The DOI matches its Crossref record; 18 of the 19 references it cites were found in a registry or an index.
X-Ray Scattering Used to Map the Preferred Collagen Orientation in the Human Cornea and Limbus
Open accessAbstract
Many properties of connective tissues are governed by the organization of the constituent collagen. For example, the organization of collagen in the cornea and the limbus, where the cornea and sclera meet, is an important determinant of corneal curvature and hence of the eye's focusing power. We have used synchrotron X-ray scattering to map the orientation of the collagen fibrils throughout the human cornea, limbus, and adjacent sclera. We demonstrate a preferred orientation of collagen in the vertical and horizontal directions that is maintained to within about 1 mm from the limbus, where a circular or tangential disposition of fibrils occurs. The data are also used to map the relative distribution of both the total and the preferentially aligned collagen in different parts of the tissue, revealing considerable anisotropy. The detailed structural information provided is an important step toward understanding the shape and the mechanical properties of the tissue.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Maurice and colleagues initially employed X‐rays to investigate structural features pertaining to the arrangement of collagen fibers in corneal tissues, enabling the quantification of the orientation and content of collagen fibers across the cornea and limbus, with changes in fiber arrangement being readily detected via X‐ray scattering patterns.[ 94 , 105 , 111 ]”
From Bioactive scaffolds for tissue engineering: A review of decellularized extracellular matrix applications and innovations (2025) · cites this paper as [111]
In the citing paper
“although water distribution from central cornea to limbus is not known for human corneas, it seems likely that alterations in tissue thickness are due to an increase in the amount of collagen in the peripheral stroma (Aghamohammadzadeh et al., 2004, Boote et al., 2011, Henriksson et al., 2012).”
From Corneal structure and transparency (2015) · cites this paper as Aghamohammadzadeh et al., 2004
In the citing paper
“Collagen lamellae in the deeper stroma (Fig. 1a) have preferred directions, which appear to be close to the inferior-superior and nasal-temporal directions (Meek et al., 1987, Aghamohammadzadeh et al., 2004, Abahussin et al., 2009, Kamma-Lorger et al., 2010).”
From Corneal structure and transparency (2015) · cites this paper as Aghamohammadzadeh et al., 2004
In the citing paper
“X-ray scattering has also suggested the presence of a network of collagen lamellae that enter the cornea close to the inferior, superior, nasal and temporal positions, and which probably originate in the adjacent sclera (Aghamohammadzadeh et al., 2004).”
From Corneal structure and transparency (2015) · cites this paper as Aghamohammadzadeh et al., 2004
In the citing paper
“X-ray scattering has shown that the lamellae have preferred orientations in the human cornea: inferior-superior and nasal-temporal in the central cornea and circumferential at the limbus.”
From Structural control of corneal transparency, refractive power and dynamics (2025) · cites this paper as [13]
In the citing paper
“Throughout the optical zone, there is a preference for lamellae to run in the inferior-superior and temporal-nasal directions.”
From Structural control of corneal transparency, refractive power and dynamics (2025) · cites this paper as [13]
Citations
Cites
Principles and Practice of Ophthalmology
(1981) · American Journal of Ophthalmology · doi:10.1016/0002-9394(81)90081-7 · Cited by 1,073
Maurice, D. M. (1962) · Elsevier eBooks · doi:10.1016/b978-1-4832-3090-0.50013-7 · Cited by 436
Principles and Practice of Ophthalmology,
Tessler, H. H. (2000) · Survey of Ophthalmology · doi:10.1016/s0039-6257(00)00166-1 · Cited by 409
(1997) · PubMed · Cited by 326
The organization of collagen in the corneal stroma
Meek, K. M., & Boote, C. (2003) · Experimental Eye Research · doi:10.1016/j.exer.2003.07.003 · Cited by 297
Self-citationRegional elastic performance of the human cornea
Hjortdal, J. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00152-2 · Cited by 233
Meek, K. M., Blamires, T., Elliott, G. F., Gyi, T. J., & Nave, C. (1987) · Current Eye Research · doi:10.3109/02713688709034853 · Cited by 161
Self-citationInterlacing and cross-angle distribution of collagen lamellae in the human cornea
Radner, W., Zehetmayer, M., Aufreiter, R., & Mallinger, R. (1998) · Cornea · doi:10.1097/00003226-199809000-00012 · Cited by 153
The use of X-ray scattering techniques to determine corneal ultrastructure
Meek, K. M., & Quantock, A. J. (2001) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(00)00016-1 · Cited by 139
Self-citation(1998) · PubMed · Cited by 111
Self-citation
Cited by
Sorted by citations
Items 101–200 of 233
3D Microfabricated Scaffolds and Microfluidic Devices for Ocular Surface Replacement: a Review
Prina, E., Mistry, P., Sidney, L. E., Yang, J., Wildman, R. D., Bertolin, M., Breda, C., Ferrari, B., Barbaro, V., Hopkinson, A., et al. (2017) · Stem Cell Reviews and Reports · doi:10.1007/s12015-017-9740-6 · Cited by 23
Biomechanical Modeling of Femtosecond Laser Keyhole Endokeratophakia Surgery
Studer, H. P., Pradhan, K. R., Reinstein, D. Z., Businaro, E., Archer, T. J., Gobbé, M., & Roberts, C. J. (2015) · Journal of Refractive Surgery · doi:10.3928/1081597x-20150623-07 · Cited by 22
Fibril density reduction in keratoconic corneas
Zhou, D., Abass, A., Lopes, B. T., Eliasy, A., Hayes, S., Boote, C., Meek, K. M., Movchan, A. B., Movchan, N. V., & Elsheikh, A. (2021) · Journal of The Royal Society Interface · doi:10.1098/rsif.2020.0900 · Cited by 21
Self-citationBoote, C., Dooley, E. P., Gardner, S. J., Kamma-Lorger, C. S., Hayes, S., Nielsen, K., Hjortdal, J., Sorensen, T., Terrill, N. J., & Meek, K. M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0068166 · Cited by 21
Self-citationAmini, R., Voycheck, C. A., & Debski, R. E. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4026105 · Cited by 21
Corneal tissue properties following scleral lens wear using Scheimpflug imaging
Consejo, A., Alonso‐Caneiro, D., Wojtkowski, M., & Vincent, S. J. (2020) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12710 · Cited by 21
Ruberti, J. W., Zieske, J. D., & Trinkaus‐Randall, V. (2007) · Elsevier eBooks · doi:10.1016/b978-012370615-7/50072-x · Cited by 21
Giraudet, C., Diaz, J., Tallec, P. L., & Allain, J. (2022) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2022.105121 · Cited by 19
Preferred orientation and its effects on intensity-correlation measurements
Binns, J., Darmanin, C., Kewish, C. M., Pathirannahalage, S. K., Berntsen, P., Adams, P., Paporakis, S., Wells, D., Roque, F. G., Abbey, B., et al. (2022) · IUCrJ · doi:10.1107/s2052252521012422 · Cited by 19
Second Harmonic Generation for Visualizing 3-Dimensional Structure of Corneal Collagen Lamellae
Morishige, N., Nishida, T., & Jester, J. V. (2009) · Cornea · doi:10.1097/ico.0b013e3181ae9f37 · Cited by 19
The influence of the geometry of the porcine cornea on the biomechanical response of inflation tests
Pandolfi, A. M., & Boschetti, F. (2013) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2013.778983 · Cited by 19
Navarro, R., Palos, F., Lanchares, E., Calvo, B., & Cristóbal, J. Á. (2008) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2008.09.015 · Cited by 19
Mechanics and spiral formation in the rat cornea
Nejad, T. M., Iannaccone, S., Rutherford, W., Iannaccone, P. M., & Foster, C. D. (2014) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-014-0592-6 · Cited by 18
Changes in Corneal Collagen Architecture during Mouse Postnatal Development
Sheppard, J., Hayes, S., Boote, C., Votruba, M., & Meek, K. M. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.09-4612 · Cited by 18
Self-citationEffects on collagen orientation in the cornea after trephine injury.
Kamma‐Lorger, C. S., Hayes, S., Boote, C., Burghammer, M. C., Boulton, M. E., & Meek, K. M. (2009) · PubMed Central · Cited by 18
Self-citationQuantization of collagen organization in the stroma with a new order coefficient
Germann, J. A., Martínez-Enríquez, E., & Marcos, S. C. (2017) · Biomedical Optics Express · doi:10.1364/boe.9.000173 · Cited by 18
Corneal Scheimpflug Densitometry in Photorefractive Keratectomy Candidates
Pakbin, M., Khabazkhoob, M., Pakravan, M., Fotouhi, A., Jafarzadehpur, E., Aghamirsalim, M., & Hashemi, H. (2020) · Cornea · doi:10.1097/ico.0000000000002468 · Cited by 18
Ophthalmic findings in patients with arterial tortuosity syndrome and carriers: A case series
Hardin, J. S., Zárate, Y. A., Callewaert, B. L., Phillips, P. H., & Warner, D. B. (2017) · Ophthalmic Genetics · doi:10.1080/13816810.2017.1335332 · Cited by 18
Patil, R. P., Shetty, R., Narasimhan, R., Patel, Y., Khamar, P. M., Pircher, M., Hitzenberger, C. K. F., Nuijts, R. M. M. A., & Roy, A. S. (2022) · Journal of Cataract & Refractive Surgery · doi:10.1097/j.jcrs.0000000000000898 · Cited by 17
Li, J., Ma, H., Zhao, Z., Hou, C., Shao, Y., Waller, S. G., & Chen, W. (2014) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2013-304199 · Cited by 17
A structural investigation of corneal graft failure in suspected recurrent keratoconus
Hayes, S., Young, R., Boote, C., Hawksworth, N. R., Huang, Y., & Meek, K. M. (2009) · Eye · doi:10.1038/eye.2009.159 · Cited by 16
Self-citationCreane, A., Maher, E., Sultan, S., Hynes, N., Kelly, D. J., & Lally, C. (2011) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-011-0358-3 · Cited by 16
Wu, C.-B., Li, S. Y., Lo, A., Ngan, A. H. W., Wong, D., So, K., Ellis-Behnke, R. G., & Tang, B. H. (2013) · Soft Materials · doi:10.1080/1539445x.2011.622030 · Cited by 15
Zhou, D., Eliasy, A., Abass, A., Markov, P., Whitford, C., Boote, C., Movchan, A. B., Movchan, N. V., & Elsheikh, A. (2019) · PLoS ONE · doi:10.1371/journal.pone.0214770 · Cited by 15
Caruso, C., Epstein, R. L., Troiano, P., Ostacolo, C., Barbaro, G., Pacente, L., Bartollino, S., & Costagliola, C. (2019) · Cornea · doi:10.1097/ico.0000000000002088 · Cited by 15
Yao, G., & Duan, D. (2019) · Experimental Biology and Medicine · doi:10.1177/1535370219894332 · Cited by 15
Finite Element Model of Cornea Deformation
Crouch, J. R., Merriam, J. C., & Crouch, E. R. (2005) · Lecture notes in computer science · doi:10.1007/11566489_73 · Cited by 14
Low Energy Blue Pulsed Light‐Activated Injectable Materials for Restoring Thinning Corneas
MacAdam, A. J., Muñoz, M. A., Hage, J. E., Hu, K., Ross, A., Chandra, A., Edwards, J. D., Shahid, Z., Mourcos, S., Comtois‐Bona, M., et al. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202302721 · Cited by 13
New Details of the Human Corneal Limbus Revealed With Second Harmonic Generation Imaging
Park, C. Y., Lee, J. K., Zhang, C., & Chuck, R. S. H. (2015) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.15-16783 · Cited by 13
Wei, Y., Xu, L., & Song, H. (2017) · Experimental and Therapeutic Medicine · doi:10.3892/etm.2017.4675 · Cited by 13
In vivo measurement of regional corneal tangent modulus
Hon, Y., Chen, G.-Z., Lu, S., LAM, D. C. C., & Lam, A. K. C. (2017) · Scientific Reports · doi:10.1038/s41598-017-14750-w · Cited by 13
Asher, R., Gefen, A., Moisseiev, E., & Varssano, D. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1147-9 · Cited by 12
Interference figures of polarimetric interferometry analysis of the human corneal stroma
Mastropasqua, R., Nubile, M., Salgari, N., Lanzini, M., Calienno, R., Mattei, P. A., Sborgia, A., & Agnifili, L. (2017) · PLoS ONE · doi:10.1371/journal.pone.0178397 · Cited by 12
Is there any objective and independent characterization and modeling of soft biological tissues?
Morch, A., Astruc, L., Mayeur, O., Witz, J., Lecomte‐Grosbras, P., & Brieu, M. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103915 · Cited by 12
Multi-physics modeling and finite element formulation of corneal UV cross-linking
Wang, S., & Chester, S. A. (2021) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-021-01463-3 · Cited by 12
Glaucoma and Structure-Based Mechanics of the Lamina Cribrosa at Multiple Scales
Grytz, R., Meschke, G., Jonas, J. B., & Downs, J. C. (2016) · Springer eBooks · doi:10.1007/978-1-4899-7630-7_6 · Cited by 12
Effect of material properties of the eyeball coat on optical image stability
Srodka, W., & Pierscionek, B. K. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2975844 · Cited by 12
Central versus peripheral thickness in the human cornea explained
Bergmanson, J. P. G., Burns, A. R., & Walker, M. K. (2024) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2024.102165 · Cited by 11
On the recovery of the stress-free configuration of the human cornea
Pandolfi, A. M., & Montanino, A. (2020) · Modeling and Artificial Intelligence in Ophthalmology · doi:10.35119/maio.v2i4.106 · Cited by 11
Age-Related Variation in the Biomechanical and Structural Properties of the Corneo-Scleral Tunic
Geraghty, B., Whitford, C., Boote, C., Akhtar, R., & Elsheikh, A. (2014) · Engineering materials and processes · doi:10.1007/978-3-319-03970-1_9 · Cited by 11
Patil, R. P., Shetty, R., Patel, Y., Pisharody, A., Narasimhan, R., Pircher, M., Hitzenberger, C. K. F., Nuijts, R. M. M. A., & Roy, A. S. (2022) · Journal of Cataract & Refractive Surgery · doi:10.1097/j.jcrs.0000000000001033 · Cited by 11
Measurement of correlation between transmission and scattering during wound healing in hen corneas
Mar, S., Martínez‐García, C., Blanco-Mezquita, T., Torres, R. M., & Merayo-Llovés, J. (2009) · Journal of Modern Optics · doi:10.1080/09500340902871389 · Cited by 10
Gururani, H., Richhariya, A., Ramji, M., & Chinthapenta, V. R. (2021) · Optik · doi:10.1016/j.ijleo.2021.166529 · Cited by 9
Computational Biomechanics of the Human Cornea
Pandolfi, A. M. (2009) · Springer eBooks · doi:10.1007/978-90-481-3575-2_15 · Cited by 9
Businaro, E., Studer, H., Pajic, B., & Büchler, P. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.01.012 · Cited by 9
Qiao, X., Chen, D., Huo, H., Tang, M., Tang, Z., Dong, Y., Liu, X., & Fan, Y. (2021) · Medicine in Novel Technology and Devices · doi:10.1016/j.medntd.2021.100086 · Cited by 8
Keratoconus: cross-linking the window of the eye
Hayes, S., Morgan, S. R., & Meek, K. M. (2021) · Therapeutic Advances in Rare Disease · doi:10.1177/26330040211003573 · Cited by 8
Self-citationSobczak, M., & Asejczyk-Widlicka, M. (2021) · Biomedical Optics Express · doi:10.1364/boe.440274 · Cited by 8
Lanchares, E., Calvo, B., Buey, M. Á. D., Cristóbal, J. Á., & Doblaré, M. (2010) · Journal of Healthcare Engineering · doi:10.1260/2040-2295.1.3.461 · Cited by 8
Daxer, A. (2014) · International Journal of Keratoconus and Ectatic Corneal Diseases · doi:10.5005/jp-journals-10025-1080 · Cited by 8
Biomechanics of the Cornea and Sclera
Nguyen, T. D. (2016) · Springer eBooks · doi:10.1007/978-1-4899-7630-7_14 · Cited by 8
Gómez, C., Pinero, D. P., Paredes, M., del Barrio, J. L. A., & Cavas, F. (2021) · Applied Sciences · doi:10.3390/app112210819 · Cited by 7
Polarized photoacoustic microscopy based on high-order harmonics for anisotropy detection
Wang, T., Yang, J. S., Wang, W., Wang, L., Wang, X., & Zhou, S. (2022) · Annals of Translational Medicine · doi:10.21037/atm-22-794 · Cited by 6
Investigation of microstructural failure in the human cornea through fracture tests
Chittajallu, S. N. S. H., Gururani, H., Tse, K. M., Rath, S. N., Basu, S., & Chinthapenta, V. R. (2023) · Scientific Reports · doi:10.1038/s41598-023-40286-3 · Cited by 7
Sanmillan, I. L., Thumann, G., Kropp, M., Cvejić, Ž., & Pajic, B. (2023) · Micromachines · doi:10.3390/mi14051009 · Cited by 6
Comparative analysis of the corneal birefringence pattern in healthy children and adults
Sobczak, M., Asejczyk-Widlicka, M., Kalinowski, K., & Pierscionek, B. K. (2021) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12835 · Cited by 6
Effect of Intraocular Pressure and Anisotropy on the Optical Properties of the Cornea
Richhariya, A., Verma, Y., Rao, D. K., Roberts, C. J., Mahmoud, A. M., Sangwan, V., Punjabi, S., & Gupta, P. K. (2014) · Asia-Pacific Journal of Ophthalmology · doi:10.1097/apo.0000000000000015 · Cited by 6
Wide Stromal Mapping Using an Anterior Segment Optical Coherence Tomography
Hashmani, N., Hashmani, M., Asghar, N., Islam, M., & Hashmani, S. (2020) · Clinical ophthalmology · doi:10.2147/opth.s242035 · Cited by 5
MyoRing Treatment of Keratoconus
Daxer, A. (2015) · International Journal of Keratoconus and Ectatic Corneal Diseases · doi:10.5005/jp-journals-10025-1104 · Cited by 5
Bellis, M. L. D., Vasta, M., Gizzi, A., & Pandolfi, A. M. (2024) · International Journal of Non-Linear Mechanics · doi:10.1016/j.ijnonlinmec.2024.104736 · Cited by 4
Biomechanical Comparison of PRK, LASIK, and KLEx Using Personalized Finite Element Simulations
Büchler, P., Nambiar, M. H., Frigelli, M., Roy, A. S., Seiler, T. G., & Ariza-Gracia, M. Á. (2025) · Journal of Refractive Surgery · doi:10.3928/1081597x-20250806-01 · Cited by 4
Xu, M., Garcia, M. A. R., Narang, H., Buckley, M. R., Lerner, A. L., & Yoon, G. (2020) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.61.10.54 · Cited by 4
Xiao, X., Xiao, C., & Yin, Y. (2022) · Frontiers in Materials · doi:10.3389/fmats.2022.870134 · Cited by 4
Typical localised element-specific finite element anterior eye model
Towler, J., Consejo, A., Zhou, D., Romano, V., Levis, H. J., Boote, C., Elsheikh, A., Geraghty, B., & Abass, A. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e13944 · Cited by 4
Biomechanical Modeling of Pterygium Radiation Surgery: A Retrospective Case Study
Pajic, B., Aebersold, D. M., Eggspuehler, A., Theler, F., & Studer, H. (2017) · Sensors · doi:10.3390/s17061200 · Cited by 4
Continuous intracorneal ring implantation for treatment of myopic astigmatism
Rattan, S. A. (2018) · International Medical Case Reports Journal · doi:10.2147/imcrj.s173167 · Cited by 4
Grytz, R., & Meschke, G. (2008) · Springer eBooks · doi:10.1007/978-1-4020-9231-2_11 · Cited by 4
Boote, C., Dooley, E. P., Gardner, S. J., Kamma‐Lorger, C. S., Hayes, S., Nielsen, K., Hjortdal, J., Sørensen, T. L.-M., Terrill, N. J., & Meek, K. M. (2013) · PLoS ONE · doi:10.1371/annotation/1ca782a6-c5c1-4ef8-9c08-ca8ae0cdbaa6 · Cited by 4
Self-citationMiller, C., Bellis, M. L. D., & Pandolfi, A. M. (2025) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2025.118297 · Cited by 3
Biomechanical changes and effect on different corneal wound healing in rabbits: A comparative study
Xue, C., Yang, M., Tian, H., & Wang, Y. (2025) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2025.106506 · Cited by 3
The Influence of the Collagen Architecture on the Mechanical Response of the Human Cornea
Pandolfi, A. M. (2017) · Computational methods in applied sciences · doi:10.1007/978-3-319-60885-3_16 · Cited by 3
Iatrogene Keratektasie nach refraktiver Chirurgie – Ursachen, Prophylaxe, Therapie
Wagner, F. M., & Sekundo, W. (2023) · Klinische Monatsblätter für Augenheilkunde · doi:10.1055/a-2073-8478 · Cited by 3
The effect of pupil size on the measurement of corneal birefringence properties: preliminary study
Sobczak, M., Asejczyk-Widlicka, M., & Wilczyński, M. (2023) · Scientific Reports · doi:10.1038/s41598-023-44706-2 · Cited by 3
Patient-Specific Modeling of the Cornea
Asher, R., Gefen, A., & Varssano, D. (2011) · Studies in mechanobiology, tissue engineering and biomaterials · doi:10.1007/8415_2011_106 · Cited by 3
Modeling human corneal polarization properties and comparison with PS-OCT measurements
Fanjul-Vélez, F., Pircher, M., Baumann, B., Götzinger, E., Arce-Diego, J. L., & Hitzenberger, C. K. F. (2009) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.808995 · Cited by 3
di Bartolo, F., Vignali, E., Gasparotti, E., Malacarne, A., Landini, L., & Celi, S. (2021) · Electronics · doi:10.3390/electronics10050579 · Cited by 3
Vahdati, A. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-823913-1.00017-8 · Cited by 2
Gururani, H., Chittajallu, S. N. S. H., Ramji, M., Basu, S., & Chinthapenta, V. R. (2023) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2023.107747 · Cited by 2
An integrated model of the human cornea as a linear biaxial birefringent medium
Sobczak, M., Jóźwik, A., & Kurzynowski, P. (2024) · Scientific Reports · doi:10.1038/s41598-024-55800-4 · Cited by 2
Controlled elevation of intraocular pressure and its impact on ocular aberrations in healthy eyes
Xu, M., Simmons, B. A., Lerner, A. L., & Yoon, G. (2018) · Experimental Eye Research · doi:10.1016/j.exer.2018.02.028 · Cited by 2
Principles of Accelerated Corneal Collagen Cross-Linking
Mazzotta, C. G., Raiskup, F., Baiocchi, S., Scarcelli, G., Friedman, M. D., & Traversi, C. (2017) · Springer eBooks · doi:10.1007/978-3-319-61137-2_1 · Cited by 2
Richhariya, A., Choudhari, N. S., Mohamed, A., Nankivil, D., Badakere, A., Dave, V. P., Punjabi, S., & Sangwan, V. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-812952-4.00012-x · Cited by 2
Applied Anatomy of the Corneal Stroma
Dua, H. S., & Said, D. G. (2019) · Essentials in ophthalmology/Essentials ophthalmology · doi:10.1007/978-3-030-01304-2_23 · Cited by 2
The mechanics of soft biological composites.
Nguyen, T. D., Grazier, J. M., Boyce, B. L., & Jones, R. E. (2007) · doi:10.2172/922773 · Cited by 2
Transmittance and scattering during wound healing after refractive surgery
Mar, S., Martínez‐García, C., Blanco, J. T., Torres, R. M., Gonzalez, V. R., Najera, S., Rodríguez, G., & Merayo, J. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.589440 · Cited by 2
Mega, Y. J. (2013) · Digital Repository Service (Northeastern University) · doi:10.17760/d20003077 · Cited by 2
Pandolfi, A. M. (2020) · Springer eBooks · doi:10.1007/978-3-662-55771-6_37 · Cited by 2
Gururani, H., Chittajallu, S. N. S. H., Doulatramani, M., Chinthapenta, V. R., Basu, S., & Ramji, M. (2024) · PLoS ONE · doi:10.1371/journal.pone.0308204 · Cited by 1
Transparent and hydrophilic “phoenix garment” for corneal stromal regeneration
Li, Y., Yang, Y., & Wang, Z. (2026) · Acta Physico-Chimica Sinica · doi:10.1016/j.actphy.2026.100265 · Cited by 1
A simple mathematical model for collagen fibril organization in normal and keratoconic corneas
Pinsky, P. M., Ma, Y., Hwang, Y., Hayes, S., & Meek, K. M. (2018) · Modeling and Artificial Intelligence in Ophthalmology · doi:10.35119/maio.v2i1.55 · Cited by 1
Self-citationPrediction of SMILE surgical cutting formula based on back propagation neural network
Yuan, D., Yang, C.-H., Zhang, H., Wang, Y., Zhang, W., Gu, L., & Liu, Q. (2023) · International Journal of Ophthalmology · doi:10.18240/ijo.2023.09.08 · Cited by 1
Corneal densitometry and associated factors in an elderly population
Hashemi, A., Nabovati, P., Hashemi, H., Mortazavi, A., & Khabazkhoob, M. (2023) · Clinical and Experimental Optometry · doi:10.1080/08164622.2023.2242864 · Cited by 1
Corneal stromal mapping characteristics in normal corneas using anterior segment SD-OCT
Abusamak, M., Issa, S. M., Alomari, A. F., ALSalamat, H., Ali, N. S. H., Izmegna, A., Shawashreh, M., Abu‐Samak, M., & Abusamak, T. M. (2024) · Frontiers in Medicine · doi:10.3389/fmed.2024.1485718 · Cited by 1
The Biomechanics of Keratorefractive Surgery
Hull, C. C., & Know-Cartwright, N. E. (2008) · City Research Online (City University London) · Cited by 1
Accommodative tissues influence the shape of the cornea and potentially drive corneal morphogenesis
Tram, N. K., Jiang, P., Jacobs, K. M., Ruzga, M. N., Allen, M. G., Prieto, R. P., Carus, S. A., Reilly, M. A., & Swindle‐Reilly, K. E. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.109582 · Cited by 1
Birefringent properties of the human cornea in vivo : towards a new model of corneal structure
Misson, G. P. (2026) · University of Warwick · doi:10.82444/warw.33626113 · Cited by 1
Morgan, S. R. (2014) · ORCA Online Research @Cardiff (Cardiff University) · Cited by 1
Iris biomechanics in health and disease.
Amini, R. (2010) · University of Minnesota Digital Conservancy (University of Minnesota) · Cited by 1
Pandolfi, A. M. (2018) · Springer eBooks · doi:10.1007/978-3-662-53605-6_37-1 · Cited by 1
Finite Element Modelling for the Reproduction of Dynamic Oce Measurements in the CorneaPreprint
Merlini, G., Imperiale, S., & Allain, J. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5172945 · Cited by 1
Metadata
- Authors
- Aghamohammadzadeh, H., Newton, R. H., & Meek, K. M.
- Affiliations
- Cardiff University (GB)
- Venue
- Structure
- Publisher
- Elsevier BV
- Published
- 2004-02
- Volume
- 12
- Issue
- 2
- Pages
- 249-256
- ISSN
- 0969-2126 (ISSN-L)
- OpenAlex
- W2081339779
- Cited by
- 233
- References
- 19
- Citations by year
- 2026: 5 · 2025: 10 · 2024: 12 · 2023: 12 · 2022: 9 · 2021: 11 · 2020: 9 · 2019: 11 · 2018: 11 · 2017: 18 · 2016: 9 · 2015: 11 · 2014: 16 · 2013: 13 · 2012: 5
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Structure (publishedVersion)
- PubMed (publishedVersion)
- ePubs (Science and Technology Facilities Council, Research Councils UK) (submittedVersion)
- Topics
- Health Sciences › Medicine › Ophthalmology › Corneal surgery and disorders
- Physical Sciences › Materials Science › Biomaterials › Collagen: Extraction and Characterization
- Physical Sciences › Physics and Astronomy › Radiation › Advanced X-ray Imaging Techniques
- Keywords
- collagen fibril orientation, cornea, limbus, sclera, collagen anisotropy, corneal curvature, synchrotron X-ray scattering, tissue mechanical properties
- MeSH terms
- Animals, Corneal Stroma, Humans, Sclera, X-Ray Diffraction, Limbus Corneae, Fibrillar Collagens
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review