NIR-II fluorescence in vivo confocal microscopy with aggregation-induced emission dots
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Significantly reduced tissue scattering of fluorescence signals in the second near-infrared (NIR-II, 1,000-1,700 nm) spectral region offers opportunities for large-depth in vivo bioimaging. Nowadays, most reported works concerning NIR-II fluorescence in vivo bioimaging are realized by wide-field illumination and 2D-arrayed detection (e.g., via InGaAs camera), which has high temporal resolution but limited spatial resolution due to out-of-focus signals. Combining NIR-II fluorescence imaging with confocal microscopy is a good approach to achieve high-spatial resolution visualization of biosamples even at deep tissues. In this presented work, a NIR-II fluorescence confocal microscopic system was setup. By using a kind of aggregation-induced emission (AIE) dots as NIR-II fluorescent probes, 800 μm-deep 3D in vivo cerebrovascular imaging of a mouse was obtained, and the spatial resolution at 700 μm depth could reach 8.78 μm. Moreover, the time-correlated single photon counting (TCSPC) technique and femtosecond laser excitation were introduced into NIR-II fluorescence confocal microscopy, and in vivo confocal NIR-II fluorescence lifetime microscopic imaging (FLIM) of mouse cerebral vasculature was successfully realized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
Multifunctional in vivo vascular imaging using near-infrared II fluorescence
Hong, G., Lee, J. C., Robinson, J. T., Raaz, U., Xie, L., Huang, N. F., Cooke, J. P., & Dai, H. (2012) · Nature Medicine · doi:10.1038/nm.2995 · Cited by 995
Biodegradable triboelectric nanogenerator as a life-time designed implantable power source
Zheng, Q., Zou, Y., Zhang, Y., Liu, Z., Shi, B., Wang, X., Jin, Y., Ouyang, H., Li, Z., & Wang, Z. L. (2016) · Science Advances · doi:10.1126/sciadv.1501478 · Cited by 617
In Vivo Powering of Pacemaker by Breathing‐Driven Implanted Triboelectric Nanogenerator
Zheng, Q., Shi, B., Fan, F., Wang, X., Yan, L., Yuan, W., Wang, S., Liu, H., Li, Z., & Wang, Z. L. (2014) · Advanced Materials · doi:10.1002/adma.201402064 · Cited by 603
Hong, G., Zou, Y., Antaris, A. L., Diao, S., Wu, D., Cheng, K., Zhang, X., Chen, C., Liu, B., He, Y., et al. (2014) · Nature Communications · doi:10.1038/ncomms5206 · Cited by 563
A bright organic NIR-II nanofluorophore for three-dimensional imaging into biological tissues
Wan, H., Yue, J., Zhu, S., Uno, T., Zhang, X., Yang, Q., Yu, K., Hong, G., Wang, J., Li, L., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-03505-4 · Cited by 450
Sheng, Z., Guo, B., Hu, D., Xu, S., Wu, W., Liew, W. H., Yao, K., Jiang, J., Liu, C., Zheng, H., et al. (2018) · Advanced Materials · doi:10.1002/adma.201800766 · Cited by 445
Self-citationMuscle‐Driven In Vivo Nanogenerator
Li, Z., Zhu, G., Yang, R., Wang, A. C., & Wang, Z. L. (2010) · Advanced Materials · doi:10.1002/adma.200904355 · Cited by 441
Qi, J., Sun, C., Zebibula, A., Zhang, H., Kwok, R. T. K., Zhao, X., Xi, W., Lam, J. W. Y., Qian, J., & Tang, B. Z. (2018) · Advanced Materials · doi:10.1002/adma.201706856 · Cited by 418
Self-citation
Cited by
In vivo NIR-II fluorescence imaging for biology and medicine
Wang, F., Zhong, Y., Bruns, O., Liang, Y., & Dai, H. (2024) · Nature Photonics · doi:10.1038/s41566-024-01391-5 · Cited by 564
“Confocal imaging of aggregation-induced emission (AIE) dots-filled cerebral blood vessels after craniotomy was performed using 793-nm excitation and >1,000 nm emission, and achieved an 800-μm penetration depth in mouse brain with ~9-μm resolution 74 .”
NIR‐II AIEgens: A Win–Win Integration towards Bioapplications
Xu, W., Wang, D., & Tang, B. Z. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202005899 · Cited by 457
Perfecting and extending the near-infrared imaging window
Feng, Z., Tang, T., Wu, T., Yu, X., Zhang, Y., Wang, M., Zheng, J., Ying, Y., Chen, S., Zhou, J., et al. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00628-0 · Cited by 394
Self-citationNIR-II light in clinical oncology: opportunities and challenges
Zhang, Z., Du, Y., Shi, X., Wang, K., Qu, Q., Liang, Q., Ma, X., He, K., Chi, C., Tang, J., et al. (2024) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-024-00892-0 · Cited by 341
Aggregation-induced emission: a coming-of-age ceremony at the age of eighteen
Yang, J., Chi, Z., Zhu, W., Tang, B. Z., & Li, Z. (2019) · Science China Chemistry · doi:10.1007/s11426-019-9512-x · Cited by 324
Metadata
- Authors
- Yu, W., Guo, B., Zhang, H., Zhou, J., Yu, X., Zhu, L., Xue, D., Liu, W., Sun, X., & Qian, J.
- Venue
- Science Bulletin
- Publisher
- Elsevier BV
- Published
- 2019-03
- Volume
- 64
- Issue
- 6
- Pages
- 410-416
- ISSN
- 2095-9273 (ISSN-L)
- OpenAlex
- W2916688643
- Cited by
- 85
- References
- 9
- FWCI
- 7.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: NIR-II fluorescence in vivo confocal microscopy with aggregation-induced emission dots. https://app.cochat.ai/papers/10.1016/j.scib.2019.02.019
- The paper
- Yu, W., Guo, B., Zhang, H., Zhou, J., Yu, X., Zhu, L., Xue, D., Liu, W., Sun, X., & Qian, J. (2019). NIR-II fluorescence in vivo confocal microscopy with aggregation-induced emission dots. Science Bulletin. https://doi.org/10.1016/j.scib.2019.02.019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.