On-chip highly sensitive saliva glucose sensing using multilayer films composed of single-walled carbon nanotubes, gold nanoparticles, and glucose oxidase
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
It is very important for human health to rapidly and accurately detect glucose levels in biological environments, especially for diabetes mellitus. We proposed a simple, highly sensitive, accurate, convenient, low-cost, and disposable glucose biosensor on a single chip. A working (sensor) electrode, a counter electrode, and a reference electrode are integrated on a single chip through micro-fabrication. The working electrode is functionalized through a layer-by-layer (LBL) assembly of single-walled carbon nanotubes (SWNTs) and multilayer films composed of chitosan (CS), gold nanoparticles (GNp), and glucose oxidase (GOx) to obtain high sensitivity and accuracy. The glucose sensor has following features: (1) direct electron transfer between GOx and the electrode surface; (2) on-a-chip; (3) glucose detection down to 0.1 mg/dL (5.6 μM); (4) good sensing linearity over 0.017–0.81 mM; (5) high sensitivity (61.4 μA/mM-cm 2 ) with a small reactive area (8 mm 2 ); (6) fast response; (7) high reproducibility and repeatability; (8) reliable and accurate saliva glucose detection. Thus, this disposable biosensor will be an alternative for real time tracking of glucose levels from body fluids, e.g. saliva, in a noninvasive, pain-free, accurate, and continuous way. In addition to being used as a disposable glucose biosensor, it also provides a suitable platform for on-chip electrochemical sensing for other chemical agents and biomolecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Glucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285
Noninvasive glucose monitoring using saliva nano-biosensor
Zhang, W., Du, Y., & Wang, M. L. (2015) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2015.02.002 · Cited by 232
Self-citationSalivary Glucose Concentration and Excretion in Normal and Diabetic Subjects
Jurysta, C., Bulur, N., Oguzhan, B., Satman, I., Yilmaz, T. M., Malaisse, W. J., & Sener, A. (2009) · BioMed Research International · doi:10.1155/2009/430426 · Cited by 198
Noninvasively measuring blood glucose using saliva
Yamaguchi, M., Mitsumori, M., & Kano, Y. (1998) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.677170 · Cited by 129
Validity of Urine Glucose Measurements for Estimating Plasma Glucose Concentration
Hayford, J. T., Weydert, J. A., & Thompson, R. G. (1983) · Diabetes Care · doi:10.2337/diacare.6.1.40 · Cited by 45
Cited by
Glucose Sensing for Diabetes Monitoring: Recent Developments
Bruen, D., Delaney, C., Florea, L., & Diamond, D. (2017) · Sensors · doi:10.3390/s17081866 · Cited by 777
Accessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Mouthguard biosensor with telemetry system for monitoring of saliva glucose: A novel cavitas sensor
Arakawa, T., Kuroki, Y., Nitta, H., Chouhan, P., Toma, K., Sawada, S.-I., Takeuchi, S., Sekita, T., Akiyoshi, K., Minakuchi, S., et al. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.12.014 · Cited by 356
Adeel, M., Rahman, M. M., Caligiuri, I., Canzonieri, V., Rizzolio, F., & Daniele, S. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112331 · Cited by 327
Metadata
- Authors
- Zhang, W., Du, Y., & Wang, M. L.
- Venue
- Sensing and Bio-Sensing Research
- Publisher
- Elsevier BV
- Published
- 2015-06
- Volume
- 4
- Pages
- 96-102
- ISSN
- 2214-1804 (ISSN-L)
- OpenAlex
- W261424708
- Cited by
- 94
- References
- 6
- FWCI
- 4.01
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On-chip highly sensitive saliva glucose sensing using multilayer films composed of single-walled carbon nanotubes, gold nanoparticles, and glucose oxidase. https://app.cochat.ai/papers/10.1016/j.sbsr.2015.04.006
- The paper
- Zhang, W., Du, Y., & Wang, M. L. (2015). On-chip highly sensitive saliva glucose sensing using multilayer films composed of single-walled carbon nanotubes, gold nanoparticles, and glucose oxidase. Sensing and Bio-Sensing Research. https://doi.org/10.1016/j.sbsr.2015.04.006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.