The Utah Intracortical Electrode Array: A recording structure for potential brain-computer interfaces
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
We investigated the potential of the Utah Intracortical Electrode Array (UIEA) to provide signals for a brain-computer interface (BCI). The UIEA records from small populations of neurons which have an average signal-to-noise ratio (SNR) of 6:1. We provide specific examples that show the activities of these populations of neurons contain sufficient information to perform control tasks. Results from a simple stimulus detection task using these signals as inputs confirm that the number of neurons present in a recording is significant in determining task performance. Increasing the number of units in a recording decreases the sensitivity of the response to the stimulus; decreasing the number of units in the recording, however, increases the variability of the response to the stimulus. We conclude that recordings from small populations of neurons, not single units, provide a reliable source of sufficiently stimulus selective signals which should be suitable for a BCI. In addition, the potential for simultaneous and proportional control of a large number of external devices may be realized through the ability of an array of microelectrodes such as the UIEA to record both spatial and temporal patterns of neuronal activation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Traditional commercial implantable neural interfaces (e.g., Utah electrodes[306] and Michigan electrodes[307]) typically contain noble metals[308] (high conductivity and chemical stability), and silicon-based materials[309] (ideally suited to existing microfabrication techniques) as electrodes.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [306]
Citations
Cites
Receptive fields, binocular interaction and functional architecture in the cat’s visual cortex
Hubel, D. H., & Wiesel, T. N. (1962) · The Journal of Physiology · doi:10.1113/jphysiol.1962.sp006837 · Cited by 13,680
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
Neuronal Population Coding of Movement Direction
Georgopoulos, A. P., Schwartz, A. B., & Kettner, R. E. (1986) · Science · doi:10.1126/science.3749885 · Cited by 3,161
The two-dimensional spatial structure of simple receptive fields in cat striate cortex
Jones, J. P., & Palmer, L. A. (1987) · Journal of Neurophysiology · doi:10.1152/jn.1987.58.6.1187 · Cited by 668
Size, laminar and columnar distribution of efferent cells in the sensory‐motor cortex of monkeys
Jones, E. G., & Wise, S. P. (1977) · Journal of Comparative Neurology · doi:10.1002/cne.901750403 · Cited by 508
Electrophysiology of a Dendritic Neuron Model
Rall, W. (1962) · Biophysical Journal · doi:10.1016/s0006-3495(62)86953-7 · Cited by 492
The Motor Cortex and the Coding of Force
Georgopoulos, A. P., Ashe, J., Smyrnis, N., & Taira, M. (1992) · Science · doi:10.1126/science.256.5064.1692 · Cited by 460
Multichannel EEG-based brain-computer communication
Wolpaw, J. R., & McFarland, D. J. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90135-x · Cited by 449
A three-dimensional microelectrode array for chronic neural recording
Hoogerwerf, A. C., & Wise, K. D. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.335862 · Cited by 371
Predicting Measures of Motor Performance from Multiple Cortical Spike Trains
Humphrey, D. R., Schmidt, E. M., & Thompson, W. D. (1970) · Science · doi:10.1126/science.170.3959.758 · Cited by 370
Research works printed but not linked: 2
- Heetderks, 1995, Command-control signals from the neural activity of motor cortical cells: joy-stick control, Vol. 15, 664
- Humphrey, 1995, Intracortical recording of brain activity for control of limb prostheses, Vol. 15, 650
Cited by
Items 101–200 of 684
Advances in Magnetoresistive Biosensors
Su, D., Wu, K., Saha, R., Peng, C., & Wang, J. (2019) · Micromachines · doi:10.3390/mi11010034 · Cited by 106
Neural interfaces: Bridging the brain to the world beyond healthcare
Xu, S., Liu, Y., Lee, H., & Li, W. (2024) · Exploration · doi:10.1002/exp.20230146 · Cited by 118
Review: Human Intracortical Recording and Neural Decoding for Brain–Computer Interfaces
Brandman, D. M., Cash, S. S., & Hochberg, L. R. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2677443 · Cited by 103
“Importantly, neurons recorded on adjacent electrodes separated by micrometers [64] may display highly”
Bioelectronic Implantable Devices for Physiological Signal Recording and Closed‐Loop Neuromodulation
Oh, S., Jekal, J., Liu, J., Kim, J., Park, J., Lee, T., & Jang, K. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202403562 · Cited by 114
Asynchronous Decoding of Dexterous Finger Movements Using M1 Neurons
Aggarwal, V., Acharya, S., Tenore, F., Shin, H.-C., Etienne-Cummings, R., Schieber, M. H., & Thakor, N. V. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.916289 · Cited by 99
“It is important to note, however, that we used sequentially recorded single-unit activities from task-related neurons, and not simultaneously recorded neuronal activity as would be obtained using implanted microelectrode arrays such as the Utah Array [ 29 ].”
MethodIntraocular Retinal Prosthesis
Humayun, M. S. (2015) · Springer eBooks · doi:10.1007/978-1-4614-6675-8_100279 · Cited by 104
Parkinsonism Alters Beta Burst Dynamics across the Basal Ganglia–Motor Cortical Network
Yu, Y., Sanabria, D. E., Wang, J., Hendrix, C. M., Zhang, J., Nebeck, S. D., Amundson, A. M., Busby, Z., Bauer, D. L., Johnson, M. D., et al. (2021) · Journal of Neuroscience · doi:10.1523/jneurosci.1591-20.2021 · Cited by 106
Walking by Thinking: The Brainwaves Are Crucial, Not the Muscles!
Leeb, R., Keinrath, C., Friedman, D., Guger, C., Scherer, R., Neuper, C., Garau, M., Antley, A., Steed, A., Slater, M., et al. (2006) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.15.5.500 · Cited by 98
Azemi, E., Stauffer, W. R., Gostock, M. S., Lagenaur, C. F., & Cui, X. T. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.02.028 · Cited by 97
Tissue-engineered peripheral nerve interfaces
Spearman, B. S., Desai, V. H., Mobini, S., McDermott, M. D., Graham, J. B., Otto, K. J., Judy, J. W., & Schmidt, C. E. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701713 · Cited by 96
Margalit, E., Weiland, J. D., Clatterbuck, R. E., Fujii, G. Y., Maia, M., Tameesh, M., Torres, G. F., D’Anna, S. A., Desai, S., Piyathaisere, D. V., et al. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00345-x · Cited by 96
Paraskevopoulou, S. E., Barsakcioglu, D. Y., Saberi, M. R., Eftekhar, A., & Constandinou, T. G. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.01.012 · Cited by 98
A high-density 1,024-channel probe for brain-wide recordings in non-human primates
Liu, Y., Jia, H., Sun, H., Jia, S., Yang, Z., Li, A., Jiang, A., Naya, Y., Yang, C., Xue, S., et al. (2024) · Nature Neuroscience · doi:10.1038/s41593-024-01692-6 · Cited by 94
Artificial vision through neuronal stimulation
Fernandes, R. A. B., Diniz, B., Ribeiro, R., & Humayun, M. (2012) · Neuroscience Letters · doi:10.1016/j.neulet.2012.01.063 · Cited by 90
The Emergence of Single Neurons in Clinical Neurology
Cash, S. S., & Hochberg, L. R. (2015) · Neuron · doi:10.1016/j.neuron.2015.03.058 · Cited by 87
A Wireless Implantable Microsystem for Multichannel Neural Recording
Sodagar, A. M., Wise, K. D., & Najafi, K. (2009) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2009.2029957 · Cited by 90
“High-density penetrating arrays of silicon-based microelectrodes [8], [ 9 ] record the microvolt signals generated by ionic”
BackgroundCorrelated variability modifies working memory fidelity in primate prefrontal neuronal ensembles
Leavitt, M. L., Pieper, F., Sachs, A. J., & Martínez-Trujillo, J. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1619949114 · Cited by 97
“27 and 45, we chronically implanted a 10 × 10, 1.5-mm microelectrode array (Blackrock Microsystems LLC) (52, 53) in each monkey’s left LPFC—anterior to the knee of the arcuate sulcus and caudal to the posterior end of the principal sulcus (area 8a) (Fig.”
InfluentialNeural Decoding for Intracortical Brain–Computer Interfaces
Dong, Y., Wang, S., Huang, Q., Berg, R. W., Li, G., & He, J. (2023) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0044 · Cited by 92
“Highdensity MEAs, like Utah electrodes [14], Citation: Dong Y, Wang S, Huang Q,”
BackgroundA Flexible Depth Probe Using Liquid Crystal Polymer
Lee, S. E., Jun, S. B., Lee, H. J., Kim, J., Lee, S. W., Im, C., Shin, H.-C., Chang, J. W., & Kim, S. J. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2196274 · Cited by 83
Statistical Encoding Model for a Primary Motor Cortical Brain-Machine Interface
Shoham, S., Paninski, L., Fellows, M. R., Hatsopoulos, N. G., Donoghue, J. P., & Normann, R. A. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847542 · Cited by 90
“A number of long-term studies have established the chronic recording capability of this electrode-array [22], [23], and an ongoing research effort is underway to establish its efficacy in an implantable brain-machine interface [14], [24].”
BackgroundSelf-citationEncoding of Coordinated Reach and Grasp Trajectories in Primary Motor Cortex
Saleh, M., Takahashi, K., & Hatsopoulos, N. G. (2012) · Journal of Neuroscience · doi:10.1523/jneurosci.2438-11.2012 · Cited by 97
Retinal prostheses: progress toward the next generation implants
Ghezzi, D. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00290 · Cited by 83
“9:290. doi: 10.3389/fnins.2015.00290 Retinal prostheses: progress toward the next generation implants”
BackgroundMethodInfluentialTonet, O., Marinelli, M., Citi, L., Rossini, P. M., Rossini, L., Megali, G., & Dario, P. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.015 · Cited by 94
“Commonly used intracortical electrodes are microwires (Marg and Adams, 1967), multiple electrode arrays (MEAs) (Maynard et al., 1997), and neurotrophic electrodes (Kennedy, 1989).”
BackgroundOng, J. M., & da Cruz, L. (2011) · Clinical and Experimental Ophthalmology · doi:10.1111/j.1442-9071.2011.02590.x · Cited by 95
“Current models of the intracortical prosthesis includes the IIlinois Intracortical Visual Prosthesis Project and the Utah Electrode Array (UEA).(12,18,76,77) Following the Food and Drug Administration approval, the Utah Electrode Array has been recently undergone short-term implantation in human subjects.”
BackgroundMethodBlood brain barrier (BBB)-disruption in intracortical silicon microelectrode implants
Bennett, C., Samikkannu, M., Mohammed, F. S., Dietrich, W. D., Rajguru, S. M., & Prasad, A. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.02.036 · Cited by 85
Multi-scale analysis of neural activity in humans: Implications for micro-scale electrocorticography
Kellis, S., Sorensen, L. B., Darvas, F., Sayres, C., O’Neill, K., Brown, R. B., House, P. A., Ojemann, J. G., & Greger, B. E. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.06.002 · Cited by 89
“The microelectrode array (MEA) (Nordhausen et al., 1994, 1996; Maynard et al., 1997) (Fig.”
Microelectrode Array Fabrication by Electrical Discharge Machining and Chemical Etching
Fofonoff, T., Martel, S. M., Hatsopoulos, N. G., Donoghue, J. P., & Hunter, I. W. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826679 · Cited by 79
A comparison of insertion methods for surgical placement of penetrating neural interfaces
Thielen, B., & Meng, E. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf6f2 · Cited by 68
In Vivo Magnetic Recording of Neuronal Activity
Caruso, L., Wunderle, T., Lewis, C., Valadeiro, J. P., Trauchessec, V., Rosillo, J. T., Amaral, J., Ni, J., Jendritza, P., Fermon, C., et al. (2017) · Neuron · doi:10.1016/j.neuron.2017.08.012 · Cited by 85
Continuing progress of spike sorting in the era of big data
Carlson, D., & Carin, L. (2019) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2019.02.007 · Cited by 86
Direct Activation of Primary Motor Cortex during Subthalamic But Not Pallidal Deep Brain Stimulation
Johnson, L. A., Wang, J., Nebeck, S. D., Zhang, J., Johnson, M. D., & Vitek, J. L. (2020) · Journal of Neuroscience · doi:10.1523/jneurosci.2480-19.2020 · Cited by 77
“5 mm depth, 400 m inter-electrode spacing; Blackrock Microsystems) using surgical methods described previously (Rousche and Normann, 1992; Maynard et al., 1997).”
MethodInfluentialThe effects of chronic intracortical microstimulation on neural tissue and fine motor behavior
Rajan, A. T., Boback, J. L., Dammann, J. F., Tenore, F. V., Wester, B. A., Otto, K. J., Gaunt, R. A., & Bensmaia, S. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/6/066018 · Cited by 76
Can One Concurrently Record Electrical Spikes from Every Neuron in a Mammalian Brain?
Kleinfeld, D., Luan, L., Mitra, P. P., Robinson, J. T., Sarpeshkar, R., Shepard, K. L., Xie, C., & Harris, T. D. (2019) · Neuron · doi:10.1016/j.neuron.2019.08.011 · Cited by 83
Signal acquisition of brain–computer interfaces: A medical-engineering crossover perspective review
Sun, Y., Chen, X., Liu, B., Liang, L., Wang, Y., Gao, S., & Gao, X. (2024) · Fundamental Research · doi:10.1016/j.fmre.2024.04.011 · Cited by 85
“The cortical signal category ʼs representative technologies are Neuralink [135] , Neural Dust [140] , and MEAs [141] . sEEG [159] , Neuropixels [167] , and fully implantable BCI [168] belong to the depth signal category.”
BioMEA™: A versatile high-density 3D microelectrode array system using integrated electronics
Charvet, G., Rousseau, L., Billoint, O., Gharbi, S., Rostaing, J.-P., Joucla, S., Trevisiol, M., Bourgerette, A., Chauvet, P., Moulin, C., et al. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.01.001 · Cited by 79
Retinal Prostheses for the Blind
Javaheri, M., Hahn, D., Lakhanpal, R. R., Weiland, J. D., & Humayun, M. S. (2006) · Annals of the Academy of Medicine Singapore · doi:10.47102/annals-acadmedsg.v35n3p137 · Cited by 89
Optimal use of EEG recordings to target active brain areas with transcranial electrical stimulation
Dmochowski, J., Koessler, L., Norcia, A. M., Bikson, M., & Parra, L. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.05.059 · Cited by 85
“The technical capability to perform integrated stimulation-recording of brain activity exists at a variety of scales: invasive microelectrode arrays (Maynard et al., 1997; Jimbo et al., 2003; Dostrovsky et al., 2000), deep brain stimulation (DBS) (Kent and Grill, 2013; Lempka and McIntyre, 2013;…”
BackgroundThree-dimensional micro-electrode array for recording dissociated neuronal cultures
Musick, K. M., Khatami, D., & Wheeler, B. C. (2009) · Lab on a Chip · doi:10.1039/b820596e · Cited by 79
Reagentless aptamer based impedance biosensor for monitoring a neuro-inflammatory cytokine PDGF
Liao, W., & Cui, X. T. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.04.004 · Cited by 78
Soft Electronics Based on Stretchable and Conductive Nanocomposites for Biomedical Applications
Zambrano, B. L., Renz, A. F., Ruff, T., Lienemann, S., Tybrandt, K., Vörös, J., & Lee, J. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202001397 · Cited by 76
Yang, S. M., Shim, J. H., Cho, H., Jang, T., Ko, G., Shim, J., Kim, T. H., Zhu, J., Park, S. U., Kim, Y. S., et al. (2022) · Advanced Materials · doi:10.1002/adma.202108203 · Cited by 75
Young, A. T., Cornwell, N., & Daniele, M. A.-A. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201700239 · Cited by 79
Intraocular retinal prosthesis
Weiland, J. D., & Humayun, M. S. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1705748 · Cited by 71
Motor Variability Arises from a Slow Random Walk in Neural State
Chaisanguanthum, K. S., Shen, H. H., & Sabes, P. N. (2014) · Journal of Neuroscience · doi:10.1523/jneurosci.3001-13.2014 · Cited by 82
Heim, M., Yvert, B., & Kuhn, A. (2011) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2011.10.001 · Cited by 88
“A variety of different MEA layouts were fabricated using lithographic techniques, reflecting a wide spectrum of in vitro or in vivo applications (Bai et al., 2000; Egert et al., 1998; Maynard et al., 1997).”
BackgroundMicrostimulation in auditory cortex provides a substrate for detailed behaviors
Otto, K. J., Rousche, P. J., & Kipke, D. R. (2005) · Hearing Research · doi:10.1016/j.heares.2005.08.004 · Cited by 75
“The detailed resolution of penetrating cortical microstimulation for stimulus discrimination requires further investigation using microelectrode arrays with uniform spatial layouts (Maynard et al., 1997; Wise and Angell, 1975).”
MethodHeim, M., Rousseau, L., Reculusa, S., Urbanova, V., Mazzocco, C., Joucla, S., Bouffier, L., Vytras, K., Bartlett, P., Kuhn, A., et al. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00711.2011 · Cited by 60
“Likewise, in vivo devices also offer an increasing number of channels (Csicsvari et al. 2003; Maynard et al. 1997; Nicolelis et al. 1997; Yao et al. 2007) with improved action potential discrimination obtained with dense arrays of closely spaced microelectrodes.”
BackgroundAcharya, S., Tenore, F., Aggarwal, V., Etienne-Cummings, R., Schieber, M. H., & Thakor, N. V. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.916269 · Cited by 74
“One of the earliest microelectrode arrays developed is the Utah Electrode Array [Fig.”
MethodSilicon Carbide Technology for Advanced Human Healthcare Applications
Saddow, S. E. (2022) · Micromachines · doi:10.3390/mi13030346 · Cited by 70
“The only neural implant approv d for limited u an use to date is based on the University of Utah intracortical array [49].”
MethodFlexible, scalable, high channel count stereo-electrode for recording in the human brain
Lee, K., Paulk, A. C., Ro, Y. G., Cleary, D. R., Tonsfeldt, K. J., Kfir, Y., Pezaris, J. S., Tchoe, Y., Lee, J., Bourhis, A. M., et al. (2024) · Nature Communications · doi:10.1038/s41467-023-43727-9 · Cited by 64
“19 – 21).”
BackgroundStability of chronic multichannel neural recordings: Implications for a long-term neural interface
Williams, J. C., Rennaker, R. L., & Kipke, D. R. (1999) · Neurocomputing · doi:10.1016/s0925-2312(99)00106-x · Cited by 69
“Our current series of implants, with the relatively simple microwire electrode array provide a reference mark by which the recording performance of other types of implantable electrode systems can be evaluated [4,5,7].”
BackgroundSaleem, A. B., Chadderton, P., Apergis-Schoute, J., Harris, K. D., & Schultz, S. R. (2010) · Journal of Computational Neuroscience · doi:10.1007/s10827-010-0228-5 · Cited by 64
“Recent technological advances are improving our ability to record well isolated spike trains from a large population of simultaneously recorded neurons using multi-electrode array recordings (Harris et al. 2000; Quiroga et al. 2004; Blanche et al. 2005; Maynard et al. 1997).”
Bidirectional brain-computer interfaces
Hughes, C. L., Herrera, A. J., Gaunt, R. A., & Collinger, J. L. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00013-5 · Cited by 82
Aoyagi, Y., Stein, R. B., Branner, A., Pearson, K. G., & Normann, R. A. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00143-2 · Cited by 68
“It can also record single-and multi-unit neural activity in sensory and motor cortex (Maynard et al., 1999, 1997; Normann et al., 1999; Rousche and Normann, 1998, 1999).”
BackgroundSelf-citationNoninvasive Brain–Machine Interfaces for Robotic Devices
Tonin, L., & Millán, J. D. R. (2020) · Annual Review of Control Robotics and Autonomous Systems · doi:10.1146/annurev-control-012720-093904 · Cited by 76
Translation of neurotechnologies
Schalk, G., Brunner, P., Allison, B. Z., Soekadar, S. R., Guan, C., Denison, T., Rickert, J., & Miller, K. J. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00185-2 · Cited by 74
Westwick, D. T., Pohlmeyer, E. A., Solla, S. A., Miller, L. E., & Perreault, E. J. (2005) · Neural Computation · doi:10.1162/089976606775093855 · Cited by 72
“Recent advances in microelectrode array technology have made it possible to record from multiple neurons simultaneously (Maynard, Nordhausen, & Normann, 1997; Williams, Rennaker, & Kipke, 1999; Nicolelis et al., 2003).”
BackgroundMisra, A., Burke, J. F., Ramayya, A. G., Jacobs, J., Sperling, M. R., Moxon, K. A., Kahana, M. J., Evans, J. J., & Sharan, A. D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026013 · Cited by 66
“While numerous studies have employed either multielectrode arrays (cortical recordings) [4] or micro-wire bundles (mesial structure recordings) [5–8] to record single neuron activity in humans, few provide specific methodological details about the required troubleshooting approaches for successful recordings, especial…”
BackgroundZhang, S., Song, Y., Wang, M., Zhang, Z., Fan, X., Song, X., Zhuang, P., Yue, F., Chan, P., & Cai, X. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.04.087 · Cited by 65
Bistability of prefrontal states gates access to consciousness
Dwarakanath, A., Kapoor, V., Werner, J., Safavi, S., Fedorov, L., Logothetis, N. K., & Panagiotaropoulos, T. I. (2023) · Neuron · doi:10.1016/j.neuron.2023.02.027 · Cited by 68
Aristovich, K. Y., dos Santos, G. S., Packham, B., & Holder, D. S. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/6/1095 · Cited by 67
Encoding of Coordinated Grasp Trajectories in Primary Motor Cortex
Saleh, M., Takahashi, K., Amit, Y., & Hatsopoulos, N. G. (2010) · Journal of Neuroscience · doi:10.1523/jneurosci.2558-10.2010 · Cited by 69
“Maryam Saleh,1 Kazutaka Takahashi,2 Yali Amit,3,4 and Nicholas G. Hatsopoulos1,2 1Committee on Computational Neuroscience, 2Department of Organismal Biology and Anatomy, and Departments of 3Statistics and 4Computer Science,”
BackgroundMethodCassar, I. R., Yu, C., Sambangi, J., Lee, C. D., Whalen, J. J., Petrossians, A., & Grill, W. M. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.03.017 · Cited by 66
Advances in the development of visual prostheses
Lakhanpal, R. R., Yanai, D., Weiland, J. D., Fujii, G. Y., Caffey, S., Greenberg, R. J., de Juan, & Humayun, M. S. (2003) · Current Opinion in Ophthalmology · doi:10.1097/00055735-200306000-00002 · Cited by 61
Wang, D., Zhang, Q., Li, Y., Wang, Y., Zhu, J., Zhang, S., & Zheng, X. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/036009 · Cited by 58
Dowling, J. (2005) · Expert Review of Medical Devices · doi:10.1586/17434440.2.1.73 · Cited by 58
Jeon, M., Cho, J., Kim, Y. K., Jung, D., Yoon, E.-S., Shin, S., & Cho, I.-J. (2014) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/2/025010 · Cited by 61
Trends and recent development of the microelectrode arrays (MEAs)
Xu, L., Hu, C., Huang, Q., Jin, K., Zhao, P., Wang, D., Hou, W., Dong, L., Hu, S., & Ma, H. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112854 · Cited by 63
Neurolight: A Deep Learning Neural Interface for Cortical Visual Prostheses
Lozano, A., Suárez, J. S., Soto-Sánchez, C., Garrigós, J., Martínez-Alvarez, J. J., Ferrández, J. M., & Fernández, E. (2020) · International Journal of Neural Systems · doi:10.1142/s0129065720500458 · Cited by 57
Tremblay, S., Doucet, G., Pieper, F., Sachs, A. J., & Martínez-Trujillo, J. (2015) · Journal of Neuroscience · doi:10.1523/jneurosci.1041-15.2015 · Cited by 58
“However, one potential problem with the use of spike signals recorded from chronic MEAs is that the isolation of single neurons deteriorates over short time periods (Dickey et al., 2009; Chestek et al., 2011; Perge et al., 2013), leaving LFPs as the only detectable signal.”
BackgroundInfluentialChapter 63 Development of neuromotor prostheses for humans
Donoghue, J. P., Nurmikko, A. V., Friehs, G. M., & Black, M. J. (2004) · Supplements to Clinical neurophysiology · doi:10.1016/s1567-424x(09)70399-x · Cited by 64
“Recently the Brown group has successfully attached a microscale, fully operational 16 channel amplifier and signal multiplexing integrated circuit directly onto a Utah array (Patterson et al., 2003).”
Automatic spike sorting for neural decoding
Wood, E., Fellows, M. R., Donoghue, J. P., & Black, M. J. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404120 · Cited by 57
“Technologies LLC (BTL) 100-electrode silicon array [6] was”
BackgroundSignal Generation, Acquisition, and Processing in Brain Machine Interfaces: A Unified Review
Salahuddin, U., & Gao, P. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.728178 · Cited by 65
“A typical 10 by 10 grid of Utah array electrodes is 4.2 mm wide and 1.2 mm in length (Maynard et al., 1997).”
BackgroundInfluentialSeo, K. J., Artoni, P., Qiang, Y., Zhong, Y., Han, X., Shi, Z., Yao, W., Fagiolini, M., & Fang, H. (2019) · Advanced Biosystems · doi:10.1002/adbi.201800276 · Cited by 53
Donati, E., & Indiveri, G. (2023) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/acb51c · Cited by 56
“Floating microelectrode arrays [51] and Utah electrode arrays [52] are extensively used in neuroscientific research.”
BackgroundSanabria, D. E., Johnson, L. A., Nebeck, S. D., Zhang, J., Johnson, M. D., Baker, K. B., Molnar, G. F., & Vitek, J. L. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00388.2017 · Cited by 52
Acquisition of Neural Action Potentials Using Rapid Multiplexing Directly at the Electrodes
Sharma, M., Gardner, A. T., Strathman, H. J., Warren, D. J., Silver, J., & Walker, R. M. (2018) · Micromachines · doi:10.3390/mi9100477 · Cited by 55
“Figure 3a,b shows in vitro and in vivo spectral measurements of a representative 16-channel tungsten microwire array (Tucker-Davis Technologies, Alachua, FL, USA) and a representative 16-channel silicon “Utah” microelectrode array [42] (Blackrock Microsystems, Salt Lake City, UT, USA), respectively.”
BackgroundThe present and future of neural interfaces
Valeriani, D., Santoro, F., & Ienca, M. (2022) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2022.953968 · Cited by 53
A wireless subdural-contained brain–computer interface with 65,536 electrodes and 1,024 channels
Jung, T., Zeng, N., Fabbri, J. D., Eichler, G., Li, Z., Zabeh, E., Das, A., Willeke, K. F., Wingel, K., Dubey, A., et al. (2025) · Nature Electronics · doi:10.1038/s41928-025-01509-9 · Cited by 59
Tecchio, F., Porcaro, C., Barbati, G., & Zappasodi, F. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2007.129163 · Cited by 52
Sombeck, J. T., Heye, J. O., Kumaravelu, K., Goetz, S. M., Peterchev, A. V., Grill, W. M., Bensmaïa, S. J., & Miller, L. E. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac63e8 · Cited by 52
Tomsett, R. J., Ainsworth, M., Thiele, A., Sanayei, M., Chen, X., Gieselmann, M. A., Whittington, M. A., Cunningham, M. O., & Kaiser, M. (2014) · Brain Structure and Function · doi:10.1007/s00429-014-0793-x · Cited by 52
“2009, 2012), and for use in brain machine interfaces (Maynard et al. 1997; Andersen et al. 2004).”
BackgroundModified Neuropixels probes for recording human neurophysiology in the operating room
Coughlin, B. F., Muñoz, W., Kfir, Y., Young, M. J., Meszéna, D., Jamali, M., Caprara, I., Hardstone, R., Khanna, A. R., Mustroph, M. L., et al. (2023) · Nature Protocols · doi:10.1038/s41596-023-00871-2 · Cited by 51
Herring, E. Z., Graczyk, E. L., Memberg, W. D., Adams, R., Baca-Vaca, G. F., Hutchison, B. C., Krall, J. T., Alexander, B. J., Conlan, E. C., Alfaro, K. E., et al. (2023) · Neurosurgery · doi:10.1227/neu.0000000000002769 · Cited by 49
“21,22 The hand-related area of primary somatosensory cortex was identi fi ed through awake sensory mapping, in which 4 of the 5 fi ngers were localized(Figure 2A and 2B).”
BackgroundEngineering brain-on-a-chip platforms
Servais, B., Mahmoudi, N., Gautam, V., Tong, W., Ibbotson, M. R., Nisbet, D. R., & Collins, D. J. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00184-3 · Cited by 50
Infrared neuromodulation:a neuroengineering perspective
Fekete, Z., Horváth, Á. C., & Zátonyi, A. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abb3b2 · Cited by 47
Gao, W., Yan, Z., Zhou, H., Xie, Y., Wang, H., Yang, J., Yu, J., Ni, C., Liu, P., Xie, M., et al. (2025) · Journal of Nanobiotechnology · doi:10.1186/s12951-025-03573-x · Cited by 51
“Noteworthy developments in this domain include the Michigan-style probe, pioneered at the University of Michigan in 1971, and the Utah electrode, developed at the University of Utah in 1992 [29, 30].”
Closed-loop, ultraprecise, automated craniotomies
Pak, N., Siegle, J. H., Kinney, J. P., Denman, D. J., Blanche, T. J., & Boyden, E. S. (2015) · Journal of Neurophysiology · doi:10.1152/jn.01055.2014 · Cited by 48
“…allows many small precisely spaced craniotomies to be drilled, which may be useful for deploying multi-injector (Chan et al. 2010), multi-electrode (Maynard et al. 1997; Recce and O’Keefe 1989; Scholvin et al. 2015), or multi-optical fiber (Zorzos et al. 2012) probes for interrogating distributed…”
BackgroundRabbit and monkey visual cortex: more than a year of recording with up to 64 microelectrodes
Porada, I., Bondar, I. V., Spatz, W. B., & Krüger, J. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(99)00139-9 · Cited by 44
“Their implantation into loci at the brain surface were typically performed under direct visual control (Burns et al., 1974; Salcman and Bak, 1976; Schmidt et al., 1976, 1993, 1996; Legendy et al., 1984; Mioche and Singer, 1988, 1989; Palmer, 1990; Adelson et al., 1995; Maynard et al., 1997).”
BackgroundMethodGuger, C., Schlogl, A., Walterspacher, D., & Pfurtscheller, G. (1999) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1999.44.1-2.12 · Cited by 44
Schnitker, J., Adly, N., Seyock, S., Bachmann, B., Yakushenko, A., Wolfrum, B. L., & Offenhäusser, A. (2018) · Advanced Biosystems · doi:10.1002/adbi.201700136 · Cited by 46
Tomsett, R., Ainsworth, M., Thiele, A., Sanayei, M., A Gieselmann, M., Whittington, M. A., O Cunningham, M., & Kaiser, M. (2014) · Figshare · doi:10.6084/m9.figshare.1088264 · Cited by 43
Flexible Microinterventional Sensors for Advanced Biosignal Monitoring
Liu, Y., Fan, P., Pan, Y., & Ping, J. F. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.5c00115 · Cited by 43
Kassegne, S., Vomero, M., Gavuglio, R., Hirabayashi, M., Özyilmaz, E., Nguyen, S. D. K. N., Rodríguez, J., Özyilmaz, E., van Niekerk, P., & Khosla, A. (2014) · Microelectronic Engineering · doi:10.1016/j.mee.2014.11.013 · Cited by 50
Biohybrid neural interfaces: improving the biological integration of neural implants
Boulingre, M., Lara, R. P., & Green, R. A. (2023) · Chemical Communications · doi:10.1039/d3cc05006h · Cited by 44
Bjånes, D. A., Kellis, S., Nickl, R., Baker, B., Aflalo, T., Bashford, L., Chivukula, S., Fifer, M. S., Osborn, L. E., Christie, B., et al. (2025) · Acta Biomaterialia · doi:10.1016/j.actbio.2025.02.030 · Cited by 43
“Three human participants with C5-C6 level spinal cord injury were consented and chronically implanted with NeuroPort arrays [1,42,62].”
Technology and Signal Processing for Brain-Machine Interfaces
Sanchez, J. C., Príncipe, J. C., Nishida, T., Bashirullah, R., Harris, J. G., & Fortes, J. A. B. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408440 · Cited by 43
Diamond-on-Polymer Microelectrode Arrays Fabricated Using a Chemical Release Transfer Process
Hess‐Dunning, A., Sabens, D., Martin, H. B., & Zorman, C. A. (2011) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2011.2159099 · Cited by 42
Brain-Machine Interface Engineering
Sanchez, J. C., & Príncipe, J. C. (2007) · Synthesis lectures on biomedical engineering · doi:10.1007/978-3-031-01621-9 · Cited by 44
van der Grinten, M., de Ruyter van Steveninck, J., Lozano, A., Pijnacker, L., Rueckauer, B., Roelfsema, P., van Gerven, M., van Wezel, R., Güçlü, U., & Güçlütürk, Y. (2024) · eLife · doi:10.7554/elife.85812 · Cited by 39
“Right: Example renderings after initializing the simulator with four 10 × 10 electrode arrays (indicated with roman numerals) placed in the right hemisphere (electrode spacing: 0.4 mm, in correspondence with the commonly used ‘Utah array’ Maynard et al., 1997 ).”
MethodInfluential
Metadata
- Authors
- Maynard, E. M., Nordhausen, C. T., & Normann, R. A.
- Affiliations
- University of Utah (US)
- Corresponding author
- Normann, Richard A.
- Venue
- Electroencephalography and Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 1997-03
- Volume
- 102
- Issue
- 3
- Pages
- 228-239
- ISSN
- 0013-4694 (ISSN-L)
- OpenAlex
- W2020769260
- Semantic Scholar
- 8c017a2d9f35afc32fabba0f5b65a52191c82682
- Cited by
- 640
- References
- 37
- Citations by year
- 2026: 20 · 2025: 48 · 2024: 34 · 2023: 39 · 2022: 35 · 2021: 34 · 2020: 26 · 2019: 27 · 2018: 31 · 2017: 41 · 2016: 29 · 2015: 22 · 2014: 26 · 2013: 18 · 2012: 22
- FWCI
- 3.63
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Electroencephalography and Clinical Neurophysiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Keywords
- brain-computer interface, intracortical microelectrode arrays, signal-to-noise ratio, stimulus detection, neural decoding
- MeSH terms
- Action Potentials, Animals, Brain, Cats, Computers, Microelectrodes, Neurons
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.