Diagnostic Tools for Glaucoma Detection and Management
Open accessThe DOI matches its Crossref record; 83 of the 83 references it cites were found in a registry or an index.
Abstract
Early diagnosis of glaucoma is critical to prevent permanent structural damage and irreversible vision loss. Detection of glaucoma typically relies on examination of structural damage to the optic nerve combined with measurements of visual function. To aid the clinician in evaluation of visual function and structure, computer-based devices such as confocal scanning laser ophthalmoscopy, scanning laser polarimetry, and optical coherence tomography provide quantitative assessments of structural damage, and visual function testing includes standard automated perimetry as well as selective techniques, including short-wavelength automated perimetry and frequency-doubling technology perimetry are available. This article will review current literature on diagnostic modalities available for glaucoma with emphasis on the best evidence available in the literature to support their use in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Self-citationKass, M. A. (2002) · Archives of Ophthalmology · doi:10.1001/archopht.120.6.701 · Cited by 3,705
Heijl, A. (2002) · Archives of Ophthalmology · doi:10.1001/archopht.120.10.1268 · Cited by 3,320
Gordon, M. O. (2002) · Archives of Ophthalmology · doi:10.1001/archopht.120.6.714 · Cited by 2,626 · cited 3×
“Current evidence suggests that in many eyes significant optic nerve damage may precede visual field loss; in the Ocular Hypertension Treatment Study (OHTS), for example, disk change was detected earlier than visual field abnormalities in over half of patients progressing to an initial diagnosis of glaucoma.(44) As a r…”
BackgroundMethodResultRetinal Ganglion Cell Atrophy Correlated With Automated Perimetry in Human Eyes With Glaucoma
Quigley, H. A., Dunkelberger, G. R., & Green, W. R. (1989) · American Journal of Ophthalmology · doi:10.1016/0002-9394(89)90488-1 · Cited by 1,123
Kerrigan, L. A., Quigley, H. A., Pease, M. E., Kerrigan, D., & Mitchell, R. S. (2000) · PubMed · Cited by 996
Ultrahigh-resolution ophthalmic optical coherence tomography
Drexler, W., Morgner, U., Ghanta, R. K., Kärtner, F. X., Schuman, J. S., & Fujimoto, J. G. (2001) · Nature Medicine · doi:10.1038/86589 · Cited by 962
Self-citationSchuman, J. S. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100050054031 · Cited by 879
Self-citationA framework for comparing structural and functional measures of glaucomatous damage
Hood, D. C., & Kardon, R. H. (2007) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.08.001 · Cited by 703 · cited 1×
“When SAP damage is detected first, it may be that the patient started out with more structure to begin with, and are still within the normal limits of the structural test utilized.(58)”
BackgroundReproducibility of Nerve Fiber Layer Thickness Measurements Using Optical Coherence Tomography
Schuman, J. S., Pedut-Kloizman, T., Hertzmark, E., Hee, M. R., Wilkins, J. R., Coker, J. G., Puliafito, C. A., Fujimoto, J. G., & Swanson, E. A. (1996) · Ophthalmology · doi:10.1016/s0161-6420(96)30410-7 · Cited by 665
Self-citationMedeiros, F. A., Zangwill, L. M., Bowd, C., Vessani, R. M., Susanna, R., & Weinreb, R. N. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2004.08.069 · Cited by 649 · cited 1×
“However, studies comparing the ability of Stratus OCT to distinguish between normal and glaucomatous eyes using macular, RNFL, and ONH assessments found that the ONH and RNFL thickness parameters provided the best discrimination between normal and glaucomatous eyes, whereas measurements of total retinal thickness in t…”
ResultSelf-citationDacey, D. M., & Lee, B. B. (1994) · Nature · doi:10.1038/367731a0 · Cited by 582
Quigley, H. A., Katz, J., Derick, R. J., Gilbert, D., & Sommer, A. (1992) · Ophthalmology · doi:10.1016/s0161-6420(92)32018-4 · Cited by 575
Leske, M. C., Heijl, A., Hyman, L., & Bengtsson, B. (1999) · Ophthalmology · doi:10.1016/s0161-6420(99)90497-9 · Cited by 566 · cited 1×
“Over the past several years, a number of clinical trials have incorporated the development or progression of vision loss measured with standard visual fields as a primary endpoint.(1,45,77,103,105) The OHTS evaluated the effects of lowering intraocular pressure in eyes with ocular hypertension that had no loss of visi…”
BackgroundPaunescu, L. A., Schuman, J. S., Price, L. L., Stark, P. C., Beaton, S., Ishikawa, H., Wollstein, G., & Fujimoto, J. G. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-0514 · Cited by 536
Self-citationMacular Segmentation with Optical Coherence Tomography
Ishikawa, H., Stein, D. M., Wollstein, G., Beaton, S., Fujimoto, J. G., & Schuman, J. S. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0335 · Cited by 498 · cited 1×
“In order for macular thickness to have clinical value in glaucoma discrimination segmentation of the intraretinal layers is necessary.(62) Only one cohort study by Wollstein et al has been published to date evaluating the ability of a prototype OCT device to detect change in RNFL thickness longitudinally.”
BackgroundSelf-citationMedeiros, F. A. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.6.827 · Cited by 455 · cited 1×
“Medeiros et al compared the most widely utilized versions of each of the three imaging technologies (HRT II ONH scan, GDx VCC RNFL scan, and Stratus OCT fast RNFL scan), and reported nearly equivalent AUCs for the best parameters from each device.(98)”
MethodThe Ocular Hypertension Treatment Study: Design and Baseline Description of the Participants
Gordon, M. O. (1999) · Archives of Ophthalmology · doi:10.1001/archopht.117.5.573 · Cited by 441 · cited 2×
“Over the past several years, a number of clinical trials have incorporated the development or progression of vision loss measured with standard visual fields as a primary endpoint.(1,45,77,103,105) The OHTS evaluated the effects of lowering intraocular pressure in eyes with ocular hypertension that had no loss of visi…”
BackgroundMethodMusch, D. (1999) · Ophthalmology · doi:10.1016/s0161-6420(99)90147-1 · Cited by 402 · cited 1×
“Over the past several years, a number of clinical trials have incorporated the development or progression of vision loss measured with standard visual fields as a primary endpoint.(1,45,77,103,105) The OHTS evaluated the effects of lowering intraocular pressure in eyes with ocular hypertension that had no loss of visi…”
BackgroundArtes, P. H., Iwase, A., Ohno, Y., Kitazawa, Y., & Chauhan, B. C. (2002) · PubMed · Cited by 396
Yücel, Y. (2003) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(03)00026-0 · Cited by 384
Blue-on-Yellow Perimetry Can Predict the Development of Glaucomatous Visual Field Loss
Johnson, C. A. (1993) · Archives of Ophthalmology · doi:10.1001/archopht.1993.01090050079034 · Cited by 372
Detecting early glaucoma by assessment of retinal nerve fiber layer thickness and visual function.
Bowd, C., Zangwill, L. M., Berry, C. C., Blumenthal, E. Z., Vasile, C., Sánchez-Galeana, C. A., Bosworth, C. F., Sample, P. A., & Weinreb, R. N. (2001) · PubMed · Cited by 369
Self-citation(2007) · Ophthalmology · doi:10.1016/j.ophtha.2006.05.075 · Cited by 359 · cited 1×
“The OHTS and the EGPS also found (level II) that visual field loss was the first endpoint reached by converting eyes in 35% and 60% of the eyes, respectively.(71,101) The EMGT, a level I study comparing treatment to observation in cases of early glaucoma,(51) also found in a level II post-hoc analysis that change in v…”
Method(2007) · Ophthalmology · doi:10.1016/j.ophtha.2006.08.031 · Cited by 351 · cited 3×
“This finding was validated in an independent dataset of ocular hypertensives from the Diagnostic Innovations in Glaucoma Study (DIGS)92 and again with another independent cohort from the EGPS.46 The OHTS and the EGPS also found (level II) that visual field loss was the first endpoint reached by converting eyes in 35%…”
ResultInfluentialExpert Agreement in Evaluating the Optic Disc for Glaucoma
Varma, R., Steinmann, W. C., & Scott, I. U. (1992) · Ophthalmology · doi:10.1016/s0161-6420(92)31990-6 · Cited by 330
Evidence that Blue‐on Cells are Part of the Third Geniculocortical Pathway in Primates
Martin, P. R., White, A. J. R., Goodchild, A. K., Wilder, H. D., & Sefton, A. E. (1997) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.1997.tb01509.x · Cited by 328 · cited 1×
“The stimulus information is then processed through the blue-yellow (aka small bistratified) ganglion cells(29,30) that project their axons to the koniocellular (interlaminar) layers of the lateral geniculate nucleus of the thalamus.(88) SWAP is commercially available in both Humphrey and Octopus perimeters, and the te…”
MethodResults of the European Glaucoma Prevention Study
(2005) · Ophthalmology · doi:10.1016/j.ophtha.2004.11.030 · Cited by 323 · cited 3×
“Only 10% of eyes in the OHTS and none in the EGPS showed structural and functional change at the same time.(71,102) Using very different techniques for detection of optic disk changes than the OHTS and EGPS, the EMGT (level I evidence) utilized flicker chronoscopy and side-by-side comparisons of non-stereoscopic fundu…”
BackgroundMethodResultYücel, Y. H. (2000) · Archives of Ophthalmology · doi:10.1001/archopht.118.3.378 · Cited by 306
Intraobserver and Interobserver Agreement in Measurement of Optic Disc Characteristics
Tielsch, J. M., Katz, J., Quigley, H. A., Miller, N. R., & Sommer, A. (1988) · Ophthalmology · doi:10.1016/s0161-6420(88)33177-5 · Cited by 274 · cited 1×
“However, due to the inherent subjectivity of a qualitative assessment, there is considerable variability in classifying the ONH as normal or glaucomatous both within and between graders.(132,135) Even among glaucoma specialists, there can be high intra- and interobserver variability in clinically assessing the optic d…”
BackgroundColour coding in the primate retina: diverse cell types and cone-specific circuitry
Dacey, D. M., & Packer, O. S. (2003) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(03)00103-x · Cited by 264
Frequency doubling technology perimetry for detection of glaucomatous visual field loss
Cello, K. E., Nelson-Quigg, J. M., & Johnson, C. A. (2000) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(99)00414-6 · Cited by 256
Structure versus Function in Glaucoma: An Application of a Linear Model
Hood, D. C., Anderson, S., Wall, M., & Kardon, R. H. (2007) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-1401 · Cited by 241 · cited 1×
“Moreover, reproducibility of the measurements varies by individual, type of test, and stage of disease so that the test with the lowest variability (structural or functional) may show the first sign of glaucomatous change.(57) There also may be clinical, demographic, or ocular characteristics that can help predict whe…”
BackgroundJohnson, C. A. (1993) · Archives of Ophthalmology · doi:10.1001/archopht.1993.01090050085035 · Cited by 232 · cited 4×
“Despite the disadvantages, early studies found SWAP--full threshold (FT) to have a higher sensitivity for early glaucomatous damage than SAP,(64,121) with the ability to detect visual field loss 3--5 years earlier than SAP.(65) For example, one study compared glaucomatous structural damage to function measured with SA…”
InfluentialGreenfield, D. S., Knighton, R. W., & Huang, X.-R. (2000) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(00)00353-6 · Cited by 231
Sample, P. A., Bosworth, C. F., Blumenthal, E. Z., Girkin, C. A., & Weinreb, R. N. (2000) · PubMed · Cited by 223
Self-citationYücel, Y. H., Zhang, Q., Weinreb, R. N., Kaufman, P. L., & Gupta, N. (2001) · PubMed · Cited by 214
Burgansky-Eliash, Z., Wollstein, G., Chu, T., Ramsey, J. D., Glymour, C., Noecker, R. J., Ishikawa, H., & Schuman, J. S. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-0366 · Cited by 203 · cited 1×
“However, studies comparing the ability of Stratus OCT to distinguish between normal and glaucomatous eyes using macular, RNFL, and ONH assessments found that the ONH and RNFL thickness parameters provided the best discrimination between normal and glaucomatous eyes, whereas measurements of total retinal thickness in t…”
ResultSelf-citationWollstein, G., Schuman, J. S., Price, L. L., Aydin, A., Beaton, S. A., Stark, P. C., Fujimoto, J. G., & Ishikawa, H. (2004) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2004.03.019 · Cited by 198 · cited 4×
“Although OCT was originally designed to evaluate retinal thickness, software development has also permitted ONH analysis; the highest performing ONH parameters for Stratus OCT such as C/D ratio and integrated rim volume have AUCs equivalent to the best RNFL parameters.(79,80,84,126,144) OCT is also useful for macular…”
MethodResultInfluentialSelf-citationKrieglstein, G. K. (1988) · American Journal of Ophthalmology · doi:10.1016/0002-9394(88)90150-x · Cited by 196
Performance of nonlinear visual units in ocular hypertension and glaucoma
Maddess, T. L., & Henry, G. H. (1992) · Clinical vision sciences · Cited by 194
Medeiros, F. A. (2005) · Archives of Ophthalmology · doi:10.1001/archopht.123.10.1351 · Cited by 187
Medeiros, F. A., Sample, P. A., & Weinreb, R. N. (2004) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2003.12.009 · Cited by 186 · cited 1×
“Early evidence has shown the test may be more sensitive to early glaucomatous defect than is standard perimetry.(17,23,25,61,66,91,116,117,145) FDT has been used for screening for glaucoma more often than other visual field test types and results support its usefulness.”
BackgroundSelf-citationGlaucoma Detection Using Scanning Laser Polarimetry With Variable Corneal Polarization Compensation
Weinreb, R. N., Bowd, C., & Zangwill, L. M. (2003) · Archives of Ophthalmology · doi:10.1001/archopht.121.2.218 · Cited by 182
Self-citationShort-wavelength Color Visual Fields in Glaucoma Suspects at Risk
Sample, P. A., Taylor, J. D. N., Martinez, G. A., Lusky, M., & Weinreb, R. N. (1993) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)73928-5 · Cited by 174
Self-citationIdentifying early glaucoma with optical coherence tomography
Nouri-Mahdavi, K., Hoffman, D., Tannenbaum, D. P., Law, S. K., & Caprioli, J. (2004) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2003.09.004 · Cited by 172 · cited 1×
“971, inferior).(11,19,70,79,106) Specifically, the inferior/inferotemporal (6 and 7 clock hours) and superior/ superotemporal (11 and 12 clock hours) had the highest AUCs.”
BackgroundSchlottmann, P. G., De Cilla, S., Greenfield, D. S., Caprioli, J., & Garway-Heath, D. F. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-0692 · Cited by 171 · cited 1×
“Several studies have shown that the addition of VCC to GDx substantially enhances its discriminating power for glaucoma detection(18,136) and correlation with visual field loss.(15,123) GDx-VCC has been shown to have good diagnostics accuracy, with reported area-under-the-curve values (AUCs) for glaucoma detection ran…”
BackgroundDeLeo´n-Ortega, J. E., Arthur, S. N., McGwin, G., Xie, A., Monheit, B. E., & Girkin, C. A. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-1239 · Cited by 170 · cited 1×
“Other level II studies have also overcome some of this variability by using a variety of methods to standardize optic disk evaluation.(32,37,41,52,94) Recently, there have been tremendous advances in the development of computer-based technologies with the ability to provide reproducible, quantitative assessments of th…”
MethodZangwill, L. M. (2005) · Archives of Ophthalmology · doi:10.1001/archopht.123.9.1188 · Cited by 161 · cited 3×
“ment of a repeatable optic disk or visual field endpoint.(151) Specifically, baseline MRA results outside of normal limits in any sector had a 2.”
BackgroundInfluentialSelf-citationLalezary, M., Medeiros, F. A., Weinreb, R. N., Bowd, C., Sample, P. A., Tavares, I. M., Tafreshi, A., & Zangwill, L. M. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2006.05.004 · Cited by 160
Self-citationEuropean Glaucoma Prevention Study: Author reply
Miglior, S., Pfeiffer, N., Zeyen, T. G., Cunha-Vaz, J. G., Torri, V., & Adamsons, I. A. (2005) · Ophthalmology · doi:10.1016/j.ophtha.2005.06.020 · Cited by 153
The Ocular Hypertension Treatment Study
Higginbotham, E. J. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.6.813 · Cited by 153
Medeiros, F. A., Zangwill, L. M., Bowd, C., Sample, P. A., & Weinreb, R. N. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.01.003 · Cited by 135 · cited 3×
“In a cross-sectional analysis by Medeiros et al, the GDx-VCC was able to detect structural abnormalities in preperimetric eyes with progressive optic disk changes as compared to controls.(94) A study of glaucoma suspects by Mohammadi et al demonstrated that the original GDx Nerve Fiber Analyzer RNFL thickness measurem…”
BackgroundResultSelf-citationBurnstein, Y., Ellish, N. J., Magbalon, M., & Higginbotham, E. J. (2000) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(99)00364-5 · Cited by 127 · cited 1×
“Early evidence has shown the test may be more sensitive to early glaucomatous defect than is standard perimetry.(17,23,25,61,66,91,116,117,145) FDT has been used for screening for glaucoma more often than other visual field test types and results support its usefulness.”
BackgroundKeltner, J. L., Johnson, C. A., ANDERSON, D., Levine, R. A., Fan, J., Cello, K. E., Quigley, H. A., Budenz, D. L., Parrish, R. K., II, & Kass, M. A. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2006.05.061 · Cited by 122
Sample, P. A., Medeiros, F. A., Racette, L., Pascual, J. P., Boden, C., Zangwill, L. M., Bowd, C., & Weinreb, R. N. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-1546 · Cited by 114 · cited 4×
“The finding, which suggests that glaucoma damage is non-selective for RGC type has been supported by recent work in the lateral geniculate nucleus with other psychophysics(89) and with more recent inter-function comparison studies.(120) These findings suggest the premise that both structure and function are important…”
MethodResultInfluentialSelf-citationThe European glaucoma prevention study design and baseline description of the participants
Miglior, S., Zeyen, T. G., Pfeiffer, N., Cunha-Vaz, J. G., Torri, V., & Adamsons, I. A. (2002) · Ophthalmology · doi:10.1016/s0161-6420(02)01167-3 · Cited by 110 · cited 1×
“Over the past several years, a number of clinical trials have incorporated the development or progression of vision loss measured with standard visual fields as a primary endpoint.(1,45,77,103,105) The OHTS evaluated the effects of lowering intraocular pressure in eyes with ocular hypertension that had no loss of visi…”
BackgroundKymes, S. M., Kass, M. A., Anderson, D. R., Miller, J. P., & Gordon, M. O. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2006.01.019 · Cited by 107 · cited 1×
“This is important because economic analyses from OHTS suggested that ocular hypotensive treatment is costeffective in the subgroup of ocular hypertensive individuals with an IOP $ 24 mm Hg and an annual risk of POAG $ 2%.(75) Unfortunately, it is difficult to assess the annual risk of developing POAG in an individual…”
BackgroundAutomated Analysis of Heidelberg Retina Tomograph Optic Disc Images by Glaucoma Probability Score
Coops, A., Henson, D. B., Kwartz, A. J., & Artes, P. H. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-0579 · Cited by 101 · cited 1×
“Furthermore, the diagnostic accuracy of both MRA and GPS improves with increasing disk size and severity of disease; however, very small disks and very large disks tend to reduce the sensitivity and specificity of the device, respectively.(28,150) An additional improvement to the HRT version 3.”
BackgroundFrequency Doubling Technology Perimetry Using a 24-2 Stimulus Presentation Pattern
Johnson, C. A., Cioffi, G. A., & Buskirk, E. M. V. (1999) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1999.tb05474.x · Cited by 94
Quantitative assessment of the optic nerve head with the laser tomographic scanner
Weinreb, R. N., Dreher, A. W., & Bille, J. F. (1989) · International Ophthalmology · doi:10.1007/bf02028633 · Cited by 89 · cited 1×
“height measurements of the retinal and ONH surface topography.(137) A number of stereometric parameters are generated by CSLO, including rim area, rim volume, cup shape measure, linear cup/ disk (C/D) ratio, retinal height variation along the contour line, and RNFL thickness.”
MethodBowd, C., Medeiros, F. A., Zhang, Z., Zangwill, L. M., Hao, J., Lee, T.-W., B, T. J. S. A., Weinreb, R. N., & Goldbaum, M. H. (2005) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-1122 · Cited by 88 · cited 1×
“978.(12,36,97) A study comparing GDx-VCC with RNFL photography found that although both techniques correlate with damage in corresponding hemiretinas, the best GDx-VCC parameter had a higher degree of discriminant ability than the best RNFL photographic parameter.”
Self-citationWilliams, Z. Y., Schuman, J. S., Gamell, L. S., Nemi, A., Hertzmark, E., Fujimoto, J. G., Mattox, C. G., Simpson, J. A., & Wollstein, G. (2002) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(02)01683-5 · Cited by 87 · cited 1×
“Additionally, OCT is able to identify RNFL defects in areas corresponding to visual field deficits.(139) Some studies have shown that RNFLs of the superior and inferior quadrants have been shown”
BackgroundSelf-citationZangwill, L. M., Jain, S., Racette, L., Ernstrom, K. B., Bowd, C., Medeiros, F. A., Sample, P. A., & Weinreb, R. N. (2007) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-1314 · Cited by 86 · cited 2×
“The GPS has been shown in level II studies to have comparable overall diagnostic accuracy to the MRA,(20,28) with the GPS tending toward higher sensitivity and lower specificity.(49,150) Furthermore, the diagnostic accuracy of both MRA and GPS improves with increasing disk size and severity of disease; however, very s…”
BackgroundMethodSelf-citationBourne, R., Medeiros, F. A., Bowd, C., Jahanbakhsh, K., Zangwill, L. M., & Weinreb, R. N. (2005) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-1000 · Cited by 86
Self-citationFive rules to evaluate the optic disc and retinal nerve fiber layer for glaucoma
Fingeret, M., Medeiros, F. A., Susanna, R., & Weinreb, R. N. (2005) · Optometry · doi:10.1016/j.optm.2005.08.029 · Cited by 82 · cited 2×
“Other level II studies have also overcome some of this variability by using a variety of methods to standardize optic disk evaluation.(32,37,41,52,94) Recently, there have been tremendous advances in the development of computer-based technologies with the ability to provide reproducible, quantitative assessments of th…”
MethodUltrahigh-resolution optical coherence tomography in glaucoma
Wollstein, G., Paunescu, L. A., Ko, T. H., Fujimoto, J. G., Kowalevicz, A. M., Hartl, I., Beaton, S. A., Ishikawa, H., Mattox, C. G., Singh, O. S., et al. (2004) · Ophthalmology · doi:10.1016/j.ophtha.2004.08.021 · Cited by 82 · cited 1×
“Studies comparing UHR OCT with standard OCT imaging found that ultrahigh-resolution enables improved visualization of intraretinal morphology and may enhance the clinical utility of standard OCT imaging for glaucoma.(142) Higher resolution OCT and larger datasets allow segmentation of retinal layers with high precisio…”
BackgroundSelf-citationMcKendrick, A. M., Badcock, D. R., & Morgan, W. H. (2004) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.03-1225 · Cited by 81
Reproducibility of evaluation of optic disc change for glaucoma with stereo optic disc photographs
Zeyen, T. G., Miglior, S., Pfeiffer, N., Cunha-Vaz, J. G., & Adamsons, I. A. (2003) · Ophthalmology · doi:10.1016/s0161-6420(02)01754-2 · Cited by 72 · cited 1×
“These studies have shown that by standardizing optic disk evaluation, photographs can be reproducibly evaluated.(107,152) Other level II studies have also overcome some of this variability by using a variety of methods to standardize optic disk evaluation.”
BackgroundMedeiros, F. A., Zangwill, L. M., Bowd, C., Bernd, A. S., & Weinreb, R. N. (2003) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.02-0814 · Cited by 71 · cited 1×
“978.(12,36,97) A study comparing GDx-VCC with RNFL photography found that although both techniques correlate with damage in corresponding hemiretinas, the best GDx-VCC parameter had a higher degree of discriminant ability than the best RNFL photographic parameter.”
Self-citationDiagnostic test analyses in search of their gold standard: latent class analyses with random effects
Goetghebeur, E. J. T., Liinev, J., Boelaert, M., & der Stuyft, P. V. (2000) · Statistical Methods in Medical Research · doi:10.1177/096228020000900304 · Cited by 69 · cited 1×
“An additional, albeit imperfect solution using the statistical technique of latent class or latent variable analysis may offer an approach to evaluation of glaucomatous damage or progression using multiple different types of observations, without the requirement for an a priori gold standard.(43)”
MethodIwase, A., Tomidokoro, A., Araie, M., Shirato, S., Shimizu, H., & Kitazawa, Y. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2006.06.041 · Cited by 62 · cited 1×
“FDT has been used for screening for glaucoma more often than other visual field test types and results support its usefulness.(63,85) Results obtained with Matrix perimetry have been shown to correlate highly with FDT perimetry,(113) suggesting that Matrix perimetry can be used similarly to FDT-N30 perimetry for detec…”
ResultStatistical aspects of the normal visual field in short-wavelength automated perimetry.
Wild, J. M., Cubbidge, R. P., Pacey, I. E., & Robinson, R. J. (1998) · PubMed · Cited by 62
Wu, L., Suzuki, Y., Kunimatsu‐Sanuki, S., Araie, M., Iwase, A., & Tomita, G. (2001) · Journal of Glaucoma · doi:10.1097/00061198-200108000-00002 · Cited by 53 · cited 1×
“Early evidence has shown the test may be more sensitive to early glaucomatous defect than is standard perimetry.(17,23,25,61,66,91,116,117,145) FDT has been used for screening for glaucoma more often than other visual field test types and results support its usefulness.”
BackgroundAgreement among 3 Optical Imaging Methods for the Assessment of Optic Disc Topography
mann, E. M. H., Bowd, C., Medeiros, F. A., Boden, C., Grus, F. H., Bourne, R., Zangwill, L. M., & Weinreb, R. N. (2005) · Ophthalmology · doi:10.1016/j.ophtha.2005.07.003 · Cited by 50
Self-citationde Alencar, L. M., Bowd, C., Weinreb, R. N., Zangwill, L. M., Sample, P. A., & Medeiros, F. A. (2008) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.07-0111 · Cited by 49
Self-citationSehi, M., Guaqueta, D. C., Feuer, W. J., & Greenfield, D. S. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2006.09.049 · Cited by 49 · cited 3×
“laser beam; when the polarized light passes through the birefringent RNFL, a measurable phase shift is created, which can be correlated to the RNFL thickness.(127) SLP was first commercially available as the GDx Nerve Fiber Analyzer (Laser Diagnostic Technologies, Inc.”
MethodGaasterland, D., Blackwell, B., Dally, L., Caprioli, J., Katz, L. J., & Ederer, F. (2001) · PubMed Central · Cited by 46
Mardin, C. Y., Hothorn, T., Peters, A., nemann, A. G. J., Nguyen, N. X., & Lausen, B. (2003) · Journal of Glaucoma · doi:10.1097/00061198-200308000-00008 · Cited by 39 · cited 1×
“Additionally, HRT assessments of the ONH are capable of distinguishing between healthy eyes and eyes with glaucomatous visual field defects, with a range of sensitivities from 51--97% and a range of specificities from 75--95%.(38,86,99,100,149) Furthermore, the OHTS reported many HRT parameters to be associated with t…”
BackgroundIntraocular pressure and visual field progression in open-angle glaucoma
Kass, M. A., & Gordon, M. O. (2000) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(00)00658-9 · Cited by 39
Glaucoma detection with matrix and standard achromatic perimetry
Burgansky–Eliash, Z., Wollstein, G., Patel, A., Bilonick, R. A., Ishikawa, H., Kagemann, L. E., Dilworth, W. D., & Schuman, J. S. (2007) · British Journal of Ophthalmology · doi:10.1136/bjo.2006.110437 · Cited by 36
Self-citationGirkin, C. A., DeLeón-Ortega, J., Xie, A., McGwin, G., Arthur, S. N., & Monheit, B. E. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2006.06.035 · Cited by 30 · cited 1×
“Other level II studies have also overcome some of this variability by using a variety of methods to standardize optic disk evaluation.(32,37,41,52,94) Recently, there have been tremendous advances in the development of computer-based technologies with the ability to provide reproducible, quantitative assessments of th…”
MethodMedeiros, F. A., Zangwill, L. M., Bowd, C., Vasile, C., Sample, P. A., & Weinreb, R. N. (2007) · Journal of Glaucoma · doi:10.1097/ijg.0b013e31802d695c · Cited by 23 · cited 2×
“shown that the diagnostic accuracy of photographs is comparable to HRT MRA classification(31,114) and that HRT linear C/D ratio measurements can be used interchangeably with stereophotograph C/D ratio measurements in the OHTS predictive models and risk calculator.(93) Limitations of the HRT include the requirement for…”
MethodSelf-citation
Cited by
Quigley, H. A. (2011) · The Lancet · doi:10.1016/s0140-6736(10)61423-7 · Cited by 1,121
Glaucoma risk index:Automated glaucoma detection from color fundus images
Bock, R., Meier, J., Nyúl, L. G., Hornegger, J., & Michelson, G. (2010) · Medical Image Analysis · doi:10.1016/j.media.2009.12.006 · Cited by 361
Linking structure and function in glaucoma
Harwerth, R. S., Wheat, J. L., Fredette, M. J., & Anderson, D. R. (2010) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2010.02.001 · Cited by 293
Takusagawa, H. L., Liu, L., Ma, K. N., Jia, Y., Gao, S. S., Zhang, M., Edmunds, B., Parikh, M., Tehrani, S., Morrison, J. C., et al. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2017.06.002 · Cited by 290
Decision support system for the glaucoma using Gabor transformation
Acharya, U. R., Ng, E. Y. K., Eugene, L. W. J., Noronha, K. P., Min, L. C., Nayak, K. P., & Bhandary, S. V. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2014.09.004 · Cited by 164
Metadata
- Authors
- Sharma, P., Sample, P. A., Zangwill, L. M., & Schuman, J. S.
- Venue
- Survey of Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2008-11
- Volume
- 53
- Issue
- 6
- Pages
- S17-S32
- ISSN
- 0039-6257 (ISSN-L)
- OpenAlex
- W2004041500
- Cited by
- 198
- References
- 83
- FWCI
- 6.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.