Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trial
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Background Tight control of blood glucose in type 1 diabetes delays onset of macrovascular and microvascular diabetic complications; however, glucose levels need to be closely monitored to prevent hypoglycaemia. We aimed to assess whether a factory-calibrated, sensor-based, flash glucose-monitoring system compared with self-monitored glucose testing reduced exposure to hypoglycaemia in patients with type 1 diabetes. Method In this multicentre, prospective, non-masked, randomised controlled trial, we enrolled adult patients with well controlled type 1 diabetes (HbA 1c ≤58 mmol/mol [7·5%]) from 23 European diabetes centres. After 2 weeks of all participants wearing the blinded sensor, those with readings for at least 50% of the period were randomly assigned (1:1) to flash sensor-based glucose monitoring (intervention group) or to self-monitoring of blood glucose with capillary strips (control group). Randomisation was done centrally using the biased-coin minimisation method dependent on study centre and type of insulin administration. Participants, investigators, and study staff were not masked to group allocation. The primary outcome was change in time in hypoglycaemia ( Findings Between Sept 4, 2014, and Feb 12, 2015, we enrolled 328 participants. After the screening and baseline phase, 120 participants were randomly assigned to the intervention group and 121 to the control group, with outcomes being evaluated in 119 and 120, respectively. Mean time in hypoglycaemia changed f…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The clinical efficacy of CGM has been demonstrated in numerous retrospective studies and RCTs of individuals with T1D regardless of insulin delivery method.156–161”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [161]
In the citing paper
“Numerous studies have demonstrated significant clinical benefits of CGM use in people with diabetes regardless of insulin delivery method (1-15).”
From Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range (2019) · cites this paper as [8]
In the citing paper
“One RCT showed less time in the hypoglycemic range, without significant change in HbA 1c (163).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [163]
In the citing paper
“One study was performed in adults with type 1 diabetes and met its primary outcome of a reduction in rates of hypoglycemia (68).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [68]
In the citing paper
“Real-time CGM studies can be divided into studies with elevated A1C with the primary end point of A1C reduction and studies with A1C near target with the primary end point of reduction in hypoglycemia (98, 109-124).”
From 6. Glycemic Targets: Standards of Care in Diabetes—2023 (2023) · cites this paper as [113]
Citations
Cites
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
Assessing Psychosocial Distress in Diabetes
Polonsky, W. H., Fisher, L., Earles, J., Dudl, R. J., Lees, J., Mullan, J., & Jackson, R. A. (2005) · Diabetes Care · doi:10.2337/diacare.28.3.626 · Cited by 1,575
Defining and Reporting Hypoglycemia in Diabetes
American Diabetes Association Workgroup on Hypoglycemia (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1245 · Cited by 1,146
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894
Risk of hypoglycaemia in types 1 and 2 diabetes: Effects of treatment modalities and their duration
UK Hypoglycaemia Study Group (2007) · Diabetologia · doi:10.1007/s00125-007-0599-y · Cited by 825
Epidemiology of severe hypoglycemia in the diabetes control and complications trial
(1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)80085-z · Cited by 807
Epidemiology of severe hypoglycemia in the Diabetes Control and Complications Trial
(1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)90605-w · Cited by 807
Continuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities
Rodbard, D. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0417 · Cited by 737
Threshold-based insulin-pump interruption for reduction of hypoglycemia
Bergenstal, R. M., Klonoff, D. C., Garg, S. K., Bode, B. W., Meredith, M., Slover, R. H., Ahmann, A. J., Welsh, J. B., Lee, S. W., & Kaufman, F. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1303576 · Cited by 652
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
Research works printed but not linked: 1
- 1997, Hypoglycaemia in the diabetes, control and complications trial, Diabetes, 46, 272
Cited by
Items 701–800 of 891
Mustonen, J., Rautiainen, P., Lamidi, M., Lavikainen, P., Martikainen, J. A., & Laatikainen, T. K. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0102 · Cited by 2
Koshmeleva, M. V., Samoilova, I., Fomina, S., Trifonova, E. A., Kachanov, D., Эдуардовна, Ю. В., Kudlay, D. A., Koshkarova, M., Pogosyan, L. A., & Novoselova, E. (2023) · Molekulyarnaya Meditsina (Molecular medicine) · doi:10.29296/24999490-2023-06-02 · Cited by 2
L’internista ospedaliero nella gestione del paziente diabetico complesso
Magnani, G. E. L., Beltramello, G., Brancato, D., Fontanella, A., & Nardi, R. (2018) · Italian Journal of Medicine · doi:10.4081/itjm.q.2018.2 · Cited by 2
Glucose Management Using Continuous Glucose Monitors
Kang, Y. (2019) · Journal of Korean Diabetes · doi:10.4093/jkd.2019.20.1.42 · Cited by 2
Schütz-Fuhrmann, I., Rami-Merhar, B. M., Hofer, S. E., Fröhlich-Reiterer, E. E., Mader, J. K., Stadler, M., Bischof, M. G., Zlamal-Fortunat, S., Laimer, M. W., & Weitgasser, R. (2019) · Wiener klinische Wochenschrift · doi:10.1007/s00508-019-1465-x · Cited by 2
Self-citationA qualitative evaluation of patients’ perspectives of the FreeStyle Libre flash glucose monitor
Gleeson, A., Davies, M., Roberts, B., & Nugent, A. (2019) · British Journal of Diabetes · doi:10.15277/bjd.2019.225 · Cited by 5
Riveline, J., Guerci, B., Wojtusciszyn, A., & Dunn, T. C. (2020) · Médecine des Maladies Métaboliques · doi:10.1016/j.mmm.2020.08.001 · Cited by 5
Everett, C., Reynolds, C., Fernandez, C., Stocken, D. D., Sharples, L. D., Sathyapalan, T., Heller, S. R., Storey, R. F., & Ajjan, R. (2020) · Diabetes and Vascular Disease Research · doi:10.1177/1479164120957934 · Cited by 2
Glucose sensing technology—current practice?
Forde, H. E., Browne, S., Smith, D., & Tormey, W. P. (2018) · Irish Journal of Medical Science (1971 -) · doi:10.1007/s11845-018-1800-7 · Cited by 3
Continuous Glucose Monitors for Insulin Dosing
Beck, R. W. (2018) · JAMA · doi:10.1001/jama.2018.0185 · Cited by 2
Grino, M., Alitta, Q., & Oliver, C. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818805749 · Cited by 2
Zafra‐Tanaka, J. H., Brañez‐Condorena, A., Soriano‐Moreno, D. R., & Taype-Rondán, Á. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820952065 · Cited by 4
Brohi, A. H., Hakim, A., Khan, M. J., Malik, E., Mugheri, D., Shaikh, F., Abbas, W., Baloch, N., Ashraf, Z., Mangi, A. A., et al. (2020) · Research Square · doi:10.21203/rs.3.rs-35708/v1 · Cited by 3
(2018) · Diabetes Case Reports · doi:10.4172/2572-5629 · Cited by 2
Montesinos, S. P., Morano, C., & Díez, L.-R. (2022) · Primary care diabetes · doi:10.1016/j.pcd.2022.03.011 · Cited by 2
Relationship Between Time in Range and Dusk Phenomenon in Outpatients with Type 2 Diabetes Mellitus
Gao, X., Li, H., Yu, Y., Huai, X., Feng, B., & Song, J. (2023) · Diabetes Metabolic Syndrome and Obesity · doi:10.2147/dmso.s410761 · Cited by 1
2023 Clinical Practice Guidelines for Diabetes: Continuous Glucose Monitoring and Insulin Pumps
Jin, S. (2023) · Journal of Korean Diabetes · doi:10.4093/jkd.2023.24.3.141 · Cited by 2
McFadden, N. T., Wilkerson, A. H., Chaney, B. H., Carmack, H. J., Jaiswal, J., Stellefson, M., & Lovett, K. (2024) · The Science of Diabetes Self-Management and Care · doi:10.1177/26350106241268412 · Cited by 3
Dong, L., Li, J., Hu, Y., Chai, R., Zhu, Y. F., Zhu, L., Fan, N., Zhang, Z., Pan, J., Yan, J., et al. (2024) · Frontiers in Endocrinology · doi:10.3389/fendo.2024.1464755 · Cited by 1
Matter, R. M., Amin, G. E. E.-D., Youssef, N. R., & Fereig, Y. A. (2025) · Journal of Pediatric Endocrinology and Metabolism · doi:10.1515/jpem-2024-0437 · Cited by 1
Cai, Q., Zhao, P., Chen, X., Yu, S., Guo, L., & Pan, Q. (2025) · Aging Medicine · doi:10.1002/agm2.70044 · Cited by 3
Bakrey, H., Abdelaziz, M. A. A., Magbool, F. F., Bakrey, A., Omer, O. I. A., Abdelrahim, I., & Abdu, A. (2025) · AAPS PharmSciTech · doi:10.1208/s12249-025-03285-3 · Cited by 2
Cigler, M., el Hakouni, O., Meçani, R., Pouwer, F., Abbink, E. J., Moser, M., de Galan, B. E., Renard, É., Evans, M. L., Brøsen, J. M. B., et al. (2026) · Diabetic Medicine · doi:10.1111/dme.70301 · Cited by 1
Should all patients on insulin be using continuous glucose monitoring?
Distiller, L. A. (2018) · Journal of Endocrinology Metabolism and Diabetes of South Africa · doi:10.1080/16089677.2018.1515164 · Cited by 1
Filho, I. D. M. B., de Aquino, G. S., & de Lima, M. A. (2017) · Advances in medical technologies and clinical practice book series · doi:10.4018/978-1-5225-2851-7.ch001 · Cited by 1
Wearable Technologies for Glucose Monitoring: A Systematic Mapping Study of Publication Trends
Iyawa, G. E., Velusamy, V., & Palanisamy, S. (2019) · Advances in web technologies and engineering book series · doi:10.4018/978-1-5225-9246-4.ch007 · Cited by 3
Wo steht das künstliche Pankreas in der Diabetestherapie?
Dimou, M., Laimer, M. W., Stettler, C., & Bally, L. (2019) · Der Internist · doi:10.1007/s00108-019-00713-y · Cited by 1
Linton, K., Stimson, R. H., Dover, A. R., Forbes, S., Madill, K., Annoh, R., Strachan, M. W. J., McKnight, J. A., Wright, R. J., & Gibb, F. W. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296821994091 · Cited by 1
Out-of-Hospital Management of Diabetic Emergencies in Germany: Structural and Process Quality
Holstein, D. J. F., Holstein, J. D., Fischer, D., Mende, M., Frier, B. M., & Holstein, A. (2021) · Experimental and Clinical Endocrinology & Diabetes · doi:10.1055/a-1523-7562 · Cited by 1
Mateu-Salat, M., Moreno-Fernández, J., Mangas, N., Genua, I., Martínez, M. J., López, A., González, C., & Chico, A. I. (2021) · Endocrinología Diabetes y Nutrición · doi:10.1016/j.endinu.2021.04.008 · Cited by 2
Monitoreo Continuo de Glucosa. ¿Qué evidencia tenemos en pediatría?
Ayala, D. V. S., Forero, C., Mauricio Coll, B., Durán, P. A., & Céspedes, C. (2021) · Andes pediatrica · doi:10.32641/andespediatr.v92i4.2973 · Cited by 5
Predictors of change in hypoglycemia unawareness among patients with type 1 diabetes
Melnychuk, J., Wyne, K. L., & Dungan, K. M. (2022) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.3582 · Cited by 1
Peculiarities of using personal continuous glucose monitoring in children and adolescents
Velychko, V. I., Lahoda, D. O., Amirova, G. Y., Bazhora, Y. I., Shapovalov, O. O., Shpak, O. A., & Sydor, O. M. (2022) · CHILD`S HEALTH · doi:10.22141/2224-0551.17.6.2022.1527 · Cited by 1
Ólafsdóttir, A. F., & Lind, M. (2023) · Frontiers in Clinical Diabetes and Healthcare · doi:10.3389/fcdhc.2023.1247616 · Cited by 1
The Application of Digital Health in Diabetes Management
Ye, J. (2023) · Highlights in Science Engineering and Technology · doi:10.54097/hset.v66i.11711 · Cited by 1
An Analysis of the Distribution of Direct Cost of Diabetes Care in Selected Districts in Italy
Mennini, F. S., Sciattella, P., Marcellusi, A., Bartolini, F., Bernardi, F. F., Levrat‐Guillen, F., Cozzolino, M., Gennaro, M. D., Giordana, R., Giustozzi, M., et al. (2024) · Diabetes Therapy · doi:10.1007/s13300-024-01580-z · Cited by 1
Salasa, W., Seredyński, T., Mądry, W., Mazurkiewicz, A., Kołodziej, M., Męczyńska, J., Saiuk, N., Kozicz, M. A., Wojciechowska, A., & Marcicka, J. (2024) · Journal of Education Health and Sport · doi:10.12775/jehs.2024.67.50885 · Cited by 1
Štechová, K., Kovács, R., Tuháčková, M., Salátová, M., Malá, Š., Piťhová, P., & Pichlerová, D. (2024) · Kontakt · doi:10.32725/kont.2024.028 · Cited by 1
“Since the first blood glucose monitoring (FGM) system was launched in autumn 2014, several studies have been published on the system’s effectiveness and safety (Bolinder et al., 2016; Deshmukh et al., 2020; Evans et al., 2020; Messaaoui et al., 2019).”
Dei, A., Aldigeri, R., Bellei, G., Raffaeli, D., Bartolo, P. D., Sforza, A., Marchesini, G., Ciardullo, A. V., Manicardi, V., Bianco, M., et al. (2024) · Acta Diabetologica · doi:10.1007/s00592-024-02298-x · Cited by 2
Muayyad, M., Abusnana, S., Mussa, B. M., Helal, R., Abdelrahim, D. N., Reheim, N. M. A., Amiri, E. A., Daboul, M. M., Al-Abadla, Z., Lessan, N. G., et al. (2024) · Journal of Education and Health Promotion · doi:10.4103/jehp.jehp_1609_23 · Cited by 1
Gölz, S., Mader, J. K., Bilz, S., Kenzler, J., & Danne, T. (2024) · Diabetes Therapy · doi:10.1007/s13300-024-01670-y · Cited by 1
“The use of these devices has shown benefits in terms of glycemic control, has improved the quality of life, and has reduced glycated hemoglobin (HbA 1c ) and mean glucose in people with diabetes mellitus [4–7].”
Sebastián‐Valles, F., Martín, J. A. A., Alfonso, J. M., Jiménez‐Díaz, J., Alday, I. H., Navas-Moreno, V., Joya, T. A., García, M., Gómez, G. L. R., Hierro, J. G., et al. (2024) · Endocrinology Diabetes & Metabolism · doi:10.1002/edm2.70020 · Cited by 1
Status of Continuous Glucose Monitoring Technology in Clinical Practice
O’Connor, C., & Aleppo, G. (2019) · doi:10.2337/9781580406932.part1_ch04 · Cited by 1
Nishibeppu, K., Kubota, T., Nakabayashi, Y., Inoue, H., Takabatake, K., Ohashi, T., Konishi, H., Shiozaki, A., Fujiwara, H., & Otsuji, E. (2025) · Surgery Today · doi:10.1007/s00595-025-03015-z · Cited by 1
Dynamic Interference Testing Results with the Dexcom G6 Continuous Glucose Monitoring Device
Thomé, N., Jensch, H., Srikanthamoorthy, G., Weingärtner, L., Grady, M., Setford, S. J., Holt, E., & Pfützner, A. (2025) · Diabetes Technology and Obesity Medicine · doi:10.1089/dtom.2024.0009 · Cited by 1
Navrátilová, V., Zadáková, E., Šoupal, J., Škrha, J., Do, Q. D., Radovnická, L., Hašková, A., Prázný, M., & Horová, E. (2025) · Endocrinology Diabetes & Metabolism · doi:10.1002/edm2.70047 · Cited by 2
Highlights from the Diabetes UK Professional Conference 2017
David, F. (2017) · Practical Diabetes · doi:10.1002/pdi.2095 · Cited by 1
New technologies and metabolic control in type 1 diabetes mellitus
Klamann, M., & Majkowska, L. (2017) · Clinical Diabetology · doi:10.5603/dk.2017.0018 · Cited by 1
Relevancia del monitoreo continuo de glucosa en la práctica clínica: revisión de la evidencia
Gómez, A. M., Carrillo, D. C. H., Tapoada, L., & Toro, M. R. (2018) · Revista Colombiana de Endocrinología Diabetes & Metabolismo · doi:10.53853/encr.5.3.432 · Cited by 3
Monitoraggio in continuo del glucosio: il ruolo della tecnologia nella gestione del diabete mellito
Laviola, L., Lisco, G., & Giorgino, F. (2019) · L Endocrinologo · doi:10.1007/s40619-019-00598-x · Cited by 1
Raddatz, A. (2019) · Springer eBooks · doi:10.1007/978-3-658-25141-3_9 · Cited by 1
Ali, M. A.-D., Stimson, R. H., Dover, A. R., Forbes, S., Annoh, R., Madill, K., & Gibb, F. W. (2020) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2020-001668 · Cited by 1
“2 RCT evidence attests to reduction in hypoglycemia (and glucose variability) during flash monitoring use 6 in individuals with on-target HbA1c at baseline and similar findings have emerged from a large French observational study with respect to severe hypoglycemia.”
The individualized statistical analysis of the continuous glucose monitoring data
Dreval', A. V., Shestakova, T. P., Manukyan, A. A., & Brezhneva, O. G. (2020) · Almanac of Clinical Medicine · doi:10.18786/2072-0505-2020-48-068 · Cited by 1
Expanding Flash Continuous Glucose Monitoring Technology to a Broader Population
Cowart, K. (2021) · Clinical Diabetes · doi:10.2337/cd20-0066 · Cited by 2
Garden, G. L., Hunt, D. W., Mackie, K., Tuthill, B., Griffith, H., Russell-Jones, D. L., & Herring, R. A. (2021) · British Journal of Diabetes · doi:10.15277/bjd.2021.284 · Cited by 1
Flash Glucose Monitoring Experiences of the Families of the Patient with Type 1 Diabetes Mellitus
Eren, E., & Tarım, Ö. (2017) · Güncel Pediatri · doi:10.4274/jcp.2017.0026 · Cited by 1
L'insulinothérapie au xxie siècle : une symphonie de plus en plus harmonieuse
Benhamou, P., Hanaire, H. P., & Renard, É. (2021) · Médecine des Maladies Métaboliques · doi:10.1016/s1957-2557(21)00179-6 · Cited by 1
Association between Flash Glucose Monitors and A1C: A Retrospective Pre-Post Analysis
Tekarli, M., Turner, K. M., & Witt, D. M. (2021) · INNOVATIONS in pharmacy · doi:10.24926/iip.v12i3.3977 · Cited by 1
Diabetes and mental health: management in primary care
Morris, D. (2021) · Independent Nurse · doi:10.12968/indn.2021.9.16 · Cited by 1
de la Marca, M. D. L. O. N., Díaz-Soto, G., Ibáñez, M. S., Simón, S. D. A., Fernández-Velasco, P., Torres, B., Gómez, J. J. L., Hoyos, E. G., Buigues, A. O., García, E. D., et al. (2022) · Endocrinología Diabetes y Nutrición · doi:10.1016/j.endinu.2022.01.003 · Cited by 2
Seven facts you need to know about continuous glucose monitors
Solano, L. (2022) · JAAPA · doi:10.1097/01.jaa.0000854536.09072.5e · Cited by 1
Hellmund, R., Blissett, D. B., & Levrat‐Guillen, F. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818822513 · Cited by 1
Kandiyali, R., & Taylor, H. (2022) · medRxiv · doi:10.1101/2022.11.22.22281186 · Cited by 1
Almokayyad, R. M., & Cuddihy, R. M. (2021) · Wiley eBooks · doi:10.1002/9781119603207.ch7
Novel Glucose Monitor Helps Avoid Hypoglycemia in Adults with Well-Controlled Type 1 Diabetes
Soloway, B. (2016) · Journal watch · doi:10.1056/nejm-jw.na42317
Weniger Hypoglykämien durch unblutige Glukosemessung
Jäger-Becker, D. (2016) · Info Diabetologie · doi:10.1007/s15034-016-0965-2
Ce que la mesure en continu du glucose apporte à la pompe à insuline
Hanaire, H. P. (2016) · Médecine des Maladies Métaboliques · doi:10.1016/s1957-2557(16)30189-4
Update from the Insulin Pump Network UK
Wilmot, E. G. (2016) · British Journal of Diabetes · doi:10.15277/bjd.2016.100
Weniger Hypoglykämien mit neuem Blutzuckersensor bei Typ-1-Diabetes
Siegmund, T. (2017) · Diabetologie und Stoffwechsel · doi:10.1055/s-0043-102256
Aguilera, E., & Vázquez, F. (2017) · Endocrinología Diabetes y Nutrición · doi:10.1016/j.endinu.2017.02.001 · Cited by 1
Aguilera, E., & Vázquez, F. (2017) · Endocrinología Diabetes y Nutrición (English ed ) · doi:10.1016/j.endien.2017.02.008
Avancées dans la prise en charge du diabète
Sicard, J. (2017) · Actualités Pharmaceutiques · doi:10.1016/j.actpha.2017.07.007
Reply to Argento. Flash forward, with caution
Leelarathna, L., & Wilmot, E. G. (2018) · Diabetic Medicine · doi:10.1111/dme.13655
Corrao, S., Nativo, B., Natoli, G., Monaco, M. L., & Perticone, F. (2018) · Internal and Emergency Medicine · doi:10.1007/s11739-018-1855-5
Reduktion des kardiovaskulären Risikos
Siegmund, T. (2018) · CardioVasc · doi:10.1007/s15027-018-1367-2
Koide, K., Azuma, K., Nojima, J., Kodama, K., & Atsumi, Y. (2018) · Diabetology & Metabolic Syndrome · doi:10.1186/s13098-018-0364-z · Cited by 1
Technologische Innovationen in der Diabetes-Therapie
Strey, C. H. (2018) · Praxis · doi:10.1024/1661-8157/a003058
Die neue Flash-Glukosemessung kann auch Alarm schlagen
Pampel, S. L. (2018) · Info Diabetologie · doi:10.1007/s15034-018-1425-y
Consider alternative evidence sources for medical devices
Smart, N. J. (2018) · BMJ · doi:10.1136/bmj.k5202
Newer Modalities in the Treatment of Type 2 Diabetes Mellitus: Focus on Technology
Schorr, A. B. (2019) · IntechOpen eBooks · doi:10.5772/intechopen.84285
Continuous and flash glucose monitoring in diabetes
Morris, D. (2019) · Journal of Prescribing Practice · doi:10.12968/jprp.2019.1.sup3.s3
Progress in Device for Treatment of Diabetes
Nishimura, R. (2018) · Nihon Naika Gakkai Zasshi · doi:10.2169/naika.107.586
Point-of-care testing in diabetes management
Cozma, A., Vonica, C. L., Sitar-Tăut, A., & Fodor, A. (2019) · Revista română de medicină de laborator · doi:10.2478/rrlm-2019-0014
Grassi, B. A., Tapia, L., Aracena, I., Astudillo, R., Kara, F., Aliste, M., Onetto, M. T., & Matamala, P. M. (2019) · Revista médica de Chile · doi:10.4067/s0034-98872019000400451 · Cited by 2
Neue Technologien in der Diabetestherapie
Serfling, G., Kalscheuer, H., Schmid, S. M., & Lehnert, H. (2019) · Der Internist · doi:10.1007/s00108-019-0654-z · Cited by 1
Hypoglykämien bei Diabetes mellitus: häufig und gefährlich
Holstein, A., & Holstein, D. J. F. (2019) · Diabetes aktuell · doi:10.1055/a-1031-2237
Problem solving in type 1 diabetes for primary care nurses–part 2
Morris, D. (2019) · Independent Nurse · doi:10.12968/indn.2019.12.25
Problem solving in type 1 diabetes for primary care nurses
Morris, D. (2019) · Independent Nurse · doi:10.12968/indn.2019.9.4 · Cited by 3
Microneedle mediated optical detection of glucose concentration in aqueous solutions
Nicholas, D. (2019) · Ulster University Research Portal (Ulster University)
Staltari, B. J., Cutó, F. G., Benkovic, R. I., Loredo, S. D., & Loredo, L. D. (2020) · Alad · doi:10.24875/alad.20000407
Morohoshi, H., Tsunoda, K., Ryu, K., Machino, H., Sambe, T., & Kobayashi, S. (2020) · Rinsho yakuri/Japanese Journal of Clinical Pharmacology and Therapeutics · doi:10.3999/jscpt.51.51
Uduku, C. N., Reddy, M., & Oliver, N. S. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-816714-4.00007-7
Part I: Continuous glucose monitoring systems
Moorman, J. M. (2020) · JACCP JOURNAL OF THE AMERICAN COLLEGE OF CLINICAL PHARMACY · doi:10.1002/jac5.1260
CGM-101: How to Identify Appropriate Use
Howell, C., & Meredith, A. H. (2020) · ADCES in Practice · doi:10.1177/2633559x20925456
Qiang, W., Chen, X., Gao, C., Wang, Z., Shang, J., Fu, J., & Guo, H. (2020) · Therapeutic Advances in Endocrinology and Metabolism · doi:10.1177/2042018820938236
Kostev, K., & van den Boom, L. (2020) · Monitor Versorgungsforschung · doi:10.24945/mvf.03.20.1866-0533.2243
Zelinska, P. B. N. B. (2020) · Ukrainian Journal of Pediatric Endocrinology · doi:10.30978/ujpe2020-3-26
Marsters, B. L. (2020) · Otago University Research Archive (University of Otago)
McCarthy, O. M., Deere, R., Eckstein, M. L., Pitt, J. P., Wellman, B., Bain, S. C., Moser, O., & Bracken, R. M. (2021) · Frontiers in Public Health · doi:10.3389/fpubh.2020.568832
Flash Glucose Monitoring(FGM)時代の血糖値の分類 ―低血糖・血糖値スパイクを中心に―
勝太郎, 永., 悟子, 志., 大槻, 千., & 喜山, 克. (2021) · doi:10.32183/ifcm.19.1_21
Metadata
- Authors
- Bolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R.
- Affiliations
- Karolinska University Hospital (SE)
- Medisch Centrum Haaglanden (NL)
- Paracelsus Medical University (AT)
- Corresponding author
- Bolinder, Jan
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2016-11
- Volume
- 388
- Issue
- 10057
- Pages
- 2254-2263
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2519526531
- Semantic Scholar
- b7578dcd738c57d556845ed4e8c554c14d7d0830
- Cited by
- 893
- References
- 35
- Citations by year
- 2026: 20 · 2025: 55 · 2024: 68 · 2023: 92 · 2022: 121 · 2021: 133 · 2020: 124 · 2019: 113 · 2018: 92 · 2017: 63 · 2016: 10
- FWCI
- 93.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Abbott Diabetes Care
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- type 1 diabetes, hypoglycemia, flash glucose monitoring, continuous glucose monitoring, self-monitoring of blood glucose, HbA1c, insulin dose adjustment, glycated albumin
- MeSH terms
- Blood Glucose, Diabetes Mellitus, Type 1, Drug Administration Schedule, Glycated Hemoglobin, Humans, Hypoglycemia, Hypoglycemic Agents, Insulin, Monitoring, Physiologic, Inventions
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.