The Utah Intracortical Electrode Array: A recording structure for potential brain-computer interfaces
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
We investigated the potential of the Utah Intracortical Electrode Array (UIEA) to provide signals for a brain-computer interface (BCI). The UIEA records from small populations of neurons which have an average signal-to-noise ratio (SNR) of 6:1. We provide specific examples that show the activities of these populations of neurons contain sufficient information to perform control tasks. Results from a simple stimulus detection task using these signals as inputs confirm that the number of neurons present in a recording is significant in determining task performance. Increasing the number of units in a recording decreases the sensitivity of the response to the stimulus; decreasing the number of units in the recording, however, increases the variability of the response to the stimulus. We conclude that recordings from small populations of neurons, not single units, provide a reliable source of sufficiently stimulus selective signals which should be suitable for a BCI. In addition, the potential for simultaneous and proportional control of a large number of external devices may be realized through the ability of an array of microelectrodes such as the UIEA to record both spatial and temporal patterns of neuronal activation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Traditional commercial implantable neural interfaces (e.g., Utah electrodes[306] and Michigan electrodes[307]) typically contain noble metals[308] (high conductivity and chemical stability), and silicon-based materials[309] (ideally suited to existing microfabrication techniques) as electrodes.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [306]
Citations
Cites
Receptive fields, binocular interaction and functional architecture in the cat’s visual cortex
Hubel, D. H., & Wiesel, T. N. (1962) · The Journal of Physiology · doi:10.1113/jphysiol.1962.sp006837 · Cited by 13,680
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
Neuronal Population Coding of Movement Direction
Georgopoulos, A. P., Schwartz, A. B., & Kettner, R. E. (1986) · Science · doi:10.1126/science.3749885 · Cited by 3,161
The two-dimensional spatial structure of simple receptive fields in cat striate cortex
Jones, J. P., & Palmer, L. A. (1987) · Journal of Neurophysiology · doi:10.1152/jn.1987.58.6.1187 · Cited by 668
Size, laminar and columnar distribution of efferent cells in the sensory‐motor cortex of monkeys
Jones, E. G., & Wise, S. P. (1977) · Journal of Comparative Neurology · doi:10.1002/cne.901750403 · Cited by 508
Electrophysiology of a Dendritic Neuron Model
Rall, W. (1962) · Biophysical Journal · doi:10.1016/s0006-3495(62)86953-7 · Cited by 492
The Motor Cortex and the Coding of Force
Georgopoulos, A. P., Ashe, J., Smyrnis, N., & Taira, M. (1992) · Science · doi:10.1126/science.256.5064.1692 · Cited by 460
Multichannel EEG-based brain-computer communication
Wolpaw, J. R., & McFarland, D. J. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90135-x · Cited by 449
A three-dimensional microelectrode array for chronic neural recording
Hoogerwerf, A. C., & Wise, K. D. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.335862 · Cited by 371
Predicting Measures of Motor Performance from Multiple Cortical Spike Trains
Humphrey, D. R., Schmidt, E. M., & Thompson, W. D. (1970) · Science · doi:10.1126/science.170.3959.758 · Cited by 370
Research works printed but not linked: 2
- Heetderks, 1995, Command-control signals from the neural activity of motor cortical cells: joy-stick control, Vol. 15, 664
- Humphrey, 1995, Intracortical recording of brain activity for control of limb prostheses, Vol. 15, 650
Cited by
Items 401–500 of 684
Localized stimulation and recording in the spinal cord with microelectrode arrays
Arle, J. E., Shils, J. L., & Malik, W. Q. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346312 · Cited by 7
BRAIN-COMPUTER INTERFACE FOR THE AUGMENTATION OF BRAIN FUNCTIONS
Lebedev, M. (2016) · Science and Innovations in Medicine · doi:10.35693/2500-1388-2016-0-3-11-27 · Cited by 7
Recent advances in SiC biomedical devices
Saddow, S. E. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-90609-8.00006-5 · Cited by 11
Marple: Scalable Spike Sorting for Untethered Brain-Machine Interfacing
Sha, E., Liu, A. W., Ibrahim, K., Mahmoud, M., Giannoula, C., Abdelhadi, A., & Moshovos, A. (2024) · International Conference on Architectural Support for Programming Languages and Operating Systems (ASPLOS) · doi:10.1145/3620665.3640357 · Cited by 9
“Real-time interaction via neuronal communication enables life-changing advances, e.g. motor control for paralysis patients [22, 42], epilepsy detection and mitigation [14, 44, 85], treatment of Parkinson’s disease [29, 33], and cognitive control [77].”
BackgroundMethodGage, G. J., Stoetzner, C. R., Richner, T. J., Brodnick, S. K., Williams, J. C., & Kipke, D. R. (2012) · Journal of Visualized Experiments · doi:10.3791/3565-v · Cited by 7
Varkevisser, F., Costa, T. L., & Serdijn, W. A. (2022) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ac8c47 · Cited by 7
Strategies for High-Performance Resource-Efficient Compression of Neural Spike Recordings
Thorbergsson, P. T., Garwicz, M., Schouenborg, J., & Johansson, A. J. (2014) · PLoS ONE · doi:10.1371/journal.pone.0093779 · Cited by 7
“Thus, for a state-ofthe-art electrode array with 100 channels [7], the total data rate becomes 25 Mbps, which typically requires a physical (wired) link between the implanted and external parts of the BMI.”
BackgroundNon-Manual Control Devices: Direct Brain-Computer Interaction
Scherer, R., & Rao, R. P. N. (2011) · IGI Global eBooks · doi:10.4018/978-1-60566-206-0.ch015 · Cited by 8
Bioelectric Medicine and Devices for the Treatment of Spinal Cord Injury
Torregrosa, T., & Koppes, R. A. (2016) · Cells Tissues Organs · doi:10.1159/000446698 · Cited by 8
“BrainGate utilizes a silicon electrode array (96 channels) [Maynard et al., 1997] that penetrates ∼ 1.5 mm into the motor cortex to record the action potentials of approximately 50 individual neurons.”
MethodInfluentialInvasive Brain–Computer Interfaces for Functional Restoration
Ajiboye, A. B., & Kirsch, R. F. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-805353-9.00027-9 · Cited by 9
Microelectrode coatings for neural stimulation and recording
Cogan, S. F. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280988 · Cited by 7
Limits of brain–computer interface
Bakay, R. A. E. (2006) · Neurosurgical FOCUS · doi:10.3171/foc.2006.20.5.7 · Cited by 7
Large Margin Multi-channel Analog-to-Digital Conversion with Applications to Neural Prosthesis
Gore, A., & Chakrabartty, S. (2007) · The MIT Press eBooks · doi:10.7551/mitpress/7503.003.0067 · Cited by 7
“Experimental results with real recorded multi-channel neural data demonstrate the effectiveness of the proposed algorithm in alleviating cross-channel redundancy acrosselectrodes and performing data-compression directly at the A/D converter.”
Micromachined LCP Connectors for Packaging MEMS Devices in Biological Environments
Dean, R. N., Weller, J., Bozack, M., Farrell, B., Jauniskis, L., Ting, J., Edell, D. J., & Hetke, J. F. (2007) · Journal of Microelectronics and Electronic Packaging · doi:10.4071/1551-4897-4.1.17 · Cited by 10
Fully unsupervised online spike sorting based on an artificial spiking neural networkPreprint
Bernert, M., & Yvert, B. (2017) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/236224 · Cited by 8
“…technologies have made possible to build large-scale microelectrode arrays offering hundreds or thousands of recording sites in single probes 12–18 , and increasing efforts are currently put in the development of novel devices to make possible the recording of up to a million of cells…”
BackgroundA Discriminative Approach to Bayesian Filtering with Applications to Human Neural Decoding
Burkhart, M. C. (2019) · HAL · Cited by 10
Delbeke, J., & Veraart, C. (2006) · Wiley eBooks · doi:10.1002/0471732877.emd325 · Cited by 7
Real-Time spike sorting using an optimized STDP Spiking Neural Network on FPGA
Cheslet, J., Bernert, M., Beaubois, R., Yvert, B., & Levi, T. (2024) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn60899.2024.10650675 · Cited by 6
“Neural-recording devices, particularly Multi-Electrode Ar-rays (MEAs), have evolved to capture an increasing number of channels with higher probe density either in-vitro [1], [2] or in-vivo [3], [4].”
BackgroundOptimal placement of high-channel visual prostheses in human retinotopic visual cortex
van Hoof, R., Lozano, A., Wang, F., Klink, P. C., Roelfsema, P. R., & Goebel, R. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adaeef · Cited by 6
“…in neurotechnology are revolutionizing the restoration of lost sensory and motor functions, such as vision, hearing, and movement, through direct brain recording and stimulation (Maynard et al 1997, Musk 2019, Sahasrabuddhe et al 2020, Hettick et al 2022, Jung et al 2024, Schalk et al 2024).”
Towards real time efficient and robust ECoG decoding for mobile brain–computer interface
Lin, Z., Jiang, X., Dai, C., & Jia, F. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ade917 · Cited by 9
“Various invasive BCI technologies have been explored to achieve high-fidelity neural decoding, including microelectrode arrays such as the Utah array [7], stereoelectroencephalography [8] and electrocorticography (ECoG) [1, 9–11].”
Structural and Functional Designs of Advanced Neural Electrodes
Cheng, J., Xiao, M., & Li, Z. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5c15407 · Cited by 6
Individualized brain-computer interface for people with disabilities: a review
Saha, S., Karlsson, P., Anderson, C. J., Kavehei, O., & McEwan, A. L. (2026) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2026.1738876 · Cited by 6
A hierarchical artificial retina architecture
Parker, A. C., & Azar, A. N. (2009) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.821578 · Cited by 6
“The Utah Electrode Array is one of the main intracortical prosthesis projects [9].”
BackgroundRecent advancements in Micro-engineered devices for surface and deep brain animal studies: A review
Bhaskara, S., Sakorikar, T., Chatterjee, S., Kv, S. G., & Pandya, H. J. (2022) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2022.100483 · Cited by 9
Darlot, F., Villard, P., Salam, L. A., Rousseau, L., & Piret, G. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1408088 · Cited by 8
Ultracompact Multielectrode Array for Neurological Monitoring
Cheng, M., Damalerio, R., Chen, W., Rajkumar, R., & Dawe, G. S. (2019) · Sensors · doi:10.3390/s19102286 · Cited by 6
“Floating microelectrode arrays (FMAs) [9] and Utah electrode arrays (UEAs) [10,12] are commercially prominent in neuroscientific research.”
BackgroundStream-based Hebbian eigenfilter for real-time neuronal spike discrimination
Yu, B., Mak, T. S. T., Li, X., Smith, L. S., Sun, Y., & Poon, C. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-18 · Cited by 6
“Background Recently, multi-electrode arrays (MEAs) have become increasingly popular for neurophysiological experiments in vivo [1-4] or in vitro [5-8].”
BackgroundDirect Neural Control of Anatomically Correct Robotic Hands
Widge, A. S., Moritz, C. T., & Matsuoka, Y. (2010) · Human-computer interaction series · doi:10.1007/978-1-84996-272-8_7 · Cited by 9
“Stable, long-term recording of single neuron activity has become easier with the advent of high-density (up to 100 recording sites) microelectrode arrays created with silicon microfabrication technology ( Maynard et al. 1997; Vetter et al. 2004).”
BackgroundSolvent-Free Strategy To Encapsulate Degradable, Implantable Metals in Silk Fibroin
Hawker, M. J., Guo, C., Omenetto, F. G., & Kaplan, D. L. (2018) · ACS Applied Bio Materials · doi:10.1021/acsabm.8b00498 · Cited by 7
Chronic Neural Recording with a 64-Channel Cortical Microsystem
Sodagar, A. M., Perlin, G. E., Yao, Y., Najafi, K., & Wise, K. D. (2007) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2007.369694 · Cited by 6
“High-density arrays of silicon-based microelectrodes [1,2] for recording single-unit activity in the central nervous system are widely viewed as a promising path to revolutionary progress in such studies [3,4].”
BackgroundSilk-enabled conformal intraventricular interfaces for minimally invasive neural recordings
Liang, J., Wang, X., Chen, Z., Wei, X., Sun, L., Liu, K., Shi, Z., Tao, T. H., & Zhou, Z. (2025) · Nature Communications · doi:10.1038/s41467-025-64397-9 · Cited by 5
Gao, Y., Lu, Z., Wang, X., Jin, Z., Esteban‐Linares, A., Guo, J., Xu, H., Scholten, K., Song, D., & Meng, E. F. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae385c · Cited by 5
Conformal bumped electrode web for chronic ECoG recordings in swine
Wang, M., Jiang, H., Ni, C., Zhou, X., Xu, Y., Shang, S., You, X., Wang, W., Zhou, C., Zhang, W., et al. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01180-w · Cited by 6
“Normann et al. at the University of Utah proposed the Utah electrode Array in 1997, a rigid ECoG electrode that allows the electrode to penetrate neural tissue, thus recording broader and deeper neuronal activity 1,2 .”
Depth‐Customizable 3D Electrode Array for Recording Functional Connectivity in the Brain
Kim, M., Park, S., Lee, H., Lee, J., Chou, N., & Shin, H. (2025) · Advanced Electronic Materials · doi:10.1002/aelm.202500121 · Cited by 5
von Papen, M., Dafsari, H. S., Florin, E., Gerick, F., Timmermann, L., & Saur, J. (2017) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2017.08.021 · Cited by 6
Strategies to Improve Neural Electrode Performance
Guido, K., Clavijo, A. S., Zhu, K., Ding, X., & Ma, K. (2020) · Springer eBooks · doi:10.1007/978-3-030-41854-0_7 · Cited by 5
Information Transmission through Biotic–Abiotic Interfaces to Restore or Enhance Human Function
Kelly, A. R., & Glover, D. J. (2024) · ACS Applied Bio Materials · doi:10.1021/acsabm.4c00435 · Cited by 5
Wang, Y., Wang, Z., & Liu, S. (2024) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas61083.2024.10798182 · Cited by 5
“Neural signals from the motor cortex and premotor cortex of patients can be recorded using multi-electrode recording arrays like the Utah micro-electrode array [1].”
Brain-Machine Interfaces: Restoring and Establishing Communication Channels
Rodenkirch, C., Schriver, B. J., & Wang, Q. (2016) · Springer eBooks · doi:10.1007/978-3-319-31433-4_8 · Cited by 5
“Also around this time, an MEA , commonly referred to as the Utah array , was developed and deemed a large step toward an MEA suitable for human implantation (Maynard et al. 1997 ).”
BackgroundA memristor-CMOS hybrid architecture concept for on-line template matching
Serb, A., Papavassiliou, C., & Prodromakis, T. (2017) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2017.8050964 · Cited by 5
Implantable computer-controlled adaptive multielectrode positioning system
Ferrea, E., Suriya-Arunroj, L., Hoehl, D., Thomas, U., & Gail, A. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00504.2017 · Cited by 5
“Second, neuronal recordings can be performed with microelectrode arrays that are chronically implanted on the cortex under the dura during a surgery (Maynard et al. 1997; Musallam et al. 2007).”
BackgroundMégevand, P., Woodtli, A., Yulzari, A., Cosgrove, G. R., Momjian, S., Stimec, B. V., Corniola, M. V., & Fasel, J. H. D. (2017) · Journal of Visualized Experiments · doi:10.3791/56584 · Cited by 6
Omidvar, A., & Shaterian, M. (2019) · Microelectronics Journal · doi:10.1016/j.mejo.2019.104654 · Cited by 6
Cross-Channel Impedance Measurement for Monitoring Implanted Electrodes
Earley, E. J., Mastinu, E., & Ortiz-Catalan, M. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871954 · Cited by 5
“Implantable sensors, such as the epimysial, intramuscular, and cuff electrodes often used in prosthetic limb control [1], [2] and the microelectrode arrays used with neural tissues [3]–[5], are typically made of biologically inert materials such as platinum, titanium, or tungsten to maximize biocompatibility and reduc…”
BackgroundUsing human computer interaction concepts to design interfaces for the brain injured
Gnanayutham, P., & George, J. (2006) · Cited by 6
Implementing a neuromorphic cross-correlation engine with silicon neurons
Folowosele, F. O., Tenore, F. V., Russell, A., Orchard, G., Vismer, M. P., Tapson, J. C., & Etienne‐Cummings, R. (2008) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2008.4541879 · Cited by 5
“In particular, microelectrode arrays such as the Utah Intracortical Electrode Array (UIEA), Michigan electrode array and the University of Florida flexible substrate microelectrode array, which can be implanted in the cortex, have been developed [1]–[3].”
MethodMobility enhancement using simulated artificial human vision
Dowling, J. (2007) · Cited by 7
Benchtop Carbon Fiber Microelectrode Array Fabrication ToolkitPreprint
Richie, J., Patel, P. R., Welle, E. J., Dong, T., Chen, L., Shih, A. J., & Chestek, C. A. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.03.22.436422 · Cited by 5
“Traditionally, commercial probes are silicon-based due to their ability to be fabricated in large batches with a high recording site density [8], [9] and relatively reliable functional stability [10]–[13].”
BackgroundAnaesthesia selectively decouples signal propagation from responsivity in the fronto-parietal loopPreprint
Dwarakanath, A., Khalili‐Ardali, M., Gay, M., Raghuram, H. V., Roustan, M., Jarraya, B., & Panagiotaropoulos, T. I. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.04.15.648923 · Cited by 5
Ionic Circuits for Transduction of Electronic Signals into Biological Stimuli
Tybrandt, K. (2012) · DiVA (Linkoping University) · Cited by 5
Introduction to Neurotechnology: History and Interdisciplinary Innovations
Chaudhary, U. (2025) · Springer eBooks · doi:10.1007/978-3-031-76081-5_1 · Cited by 4
Won, S., Binder, S., Boyadzhiev, A. M., Zhou, Q., Vafaei, A., Botero, J., Lim, T., Angelucci, A., Blair, S., Fan, Y., et al. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6c07028 · Cited by 4
Chen, Q., Huang, N., Tong, C., Liu, P., Que, S., Xue, H., Xiao, X., & Song, E. (2026) · npj Biosensing · doi:10.1038/s44328-026-00109-7 · Cited by 4
Mingliang, 徐. X., Fangyuan, 李. L., Yueqi, 刘. L., Jinhui, 张. Z., Yazhou, 师. S., & Fei, 何. H. (2023) · Chinese Journal of Lasers · doi:10.3788/cjl221482 · Cited by 4
Multiplexed neurochemical sensing with sub-nM sensitivity across 2.25 mm2 area
Hemed, N. M., Hwang, F.-J., Zhao, E. T., Ding, J., & Melosh, N. A. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116474 · Cited by 4
Ajiboye, A. B., Hochberg, L. R., & Kirsch, R. F. (2020) · Springer briefs in electrical and computer engineering · doi:10.1007/978-3-030-49583-1_4 · Cited by 4
Badi, M., Borgognon, S., O’Doherty, J. E., & Shokur, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00008-3 · Cited by 5
Developing clinical grade flexible implantable electronics
Liu, Y., Balsamo, D., & Degenaar, P. A. (2023) · Flexible and Printed Electronics · doi:10.1088/2058-8585/aca779 · Cited by 5
Lee, S., Deshpande, S. S., Merricks, E. M., Schlafly, E. D., Goodman, R., McKhann, G. M., Eskandar, E. N., Madsen, J. R., Cash, S. S., van Putten, M. J. A. M., et al. (2023) · Communications Biology · doi:10.1038/s42003-023-04696-3 · Cited by 4
Comparison metrics and power trade-offs for BCI motor decoding circuit design
Saad, J., Evans, A., Jaoui, I., Roux-Sibillon, V., Hardy, E., & Anghel, L. (2025) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2025.1547074 · Cited by 5
Experimental enhancement of neurphysiological function
Deca, D., & Koene, R. A. (2014) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2014.00189 · Cited by 4
“The FDA has approved clinical trials for cortical motor control of prosthetic arms using Utah arrays (Maynard et al., 1997).”
MethodNonlinear physically-based models for decoding motor-cortical population activity
Shakhnarovich, G., Kim, S.-P., & Black, M. J. (2007) · The MIT Press eBooks · doi:10.7551/mitpress/7503.003.0162 · Cited by 4
“The neural signal was obtained with a Cyberkinetics microelectrode array [9] (96 electrodes) implanted in the arm/hand area of MI cortex.”
MethodElectrical interfaces for recording, stimulation, and sensing
Hess‐Dunning, A., & Zorman, C. A. (2015) · Elsevier eBooks · doi:10.1016/b978-0-323-26208-8.00002-9 · Cited by 4
Brain Machine-Interfaces for Sensory Systems
Fujikado, T. (2016) · Springer eBooks · doi:10.1007/978-4-431-54598-9_10 · Cited by 5
Probabilistically Modeling and Decoding Neural Population Activity in Motor Cortex
Black, M. J., & Donoghue, J. P. (2007) · The MIT Press eBooks · doi:10.7551/mitpress/7493.003.0013 · Cited by 4
“Figure 2a which consists of a 10×10 grid of electrodes [ 15 ].”
BackgroundLozano, A., Suárez, J. S., Soto‐Sánchez, C., Garrigós, J., Martínez, J. J., Vicente, J. M. F., & Fernández-Jover, E. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-19591-5_12 · Cited by 4
Newcastle Visual Prosthesis Implantable Control Unit
Liu, Y., Fattah, N. A., & Degenaar, P. A. (2020) · IEEE International Conference on Electronics, Circuits and Systems (ICECS) · doi:10.1109/icecs49266.2020.9294853 · Cited by 4
“The technique requires the use of “optrodes” [9] to deliver the light into the target brain tissue.”
MethodA Survey on EEG-fNIRS based Non-invasive hBCIs
Sial, M. B., Wang, S., Wang, X., Wyrwa, J., & Ali, S. (2021) · doi:10.1109/icai52203.2021.9445246 · Cited by 5
“This category of BCI deals with devices (electrodes) which are surgically inserted directly into or on the surface of the brain’s cortex like brain implants such as the Utah Array [3] or Electrocorticogram (ECoG) [4].”
BackgroundMiller, B. T., & Hillman, T. A. (2006) · The Laryngoscope · doi:10.1097/01.mlg.0000221966.27228.a8 · Cited by 4
FTSPlot: Fast Time Series Visualization for Large Datasets
Riss, M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0094694 · Cited by 4
“For in vivo experiments, protruding electrode arrays are available to record extra-cellular potentials from cortical areas for over two years [1–4], microwire bundles can be used to record extra-cellular potentials from deeper areas within the brain for more than one year [5–8], and cuff/cone electrodes provide record…”
BackgroundSystem and Circuit Design for Biologically-Inspired Intelligent Learning
Temel, T. (2011) · IGI Global eBooks · doi:10.4018/978-1-60960-018-1 · Cited by 4
Implanted intracortical electrodes as chronic neural interfaces to the central nervous systemPreprint
Henderson, P. (2015) · doi:10.7287/peerj.preprints.1255v1 · Cited by 5
“Utah microarrays retain a relatively high signal-to-noise ratio of 6:1 on average [23], making them well-suited for precision tasks.”
BackgroundInterfacing Microelectronics and the Human Visual System
Agrawal, R. N., Humayun, M. S., Weiland, J. D., Lazzi, G., & Gosalia, K. C. (2005) · doi:10.1201/9781420037715-22 · Cited by 4
Evolutionarily conserved neural dynamics across mice, monkeys, and humansPreprint
Codol, O., Asclipe, M., Sobinov, A. R., Chen, Z., Park, J., Hatsopoulos, N. G., Dudman, J. T., Gallego, J. Á., Lajoie, G., & Perich, M. G. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.03.06.709637 · Cited by 4
“As the monkeys performed this task, neural spiking activity was recorded using chronically implanted Utah microelectrode arrays targeting the arm region of the motor cortex 31 .”
Testing circuit-level theories of consciousness in humans
Dykstra, A. R., Zhu, Y., Fernandez Pujol, C., Zhou, D. W., Jones, S. R., Marvan, T., & Bonaiuto, J. J. (2026) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2025.08.012 · Cited by 3
“In a subset of patients undergoing treatment for certain neurological conditions (e.g., epilepsy, tumor), it is possible to acquire recordings of meso-and even microscale activity via laminar probes [102 – 104], single-unit arrays [105], or high-density surface [106] and depth [107] electrodes.”
Invasive Brain Signal Acquisition Techniques: SUA, MUA, LFP, ECoG in Neuroimaging and Recording
Chaudhary, U. (2025) · Springer eBooks · doi:10.1007/978-3-031-76081-5_3 · Cited by 3
One-Step Laser-Induced Dissolvable PVA Mask for 3D Soft Carbon Electrode Array
Wang, X., Xue, K., Bai, R., Huang, Y., Zhang, Z., You, X., Wang, M., Chang, H., & Ji, B. (2025) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems61431.2025.10917919 · Cited by 3
“While 3D electrodes such as Utah arrays improve tissue integration, they are rigid and may cause obvious tissue damage [6].”
Material damage to multielectrode arrays after electrolytic lesioning is insignificant
Tor, A., Clarke, S. E., Bray, I. E., & Nuyujukian, P. (2026) · eLife · doi:10.1101/2025.03.26.645429 · Cited by 3
“Specifically, the 96-channel Utah array (Blackrock Neurotech, Salt Lake City, UT) has been used to make pivotal discoveries in motor systems neuroscience and develop clinically impactful brain-computer interfaces [2, 4–8].”
Innovative ultra-high-density microelectrode arrays based on CMOS and MEMS technology
Liu, B., Ni, C., Tong, B., Yang, D., Wang, X., & Huang, L. (2025) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ae0fa1 · Cited by 3
“Current MEAs are mainly developed based on the early Utah electrodes [25] and Michigan electrodes [26].”
Connecting Minds and Devices: A Fifty-Year Review of Brain-Computer Interfaces
Sun, Y., Chen, X., Wang, Y., Li, Y., Zhang, Y., Wu, Q., Gao, S., & Gao, X. (2025) · Chinese Journal of Electronics · doi:10.23919/cje.2023.00.325 · Cited by 4
Luo, Z., Zeng, T., Zhao, C., Xie, K., Cai, Y., Yin, D., Atrens, A., & Zhao, M. (2025) · Smart Materials in Manufacturing · doi:10.1016/j.smmf.2025.100092 · Cited by 7
A roadmap to navigate the future of neural engineering
Grill, W. M., Chestek, C. A., Wang, Y., Aberra, A. S., Destexhe, A., Chan, R. H. M., Lu, B., Hanein, Y., Robinson, J. T., Whitmire, C., et al. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae78c2 · Cited by 3
“Microelectrode arrays capable of recording and stimulating neural activity with high spatial resolution [109, 110] was one critical breakthrough that continues to enable ground-breaking research in neural prosthetics [101] and neural rehabilitation.”
AECuration: automated event curation for spike sorting
Li, X., Reddy, J. W., Jain, V., Forssell, M., Ahmed, Z., & Chamanzar, M. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adaa1c · Cited by 3
“Since the first microelectrode device was used for extracellular recording [10], the number of simultaneous recording channels has dramatically increased [11, 12].”
Artificial Sensory Feedback to the Brain: Somatosensory Feedback for Neural Devices and BCI
Bjånes, D. A., & Moritz, C. T. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_111-2 · Cited by 4
van de Wauw, C., Riecke, L., Goebel, R., Kaas, A. L., & Sorger, B. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120172 · Cited by 3
“(EEG; Farwell & Donchin, 1988) and intracortical recordings (Kennedy & Bakay, 1998; Maynard et al., 1997) were developed and successfully tested (Birbaumer et al.”
The Future of Neural Interface Technology
Park, M. C., Goldman, M. A., Belknap, T. W., & Friehs, G. M. (2009) · Springer eBooks · doi:10.1007/978-3-540-69960-6_193 · Cited by 7
Identification and quantification of electrical leakage pathways in floating microelectrode arrays
Bredeson, S. D., Troyk, P. R., Suh, S., & Bak, M. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609807 · Cited by 3
Nanotechnologies for the Bioelectronic Interface
Avants, B. W., Park, H., & Robinson, J. T. (2016) · Wiley eBooks · doi:10.1002/9783527801312.ch6 · Cited by 3
Bioinspired Stimulus Encoder for Cortical Visual Neuroprostheses
Sousa, L. A., Tomás, P., Pelayo, F. J., Martínez-Álvarez, A., Morillas, C. A., & Romero, S. F. (2005) · Springer eBooks · doi:10.1007/1-4020-3128-9_22 · Cited by 3
Microelectrode Arrays, Implants, and Organs-on-a-Chip
Pasquarelli, A. (2021) · Learning materials in biosciences · doi:10.1007/978-3-030-76469-2_11 · Cited by 3
Retina-like processing and coding platform for cortical neuro-stimulation
Pelayo, F. J., Martínez-Álvarez, A., Morillas, C. A., Romero, S. F., Sousa, L. A., & Tomás, P. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280132 · Cited by 3
Electrode arrays for large-scale neural interfaces
Guillory, K. S., & Hatt, B. W. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2002.1053167 · Cited by 3
Decoding speech from brain activity using linear methods
Godais, G. L. (2022) · theses.fr (ABES) · doi:10.70675/a715ba1dz66edz4e28za0faz7cd8ac99c928 · Cited by 6
Passive brain–computer interfaces: tracking mental states for neuroadaptive technology
Klug, M., Gherman, D. E., Krol, L. R., & Zander, T. O. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-24824-5.00010-7 · Cited by 3
Integration of learned artificial sensation with vision during freely moving navigation
Senneka, S. J., & Dadarlat, M. C. (2026) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2521769123 · Cited by 2
Fully automated insertion algorithm of flexible electrodes for invasive brain-machine interface
Ye, A., Wang, X., Song, Y., Li, Y., Zhu, Z., & Zhang, D. (2026) · Pattern Recognition Letters · doi:10.1016/j.patrec.2026.04.003 · Cited by 2
Maughan, J., Woods, I., O’Connor, C., Quintana-Sarti, P., Caffrey, E., Munuera, J., Carey, T., Dervan, A. G., Valdés, A. L., Mamad, O., et al. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.202505076 · Cited by 2
“This freestanding, highly flexible microelectrode array (Figure 6D,E) is capable of conforming to complex tissue surfaces including mouse muscle (Figure 6F; Figure S15B) and rat spinal cord (Figure 6G; Figure S15A,C), unlike traditional rigid electrodes [112, 133].”
Full‐Stack Architectures for Intelligent Brain‐Computer Interfaces
Lee, H. K., Kim, H. B., Park, S. U., Joo, J., Min, J., Lee, G., Kang, J. Y., Jeong, H., Yoo, J., & Won, S. M. (2026) · Advanced Science · doi:10.1002/advs.75838 · Cited by 2
Spinal Interfacing via Muscle Recordings for Neuroprosthesis Control
Muceli, S., & Farina, D. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_29-1 · Cited by 2
Sun, Y., Gao, Y., Shen, A., Sun, J., Chen, X., & Gao, X. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116882 · Cited by 2
Metadata
- Authors
- Maynard, E. M., Nordhausen, C. T., & Normann, R. A.
- Affiliations
- University of Utah (US)
- Corresponding author
- Normann, Richard A.
- Venue
- Electroencephalography and Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 1997-03
- Volume
- 102
- Issue
- 3
- Pages
- 228-239
- ISSN
- 0013-4694 (ISSN-L)
- OpenAlex
- W2020769260
- Semantic Scholar
- 8c017a2d9f35afc32fabba0f5b65a52191c82682
- Cited by
- 640
- References
- 37
- Citations by year
- 2026: 20 · 2025: 48 · 2024: 34 · 2023: 39 · 2022: 35 · 2021: 34 · 2020: 26 · 2019: 27 · 2018: 31 · 2017: 41 · 2016: 29 · 2015: 22 · 2014: 26 · 2013: 18 · 2012: 22
- FWCI
- 3.63
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Electroencephalography and Clinical Neurophysiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Keywords
- brain-computer interface, intracortical microelectrode arrays, signal-to-noise ratio, stimulus detection, neural decoding
- MeSH terms
- Action Potentials, Animals, Brain, Cats, Computers, Microelectrodes, Neurons
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.