Functional Electrical Stimulation and Spinal Cord Injury
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Synopsis Spinal cord injuries (SCI) can disrupt communications between the brain and the body, leading to a loss of control over otherwise intact neuromuscular systems. The use of electrical stimulation (ES) of the central and peripheral nervous system can take advantage of these intact neuromuscular systems to provide therapeutic exercise options, to allow functional restoration, and even to manage or prevent many medical complications following SCI. The use of ES for the restoration of upper extremity, lower extremity and truncal functions can make many activities of daily living a potential reality for individuals with SCI. Restoring bladder and respiratory functions and preventing pressure ulcers may significantly decrease the morbidity and mortality following SCI. Many of the ES devices are already commercially available and should be considered by all SCI clinicians routinely as part of the lifelong rehabilitation care plan for all eligible individuals with SCI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Targeting Recovery: Priorities of the Spinal Cord-Injured Population
Anderson, K. D. (2004) · Journal of Neurotrauma · doi:10.1089/neu.2004.21.1371 · Cited by 2,094 · cited 3×
“bladder function restoration among the highest priority for restoration, more than standing and ambulation.(15) Persons with SCI frequently report ineffectiveness with existing bladder management, medication side effects, challenges associated with bladder catheterization”
BackgroundInfluentialImplanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488 · cited 1×
“Beyond this, several strategies have been undertaken to modify the surface properties of electrodes to improve the interactions that take place with surrounding tissue and reduce glial scar formation.(14) When developing new electrodes, arrays, and coatings, in vitro testing may be used initially to screen the cellula…”
MethodA spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398 · cited 1×
“Electrodes have been designed to wrap around individual nerves, with a range of geometries, including spiral,(4) helical,(5) and rectangular.(6) To selectively address smaller groups of axons within a nerve and to reach areas that are not readily accessible from the surface, intrafascicular electrodes may be inserted…”
BackgroundPeckham, P. H., Keith, M. W., Kilgore, K. L., Grill, J. H., Wuolle, K. S., Thrope, G. B., Gorman, P., Hobby, J., Mulcahey, M. J., Carroll, S., et al. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.25910 · Cited by 319 · cited 1×
“thesis was the Freehand trial, initiated by the Cleveland Functional Electrical Stimulation Center in 1992.(22) The Freehand neuroprosthesis used an implanted 8-channel receiver-stimulator, and control of grasp opening and closing was achieved through graded elevation of the user’s contralateral shoulder.”
MethodSelf-citationCriteria for the Selection of Materials for Implanted Electrodes
Geddes, L. A., & Roeder, R. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1581292 · Cited by 240 · cited 1×
“Other metals (including silver, iron, and copper) are known to elicit dramatic inflammatory response in vivo and should be avoided.(11) The time-dependent failure of neural interfaces in vivo is an impediment to long-term use, particularly for recording electrodes and stimulating electrodes, which inject”
BackgroundAgnew, W. F., McCreery, D. B., Yuen, T. G. H., & Bullara, L. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02364272 · Cited by 185
An implant to empty the bladder or close the urethra.
Brindley, G. S. (1977) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.40.4.358 · Cited by 177
Kobetic, R., Sharma, M., Triolo, R. J., Uhlir, J. P., Bieri, C., Wibowo, M., Polando, G., Marsolais, E. B., Davis, J. A., & Ferguson, K. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.808942 · Cited by 155 · cited 1×
“Stepping of up to 100m has also been achieved after paralysis with simple preprogrammed patterns of open-loop stimulation delivered from the surface or via 8- and 16-channel implanted pulse generators.(36) Once initiated by the user, steppingmotions can cycle continuously while the appropriate adjustments are made wit…”
MethodSelf-citationA slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves
Tyler, D. J., & Durand, D. M. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559349 · Cited by 108 · cited 1×
“To selectively address smaller groups of axons within a nerve and to reach areas that are not readily accessible from the surface, intrafascicular electrodes may be inserted into the nerve itself.(7) Pools of”
BackgroundControl of urinary bladder function with devices: successes and failures
Gaunt, R. A., & Prochazka, A. (2006) · Progress in Brain Research · doi:10.1016/s0079-6123(05)52011-9 · Cited by 105 · cited 1×
“FES offers a means to restore LUT function by activating the bladder and inhibiting the urethral sphincter to produce voiding or by inhibiting the bladder to provide urinary continence and reduce triggers for AD and restore LUT function.(73) The Brindley approach was the first widely clinically available FES system fo…”
BackgroundStanding After Spinal Cord Injury With Four-Contact Nerve-Cuff Electrodes for Quadriceps Stimulation
Fisher, L. E., Miller, M. E., Bailey, S. N., Davis Jr., J. A., Anderson, J. S., Rhode, L., Tyler, D. J., & Triolo, R. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2003390 · Cited by 90 · cited 1×
“uous stimulation of the femoral nerve with a multicontact cuff electrode below the branches to the rectus femoris and sartorius was shown to extend standing time and accelerate progress through reconditioning rehabilitation and balance training with the system.(44) The potential to delay the effects of fatigue by alte…”
BackgroundSelf-citationSatisfaction with and usage of a hand neuroprosthesis
Wuolle, K. S., Van Doren, C. L., Bryden, A. M., Hunter Peckham, P., Keith, M. W., Kilgore, K. L., & Grill, J. H. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90123-5 · Cited by 70
Self-citationFunctional Electrical Stimulation For Walking In Paraplegia: 17-Year Follow-Up Of 2 Cases
Agarwal, S., Kobetic, R., Nandurkar, S., & Marsolais, E. B. (2003) · The Journal of Spinal Cord Medicine · doi:10.1080/10790268.2003.11753666 · Cited by 49 · cited 1×
“implanted systems, although subcutaneous electrodes themselves can remain functional for years.(3) When electrodes are fully implanted in close proximity to the nerve,”
BackgroundSelf-citationOptimization of selective stimulation parameters for multi-contact electrodes
Fisher, L. E., Tyler, D. J., & Triolo, R. J. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-25 · Cited by 45 · cited 1×
“The potential to delay the effects of fatigue by alternating activation of independent motor unit pools within a muscle via multicontact nerve cuffs or multiple independent nerve- or muscle-based electrodes is also being investigated.(45) At present, neuroprostheses are generally unresponsive to environmental disturba…”
BackgroundSelf-citation
Cited by
Ahuja, C. S., Wilson, J. R., Nori, S., Kotter, M. R. N., Druschel, C., Curt, A., & Fehlings, M. G. (2017) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2017.18 · Cited by 2,441
A brain–spine interface alleviating gait deficits after spinal cord injury in primates
Capogrosso, M., Milekovic, T., Borton, D., Wagner, F., Moraud, E. M., Mignardot, J.-B., Buse, N., Gandar, J., Barraud, Q., Xing, D., et al. (2016) · Nature · doi:10.1038/nature20118 · Cited by 635
Badhiwala, J. H., Ahuja, C. S., & Fehlings, M. G. (2019) · Journal of Neurosurgery: Spine · doi:10.3171/2018.9.spine18682 · Cited by 288
Soekadar, S. R., Witkowski, M., Gómez, C., Opisso, E., Medina, J., Cortese, M., Cempini, M., Carrozza, M. C., Cohen, L. G., Birbaumer, N., et al. (2016) · Science Robotics · doi:10.1126/scirobotics.aag3296 · Cited by 242
Metadata
- Authors
- Ho, C. H., Triolo, R. J., Elias, A. L., Kilgore, K. L., DiMarco, A. F., Bogie, K., Vette, A. H., Audu, M. L., Kobetic, R., Chang, S. R., Chan, K. M., Dukelow, S., Bourbeau, D. J., Brose, S. W., Gustafson, K. J., Kiss, Z. H. T., & Mushahwar, V. K.
- Venue
- Physical Medicine and Rehabilitation Clinics of North America
- Publisher
- Elsevier BV
- Published
- 2014-08
- Volume
- 25
- Issue
- 3
- Pages
- 631-654
- ISSN
- 1047-9651 (ISSN-L)
- OpenAlex
- W1973929645
- Cited by
- 203
- References
- 16
- FWCI
- 8.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.