Ultrasonic transcutaneous energy transfer for powering implanted devices
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fundamentals of Power Electronics
Erickson, R. W., & Maksimović, D. (2020) · Springer eBooks · doi:10.1007/978-3-030-43881-4 · Cited by 5,420
New equivalent circuits for elementary piezoelectric transducers
Krimholtz, R., Leedom, D. A., & Matthaei, G. L. (1970) · Electronics Letters · doi:10.1049/el:19700280 · Cited by 810
Diagnostic ultrasound : physics and equipment
Hoskins, P. R., Martin, K., & Thrush, A. J. (2010) · Cited by 302
Transmitting electric energy through a metal wall by acoustic waves using piezoelectric transducers
Hu, Y., Zhang, X., Yang, J., & Jiang, Q. (2003) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2003.1214497 · Cited by 171
Design of Ultrasonic Transducers with Multiple Acoustic Matching Layers for Medical Application
Inoue, T., Ohta, M., & Takahashi, S. (1987) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/t-uffc.1987.26905 · Cited by 75 · cited 1×
“Multiple matching layer techniques have been proposed in [16].”
BackgroundMatching ultrasonic transducer using two matching layers where one of them is glue
Callens, D., Bruneel, C., & Assaad, J. (2004) · NDT & E International · doi:10.1016/j.ndteint.2004.03.005 · Cited by 63 · cited 4×
“Reflection coefficient when using two layer matching to represent a linear network having complex two port properties as described by [21]:”
BackgroundMethodInfluentialCochran, G. V. B., Kadaba, M. P., & Palmieri, V. R. (1988) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100060119 · Cited by 39 · cited 1×
“This paper proposes a UTET device in which the energy is transmitted via an acoustic wave as previously suggested to stimulate bone healing [5].”
BackgroundA theory for optimization in the use of acoustic emission transducers
Hill, R., & El-Dardiry, S. M. A. (1980) · The Journal of the Acoustical Society of America · doi:10.1121/1.383893 · Cited by 35
Cited by
Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557
“In contrast to EM, ultrasound offers an attractive alternative for wirelessly powering and communicating with sub-mm implantable devices (Charthad et al., 2015; Larson and Towe, 2011; Meng and Sahin 2013; Ozeri and Shmilovitz, 2010; Seo et al., 2014).”
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Power Approaches for Implantable Medical Devices
Amar, A., Kouki, A., & Cao, H. (2015) · Sensors · doi:10.3390/s151128889 · Cited by 432
From Wearable Sensors to Smart Implants-–Toward Pervasive and Personalized Healthcare
Andreu-Perez, J., Leff, D. R., Ip, H. M. D., & Yang, G.-Z. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2422751 · Cited by 383
Wireless power transfer techniques for implantable medical devices: a review
Khan, S. R., Pavuluri, S. K., Cummins, G., & Desmulliez, M. P. Y. (2020) · Sensors · doi:10.3390/s20123487 · Cited by 355
Akhtar, F., & Rehmani, M. H. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.02.021 · Cited by 348
A Review of Acoustic Impedance Matching Techniques for Piezoelectric Sensors and Transducers
Rathod, V. T. (2020) · Sensors · doi:10.3390/s20144051 · Cited by 328
Acoustically powered surface-slipping mobile microrobots
Aghakhani, A., Yasa, O., Wrede, P., & Sitti, M. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1920099117 · Cited by 321
Micro triboelectric ultrasonic device for acoustic energy transfer and signal communication
Chen, C., Wen, Z., Shi, J., Jian, X., Li, P., Yeow, J. T. W., & Sun, X. (2020) · Nature Communications · doi:10.1038/s41467-020-17842-w · Cited by 284
A Review of In-Body Biotelemetry Devices: Implantables, Ingestibles, and Injectables
Kiourti, A., & Nikita, K. S. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2668612 · Cited by 278
Roy, S., Azad, A. N. M. W., Baidya, S., Alam, M. K., & Khan, F. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3164890 · Cited by 255
Review of Near-Field Wireless Power and Communication for Biomedical Applications
Kim, H.-J., Hirayama, H., Kim, S., Han, K. J., Zhang, R., & Choi, J.-W. (2017) · IEEE Access · doi:10.1109/access.2017.2757267 · Cited by 252
“The power reception also shows significant vulnerability to misalignment between transmitter (Tx) and receiver (Rx) [23].”
BackgroundCharthad, J., Weber, M. J., Chang, T. C., & Arbabian, A. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2427336 · Cited by 245
Light Technology for Efficient and Effective Photodynamic Therapy: A Critical Review
Algorri, J. F., Ochoa, M., Roldán-Varona, P., Rodríguez-Cobo, L., & López-Higuera, J. M. (2021) · Cancers · doi:10.3390/cancers13143484 · Cited by 245
Shi, Q., Wang, T., & Lee, C. (2016) · Scientific Reports · doi:10.1038/srep24946 · Cited by 210
A review of acoustic power transfer for bio-medical implants
Basaeri, H., Christensen, D. B., & Roundy, S. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/12/123001 · Cited by 202
Ultrasonic vs. Inductive Power Delivery for Miniature Biomedical Implants
Denisov, A., & Yeatman, E. (2010) · 2010 International Conference on Body Sensor Networks · doi:10.1109/bsn.2010.27 · Cited by 190
“investigated an ultrasonic transcutaneous energy transfer for wireless power delivery to implanted microdevices [12].”
BackgroundWireless power transfer approaches for medical implants: a review
Haerinia, M., & Shadid, R. (2020) · Signals · doi:10.3390/signals1020012 · Cited by 174
“[105] 2010 673 kHz 1000 27 40 [106] 2003 100 kHz 5400 36 40 [25] 2002 1 MHz 2100 20 40 [26] 2001 1 MHz 20 30 * Width and total length of 48 symmetric elements of the spherical transducer array.”
Neural Dust: An Ultrasonic, Low Power Solution for Chronic Brain-Machine Interfaces
Seo, D., Carmena, J. M., Rabaey, J. M., Alon, E., & Maharbiz, M. M. (2013) · arXiv · doi:10.48550/arxiv.1307.2196 · Cited by 172
Additive manufacturing of hydrogel-based materials for next-generation implantable medical devices
Chin, S. Y., Poh, Y. C., Kohler, A.-C., Compton, J. T., Hsu, L. L., Lau, K. M., Kim, S., Lee, B. W., Lee, F. Y., & Sia, S. K. (2017) · Science Robotics · doi:10.1126/scirobotics.aah6451 · Cited by 172
Functionalized multiwalled carbon nanotubes as ultrasound contrast agents
Delogu, L. G., Vidili, G., Venturelli, E., Ménard-Moyon, C., Zoroddu, M. A., Pilo, G., Nicolussi, P., Ligios, C., Bedognetti, D., Sgarrella, F., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1208312109 · Cited by 164
Miniaturised wireless power transfer systems for neurostimulation: a review
Barbruni, G. L., Ros, P. M., Demarchi, D., Carrara, S., & Ghezzi, D. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3038599 · Cited by 161
“In literature several techniques were proposed to overcome the acoustic impedance mismatch [78].”
BackgroundWireless technologies for implantable devices
Nelson, B. D., Karipott, S. S., Wang, Y., & Ong, K. G. (2020) · Sensors · doi:10.3390/s20164604 · Cited by 125
“2 MHz [53] 1 MHz–3 GHz [54] 220 THz–460 THz [55] Receiver Piezoelectric element Antenna Photovoltaic cell Depth Over 10 cm [56] Up to 5 cm [57] Less than 5 mm Misalignment Resilience Moderate Very Low Low”
BackgroundInfluentialProto, A., Rufer, L., Basrour, S., & Penhaker, M. (2022) · Micromachines · doi:10.3390/mi13122127 · Cited by 23
“In 2010, Ozeri and Shmilovitz [15] proposed the most effective UPD system ever seen before.”
BackgroundUltrasound powered implants: design, performance considerations and simulation results
Rosa, B. M. G., & Yang, G.-Z. (2020) · Scientific Reports · doi:10.1038/s41598-020-63097-2 · Cited by 18
Metadata
- Authors
- Ozeri, S., & Shmilovitz, D.
- Venue
- Ultrasonics
- Publisher
- Elsevier BV
- Published
- 2010-05
- Volume
- 50
- Issue
- 6
- Pages
- 556-566
- ISSN
- 0041-624X (ISSN-L)
- OpenAlex
- W2004771128
- Cited by
- 240
- References
- 8
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.