”
Voigt, J., Knappe-Grüneberg, S., Schnabel, A., Körber, R., & Burghoff, M. (2013) · Metrology and Measurement Systems · doi:10.2478/mms-2013-0021 · Cited by 50
Cited by
Quantum sensors for biomedical applications
Aslam, N., Zhou, H., Urbach, E. K., Turner, M. J., Walsworth, R. L., Lukin, M. D., & Park, H. (2023) · Nature Reviews Physics · doi:10.1038/s42254-023-00558-3 · Cited by 527
Brookes, M. J., Leggett, J., Rea, M., Hill, R. M., Holmes, N., Boto, E., & Bowtell, R. (2022) · Trends in Neurosciences · doi:10.1016/j.tins.2022.05.008 · Cited by 412
Self-citationFeys, O., Corvilain, P., Aeby, A., Sculier, C., Holmes, N., Brookes, M., Goldman, S., Wens, V., & De Tiège, X. (2022) · Radiology · doi:10.1148/radiol.212453 · Cited by 144
“Movement-related artifacts in OPM signals could be reduced with extra hardware solutions, such as field nulling coils (4) in the magnetically shielded room (to reduce its background field ,1 nT and consequently reduce movement artifacts) and OPM denoising algorithms (18,19).”
Self-citationA lightweight magnetically shielded room with active shielding
Holmes, N., Rea, M., Chalmers, J., Leggett, J., Edwards, L. J., Nell, P., Pink, S., Patel, P., Wood, J., Murby, N., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-17346-1 · Cited by 121
Self-citationA 90-Channel Triaxial Magnetoencephalography System Using Optically Pumped Magnetometers
Rea, M., Boto, E., Holmes, N., Hill, R., Osborne, J., Rhodes, N., Leggett, J., Rier, L., Bowtell, R., Shah, V., et al. (2022) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.14890 · Cited by 102
Self-citation
Metadata
- Authors
- Rea, M., Holmes, N., Hill, R. M., Boto, E., Leggett, J., Edwards, L. J., Woolger, D., Dawson, E., Shah, V., Osborne, J., Bowtell, R., & Brookes, M. J.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2021-11
- Volume
- 241
- Pages
- 118401
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W3183389039
- Cited by
- 118
- References
- 23
- FWCI
- 8.11
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.