Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trial
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Background Tight control of blood glucose in type 1 diabetes delays onset of macrovascular and microvascular diabetic complications; however, glucose levels need to be closely monitored to prevent hypoglycaemia. We aimed to assess whether a factory-calibrated, sensor-based, flash glucose-monitoring system compared with self-monitored glucose testing reduced exposure to hypoglycaemia in patients with type 1 diabetes. Method In this multicentre, prospective, non-masked, randomised controlled trial, we enrolled adult patients with well controlled type 1 diabetes (HbA 1c ≤58 mmol/mol [7·5%]) from 23 European diabetes centres. After 2 weeks of all participants wearing the blinded sensor, those with readings for at least 50% of the period were randomly assigned (1:1) to flash sensor-based glucose monitoring (intervention group) or to self-monitoring of blood glucose with capillary strips (control group). Randomisation was done centrally using the biased-coin minimisation method dependent on study centre and type of insulin administration. Participants, investigators, and study staff were not masked to group allocation. The primary outcome was change in time in hypoglycaemia ( Findings Between Sept 4, 2014, and Feb 12, 2015, we enrolled 328 participants. After the screening and baseline phase, 120 participants were randomly assigned to the intervention group and 121 to the control group, with outcomes being evaluated in 119 and 120, respectively. Mean time in hypoglycaemia changed f…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The clinical efficacy of CGM has been demonstrated in numerous retrospective studies and RCTs of individuals with T1D regardless of insulin delivery method.156–161”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [161]
In the citing paper
“Numerous studies have demonstrated significant clinical benefits of CGM use in people with diabetes regardless of insulin delivery method (1-15).”
From Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range (2019) · cites this paper as [8]
In the citing paper
“One RCT showed less time in the hypoglycemic range, without significant change in HbA 1c (163).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [163]
In the citing paper
“One study was performed in adults with type 1 diabetes and met its primary outcome of a reduction in rates of hypoglycemia (68).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [68]
In the citing paper
“Real-time CGM studies can be divided into studies with elevated A1C with the primary end point of A1C reduction and studies with A1C near target with the primary end point of reduction in hypoglycemia (98, 109-124).”
From 6. Glycemic Targets: Standards of Care in Diabetes—2023 (2023) · cites this paper as [113]
Citations
Cites
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
Assessing Psychosocial Distress in Diabetes
Polonsky, W. H., Fisher, L., Earles, J., Dudl, R. J., Lees, J., Mullan, J., & Jackson, R. A. (2005) · Diabetes Care · doi:10.2337/diacare.28.3.626 · Cited by 1,575
Defining and Reporting Hypoglycemia in Diabetes
American Diabetes Association Workgroup on Hypoglycemia (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1245 · Cited by 1,146
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894
Risk of hypoglycaemia in types 1 and 2 diabetes: Effects of treatment modalities and their duration
UK Hypoglycaemia Study Group (2007) · Diabetologia · doi:10.1007/s00125-007-0599-y · Cited by 825
Epidemiology of severe hypoglycemia in the diabetes control and complications trial
(1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)80085-z · Cited by 807
Epidemiology of severe hypoglycemia in the Diabetes Control and Complications Trial
(1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)90605-w · Cited by 807
Continuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities
Rodbard, D. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0417 · Cited by 737
Threshold-based insulin-pump interruption for reduction of hypoglycemia
Bergenstal, R. M., Klonoff, D. C., Garg, S. K., Bode, B. W., Meredith, M., Slover, R. H., Ahmann, A. J., Welsh, J. B., Lee, S. W., & Kaufman, F. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1303576 · Cited by 652
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
Research works printed but not linked: 1
- 1997, Hypoglycaemia in the diabetes, control and complications trial, Diabetes, 46, 272
Cited by
Cosentino, F., Grant, P. J., Aboyans, V., Bailey, C. J., Ceriello, A., Delgado, V., Federici, M., Filippatos, G., Grobbee, D. E., Hansen, T. B., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz486 · Cited by 4,763
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069
“severe hypoglycemia (26-37) [C,C,B,B,C,C,A,C,B,C,B].”
6. Glycemic Targets: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s006 · Cited by 1,403
6. Glycemic Targets: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s006 · Cited by 847
Continuous glucose monitoring and metrics for clinical trials: an international consensus statement
Battelino, T., Alexander, C. M., Amiel, S. A., Arreaza-Rubin, G., Beck, R. W., Bergenstal, R. M., Buckingham, B. A., Carroll, J., Ceriello, A., Chow, E., et al. (2023) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(22)00319-9 · Cited by 831
Feig, D. S., Donovan, L. E., Corcoy, R., Murphy, K. E., Amiel, S. A., Hunt, K. F., Asztalos, E., Barrett, J. F. R., Sanchez, J. J., de Leiva, A., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32400-5 · Cited by 803
6. Glycemic Targets: Standards of Medical Care in Diabetes—2018
American Diabetes Association (2018) · Diabetes Care · doi:10.2337/dc18-s006 · Cited by 762
“tes found that flash CGM users spent less time in hypoglycemia than those using SMBG (19).”
Holt, R. I. G., DeVries, J. H., Hess-Fischl, A., Hirsch, I. B., Kirkman, M. S., Klupa, T., Ludwig, B., Nørgaard, K., Pettus, J., Renard, E., et al. (2021) · Diabetes Care · doi:10.2337/dci21-0043 · Cited by 699
6. Glycemic Targets: Standards of Care in Diabetes—2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s006 · Cited by 684
Haak, T., Hanaire, H., Ajjan, R., Hermanns, N., Riveline, J.-P., & Rayman, G. (2017) · Diabetes Therapy · doi:10.1007/s13300-016-0223-6 · Cited by 623
“demonstrated superior reduction in hypoglycemia without deterioration of HbA1c and improved treatment satisfaction [34].”
DiMeglio, L. A., Acerini, C. L., Codner, E., Craig, M. E., Hofer, S. E., Pillay, K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12737 · Cited by 604
“The system has acceptable accuracy compared with capillary (75-78) measurements, which has led to approval of both versions in more than 30 countries (79).”
InfluentialJapanese clinical practice guideline for diabetes 2019
Araki, E., Goto, A., Kondo, T., Noda, M., Noto, H., Origasa, H., Osawa, H., Taguchi, A., Tanizawa, Y., Tobe, K., et al. (2020) · Diabetology International · doi:10.1007/s13340-020-00439-5 · Cited by 545
Martens, T., Beck, R. W., Bailey, R., Ruedy, K. J., Calhoun, P., Peters, A. L., Pop-Busui, R., Philis-Tsimikas, A., Bao, S., Umpierrez, G., et al. (2021) · JAMA · doi:10.1001/jama.2021.7444 · Cited by 543
Lu, J., Ma, X., Zhou, J., Zhang, L., Mo, Y., Ying, L., Lu, W., Zhu, W., Bao, Y., Vigersky, R. A., et al. (2018) · Diabetes Care · doi:10.2337/dc18-1131 · Cited by 517
Blonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507
Continuous glucose monitoring: a review of recent studies demonstrating improved glycemic outcomes
Rodbard, D. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0035 · Cited by 458
“S5 of Bolinder et al. 42 ) and participants were aware of reduced hypoglycemia.”
InfluentialHolt, R. I. G., DeVries, J. H., Hess-Fischl, A., Hirsch, I. B., Kirkman, M. S., Klupa, T., Ludwig, B., Nørgaard, K., Pettus, J., Renard, E., et al. (2021) · Diabetologia · doi:10.1007/s00125-021-05568-3 · Cited by 378
7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
Polonsky, W. H., Hessler, D., Ruedy, K. J., & Beck, R. W. (2017) · Diabetes Care · doi:10.2337/dc17-0133 · Cited by 346
“lels the negative findings from three of the four published CGM trials that examined hypoglycemic worry (1,3,5), the one exception being the study by van Beers et al.”
Japanese Clinical Practice Guideline for Diabetes 2019
Araki, E., Goto, A., Kondo, T., Noda, M., Noto, H., Origasa, H., Osawa, H., Taguchi, A., Tanizawa, Y., Tobe, K., et al. (2020) · Journal of Diabetes Investigation · doi:10.1111/jdi.13306 · Cited by 341
Shan, R., Sarkar, S., & Martin, S. S. (2019) · Diabetologia · doi:10.1007/s00125-019-4864-7 · Cited by 339
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351
Continuous glucose monitoring: A review of the technology and clinical use
Klonoff, D. C., Ahn, D., & Drincic, A. (2017) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.08.005 · Cited by 320
7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
Grunberger, G., Sherr, J., Allende, M., Blevins, T., Bode, B., Handelsman, Y., Hellman, R., Lajara, R., Roberts, V. L., Rodbard, D., et al. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.008 · Cited by 288
Lu, J., Wang, C., Shen, Y., Chen, L., Zhang, L., Cai, J., Lu, W., Zhu, W., Hu, G., Xia, T., et al. (2021) · Diabetes Care · doi:10.2337/dc20-1862 · Cited by 282
7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
Charleer, S., De Block, C., Van Huffel, L., Broos, B., Fieuws, S., Nobels, F., Mathieu, C., & Gillard, P. (2020) · Diabetes Care · doi:10.2337/dc19-1610 · Cited by 261
Reddy, M., Jugnee, N., El Laboudi, A., Spanudakis, E., Anantharaja, S., & Oliver, N. (2018) · Diabetic Medicine · doi:10.1111/dme.13561 · Cited by 245
Advances in technology for management of type 1 diabetes
Beck, R. W., Bergenstal, R. M., Laffel, L. M., & Pickup, J. C. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31142-0 · Cited by 242
Dunn, T. C., Xu, Y., Hayter, G., & Ajjan, R. A. (2018) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.12.015 · Cited by 239
Moser, O., Riddell, M. C., Eckstein, M. L., Adolfsson, P., Rabasa-Lhoret, R., van den Boom, L., Gillard, P., Nørgaard, K., Oliver, N. S., Zaharieva, D. P., et al. (2020) · Diabetologia · doi:10.1007/s00125-020-05263-9 · Cited by 214
Yaron, M., Roitman, E., Aharon-Hananel, G., Landau, Z., Ganz, T., Yanuv, I., Rozenberg, A., Karp, M., Ish-Shalom, M., Singer, J., et al. (2019) · Diabetes Care · doi:10.2337/dc18-0166 · Cited by 211
Choudhary, P., Kolassa, R., Keuthage, W., Kroeger, J., Thivolet, C., Evans, M., Ré, R., de Portu, S., Vorrink, L., Shin, J., et al. (2022) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(22)00212-1 · Cited by 204
7. Diabetes Technology: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s007 · Cited by 202
Measures of Accuracy for Continuous Glucose Monitoring and Blood Glucose Monitoring Devices
Freckmann, G., Pleus, S., Grady, M., Setford, S., & Levy, B. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818812062 · Cited by 202
Clinical Implications of Real-time and Intermittently Scanned Continuous Glucose Monitoring
Edelman, S. V., Argento, N. B., Pettus, J., & Hirsch, I. B. (2018) · Diabetes Care · doi:10.2337/dc18-1150 · Cited by 199
ISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
Continuous glucose monitoring: A review of the evidence in type 1 and 2 diabetes mellitus
Lin, R., Brown, F., James, S., Jones, J., & Ekinci, E. (2021) · Diabetic Medicine · doi:10.1111/dme.14528 · Cited by 197
Porumb, M., Stranges, S., Pescapè, A., & Pecchia, L. (2020) · Scientific Reports · doi:10.1038/s41598-019-56927-5 · Cited by 196
Haak, T., Hanaire, H., Ajjan, R., Hermanns, N., Riveline, J.-P., & Rayman, G. (2017) · Diabetes Therapy · doi:10.1007/s13300-017-0255-6 · Cited by 188
“There is little published data on using a device attached to the body with medical grade adhesive; the type of events in our study are similar to those reported for use of flash technology in adults with type 1 diabetes over 6 months [11] and for other systems with on-body sensor use [20, 21].”
Teo, E., Hassan, N., Tam, W., & Koh, S. (2022) · Diabetologia · doi:10.1007/s00125-021-05648-4 · Cited by 186
Evans, M., Welsh, Z., Ells, S., & Seibold, A. (2020) · Diabetes Therapy · doi:10.1007/s13300-019-00720-0 · Cited by 185
Wright, L. A.-C., & Hirsch, I. B. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0029 · Cited by 178
Bonora, B. M., Boscari, F., Avogaro, A., Bruttomesso, D., & Fadini, G. P. (2020) · Diabetes Therapy · doi:10.1007/s13300-020-00829-7 · Cited by 180
Continuous glucose monitoring sensors: past, present and future algorithmic challenges
Facchinetti, A. (2016) · Sensors · doi:10.3390/s16122093 · Cited by 176
Deshmukh, H., Wilmot, E. G., Gregory, R., Barnes, D., Narendran, P., Saunders, S., Furlong, N., Kamaruddin, S., Banatwalla, R., Herring, R., et al. (2020) · Diabetes Care · doi:10.2337/dc20-0738 · Cited by 175
Intermittently scanned continuous glucose monitoring for type 1 diabetes
Leelarathna, L., Evans, M. L., Neupane, S., Rayman, G., Lumley, S., Cranston, I., Narendran, P., Barnard-Kelly, K., Sutton, C. J., Elliott, R. A., et al. (2022) · New England Journal of Medicine · doi:10.1056/nejmoa2205650 · Cited by 174
Roussel, R., Riveline, J.-P., Vicaut, E., de Pouvourville, G., Detournay, B., Emery, C., Levrat-Guillen, F., & Guerci, B. (2021) · Diabetes Care · doi:10.2337/dc20-1690 · Cited by 173
Ólafsdóttir, A. F., Attvall, S., Sandgren, U., Dahlqvist, S., Pivodic, A., Skrtic, S., Theodorsson, E., & Lind, M. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0392 · Cited by 173
Positioning time in range in diabetes management
Advani, A. (2020) · Diabetologia · doi:10.1007/s00125-019-05027-0 · Cited by 170
Flash forward: a review of flash glucose monitoring
Leelarathna, L., & Wilmot, E. G. (2018) · Diabetic Medicine · doi:10.1111/dme.13584 · Cited by 167
Tyndall, V., Stimson, R. H., Zammitt, N. N., Ritchie, S. A., McKnight, J. A., Dover, A. R., & Gibb, F. W. (2019) · Diabetologia · doi:10.1007/s00125-019-4894-1 · Cited by 165
Visser, M. M., Charleer, S., Fieuws, S., De Block, C., Hilbrands, R., Van Huffel, L., Maes, T., Vanhaverbeke, G., Dirinck, E., Myngheer, N., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(21)00789-3 · Cited by 165
Alva, S., Bailey, T., Brazg, R., Budiman, E. S., Castorino, K., Christiansen, M. P., Forlenza, G., Kipnes, M., Liljenquist, D. R., & Liu, H. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820958754 · Cited by 164
Oskarsson, P., Antuna, R., Geelhoed-Duijvestijn, P., Krӧger, J., Weitgasser, R., & Bolinder, J. (2018) · Diabetologia · doi:10.1007/s00125-017-4527-5 · Cited by 160
Self-citationHypoglycemia in diabetes: An update on pathophysiology, treatment, and prevention
Nakhleh, A., & Shehadeh, N. (2021) · World Journal of Diabetes · doi:10.4239/wjd.v12.i12.2036 · Cited by 154
Wada, E., Onoue, T., Kobayashi, T., Handa, T., Hayase, A., Ito, M., Furukawa, M., Okuji, T., Okada, N., Iwama, S., et al. (2020) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2019-001115 · Cited by 157
“9 14 It is not clear from this study why the improved glycemic control was sustained even after the cessation of glucose monitoring in the FGM group.”
InfluentialTechnology in the management of type 1 diabetes mellitus — current status and future prospects
Tauschmann, M., & Hovorka, R. (2018) · Nature Reviews Endocrinology · doi:10.1038/s41574-018-0044-y · Cited by 185
Scott, E. M., Bilous, R. W., & Kautzky-Willer, A. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0386 · Cited by 153
Sacks, D. B., Arnold, M. A., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad080 · Cited by 208
Bally, L., Thabit, H., Kojzar, H., Mader, J. K., Qerimi-Hyseni, J., Hartnell, S., Tauschmann, M., Allen, J. M., Wilinska, M. E., Pieber, T. R., et al. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30001-3 · Cited by 150
Impact of COVID-19 lockdown on glycemic control in patients with type 1 diabetes
Fernández-Rubio, E., Cortázar, A., & Bellido, V. (2020) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2020.108348 · Cited by 149
“[11] Bolinder J, Antuna R, Geelhoed-Duijvestijn P, Kröger J, Weitgasser R.”
Self-charging wearables for continuous health monitoring
Kim, J., Khan, S. A., Wu, P. F., Park, S., Park, H., Yu, C., & Kim, W. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.105419 · Cited by 156
Hásková, A., Radovnická, L., Petruželková, L., Parkin, C. G., Grunberger, G., Horová, E., Navrátilová, V., Kádě, O., Matoulek, M., Prázný, M., et al. (2020) · Diabetes Care · doi:10.2337/dc20-0112 · Cited by 146
Improving the clinical value and utility of CGM systems: issues and recommendations
Petrie, J. R., Peters, A. L., Bergenstal, R. M., Holl, R. W., Fleming, G. A., & Heinemann, L. (2017) · Diabetologia · doi:10.1007/s00125-017-4463-4 · Cited by 149
Continuous glucose monitoring: The achievement of 100 years of innovation in diabetes technology
Galindo, R. J., & Aleppo, G. (2020) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2020.108502 · Cited by 133
Phillip, M., Bergenstal, R. M., Close, K. L., Danne, T., Garg, S. K., Heinemann, L., Hirsch, I. B., Kovatchev, B. P., Laffel, L. M., Mohan, V., et al. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0375 · Cited by 135
Improving the Clinical Value and Utility of CGM Systems: Issues and Recommendations
Petrie, J. R., Peters, A. L., Bergenstal, R. M., Holl, R. W., Fleming, G. A., & Heinemann, L. (2017) · Diabetes Care · doi:10.2337/dci17-0043 · Cited by 135
Barnard, K. D., Wysocki, T., Ully, V., Mader, J. K., Pieber, T. R., Thabit, H., Tauschmann, M., Leelarathna, L., Hartnell, S., Acerini, C. L., et al. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817702656 · Cited by 126
McCall, A. L., Lieb, D. C., Gianchandani, R., MacMaster, H., Maynard, G. A., Murad, M. H., Seaquist, E., Wolfsdorf, J. I., Wright, R. F., & Wiercioch, W. (2023) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgac596 · Cited by 123
2019 Guidelines on the management of diabetic patients. A position of Diabetes Poland
Araszkiewicz, A., Bandurska-Stankiewicz, E., Budzyński, A., Cypryk, K., Czech, A., Czupryniak, L., Drzewoski, J., Dzida, G., Dziedzic, T., Franek, E., et al. (2019) · Clinical Diabetology · doi:10.5603/dk.2019.0001 · Cited by 123
2023 Clinical Practice Guidelines for Diabetes Mellitus of the Korean Diabetes Association
Choi, J. H., Lee, K. A., Moon, J. H., Chon, S., Kim, D. J., Kim, H. J., Kim, N. H., Seo, J. A., Kim, M. K., Lim, J. H., et al. (2023) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2023.0282 · Cited by 150
Continuous Glucose Monitoring: A Brief Review for Primary Care Practitioners
Ajjan, R., Slattery, D., & Wright, E. (2019) · Advances in Therapy · doi:10.1007/s12325-019-0870-x · Cited by 120
Psychosocial impacts of hybrid closed‐loop systems in the management of diabetes: a review
Farrington, C. (2018) · Diabetic Medicine · doi:10.1111/dme.13567 · Cited by 121
Fuchigami, A., Shigiyama, F., Kitazawa, T., Okada, Y., Ichijo, T., Higa, M., Hiyoshi, T., Inoue, I., Iso, K., Yoshii, H., et al. (2020) · Cardiovascular Diabetology · doi:10.1186/s12933-019-0977-z · Cited by 133
Preserving Skin Integrity with Chronic Device Use in Diabetes
Messer, L. H., Berget, C., Beatson, C., Polsky, S., & Forlenza, G. P. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0080 · Cited by 113
Hermanns, N., Ehrmann, D., Schipfer, M., Kröger, J., Haak, T., & Kulzer, B. (2019) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2019.03.003 · Cited by 112
Self-citationZou, Y., Chu, Z., Guo, J., Liu, S., Ma, X., & Guo, J. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115103 · Cited by 131
Ajjan, R. A., Cummings, M. H., Jennings, P., Leelarathna, L., Rayman, G., & Wilmot, E. G. (2018) · Diabetes and Vascular Disease Research · doi:10.1177/1479164118756240 · Cited by 111
Bergenstal, R. M., Layne, J. E., Zisser, H., Gabbay, R. A., Barleen, N. A., Lee, A. A., Majithia, A. R., Parkin, C. G., & Dixon, R. F. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0396 · Cited by 110
Javaid, A., Zghyer, F., Kim, C., Spaulding, E. M., Isakadze, N., Ding, J., Kargilis, D., Gao, Y., Rahman, F., Brown, D. E., et al. (2022) · American Journal of Preventive Cardiology · doi:10.1016/j.ajpc.2022.100379 · Cited by 133
Dicembrini, I., Cosentino, C., Monami, M., Mannucci, E., & Pala, L. (2021) · Acta Diabetologica · doi:10.1007/s00592-020-01589-3 · Cited by 106
Johnson, M. L., Martens, T. W., Criego, A. B., Carlson, A. L., Simonson, G. D., & Bergenstal, R. M. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0034 · Cited by 104
Park, C., & Le, Q. A. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0177 · Cited by 104
Elbalshy, M., Haszard, J., Smith, H., Kuroko, S., Galland, B., Oliver, N., Shah, V., de Bock, M. I., & Wheeler, B. J. (2022) · Diabetic Medicine · doi:10.1111/dme.14854 · Cited by 104
Al Hayek, A. A., Robert, A. A., & Al Dawish, M. A. (2017) · Clinical Medicine Insights: Endocrinology and Diabetes · doi:10.1177/1179551417746957 · Cited by 103
Cystic Fibrosis-Related Diabetes
Kayani, K., Mohammed, R., & Mohiaddin, H. (2018) · Frontiers in Endocrinology · doi:10.3389/fendo.2018.00020 · Cited by 129
ISPAD Clinical Practice Consensus Guidelines 2022: Diabetes technologies: Glucose monitoring
Tauschmann, M., Forlenza, G., Hood, K., Cardona‐Hernandez, R., Giani, E., Hendrieckx, C., DeSalvo, D. J., Laffel, L. M., Saboo, B., Wheeler, B. J., et al. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13451 · Cited by 100
Campbell, F. M., Murphy, N. P., Stewart, C., Biester, T., & Kordonouri, O. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12735 · Cited by 102
How Can We Realize the Clinical Benefits of Continuous Glucose Monitoring?
Ajjan, R. A. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0021 · Cited by 97
“However, limited evidence from two RCTs suggests a benefit in both T1DM and T2DM patients on multiple daily injections with insulin.(65,66) The rapid increase in FCGM users will provide further crucial data on the role of this glucose monitoring strategy in optimizing glycemic control in diabetes.”
Approach to Using Trend Arrows in the FreeStyle Libre Flash Glucose Monitoring Systems in Adults
Kudva, Y. C., Ahmann, A. J., Bergenstal, R. M., Gavin, J. R., Kruger, D. F., Midyett, L. K., Miller, E., & Harris, D. R. (2018) · Journal of the Endocrine Society · doi:10.1210/js.2018-00294 · Cited by 97
Allergic contact dermatitis caused by medical devices for diabetes patients: A review
Herman, A., de Montjoye, L., Tromme, I., Goossens, A., & Baeck, M. (2018) · Contact Dermatitis · doi:10.1111/cod.13120 · Cited by 95
Flash glucose monitoring reduces glycemic variability and hypoglycemia: real-world data from Spain
Gomez-Peralta, F., Dunn, T., Landuyt, K., Xu, Y., & Merino-Torres, J. F. (2020) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2019-001052 · Cited by 94
Time in Range from Continuous Glucose Monitoring: A Novel Metric for Glycemic Control
Yoo, J. H., & Kim, J. H. (2020) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2020.0257 · Cited by 108
Technology in the management of type 2 diabetes: Present status and future prospects
DALY, A. B., & Hovorka, R. (2021) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14418 · Cited by 109
Speight, J., Choudhary, P., Wilmot, E. G., Hendrieckx, C., Forde, H., Cheung, W. Y., Crabtree, T., Millar, B., Traviss‐Turner, G., Hill, A., et al. (2023) · Diabetic Medicine · doi:10.1111/dme.14944 · Cited by 92
Reddy, M., Jugnee, N., Anantharaja, S., & Oliver, N. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0252 · Cited by 91
Metadata
- Authors
- Bolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R.
- Affiliations
- Karolinska University Hospital (SE)
- Medisch Centrum Haaglanden (NL)
- Paracelsus Medical University (AT)
- Corresponding author
- Bolinder, Jan
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2016-11
- Volume
- 388
- Issue
- 10057
- Pages
- 2254-2263
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2519526531
- Semantic Scholar
- b7578dcd738c57d556845ed4e8c554c14d7d0830
- Cited by
- 893
- References
- 35
- Citations by year
- 2026: 20 · 2025: 55 · 2024: 68 · 2023: 92 · 2022: 121 · 2021: 133 · 2020: 124 · 2019: 113 · 2018: 92 · 2017: 63 · 2016: 10
- FWCI
- 93.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Abbott Diabetes Care
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- type 1 diabetes, hypoglycemia, flash glucose monitoring, continuous glucose monitoring, self-monitoring of blood glucose, HbA1c, insulin dose adjustment, glycated albumin
- MeSH terms
- Blood Glucose, Diabetes Mellitus, Type 1, Drug Administration Schedule, Glycated Hemoglobin, Humans, Hypoglycemia, Hypoglycemic Agents, Insulin, Monitoring, Physiologic, Inventions
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.