The DOI matches its Crossref record; 18 of the 19 references it cites were found in a registry or an index.
X-Ray Scattering Used to Map the Preferred Collagen Orientation in the Human Cornea and Limbus
Open accessAbstract
Many properties of connective tissues are governed by the organization of the constituent collagen. For example, the organization of collagen in the cornea and the limbus, where the cornea and sclera meet, is an important determinant of corneal curvature and hence of the eye's focusing power. We have used synchrotron X-ray scattering to map the orientation of the collagen fibrils throughout the human cornea, limbus, and adjacent sclera. We demonstrate a preferred orientation of collagen in the vertical and horizontal directions that is maintained to within about 1 mm from the limbus, where a circular or tangential disposition of fibrils occurs. The data are also used to map the relative distribution of both the total and the preferentially aligned collagen in different parts of the tissue, revealing considerable anisotropy. The detailed structural information provided is an important step toward understanding the shape and the mechanical properties of the tissue.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Maurice and colleagues initially employed X‐rays to investigate structural features pertaining to the arrangement of collagen fibers in corneal tissues, enabling the quantification of the orientation and content of collagen fibers across the cornea and limbus, with changes in fiber arrangement being readily detected via X‐ray scattering patterns.[ 94 , 105 , 111 ]”
From Bioactive scaffolds for tissue engineering: A review of decellularized extracellular matrix applications and innovations (2025) · cites this paper as [111]
In the citing paper
“although water distribution from central cornea to limbus is not known for human corneas, it seems likely that alterations in tissue thickness are due to an increase in the amount of collagen in the peripheral stroma (Aghamohammadzadeh et al., 2004, Boote et al., 2011, Henriksson et al., 2012).”
From Corneal structure and transparency (2015) · cites this paper as Aghamohammadzadeh et al., 2004
In the citing paper
“Collagen lamellae in the deeper stroma (Fig. 1a) have preferred directions, which appear to be close to the inferior-superior and nasal-temporal directions (Meek et al., 1987, Aghamohammadzadeh et al., 2004, Abahussin et al., 2009, Kamma-Lorger et al., 2010).”
From Corneal structure and transparency (2015) · cites this paper as Aghamohammadzadeh et al., 2004
In the citing paper
“X-ray scattering has also suggested the presence of a network of collagen lamellae that enter the cornea close to the inferior, superior, nasal and temporal positions, and which probably originate in the adjacent sclera (Aghamohammadzadeh et al., 2004).”
From Corneal structure and transparency (2015) · cites this paper as Aghamohammadzadeh et al., 2004
In the citing paper
“X-ray scattering has shown that the lamellae have preferred orientations in the human cornea: inferior-superior and nasal-temporal in the central cornea and circumferential at the limbus.”
From Structural control of corneal transparency, refractive power and dynamics (2025) · cites this paper as [13]
In the citing paper
“Throughout the optical zone, there is a preference for lamellae to run in the inferior-superior and temporal-nasal directions.”
From Structural control of corneal transparency, refractive power and dynamics (2025) · cites this paper as [13]
Citations
Cites
Principles and Practice of Ophthalmology
(1981) · American Journal of Ophthalmology · doi:10.1016/0002-9394(81)90081-7 · Cited by 1,073
Maurice, D. M. (1962) · Elsevier eBooks · doi:10.1016/b978-1-4832-3090-0.50013-7 · Cited by 436
Principles and Practice of Ophthalmology,
Tessler, H. H. (2000) · Survey of Ophthalmology · doi:10.1016/s0039-6257(00)00166-1 · Cited by 409
(1997) · PubMed · Cited by 326
The organization of collagen in the corneal stroma
Meek, K. M., & Boote, C. (2003) · Experimental Eye Research · doi:10.1016/j.exer.2003.07.003 · Cited by 297
Self-citationRegional elastic performance of the human cornea
Hjortdal, J. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00152-2 · Cited by 233
Meek, K. M., Blamires, T., Elliott, G. F., Gyi, T. J., & Nave, C. (1987) · Current Eye Research · doi:10.3109/02713688709034853 · Cited by 161
Self-citationInterlacing and cross-angle distribution of collagen lamellae in the human cornea
Radner, W., Zehetmayer, M., Aufreiter, R., & Mallinger, R. (1998) · Cornea · doi:10.1097/00003226-199809000-00012 · Cited by 153
The use of X-ray scattering techniques to determine corneal ultrastructure
Meek, K. M., & Quantock, A. J. (2001) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(00)00016-1 · Cited by 139
Self-citation(1998) · PubMed · Cited by 111
Self-citation
Flagged first, then by citations
1 of the 19 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Items 201–233 of 233
Application of optical methods for the evaluation of human tissues generated by tissue engineering
Ionescu, A. M. (2013) · Institutional Repository of the University of Granada (University of Granada)
Whitford, C., Studer, H., Boote, C., Meek, K. M., & Elsheikh, A. (2014) · Elsevier eBooks · doi:10.1016/b978-84-9022-649-0.50033-8
Self-citationCorneal map gives fresh view of the eye
Hopkin, M. (2004) · Nature · doi:10.1038/news040209-5
Sayas, M. A. Á. D. B., & Peris‐Martínez, C. (2014) · Elsevier eBooks · doi:10.1016/b978-84-9022-649-0.50031-4
Clinical and laboratory investigation of the biomechanical properties of the cornea
Alhamad, T. A. (2012) · ORCA Online Research @Cardiff (Cardiff University)
Dynamic OCT measurements of corneal biomechanical properties after UV cross-linking in the rabbit
Twa, M. D., Li, J., Manapuram, R. K., Menodiado, F. M., Singh, M., Aglyamov, S. R., Emelianov, S., & Larin, K. V. (2013) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2007109
Physics and biology: Applications of synchrotron radiation in biology
Johnson, L. N. (2008) · Contemporary Physics · doi:10.1142/9789812818942_0001
Ethier, C. R., Dahlmann-Noor, A. H., Vijay, S., Khaw, P. T., & Girard, M. J. A. (2010) · ASME Summer Bioengineering Conference (SBC) · doi:10.1115/sbc2010-19363
White, T. L. (2016) · ORCA Online Research @Cardiff (Cardiff University)
Fanjul-Vélez, F., Pircher, M., Baumann, B., Götzinger, E., Ortega-Quijano, N., García, I. S., Hitzenberger, C. K. F., & Diego, J. L. A. (2010) · UCrea (University of Cantabria)
Quantitative response of OH/CH Raman bands in diseased soft tissue: First results
Djurdjic, E., Pajic, B., Srdjan, R., Milica, P.-H., & Cvejić, Ž. (2017) · IEEE MTT-S International Microwave Workshop Series on Advanced Materials and Processes for RF and THz Applications (IMWS-AMP) · doi:10.1109/imws-amp.2017.8247441
Dey, A., David, R. L., Asokan, R., & George, R. J. (2018) · Asian Journal of Ophthalmology · doi:10.35119/asjoo.v16i1.344
Ocular Rigidity and Cornea Disease
Tzamalis, A. K., Arbabi, E. M., & TAYLOR, D. A. H. B. (2021) · Springer eBooks · doi:10.1007/978-3-030-64422-2_17
Investigation of transmission and emergence of USUTU virus in Africa
Nikolay, B. (2011)
(2004) · Science of Aging Knowledge Environment · doi:10.1126/sageke.2004.6.nw5
Tractography Using Polarization-Sensitive Optical Coherence Tomography
Yao, G. (2022) · Springer eBooks · doi:10.1007/978-3-031-04741-1_10
Gururani, H., Chittajallu, S. N. S. H., Doulatramani, M., Ramji, M., Basu, S., & Chinthapenta, V. R. (2023) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2023.104076
GIRAUDET, C., & Allain, J. (2024) · doi:10.1002/9781394306596.ch3
Clarkson, D. (2024) · Optician · doi:10.12968/opti.2024.269.6936.22
Reinstein, D. Z., Archer, T. J., & Wagner, F. M. (2024) · Springer eBooks · doi:10.1007/978-3-031-60424-9_14
Keratectasia Prevention, Recognition, and Treatment
Wagner, F. M., & Sekundo, W. (2024) · Springer eBooks · doi:10.1007/978-3-031-60424-9_19
Limbus Compensation for corneal deformation Under Intraocular Pressure FluctuationsPreprint
Dai, Y., Peng, Q., Pan, J., Wang, L., Liu, X., & Wang, R. C. (2025) · Research Square · doi:10.21203/rs.3.rs-7057735/v1
Finite element modeling of transient shear wave elastography for the cornea
Merlini, G., Imperiale, S., & Allain, J. (2025) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2025.106363
Bell, J. S., Morgan, S. R., Shebanova, O. N., Evans, S. L., Boote, C., Terrill, N. J., Meek, K. M., & Hayes, S. (2025) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2025.1603679
Self-citationNi, L., Warchock, A., Krawczyk, E., Kim, W., Moroi, S. E., Xu, G., & Argento, A. (2025) · Translational Vision Science & Technology · doi:10.1167/tvst.14.10.9
Hamid, M. A., Esmail, M. E. K., & Zein, H. A. (2025) · BMC Ophthalmology · doi:10.1186/s12886-025-04476-z
Microstructure-based constitutive modeling of corneal nonlinear anisotropic rheology and modulus
Li, Y., Yang, Z., Yan, Z., Liu, Z., & Wang, K. (2025) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2025.106381
Comparative analysis of corneal biomechanical parameters in pterygium using scheimpflug technology
Li, F., He, X., Li, X., Zhou, Y., Sun, J., Ding, R., Yu, Y., Shi, W., Zhao, C., & Wang, T. (2026) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-026-07132-4
Refractive Index Engineering for Human Corneal Tissue by Femtosecond Laser Two‐Photon Cross‐Linking
Qi, P., Zhou, Z., An, J., Liu, H., Zhang, Y., Liu, H., Chang, L., Wu, Y., Wang, Y., Kosareva, O. G., et al. (2026) · Journal of Biophotonics · doi:10.1002/jbio.70336
Calhoun (2015) · VCU Scholars Compass (Virginia Commonwealth University) · doi:10.25772/pxdg-hp97
Opto-Mechanical Model of Arcuates for Astigmatism Correction. Low and High Order Aberrations
Navarro, R., Palos, F., Lanchares, E., Calvo, B., & Cristóbal, J. Á. (2011) · DIGITAL.CSIC (Spanish National Research Council (CSIC))
Metadata
- Authors
- Aghamohammadzadeh, H., Newton, R. H., & Meek, K. M.
- Affiliations
- Cardiff University (GB)
- Venue
- Structure
- Publisher
- Elsevier BV
- Published
- 2004-02
- Volume
- 12
- Issue
- 2
- Pages
- 249-256
- ISSN
- 0969-2126 (ISSN-L)
- OpenAlex
- W2081339779
- Cited by
- 233
- References
- 19
- Citations by year
- 2026: 5 · 2025: 10 · 2024: 12 · 2023: 12 · 2022: 9 · 2021: 11 · 2020: 9 · 2019: 11 · 2018: 11 · 2017: 18 · 2016: 9 · 2015: 11 · 2014: 16 · 2013: 13 · 2012: 5
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Structure (publishedVersion)
- PubMed (publishedVersion)
- ePubs (Science and Technology Facilities Council, Research Councils UK) (submittedVersion)
- Topics
- Health Sciences › Medicine › Ophthalmology › Corneal surgery and disorders
- Physical Sciences › Materials Science › Biomaterials › Collagen: Extraction and Characterization
- Physical Sciences › Physics and Astronomy › Radiation › Advanced X-ray Imaging Techniques
- Keywords
- collagen fibril orientation, cornea, limbus, sclera, collagen anisotropy, corneal curvature, synchrotron X-ray scattering, tissue mechanical properties
- MeSH terms
- Animals, Corneal Stroma, Humans, Sclera, X-Ray Diffraction, Limbus Corneae, Fibrillar Collagens
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review