Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical model
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
It recently has been demonstrated that magnetic resonance imaging can be used to map changes in brain hemodynamics produced by human mental operations. One method under development relies on blood oxygenation level-dependent (BOLD) contrast: a change in the signal strength of brain water protons produced by the paramagnetic effects of venous blood deoxyhemoglobin. Here we discuss the basic quantitative features of the observed BOLD-based signal changes, including the signal amplitude and its magnetic field dependence and dynamic effects such as a pronounced oscillatory pattern that is induced in the signal from primary visual cortex during photic stimulation experiments. The observed features are compared with the results of Monte Carlo simulations of water proton intravoxel phase dispersion produced by local field gradients generated by paramagnetic deoxyhemoglobin in nearby venous blood vessels. The simulations suggest that the effect of water molecule diffusion is strong for the case of blood capillaries, but, for larger venous blood vessels, water diffusion is not an important determinant of deoxyhemoglobin-induced signal dephasing. We provide an expression for the apparent in-plane relaxation rate constant (R2*) in terms of the main magnetic field strength, the degree of the oxygenation of the venous blood, the venous blood volume fraction in the tissue, and the size of the blood vessel.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Additionally, higher fields increase the relative sensitivity to the microvasculature in BOLD-based functional images (Uludag et al., 2009; Ugurbil et al., 2003b; Ogawa et al., 1993), resulting in a smaller point spread function (Shmuel et al., 2007).”
From The WU-Minn Human Connectome Project: An overview (2013) · cites this paper as Ogawa et al., 1993
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Self-citationDynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Self-citationOxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
Ogawa, S., Lee, T., Nayak, A. S., & Glynn, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140108 · Cited by 2,266
Self-citationFox, P. T., & Raichle, M. E. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.4.1140 · Cited by 2,056
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Nonoxidative Glucose Consumption During Focal Physiologic Neural Activity
Fox, P. T., Raichle, M. E., Mintun, M. A., & Dence, C. (1988) · Science · doi:10.1126/science.3260686 · Cited by 1,796
The Magnetic Properties and Structure of Hemoglobin, Oxyhemoglobin and Carbonmonoxyhemoglobin
Pauling, L., & Coryell, C. D. (1936) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.22.4.210 · Cited by 1,159
Perfusion imaging with NMR contrast agents
Rosen, B. R., Belliveau, J. W., Vevea, J. M., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140211 · Cited by 1,151
Cited by
Items 901–1,000 of 1,001
Cerebral blood volume measurements by rapid contrast infusion and T‐weighted echo planar MRI
Tudorica, A., Li, H. F., Hospod, F. E., Delucia‐Deranja, E., Huang, W., Patlak, C. S., & Newman, G. C. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10167 · Cited by 23
Salle, F. D., Esposito, F., Elefante, A., Scarabino, T., Volpicelli, A., Cirillo, S., Elefante, R., & Seifritz, E. (2003) · European Journal of Radiology · doi:10.1016/j.ejrad.2003.08.010 · Cited by 23
“Specifically, as stated above, voxels containing vessels larger than the voxel itself go less than linearly while voxels containing capillaries and veins/venules with a diameter less than that of the voxel itself go greater than linearly [27,28].”
BackgroundInfluentialMeasuring venous blood volume changes during activation using hyperoxia
Blockley, N. P., Driver, I. D., Fisher, J. A., Francis, S., & Gowland, P. A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.041 · Cited by 23
“Blood oxygenation level dependent (BOLD) contrast is primarily a function of venous blood oxygenation and venous cerebral blood volume (CBVv) (Ogawa et al., 1993).”
The BOLD sensitivity of rapid steady‐state sequences
Scheffler, K., Heule, R., Báez‐Yáñez, M. G., Kardatzki, B., & Lohmann, G. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27585 · Cited by 23
de Labra, C., Rivadulla, C., Espinosa, N., Dasilva, M., Cao, R., & Cudeiro, J. (2009) · Frontiers in Systems Neuroscience · doi:10.3389/neuro.06.009.2009 · Cited by 23
Small animal neuroimaging using magnetic resonance microscopy
Ahrens, E. T., Narasimhan, P. T., Nakada, T., & Jacobs, R. E. (2002) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/s0079-6565(02)00003-1 · Cited by 24
fMRI of the auditory cortex in patients with unilateral carotid artery steno‐occlusive disease
Bilecen, D., Radue, E. W., Schulte, A., Hennig, J., Scheffler, K., & Seifritz, E. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10117 · Cited by 23
Mapping of the cerebral response to hypoxia measured using graded asymmetric spin echo EPI
Houston, G. C., Papadakis, N. G., Carpenter, T. A., Hall, L. D., Mukherjee, B., James, M. F., & Huang, C. L.-H. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(00)00196-x · Cited by 23
Le, T. T., Im, G. H., Lee, C. H., Choi, S., & Kim, S. (2024) · Science Advances · doi:10.1126/sciadv.adm7605 · Cited by 22
“Total CBV and CBF measured by GE-BOLD data collection contain large vessels (red voxels indicated by red arrows), which are mostly removed using SE-BOLD data detection ( 31–33 ).”
MethodSelf-citationSusceptibility‐based analysis of dynamic gadolinium bolus perfusion MRI
Bonekamp, D., Barker, P. B., Leigh, R. J., van Zijl, P. C. M., & Li, X. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25144 · Cited by 22
Cerebrovascular Reactivity Assays Collateral Function in Carotid Stenosis
Sobczyk, O., Sam, K., Mandell, D. M., Crawley, A. P., Venkatraghavan, L., McKetton, L., Poublanc, J., Duffin, J., Fisher, J. A., & Mikulis, D. J. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.01031 · Cited by 22
Hulvershorn, J., Bloy, L., Gualtieri, E., Redmann, C. P., LEIGH, J. S. J., & Elliott, M. A. (2005) · Human Brain Mapping · doi:10.1002/hbm.20094 · Cited by 22
“The most frequently used sequence in functional studies, gradient-echo (GE) echo planar imaging (EPI), is particularly sensitive to changes in the oxygenation state of hemoglobin, commonly referred to as blood oxygenation level-dependent (BOLD) contrast [Ogawa et al., 1990, 1993].”
MethodOgura, E., Matsuyama, M., Goto, T. K., Nakamura, Y., & Koyano, K. (2011) · Dysphagia · doi:10.1007/s00455-011-9374-9 · Cited by 22
“With the development of functional magnetic resonance imaging (fMRI), brain activity can be visualized using the blood oxygen level-dependent (BOLD) signal [3, 4].”
MethodPoser, B. A., van Mierlo, E., & Norris, D. G. (2010) · Human Brain Mapping · doi:10.1002/hbm.21003 · Cited by 22
“The loss of phase coherence hence becomes stochastic and can no longer be refocused by a spin echo; this contrast mechanism is called extravascular dynamic dephasing and constitutes a T2 effect [Ogawa et al., 1993].”
BackgroundNMR Simulation Analysis of Statistical Effects on Quantifying Cerebrovascular Parameters
Klassen, L. M., & Menon, R. S. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.087965 · Cited by 22
“The first Monte Carlo (MC) model was developed by Ogawa et al to quantify the BOLD effect (9) and a refined MC simulation was developed by Boxerman et al (10).”
MethodSelf-citationBrain Activity During the Clock-Drawing Test: Multichannel Near-Infrared Spectroscopy Study
Shoyama, M., Nishioka, T., Okumura, M., Kose, A., Tsuji, T., Ukai, S., & Shinosaki, K. (2011) · Applied Neuropsychology · doi:10.1080/09084282.2011.595450 · Cited by 22
“NIRS measures such hemodynamic responses to neuronal activities based on changes in both oxy-hemoglobin (oxy-Hb) and deoxy-hemoglobin (deoxy-Hb), whereas fMRI uses blood–oxygen level-dependent (BOLD) signals that are mainly sensitive to the deoxy-Hb and to the blood flow (Ogawa et al., 1993).”
MethodNew horizons in neurometabolic and neurovascular coupling from calibrated fMRI
Shu, C. Y., Sanganahalli, B. G., Coman, D., Hermán, P., & Hyder, F. (2016) · Progress in brain research · doi:10.1016/bs.pbr.2016.02.003 · Cited by 22
Kallioniemi, E., Pitkänen, M., Könönen, M., Vanninen, R., & Julkunen, P. (2016) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2016.09.002 · Cited by 22
The BOLD response: a new look at an old riddle
Marcar, V. L., & Loenneker, T. (2004) · Neuroreport · doi:10.1097/00001756-200409150-00001 · Cited by 22
“THEBOLDSIGNAL The BOLD signal is a modulation of the MR signal with the oxygen content of the blood [2].”
BackgroundPerfusion‐based functional magnetic resonance imaging
Silva, A. C., & Kim, S. (2003) · Concepts in Magnetic Resonance Part A · doi:10.1002/cmr.a.10050 · Cited by 22
Self-citationPrice, W. S. (1998) · Annual reports on NMR spectroscopy · doi:10.1016/s0066-4103(08)60113-1 · Cited by 24
The Roles of Functional MRI in MR-Guided Neurosurgery in a Combined 1.5 Tesla MR-Operating Room
Liu, H., Hall, W. A., & Truwit, C. L. (2003) · Acta neurochirurgica. Supplementum · doi:10.1007/978-3-7091-6043-5_18 · Cited by 22
Introduction to the special issue on neuro‐information science
Jacek Gwizdka, A., Moshfeghi, Y., & Wilson, M. L. (2019) · Journal of the Association for Information Science and Technology · doi:10.1002/asi.24263 · Cited by 22
“…magnetic resonance imaging, or fMRI, measures brain activity (Soares et al., 2016) using the blood oxygen level-dependent (BOLD) signal, which is generated by a complex process related to blood flow, blood volume, and the ratio of oxygenated blood to deoxygenated blood (Ogawa et al., 1993).”
Ultra high resolution fMRI at ultra-high field
Harel, N. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.018 · Cited by 21
“In addition, theoretical work had predicted that spin-echo (SE) BOLD will have better specificity at high magnetic fields when compared with GE-BOLD although at the cost of a decrease in the magnitude of signal changes (Ogawa et al., 1993) (Boxerman et al., 1995).”
Decreasing cerebral oxygen consumption during upright tilt in vasovagal syncope
Medow, M. S., Kothari, M. L., Goetz, A. M., O’Donnell-Smith, M. B., Terilli, C., & Stewart, J. M. (2017) · Physiological Reports · doi:10.14814/phy2.13286 · Cited by 21
“CBFv, DHb, DHbO2, arterial, and venous hemoglobin saturations change relatively slowly compared with tissue oxygen profiles permitting the use of steady-state kinetics to estimate time varying CMRO2 such that (Ogawa et al. 1993; Jones et al. 2001; Mayhew et al. 2001; Boas et al. 2003)”
BackgroundKronenbuerger, M., Hua, J., Bang, J., Ultz, K. E., Miao, X., Zhang, X., Pekar, J. J., van Zijl, P. C. M., Duan, W., Margolis, R. L., et al. (2019) · Neurodegenerative Diseases · doi:10.1159/000501616 · Cited by 21
Zhang, Y., Sun, J., & Rolfe, P. J. (2010) · Journal of Modern Optics · doi:10.1080/09500340.2010.531152 · Cited by 21
Investigating the field-dependence of the Davis model: Calibrated fMRI at 1.5, 3 and 7 T
Hare, H. V., Blockley, N. P., Gardener, A. G., Clare, S., & Bulte, D. P. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.02.068 · Cited by 21
“Extravascular signals (Se) were modelled using the results of numerical simulations for two vessel scales to reflect the different signal characteristics of capillaries (β = 2) compared with arteries and veins (β = 1) (Ogawa et al., 1993).”
Modeling of Cellular Metabolism and Microcirculatory Transport
Beard, D. A., Wu, F., Cabrera, M. E., & Dash, R. K. (2008) · Microcirculation · doi:10.1080/10739680802019709 · Cited by 21
“This type of phenomenological modeling of oxygen metabolism is used, for example, in the analysis of experimental data from positron emission tomography (PET) and nuclear magnetic resonance (NMR) imaging to estimate regional oxygen consumption in the heart [44,15,27] and brain [39,55,56].”
MethodComprehending auditory speech: previous and potential contributions of functional MRI
Evans, S., & McGettigan, C. (2017) · Language Cognition and Neuroscience · doi:10.1080/23273798.2016.1272703 · Cited by 21
“…the finding that deoxygenated and oxygenated haemoglobin have different properties in a magnetic field – the former paramagnetic, the latter diamagnetic (Bandettini, Wong, Hinks, Tikofsky, & Hyde, 1992; Kwong et al., 1992; Logothetis, Pauls, Augath, Trinath, & Oeltermann, 2001; Ogawa et al., 1993).”
BackgroundFerreira, P., Gatehouse, P. D., Bucciarelli‐Ducci, C., Wage, R., & Firmin, D. N. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21723 · Cited by 21
BOLD fMRI using a modified HASTE sequence
Ye, Y., Zhuo, Y., Xue, R., & Zhou, X. J. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.07.044 · Cited by 21
“Such changes occur in both brain parenchyma (e.g., the gray matter) and blood, making fMRI signals sensitive to not only neuronal activation but also to hemodynamic modulations (e.g., blood flow) (Ogawa and Lee, 1990; Ogawa et al., 1993).”
Functional MR Imaging at 3.0 T versus 1.5 T: A Practical Review
Voss, H. U., Zevin, J. D., & McCandliss, B. D. (2006) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2006.02.008 · Cited by 21
Lee, J.-M., Hu, J., Gao, J., Crosson, B., Peck, K. K., Wierenga, C. E., McGregor, K., Zhao, Q. C., & White, K. D. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.11.016 · Cited by 21
“The basis for fMRI is blood oxygenation level-dependent or BOLD contrast (Ogawa et al., 1993).”
Functional Magnetic Resonance Imaging and its Clinical Utility in Patients with Visual Disturbances
Miki, A., Haselgrove, J. C., & Liu, G. T. (2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00356-9 · Cited by 21
Kim, S., & Bandettini, P. A. (2010) · Springer eBooks · doi:10.1007/978-1-4419-1329-6_1 · Cited by 21
Self-citationFunctional Neuroimaging of Spike-Wave Seizures
Motelow, J. E., & Blumenfeld, H. (2008) · Methods in molecular biology · doi:10.1007/978-1-59745-543-5_9 · Cited by 21
Sharma, R. D., & Sharma, A. K. (2004) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-3-13 · Cited by 21
RetractedTucker, A. M., Rakitin, B. C., Basner, R. C., Gazes, Y., Steffener, J., & Stern, Y. (2010) · Behavioural Brain Research · doi:10.1016/j.bbr.2010.11.012 · Cited by 20
The mass transfer coefficient for oxygen transport from blood to tissue in cerebral cortex
Secomb, T. W., Katherine, B., Boas, D. A., & Sakadžić, S. (2019) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x19870068 · Cited by 20
Monaco, S., Malfatti, G., Zendron, A., Pellencin, E., & Turella, L. (2019) · Brain Structure and Function · doi:10.1007/s00429-019-01970-1 · Cited by 20
Lo, M.-Y., Ong, M. W., Chen, W.-Y., Sun, W., & Lin, J. (2015) · Evidence-based Complementary and Alternative Medicine · doi:10.1155/2015/839470 · Cited by 20
Clinical Functional Magnetic Resonance Imaging
Hart, J., Rao, S. M., & Nuwer, M. R. (2007) · Cognitive and Behavioral Neurology · doi:10.1097/wnn.0b013e31812570e2 · Cited by 20
“The minimal work that is necessary to bill for 96020 is the following: (1) administration of at least 2 cognitive tests with the minimum of one of those tasks assessing a higher cognitive function such as, but not limited to, orientation, attention, memory, language, visuospatial function, executive functions, decisio…”
BackgroundFunctional neuroimaging of inner fields-of-view with 2D-selective RF excitations
Finsterbusch, J. (2013) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2013.03.005 · Cited by 20
Ho, Y.-C. L., Vidyasagar, R., Shen, Y., Balanos, G. M., Golay, X., & Kauppinen, R. A. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.02.048 · Cited by 20
“During brain activation, oxygen saturation changes are substantial in veins and thus, the T2⁎ of venous blood has to be estimated (Ogawa et al., 1993), particularly with imperfect blood nulling.”
Volumetric BOLD fMRI simulation: from neurovascular coupling to multivoxel imaging
Chen, Z., & Calhoun, V. D. (2012) · BMC Medical Imaging · doi:10.1186/1471-2342-12-8 · Cited by 20
“The volumetric computational model can be considered as a generalization of the single voxel neurovascular coupling model (Δc = cdo⋅Hct⋅(1-Y)) that has been accepted for single voxel BOLD signal simulation [1,3,17,23].”
BackgroundMethodRemington, L. A. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4377-1926-0.10013-x · Cited by 20
Takamoto, K., Hori, E., Urakawa, S., Katayama, M., Nagashima, Y., Yada, Y., Ono, T., & Nishijo, H. (2013) · Psychophysiology · doi:10.1111/j.1469-8986.2012.01488.x · Cited by 20
The effects of K-space data undersampling and discontinuities in keyhole functional MRI
Xiong, J., Fox, P. T., & Gao, J. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)00147-7 · Cited by 20
Gozzi, A., Schwarz, A. J., Reese, T., Crestan, V., Bertani, S., Turrini, G., Corsi, M., & Bifone, A. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.08.013 · Cited by 20
Yamauchi, H., Okazawa, H., Kishibe, Y., Sugimoto, K., & Takahashi, M. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00283-0 · Cited by 20
“If the relationship between the CBF and CMRO2 responses were to change, the interpretation of the neural activation-related BOLD signal change would become difficult, because the BOLD signal is the convolution of several components, including CBF, CMRO2, and cerebral blood volume (CBV), and the change in CMRO2/CBF pro…”
BackgroundAn Introduction to Normalization and Calibration Methods in Functional MRI
Liu, T. T., Glover, G. H., Mueller, B. A., Greve, D. N., & Brown, G. G. (2013) · Psychometrika · doi:10.1007/s11336-012-9309-x · Cited by 20
Yang, J., & Shen, J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.05.010 · Cited by 20
“This uncoupling between oxidative metabolism and CBF has been used to explain the origin of the positive BOLD signal (Ogawa et al., 1993).”
MethodWedegärtner, U., Tchirikov, M., Schäfer, S., Priest, A. N., Walther, M., Adam, G., & Schröder, H. J. (2005) · Radiology · doi:10.1148/radiol.2373041625 · Cited by 20
Jones, R. A., Müller, T. B., Haraldseth, O., Baptista, A. M., & Øksendal, A. N. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350407 · Cited by 20
Experiences with functional magnetic resonance imaging at 1 tesla.
Jones, A. P., Hughes, D. G., Brettle, D. S., Robinson, L., Sykes, J. R., Aziz, Q., Hamdy, S., Thompson, D. G., Derbyshire, S. W. G., Chen, A. C. N., et al. (1998) · British Journal of Radiology · doi:10.1259/bjr.71.842.9579180 · Cited by 20
Fast Functional Magnetic Resonance Imaging via Prolate Wavelets
Shepp, L. A., & Zhang, C.-H. (2000) · Applied and Computational Harmonic Analysis · doi:10.1006/acha.2000.0302 · Cited by 20
Visual Activation in Functional Magnetic Resonance Imaging at Very High Field (4 Tesla)
Miki, A., Liu, G. T., Raz, J. A., Englander, S. A., Bonhomme, G. R., Aleman, D. O., Modestino, E. J., Liu, C. J., & Haselgrove, J. C. (2001) · Journal of Neuro-Ophthalmology · doi:10.1097/00041327-200103000-00002 · Cited by 20
“5 T scanners) (12), and the contribution of the capillaries to the signal change relative to that of large vessels can be increased by the use of magnetic resonance (MR) scanners with higher field strengths (13,14).”
BackgroundOxygen-induced MR signal changes in murine tumors
Peller, M., Weissfloch, L., Stehling, M. K., Weber, J., Bruening, R. D., Senekowitsch–Schmidtke, R., Molls, M., & Reiser, M. F. (1998) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)00076-9 · Cited by 20
Wu, L., Liu, L., Rao, S., Wu, P., & Zhou, J. (2022) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-022-05481-9 · Cited by 20
“Maps of the T2* was calculated using R2*(R2* = 1/T2*) [26, 27].”
MethodPerformance of receive head arrays versus ultimate intrinsic SNR at 7 T and 10.5 T
Zhang, B., Radder, J., Giannakopoulos, I. I., Grant, A., Lagore, R., Waks, M., Tavaf, N., de Moortele, P. V., Adriany, G., Sadeghi‐Tarakameh, A., et al. (2024) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30108 · Cited by 19
Keur‐Huizinga, L., Kramer, S. E., de Geus, E. J. C., & Zekveld, A. A. (2024) · Ear and Hearing · doi:10.1097/aud.0000000000001508 · Cited by 21
Kuroiwa, D., Obata, T., Kawaguchi, H., Autio, J. A., Hirano, M., Aoki, I., Kanno, I., & Kershaw, J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.04.050 · Cited by 19
“MRI with blood oxygen level dependent (BOLD) contrast has been widely used as a functional imaging tool, and it is now one of the most important methods in the neuroscience field (Ogawa et al., 1992, 1993).”
Amino acid challenge and depletion techniques in human functional neuroimaging studies: an overview
Biskup, C. S., Gaber, T. J., Helmbold, K., Bubenzer‐Busch, S., & Zepf, F. D. (2015) · Amino Acids · doi:10.1007/s00726-015-1919-z · Cited by 19
“By measuring the blood oxygen level-dependent (BOLD) contrast, changes in regional blood flow can be measured, which are usually interpreted to reflect changes in the activation of the particular brain region (Ogawa et al. 1993).”
BackgroundWardlaw, G. M., Wong, R. K. W., & Noseworthy, M. D. (2008) · Physica Medica · doi:10.1016/j.ejmp.2008.01.006 · Cited by 19
Cho, S., Hachmann, J. T., Balzekas, I., In, M., Andres‐Beck, L. G., Lee, K. H., Min, H.-K. P., & Jo, H. J. (2019) · Brain and Behavior · doi:10.1002/brb3.1431 · Cited by 19
Wang, F., Dong, Z., Wald, L. L., Polimeni, J. R., & Setsompop, K. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118641 · Cited by 19
“Among those, spin-echo (SE) or T2 BOLD fMRI has shown great potential (Bandettini and Wong, 1995; Boxerman et al., 1995; Ogawa et al., 1993) and has been demonstrated to provide superior specificity compared to GE BOLD (Huber et al.”
Cheng, Y., van Zijl, P. C. M., & Hua, J. (2014) · NMR in Biomedicine · doi:10.1002/nbm.3250 · Cited by 19
Distinct spatial patterns of brain activity associated with memory storage and search
Zarahn, E., Rakitin, B. C., Abela, D., Flynn, J., & Stern, Y. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.07.020 · Cited by 19
“During the performance of each block of the DIR task, 207 BOLD images (Kwong et al., 1992; Ogawa et al., 1993), were acquired with an Intera 1.5 T Phillips MR scanner equipped with a standard quadrature head coil, using a gradient echo echo-planar (GE-EPI) pulse sequence [TE/TR = 50 ms/3000 ms;…”
MethodInfluentialRoussel, T., Frydman, L., Bihan, D. L., & Ciobanu, L. (2019) · Scientific Reports · doi:10.1038/s41598-019-40986-9 · Cited by 19
Understanding the Morphological Mismatch between Magnetic Susceptibility Source and T2* Image
Chen, Z., & Calhoun, V. D. (2013) · Magnetic Resonance Insights · doi:10.4137/mri.s11920 · Cited by 19
“It is understood that as the phase angle of spin precession in Equations (2) and (3) increases, the small angle condition in Equation (8) is no longer held (for example, γ TE b ≈ π resulting from long echo time TE and high field value b).”
BackgroundMethodInfluentialLin, W., Paczynski, R. P., Çelik, A., Hsu, C. Y., & Powers, W. J. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199809000-00011 · Cited by 19
Romeo, M., Vizioli, L., Breukink, M. B., Aganloo, K., Lao, J., Cotrufo, S., Caldara, R., & Morley, S. E. (2013) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0b013e3182818b68 · Cited by 19
Origins of the BOLD changes due to synaptic activity at astrocytes abutting arteriolar smooth muscle
Bennett, M. R., Farnell, L., & Gibson, W. G. (2008) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2008.01.022 · Cited by 19
New Technologies for the Surgical Curriculum
Aggarwal, R. K., Leong, J., Leff, D. R., Warren, O. J., Yang, G., & Darzi, A. W. (2007) · World Journal of Surgery · doi:10.1007/s00268-007-9338-2 · Cited by 19
“Noninvasive brain imaging techniques can be broadly classified into direct—such as electroencephalography (EEG) and magnetoencephalography (MEG), which measure brain function directly based on neuronal discharge— and indirect—such as functional magnetic resonance imaging (fMRI) and functional near-infrared spectroscop…”
BackgroundFunctional BOLD MRI: comparison of different field strengths in a motor task
Meindl, T., Born, C., Britsch, S., Reiser, M., & Schoenberg, S. (2008) · European Radiology · doi:10.1007/s00330-008-0869-1 · Cited by 19
“Biophysical studies showed that the BOLD effect for large vessels is proportional to B0 and for small vessels and capillaries proportional to B0 [5–7].”
BackgroundOrigin of the signal undershoot in BOLD studies of the visual cortex
Jones, R. A. (1999) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199908)12:5<299::aid-nbm566>3.0.co;2-h · Cited by 19
Magnetic resonance perfusion imaging
Prasad, P. V., Edelman, R. R., & Buxton, R. B. (1995) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.1850060214 · Cited by 19
Miki, A., Raz, J., Englander, S. A., Butler, N. S., van Erp, T. G., Haselgrove, J. C., & Liu, G. T. (2001) · Japanese Journal of Ophthalmology · doi:10.1016/s0021-5155(00)00304-x · Cited by 19
Zhang, K., Chen, L., Li, Y., Paez, A. G., Miao, X., Cao, D., Gu, C., Pekar, J. J., van Zijl, P. C. M., Hua, J., et al. (2023) · Journal of Neuroscience · doi:10.1523/jneurosci.1488-22.2023 · Cited by 20
Park, S., Kim, T. I., Wang, P., & Kim, S. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.010 · Cited by 18
“Blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) technique (Bandettini et al., 1992; Kwong et al., 1992; Ogawa et al., 1993) has made a wide impact on neuroscience, physiology, and psychology.”
Self-citationApplications of Resting State Functional MR Imaging to Neuropsychiatric Diseases
Pearlson, G. D. (2017) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2017.06.005 · Cited by 18
Li‐Ou, Z., Hong‐Zan, S., Xiao‐Xi, B., Chen, Z., Lu, Z., Jun, X., & Qi‐Yong, G. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26557 · Cited by 18
“Furthermore, the hypoxic condition of tumors can be measured by the gradient-recalled echo (GRE) multiecho R2* sequence, in which the R2* value is linearly correlated with the concentration of deoxygenated hemoglobin in the tissue.(5,6) It should be noted that iron deposition and hemoglobin decomposition affect the me…”
BackgroundDynamics of the cerebral blood flow response to brief neural activity in human visual cortex
Kim, J. H., Taylor, A. J., Wang, D. J. J., Zou, X., & Ress, D. B. (2019) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x19869034 · Cited by 18
Venous cerebral blood volume mapping in the whole brain using venous‐spin‐labeled 3D turbo spin echo
Lee, H., & Wehrli, F. W. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28262 · Cited by 18
“With increasing T1,v and decreasing T1,t, assumption (1) is no longer valid, therefore causing increasing underestimation of CBVv by up to 45% (Figure 6A,B).”
BackgroundMethodInfluentialAn Overview of ICA/BSS-Based Application to Alzheimer’s Brain Signal Processing
Yang, W., Pilozzi, A. R., & Huang, X. (2021) · Biomedicines · doi:10.3390/biomedicines9040386 · Cited by 18
“The detection of changes in neural activity using BOLD-fMRI [53,59] generally involves the identification of voxel signals that correlate with an imposed experimental paradigm [60].”
MethodCiulla, C., Veljanovski, D., Shikoska, U. R., & Risteski, F. A. (2015) · Journal of Advanced Research · doi:10.1016/j.jare.2015.01.001 · Cited by 18
Colliez, F., Fruytier, A., Magat, J., Neveu, M.-A. C., Cani, P. D., Gallez, B., & Jordan, B. F. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25642 · Cited by 18
“Although T1 measurements reflect oxygenation in tissues, oxygenation in the vascular compartment can also be assessed using blood oxygen level–dependent MRI or functional MRI (32).”
BackgroundTuntiyatorn, L., Wuttiplakorn, L., & Laohawiriyakamol, K. (2011) · PubMed · Cited by 18
Chen, Z., & Calhoun, V. D. (2016) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2016.01.007 · Cited by 18
Interactions between head motion and coil sensitivity in accelerated fMRI
Faraji-Dana, Z., Tam, F., Chen, J. J., & Graham, S. J. (2016) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2016.06.005 · Cited by 18
Entropic regression with neurologically motivated applications
Fish, J., DeWitt, A., AlMomani, A. A. R., Laurienti, P. J., & Bollt, E. M. (2021) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/5.0039333 · Cited by 18
Schumacher, J. F., Thompson, S. K., & Olman, C. A. (2011) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2011.00019 · Cited by 18
“…common gradient echo (GE) BOLD techniques that use T 2 *-weighted images to maximize sen- sitivity to magnetic field perturbations in and near veins (Ogawa et al., 1993; Bandettini et al., 1994), spin echo (SE) BOLD techniques use T 2 -weighted images to bias BOLD sensitivity toward small venules…”
Functional Magnetic Resonance Imaging (fMRI) and Expert Testimony
Kulich, R. J., Maciewicz, R. J., & Scrivani, S. J. (2009) · Pain Medicine · doi:10.1111/j.1526-4637.2009.00567.x · Cited by 18
k-Space spatial low-pass filters can increase signal loss artifacts in echo-planar imaging
Caparelli, E. C., & Tomasi, D. G. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.11.003 · Cited by 18
“Most fMRI studies use gradient-recalled echo EPI (GRE-EPI) pulse sequences , because of its high sensitivity to BOLD-related susceptibility changes (Ogawa et al., 1993).”
BackgroundMandeville, J. B., & Rosen, B. R. (2002) · Elsevier eBooks · doi:10.1016/b978-012693019-1/50015-0 · Cited by 18
Measuring arterial and tissue responses to functional challenges using arterial spin labeling
Ho, Y.-C. L., Petersen, E. T., & Golay, X. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.07.040 · Cited by 18
Truong, T., Chakeres, D. W., Scharre, D. W., Beversdorf, D. Q., & Schmalbrock, P. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20916 · Cited by 18
“They are needed to optimize acquisition parameters and enhance our understanding of relaxation mechanisms in many applications, such as blood oxygenation level-dependent (BOLD) functional MRI (fMRI) (1), vessel size imaging (2,3), assessment of tissue iron content (4,5), bone densitometry (6,7), and dynamic susceptibi…”
Kershaw, J., Tomiyasu, M., Kashikura, K., Hirano, Y., Nonaka, H., Hirano, M., Ikehira, H., Kanno, I., & Obata, T. (2009) · NMR in Biomedicine · doi:10.1002/nbm.1391 · Cited by 14
Identifying global anatomical differences: Deformation-based morphometry
(1998) · doi:10.1002/(sici)1097-0193(1998)6:5/6
Metadata
- Authors
- Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K.
- Affiliations
- AT&T (United States) (US)
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1993-03
- Volume
- 64
- Issue
- 3
- Pages
- 803-812
- ISSN
- 0006-3495 (ISSN-L)
- PMC
- PMC1262394
- OpenAlex
- W2088774650
- Semantic Scholar
- 8854e4f488c6efa175ad199a5b1e23b852de8b36
- Cited by
- 1,772
- References
- 19
- Citations by year
- 2026: 18 · 2025: 41 · 2024: 42 · 2023: 31 · 2022: 34 · 2021: 47 · 2020: 37 · 2019: 41 · 2018: 43 · 2017: 51 · 2016: 55 · 2015: 65 · 2014: 67 · 2013: 68 · 2012: 78
- FWCI
- 33.05
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/open-access/userlicense/1.0/ (vor, 7442 d)
- Locations
- Biophysical Journal (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
- Keywords
- blood oxygenation level-dependent contrast, BOLD signal, functional brain mapping, deoxyhemoglobin, primary visual cortex, photic stimulation, signal oscillations, R2* relaxation rate, Monte Carlo simulation, biophysical model
- MeSH terms
- Biophysics, Body Water, Brain, Cerebrovascular Circulation, Humans, Magnetic Resonance Imaging, Models, Neurological, Monte Carlo Method, Oxygen, Protons, Visual Cortex, Biophysical Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.