Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 936

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

How cryo-EM is revolutionizing structural biology

Bai, Xiao-chen, McMullan, Greg, Scheres, Sjors H.W·2015·Trends in Biochemical Sciences

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.tibs.2014.10.005

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 89

  1. Ruska, 1941, Über ein neues bei der bakteriophagen Lyse auftretendes Formelement, Naturwissenschaften, 29, 367, 10.1007/BF01479367 · DOI
  2. Ruska, 1939, Die Bedeutung der Übermikroskopie für die Virusforschung, Arch. Für Gesamte Virusforsch., 1, 155, 10.1007/BF01243399 · DOI
  3. Brenner, 1959, A negative staining method for high resolution electron microscopy of viruses, Biochim. Biophys. Acta, 34, 103, 10.1016/0006-3002(59)90237-9 · DOI · Paper page
  4. Henderson, 1975, Three-dimensional model of purple membrane obtained by electron microscopy, Nature, 257, 28, 10.1038/257028a0 · DOI · Paper page
  5. Unwin, 1975, Molecular structure determination by electron microscopy of unstained crystalline specimens, J. Mol. Biol., 94, 425, 10.1016/0022-2836(75)90212-0 · DOI · Paper page
  6. Taylor, 1974, Electron diffraction of frozen, hydrated protein crystals, Science, 186, 1036, 10.1126/science.186.4168.1036 · DOI · Paper page
  7. Hayward, 1979, Radiation damage of purple membrane at low temperature, Ultramicroscopy, 4, 201, 10.1016/S0304-3991(79)90211-0 · DOI
  8. Adrian, 1984, Cryo-electron microscopy of viruses, Nature, 308, 32, 10.1038/308032a0 · DOI · Paper page
  9. Dubochet, 1981, Low temperature electron microscopy, Annu. Rev. Biophys. Bioeng., 10, 133, 10.1146/annurev.bb.10.060181.001025 · DOI
  10. Dubochet, 1988, Cryo-electron microscopy of vitrified specimens, Q. Rev. Biophys., 21, 129, 10.1017/S0033583500004297 · DOI · Paper page
  11. Nogales, 1998, Structure of the alpha beta tubulin dimer by electron crystallography, Nature, 391, 199, 10.1038/34465 · DOI · Paper page
  12. Kühlbrandt, 1994, Atomic model of plant light-harvesting complex by electron crystallography, Nature, 367, 614, 10.1038/367614a0 · DOI · Paper page
  13. Gonen, 2005, Lipid-protein interactions in double-layered two-dimensional AQP0 crystals, Nature, 438, 633, 10.1038/nature04321 · DOI · Paper page
  14. Unwin, 2005, Refined structure of the nicotinic acetylcholine receptor at 4A resolution, J. Mol. Biol., 346, 967, 10.1016/j.jmb.2004.12.031 · DOI
  15. Zhou, 1993, Prospects for using an IVEM with a FEG for imaging macromolecules towards atomic resolution, Ultramicroscopy, 49, 407, 10.1016/0304-3991(93)90246-T · DOI
  16. Henderson, 1995, The potential and limitations of neutrons, electrons and X-rays for atomic resolution microscopy of unstained biological molecules, Q. Rev. Biophys., 28, 171, 10.1017/S003358350000305X · DOI · Paper page
  17. Böttcher, 1997, Determination of the fold of the core protein of hepatitis B virus by electron cryomicroscopy, Nature, 386, 88, 10.1038/386088a0 · DOI · Paper page
  18. Conway, 1997, Visualization of a 4-helix bundle in the hepatitis B virus capsid by cryo-electron microscopy, Nature, 386, 91, 10.1038/386091a0 · DOI
  19. Jiang, 2008, Backbone structure of the infectious epsilon15 virus capsid revealed by electron cryomicroscopy, Nature, 451, 1130, 10.1038/nature06665 · DOI
  20. Yu, 2008, 3.88 A structure of cytoplasmic polyhedrosis virus by cryo-electron microscopy, Nature, 453, 415, 10.1038/nature06893 · DOI · Paper page
  21. Zhang, 2008, Near-atomic resolution using electron cryomicroscopy and single-particle reconstruction, Proc. Natl. Acad. Sci. U.S.A., 105, 1867, 10.1073/pnas.0711623105 · DOI · Paper page
  22. Zhang, 2010, 3.3Å cryo-EM structure of a nonenveloped virus reveals a priming mechanism for cell entry, Cell, 141, 472, 10.1016/j.cell.2010.03.041 · DOI · Paper page
  23. Liu, 2010, Atomic structure of human adenovirus by cryo-EM reveals interactions among protein networks, Science, 329, 1038, 10.1126/science.1187433 · DOI · Paper page
  24. Verschoor, 1984, Three-dimensional reconstruction of the 30 S ribosomal subunit from randomly oriented particles, J. Mol. Biol., 178, 677, 10.1016/0022-2836(84)90245-6 · DOI
  25. Radermacher, 1987, Three-dimensional structure of the large ribosomal subunit from Escherichia coli, EMBO J., 6, 1107, 10.1002/j.1460-2075.1987.tb04865.x · DOI
  26. Frank, 1981, Computer averaging of electron micrographs of 40S ribosomal subunits, Science, 214, 1353, 10.1126/science.7313694 · DOI
  27. Van Heel, 1981, Use of multivariate statistics in analysing the images of biological macromolecules, Ultramicroscopy, 6, 187
  28. Harauz, 1986, Exact filters for general geometry three dimensional reconstruction, Optik, 73, 146
  29. Frank, 1987, On the correction of the contrast transfer function in biological electron microscopy, Optik, 98, 125
  30. Frank, 1991, Three-dimensional reconstruction of the 70S Escherichia coli ribosome in ice: the distribution of ribosomal RNA, J. Cell Biol., 115, 597, 10.1083/jcb.115.3.597 · DOI
  31. Gabashvili, 2000, Solution structure of the E. coli 70S ribosome at 11.5Å resolution, Cell, 100, 537, 10.1016/S0092-8674(00)80690-X · DOI · Paper page
  32. Hamilton, 1967, Image recording in electron microscopy, J. Opt. Soc. Am., 57, 232, 10.1364/JOSA.57.000232 · DOI
  33. McMullan, 2009, Detective quantum efficiency of electron area detectors in electron microscopy, Ultramicroscopy, 109, 1126, 10.1016/j.ultramic.2009.04.002 · DOI
  34. Roberts, 1982, A CCD-based image recording system for the CTEM, Ultramicroscopy, 8, 385, 10.1016/0304-3991(82)90061-4 · DOI
  35. Spence, 1988, Large dynamic range, parallel detection system for electron diffraction and imaging, Rev. Sci. Instrum., 59, 2102, 10.1063/1.1140039 · DOI
  36. Krivanek, 1993, Applications of slow-scan CCD cameras in transmission electron microscopy, Ultramicroscopy, 49, 95, 10.1016/0304-3991(93)90216-K · DOI
  37. Faruqi, 1999, Cooled CCD detector with tapered fibre optics for recording electron diffraction patterns, Ultramicroscopy, 75, 235, 10.1016/S0304-3991(98)00056-4 · DOI
  38. Suloway, 2005, Automated molecular microscopy: the new Leginon system, J. Struct. Biol., 151, 41, 10.1016/j.jsb.2005.03.010 · DOI · Paper page
  39. Sander, 2005, Advantages of CCD detectors for de novo three-dimensional structure determination in single-particle electron microscopy, J. Struct. Biol., 151, 92, 10.1016/j.jsb.2005.04.004 · DOI
  40. Booth, 2004, A 9 angstroms single particle reconstruction from CCD captured images on a 200kV electron cryomicroscope, J. Struct. Biol., 147, 116, 10.1016/j.jsb.2004.02.004 · DOI
  41. Faruqi, 2011, Electronic detectors for electron microscopy, Q. Rev. Biophys., 44, 357, 10.1017/S0033583511000035 · DOI
  42. Turchetta, 2001, A monolithic active pixel sensor for charged particle tracking and imaging using standard VLSI CMOS technology, Nucl. Instrum. Methods Phys. Res. Sect. Accel. Spectrometers Detect. Assoc. Equip., 458, 677, 10.1016/S0168-9002(00)00893-7 · DOI
  43. Milazzo, 2005, Active pixel sensor array as a detector for electron microscopy, Ultramicroscopy, 104, 152, 10.1016/j.ultramic.2005.03.006 · DOI
  44. Faruqi, 2005, Direct single electron detection with a CMOS detector for electron microscopy, Nucl. Instrum. Methods Phys. Res. Sect. Accel. Spectrometers Detect. Assoc. Equip., 546, 170, 10.1016/j.nima.2005.03.023 · DOI
  45. McMullan, 2009, Experimental observation of the improvement in MTF from backthinning a CMOS direct electron detector, Ultramicroscopy, 109, 1144, 10.1016/j.ultramic.2009.05.005 · DOI
  46. Ruskin, 2013, Quantitative characterization of electron detectors for transmission electron microscopy, J. Struct. Biol., 184, 385, 10.1016/j.jsb.2013.10.016 · DOI
  47. McMullan, 2014, Comparison of optimal performance at 300keV of three direct electron detectors for use in low dose electron microscopy, Ultramicroscopy, 147C, 156, 10.1016/j.ultramic.2014.08.002 · DOI
  48. Bichsel, 1988, Straggling in thin silicon detectors, Rev. Mod. Phys., 60, 663, 10.1103/RevModPhys.60.663 · DOI · Paper page
  49. McMullan, 2009, Enhanced imaging in low dose electron microscopy using electron counting, Ultramicroscopy, 109, 1411, 10.1016/j.ultramic.2009.07.004 · DOI
  50. Li, 2013, Electron counting and beam-induced motion correction enable near-atomic-resolution single-particle cryo-EM, Nat. Methods, 10, 584, 10.1038/nmeth.2472 · DOI
  51. Li, 2013, Influence of electron dose rate on electron counting images recorded with the K2 camera, J. Struct. Biol., 184, 251, 10.1016/j.jsb.2013.08.005 · DOI
  52. Gao, 2004, Dynamics of EF-G interaction with the ribosome explored by classification of a heterogeneous cryo-EM dataset, J. Struct. Biol., 147, 283, 10.1016/j.jsb.2004.02.008 · DOI
  53. Valle, 2002, Cryo-EM reveals an active role for aminoacyl-tRNA in the accommodation process, EMBO J., 21, 3557, 10.1093/emboj/cdf326 · DOI · Paper page
  54. Sigworth, 1998, A maximum-likelihood approach to single-particle image refinement, J. Struct. Biol., 122, 328, 10.1006/jsbi.1998.4014 · DOI · Paper page
  55. Scheres, 2007, Disentangling conformational states of macromolecules in 3D-EM through likelihood optimization, Nat. Methods, 4, 27, 10.1038/nmeth992 · DOI · Paper page
  56. Elad, 2008, Detection and separation of heterogeneity in molecular complexes by statistical analysis of their two-dimensional projections, J. Struct. Biol., 162, 108, 10.1016/j.jsb.2007.11.007 · DOI
  57. Zhang, 2008, Heterogeneity of large macromolecular complexes revealed by 3D cryo-EM variance analysis, Structure, 16, 1770, 10.1016/j.str.2008.10.011 · DOI
  58. Spahn, 2009, Exploring conformational modes of macromolecular assemblies by multiparticle cryo-EM, Curr. Opin. Struct. Biol., 19, 623, 10.1016/j.sbi.2009.08.001 · DOI
  59. Lyumkis, 2013, Likelihood-based classification of cryo-EM images using FREALIGN, J. Struct. Biol., 183, 377, 10.1016/j.jsb.2013.07.005 · DOI · Paper page
  60. Scheres, 2012, A Bayesian view on cryo-EM structure determination, J. Mol. Biol., 415, 406, 10.1016/j.jmb.2011.11.010 · DOI · Paper page
  61. Brilot, 2012, Beam-induced motion of vitrified specimen on holey carbon film, J. Struct. Biol., 177, 630, 10.1016/j.jsb.2012.02.003 · DOI · Paper page
  62. Campbell, 2012, Movies of ice-embedded particles enhance resolution in electron cryo-microscopy, Structure, 20, 1823, 10.1016/j.str.2012.08.026 · DOI · Paper page
  63. Bai, 2013, Ribosome structures to near-atomic resolution from thirty thousand cryo-EM particles, Elife, 2, e00461, 10.7554/eLife.00461 · DOI · Paper page
  64. Cao, 2013, TRPV1 structures in distinct conformations reveal activation mechanisms, Nature, 504, 113, 10.1038/nature12823 · DOI · Paper page
  65. Liao, 2013, Structure of the TRPV1 ion channel determined by electron cryo-microscopy, Nature, 504, 107, 10.1038/nature12822 · DOI
  66. Allegretti, 2014, Atomic model of the F420-reducing [NiFe] hydrogenase by electron cryo-microscopy using a direct electron detector, Elife, 3, e01963, 10.7554/eLife.01963 · DOI
  67. Amunts, 2014, Structure of the yeast mitochondrial large ribosomal subunit, Science, 343, 1485, 10.1126/science.1249410 · DOI · Paper page
  68. Emsley, 2010, Features and development of Coot, Acta Crystallogr. D: Biol. Crystallogr., 66, 486, 10.1107/S0907444910007493 · DOI · Paper page
  69. Murshudov, 1997, Refinement of macromolecular structures by the maximum-likelihood method, Acta Crystallogr. Sect. D, 53, 240, 10.1107/S0907444996012255 · DOI · Paper page
  70. DiMaio, 2013, Cryo-EM model validation using independent map reconstructions, Protein Sci., 22, 865, 10.1002/pro.2267 · DOI · Paper page
  71. Falkner, 2013, Cross-validation in cryo-EM-based structural modeling, Proc. Natl. Acad. Sci. U.S.A., 110, 8930, 10.1073/pnas.1119041110 · DOI
  72. Wong, 2014, Cryo-EM structure of the Plasmodium falciparum 80S ribosome bound to the anti-protozoan drug emetine, Elife, 10.7554/eLife.03080 · DOI · Paper page
  73. Lu, 2014, Three-dimensional structure of human γ-secretase, Nature, 512, 166, 10.1038/nature13567 · DOI · Paper page
  74. Scheres, 2014, Beam-induced motion correction for sub-megadalton cryo-EM particles, Elife, 3, e03665, 10.7554/eLife.03665 · DOI · Paper page
  75. Fernández, 2013, Molecular architecture of a eukaryotic translational initiation complex, Science, 342, 1240585, 10.1126/science.1240585 · DOI
  76. Koh, 2014, Taura syndrome virus IRES initiates translation by binding its tRNA-mRNA-like structural element in the ribosomal decoding center, Proc. Natl. Acad. Sci. U.S.A., 111, 9139, 10.1073/pnas.1406335111 · DOI
  77. Fernández, 2014, Initiation of translation by cricket paralysis virus IRES requires its translocation in the ribosome, Cell, 157, 823, 10.1016/j.cell.2014.04.015 · DOI
  78. Stark, 1996, Electron radiation damage to protein crystals of bacteriorhodopsin at different temperatures, Ultramicroscopy, 63, 75, 10.1016/0304-3991(96)00045-9 · DOI
  79. Sader, 2013, Cryomicroscopy of radiation sensitive specimens on unmodified graphene sheets: reduction of electron-optical effects of charging, J. Struct. Biol., 183, 531, 10.1016/j.jsb.2013.04.014 · DOI
  80. Russo, 2014, Controlling protein adsorption on graphene for cryo-EM using low-energy hydrogen plasmas, Nat. Methods, 11, 649, 10.1038/nmeth.2931 · DOI
  81. Marr, 2014, Fabrication of carbon films with ∼500nm holes for cryo-EM with a direct detector device, J. Struct. Biol., 185, 42, 10.1016/j.jsb.2013.11.002 · DOI
  82. Berriman, 2012, Paraxial charge compensator for electron cryomicroscopy, Ultramicroscopy, 116, 106, 10.1016/j.ultramic.2012.03.006 · DOI
  83. Grigorieff, 2007, FREALIGN: high-resolution refinement of single particle structures, J. Struct. Biol., 157, 117, 10.1016/j.jsb.2006.05.004 · DOI · Paper page
  84. Ludtke, 1999, EMAN: semiautomated software for high-resolution single-particle reconstructions, J. Struct. Biol., 128, 82, 10.1006/jsbi.1999.4174 · DOI
  85. Liu, 2007, Averaging tens to hundreds of icosahedral particle images to resolve protein secondary structure elements using a Multi-Path Simulated Annealing optimization algorithm, J. Struct. Biol., 160, 11, 10.1016/j.jsb.2007.06.009 · DOI
  86. Kostyuchenko, 2014, Near-atomic resolution cryo-electron microscopic structure of dengue serotype 4 virus, J. Virol., 88, 477, 10.1128/JVI.02641-13 · DOI
  87. Veesler, 2013, Atomic structure of the 75MDa extremophile Sulfolobus turreted icosahedral virus determined by CryoEM and X-ray crystallography, Proc. Natl. Acad. Sci. U.S.A., 110, 5504, 10.1073/pnas.1300601110 · DOI
  88. Van Heel, 1996, A new generation of the IMAGIC image processing system, J. Struct. Biol., 116, 17, 10.1006/jsbi.1996.0004 · DOI · Paper page
  89. Greber, 2013, Architecture of the large subunit of the mammalian mitochondrial ribosome, Nature, 505, 515, 10.1038/nature12890 · DOI

Cited by

See all 936

Metadata

Authors
Bai, X.-C., McMullan, G., & Scheres, S. H. W.
Venue
Trends in Biochemical Sciences
Publisher
Elsevier BV
Published
2015-01
Volume
40
Issue
1
Pages
49-57
ISSN
0968-0004 (ISSN-L)
OpenAlex
W2072404529
Cited by
936
References
2
FWCI
4.87
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.