Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trial
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Background Tight control of blood glucose in type 1 diabetes delays onset of macrovascular and microvascular diabetic complications; however, glucose levels need to be closely monitored to prevent hypoglycaemia. We aimed to assess whether a factory-calibrated, sensor-based, flash glucose-monitoring system compared with self-monitored glucose testing reduced exposure to hypoglycaemia in patients with type 1 diabetes. Method In this multicentre, prospective, non-masked, randomised controlled trial, we enrolled adult patients with well controlled type 1 diabetes (HbA 1c ≤58 mmol/mol [7·5%]) from 23 European diabetes centres. After 2 weeks of all participants wearing the blinded sensor, those with readings for at least 50% of the period were randomly assigned (1:1) to flash sensor-based glucose monitoring (intervention group) or to self-monitoring of blood glucose with capillary strips (control group). Randomisation was done centrally using the biased-coin minimisation method dependent on study centre and type of insulin administration. Participants, investigators, and study staff were not masked to group allocation. The primary outcome was change in time in hypoglycaemia ( Findings Between Sept 4, 2014, and Feb 12, 2015, we enrolled 328 participants. After the screening and baseline phase, 120 participants were randomly assigned to the intervention group and 121 to the control group, with outcomes being evaluated in 119 and 120, respectively. Mean time in hypoglycaemia changed f…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The clinical efficacy of CGM has been demonstrated in numerous retrospective studies and RCTs of individuals with T1D regardless of insulin delivery method.156–161”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [161]
In the citing paper
“Numerous studies have demonstrated significant clinical benefits of CGM use in people with diabetes regardless of insulin delivery method (1-15).”
From Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range (2019) · cites this paper as [8]
In the citing paper
“One RCT showed less time in the hypoglycemic range, without significant change in HbA 1c (163).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [163]
In the citing paper
“One study was performed in adults with type 1 diabetes and met its primary outcome of a reduction in rates of hypoglycemia (68).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [68]
In the citing paper
“Real-time CGM studies can be divided into studies with elevated A1C with the primary end point of A1C reduction and studies with A1C near target with the primary end point of reduction in hypoglycemia (98, 109-124).”
From 6. Glycemic Targets: Standards of Care in Diabetes—2023 (2023) · cites this paper as [113]
Citations
Cites
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
Assessing Psychosocial Distress in Diabetes
Polonsky, W. H., Fisher, L., Earles, J., Dudl, R. J., Lees, J., Mullan, J., & Jackson, R. A. (2005) · Diabetes Care · doi:10.2337/diacare.28.3.626 · Cited by 1,575
Defining and Reporting Hypoglycemia in Diabetes
American Diabetes Association Workgroup on Hypoglycemia (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1245 · Cited by 1,146
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894
Risk of hypoglycaemia in types 1 and 2 diabetes: Effects of treatment modalities and their duration
UK Hypoglycaemia Study Group (2007) · Diabetologia · doi:10.1007/s00125-007-0599-y · Cited by 825
Epidemiology of severe hypoglycemia in the diabetes control and complications trial
(1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)80085-z · Cited by 807
Epidemiology of severe hypoglycemia in the Diabetes Control and Complications Trial
(1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)90605-w · Cited by 807
Continuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities
Rodbard, D. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0417 · Cited by 737
Threshold-based insulin-pump interruption for reduction of hypoglycemia
Bergenstal, R. M., Klonoff, D. C., Garg, S. K., Bode, B. W., Meredith, M., Slover, R. H., Ahmann, A. J., Welsh, J. B., Lee, S. W., & Kaufman, F. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1303576 · Cited by 652
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
Research works printed but not linked: 1
- 1997, Hypoglycaemia in the diabetes, control and complications trial, Diabetes, 46, 272
Cited by
Items 801–891 of 891
Placement of insulin pump by telemedicine
Foglia, A. (2020) · The Journal of AMD · doi:10.36171/jamd20.23.4.6
Zhang, W., Liu, Y., Sun, B., Shen, Y., Li, M., Peng, L., Duan, H., Su, X., Lu, S., Tian, X., et al. (2021) · Research Square · doi:10.21203/rs.3.rs-657144/v1
Bio-gas analysis for diagnosis of diseases
Kondo, T., Okumura, N., & Shimouchi, A. (2017) · Journal of Japan Association on Odor Environment · doi:10.2171/jao.48.402
Living with type 1 diabetes: what really matters?
Wilmot, E. G. (2021) · Practical Diabetes · doi:10.1002/pdi.2352
Gallardo, C. (2010) · Razón y fe: Revista hispanoamericana de cultura
Diabetes in childhood and adolescence
Bilous, F. R., Donnelly, R., & DM, F. I. I. (2021) · Wiley eBooks · doi:10.1002/9781118976074.ch30
Glucose flash monitoring systems: sources of funding, procurement and delivering to patients
Федоров, А. А., Сергеевна, П. О., & Ratushnyak, S. S. (2021) · Medical Technologies Assessment and Choice · doi:10.17116/medtech20214304144
Clinical and economic benefits of continuous blood glucose monitoring devices
Rahman, R. S., Salamah, H. E., Alshair, F. M., Alsawadi, A. A., Alghamdi, O. M., Alalasi, A. B., Mufarrihi, A. M., Alalawi, A. O., Alzahrani, O. M., Alanazi, H. O., et al. (2022) · International Journal of Community Medicine and Public Health · doi:10.18203/2394-6040.ijcmph20220053
Glucose Monitoring and Sensing
Pickup, J. C., & Oliver, N. S. (2022) · doi:10.1093/med/9780198870197.003.0251 · Cited by 1
Chow, E., & Heller, S. R. (2022) · Springer eBooks · doi:10.1007/978-3-030-90684-9_35 · Cited by 1
Hypoglycemia Detection in Diabetes
Richardson, J. M., & Shaginian, R. M. (2022) · IntechOpen eBooks · doi:10.5772/intechopen.103137
Brown, R. N. (2019) · Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature · doi:10.3410/f.735483240.793559258
1) Progression of the Advanced Technology and Therapy for Diabetes Mellitus
Matsuhisa, M., & Kuroda, A. (2021) · Nihon Naika Gakkai Zasshi · doi:10.2169/naika.110.420
Benmayouf, T., Villoing, B., & Doumenc, B. (2019) · EMC - Urgenze · doi:10.1016/s1286-9341(19)42035-8
Filho, I. D. M. B., de Aquino, G. S., & de Lima, M. A. (2018) · IGI Global eBooks · doi:10.4018/978-1-5225-6198-9.ch007
Flash-Glukose-Monitoring senkt Hypoglykämierisiko
Heidelberg, S.-V. B. (2017) · CME · doi:10.1007/s11298-017-6036-8
Clinical applications of wearable and non-contact sensors
俊世, 田. (2020) · JAPANES JOURNAL OF MEDICAL INSTRUMENTATION · doi:10.4286/jjmi.90.11 · Cited by 2
Mateu-Salat, M., Moreno-Fernández, J., Mangas, N., Genua, I., Martínez, M. J., López, A., González, C., & Chico, A. I. (2022) · Endocrinología Diabetes y Nutrición (English ed ) · doi:10.1016/j.endien.2022.03.007 · Cited by 1
Suganuma, Y., Takahashi, H., & Nishimura, R. (2022) · Diabetology International · doi:10.1007/s13340-022-00585-y
A folyamatos glükózmonitorozás jelentősége a korszerű diabetesgondozásban
Kocsis, G. (2022) · Lege Artis Medicinae · doi:10.33616/lam.32.016
Borot, S. (2022) · Biologie Aujourd hui · doi:10.1051/jbio/2022005
Tateishi, K., Saito, Y., Yamazaki, T., Kitahara, H., & Kobayashi, Y. (2022) · Diabetes Epidemiology and Management · doi:10.1016/j.deman.2022.100104
Type 1 Diabetes in Pregnancy: A Review
Pangkahila, E. S., & Setiawan, W. A. (2022) · European Journal of Medical and Health Sciences · doi:10.24018/ejmed.2022.4.4.1427 · Cited by 2
Nouvelle technologie de gestion du diabète: apprendre ensemble et en situation
Pralong, M., Danesi, G., Panese, F., Burnand, B., Hauschild, M., & Grossen, M. (2022) · JMIG · doi:10.53738/revmed.2022.18.796.1767
„Time in range“ (TIR) vs. Glykohämoglobin Typ A1c (HbA1c): was zählt für unsere Patienten?
Harer, C., & Mader, J. K. (2022) · Die Diabetologie · doi:10.1007/s11428-022-00963-9
Muhs, A., Bobrowski, T., Lielpētere, A., & Schuhmann, W. W. (2022) · Angewandte Chemie · doi:10.1002/ange.202211559
Guía y recomendaciones para el uso del sistema flash de monitoreo continuo de glucosa (iMCG)
Navarro‐Lara, A., Yepez-Rodríguez, A. E., Antillón-Ferreira, C., Ramos, D. C., Martínez-Abundis, E., Lavalle-González, F. J., Canto, J. A. C., Barrientos-Pérez, M., Vidrio-Velázquez, M., Escalante-Pulido, M., et al. (2022) · Revista Mexicana de Endocrinología Metabolismo y Nutrición · doi:10.24875/rme.21000028
Il monitoraggio in continuo della glicemia: stato dell’arte
Irace, C., & Molfetta, S. D. (2022) · il Diabete · doi:10.30682/ildia2204g · Cited by 1
flash glucose monitoring revolution: the Sat Nav journey
Wilmot, E. G. (2022) · British Journal of Diabetes · doi:10.15277/bjd.2022.372
Palacios, A., Cairoli, F. R., Balan, D. J., Balmaceda, C., Augustovski, F., Pichón-Rivière, A., & Bardach, A. (2023) · Expert Review of Pharmacoeconomics & Outcomes Research · doi:10.1080/14737167.2023.2171989 · Cited by 1
Stojanović, M., Pešić, M., Ilić, S., Deljanin-Ilić, M., & Ćirić, V. M. (2022) · AFMN Biomedicine · doi:10.5937/afmnai40-37498
Continuous Glucose Monitoring-Assisted Insulin Dose Titration in the Indian Outpatient Setting
Ganti, S. R., & Gurazada, K. C. (2022) · International Journal of Diabetes and Technology · doi:10.4103/ijdt.ijdt_16_22
Jacobsen, L. M., Sherr, J. L., Considine, E. G., Chen, A., Peeling, S., Hulsmans, M., Charleer, S., Urazbayeva, M., Tosur, M., ALAMARIE, S. A., et al. (2023) · medRxiv · doi:10.1101/2023.04.15.23288624
Saxena, R. K., Singh, A. B., & .Singh, N. P. (2023) · International Journal of Life Science and Pharma Research · doi:10.22376/ijlpr.2023.13.4.sp6.l87-l99
Clinical Application of Technology: Why Are they Needed, How to Implement, and What Challenges
Kudelka, J., & Maetzler, W. (2023) · Practical issues in geriatrics · doi:10.1007/978-3-031-32246-4_2
Importance of continuous glucose monitoring in the treatment of diabetes mellitus
Moon, S. J., & Lee, W. (2023) · Journal of Korean Medical Association · doi:10.5124/jkma.2023.66.7.432
Interstitial glucose monitoring in people with diabetes
Casado-Hoces, S. V., Inglada-Infante, P., Algora-Donoso, I., & González-Tejedor, D. (2023) · Revista Española de Sanidad Penitenciaria · doi:10.18176/resp.00071 · Cited by 1
Schwere Hypoglykämie und diabetische Ketoazidose: Warnung erwünscht
Thomas, A. (2023) · Info Diabetologie · doi:10.1007/s15034-023-4545-y
Yamada, E., Nakajima, Y., Horiguchi, K., Okada, S., & Yamada, M. (2023) · Endocrine Journal · doi:10.1507/endocrj.ej23-0125
Infodemiologia sobre protocolos de automonitoramento da glicemia capilar na internet brasileira
Garcia, R. A. C., Machado, M. E., Lima, R. A. D., Medina, L. A. C., Veras, V. S., de Azevedo, L. D., & Teixeira, C. R. D. S. (2023) · O Mundo da Saúde · doi:10.15343/0104-7809.202347e15212023p
Infodemiology on capillary blood glucose self-monitoring protocols on the Brazilian internet
Garcia, R. A. C., Machado, M. E., Lima, R. A. D., Medina, L. A. C., Veras, V. S., de Azevedo, L. D., & Teixeira, C. R. D. S. (2023) · O Mundo da Saúde · doi:10.15343/0104-7809.202347e15212023i
New Technologies for Glucose Monitoring
Danne, T., & Kordonouri, O. (2024) · Wiley eBooks · doi:10.1002/9781119697473.ch32
Positioning “Time-in-Range” in the Treatment of Diabetes in India
Mohan, V., Unnikrishnan, A. G., Kesavadev, J., & Saboo, B. (2022) · International Journal of Diabetes and Technology · doi:10.4103/ijdt.ijdt_2_22
Zhang, D., Yang, Y., Zhang, J., Chen, J., Huang, L., Zhang, L., & Liu, X. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4791181
Mesure continue du glucose : quels sont les nouveaux indicateurs de suivi ?
Joubert, M. (2024) · Médecine des Maladies Métaboliques · doi:10.1016/j.mmm.2024.05.001 · Cited by 1
Lameijer, A. (2024) · University of Groningen research database (University of Groningen / Centre for Information Technology) · doi:10.33612/diss.1021051970
Japanese candlestick charts for diabetes
Boj-Carceller, D. (2024) · World Journal of Methodology · doi:10.5662/wjm.v14.i2.90708
McDonnell, D. J., Smith, D., & Forde, H. E. (2024) · Diabetic Medicine · doi:10.1111/dme.15391
Pérez-López, P. (2024) · UVaDOC UVaDOC University of Valladolid Documentary Repository (University of Valladolid) · doi:10.35376/10324/68548
Qamar, T., Awasthi, S., & Bhriguvanshi, A. (2024) · Journal of the Scientific Society · doi:10.4103/jss.jss_337_23
Abucevicz-Swick, K. (2024) · The Research Repository @ WVU (West Virginia University) · doi:10.33915/etd.12543 · Cited by 1
Tecnología aplicada a la diabetes
Cebada, A. B., Silva, J. B. Q., Escobar-Morreale, H. F., & Chávez, L. N. (2024) · Medicine - Programa de Formación Médica Continuada Acreditado · doi:10.1016/j.med.2024.10.004
Sakane, N., Matsuhisa, M., Kuroda, A., Miura, J., Hirota, Y., Kato, K., Toyoda, M., Kouyama, R., Kouyama, K., Shimada, A., et al. (2024) · Diabetology International · doi:10.1007/s13340-024-00762-1
Impacto del inicio de la monitorización flash de glucosa en pacientes adultos con diabetes tipo 1
Sahagún, R. J. (2024) · UVaDOC UVaDOC University of Valladolid Documentary Repository (University of Valladolid) · doi:10.35376/10324/72390
Koseki, Y., Kamiya, S., Terashima, M., Furukawa, K., Fujiya, K., Tanizawa, Y., & Bando, E. (2025) · Journal of Gastrointestinal Surgery · doi:10.1016/j.gassur.2025.102049
Innovaciones tecnológicas y diabetes
Lablanche, S., Delagenière, J., & Jalbert, M. (2025) · EMC - Tratado de Medicina · doi:10.1016/s1636-5410(25)50386-0
Glucose meters and sensors for type 1 diabetes (part 2)
Slee, P. H. T. J., Helmerhorst, F. M., & Nieuwhof, M. (2023) · Geneesmiddelenbulletin · doi:10.35351/gebu.2023.6.10 · Cited by 2
Xing, H., Hu, M., Jiang, Y., Li, X.-H., Zhu, B., & Wang, Z. (2025) · World Journal of Gastrointestinal Surgery · doi:10.4240/wjgs.v17.i6.105514
“CGM provides detailed information on the 24-hour glycemic profile, including nocturnal and postprandial glycemia, which standard finger-prick blood glucose monitoring cannot provide[40].”
Shestakova, M. V., Peterkova, V. A., Galstyan, G. R., Ibragimova, L. I., Klimontov, V. V., Лаптев, Д. Н., Malaya, I. P., & Shestakova, E. A. (2025) · Diabetes Mellitus · doi:10.14341/dm13329
Nigam, P., VERMA, A., & DUTTA, S. (2025) · Innovare Journal of Medical Sciences · doi:10.22159/ijms.2025v13i4.55051
Case Studies From India: Management of Diabetes Using Continuous Glucose Monitoring
Gupta, A. K., Krishnan, A. S., Kataria, M., & Jain, N. (2025) · Cureus · doi:10.7759/cureus.93177 · Cited by 2
Dervişoğlu, M., Günbaş, M., & Besen, D. B. (2025) · The Science of Diabetes Self-Management and Care · doi:10.1177/26350106251371082
Corbal, B. S., Puzic, R. F. D. S., da Silva, É. T., Lameirinhas, T. S., da Silva, C. M. B., & Corbal, G. S. O. (2025) · Medicine · doi:10.1097/md.0000000000045015 · Cited by 2
Insulins, Technologies, and Telemedicine
Cipponeri, E., Vitale, L., Milani, I., & Caruso, R. (2025) · Springer eBooks · doi:10.1007/978-3-032-01700-0_16
Continuous Glucose Monitoring: A Practical Overview for Primary Care Providers in Canada
Shin, S., & Gilbert, J. D. (2025) · Canadian Primary Care Today · doi:10.58931/cpct.2025.3349
村川, 正. (2025) · The Japanese Journal of SURGICAL METABOLISM and NUTRITION · doi:10.11638/jssmn.59.5_127
de Pouvourville, G., Timmons, J., Levrat‐Guillen, F., Zara, A. T., & Poon, Y. (2025) · Cost Effectiveness and Resource Allocation · doi:10.1186/s12962-025-00673-1
Ruíz, M. P., Jiménez, B. R., Gómez, P. R. D. V., Robles, N. L., Ortega, R. P., Sánchez-Laguna, F. J., Cruz, I. V., Sánchez, E. M., Sánchez-Álvarez, M., Fernandez-Delgado, C., et al. (2025) · Endocrinología Diabetes y Nutrición · doi:10.1016/j.endinu.2025.501661 · Cited by 2
Wang, R., Kyi, M., Krishnamoorthi, B., Connell, A., Chiang, C. Y., Renouf, D., Barmanray, R., & Fourlanos, S. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251395088 · Cited by 1
Kong, Y. W., Yuan, C. Y., Kiburg, K., Brown, K., Trawley, S. L., Partovi, A., ROEM, K. L., Harrison, N., Fourlanos, S., Ekinci, E. I., et al. (2023) · Figshare · doi:10.6084/m9.figshare.24277196
Eer, A., Ho, R. C. Y., Hearn, T., Hachem, M., Freund, M., Burchill, L. J., Atkinson‐Briggs, S., Singh, S., Eades, S., O’Brien, R. C., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26651241
Nowacka, K., Grygorowicz, A., Baran, K., Ględa, M., Szyszka, M., Radecka, W., Kozak, W., Szreiber, A., Grela, K., Jabłoński, K., et al. (2025) · International Journal of Innovative Technologies in Social Science · doi:10.31435/ijitss.4(48).2025.4660
Arakawa, D., Ishisaka, M., Arimura, Y., Nakai, M., & Yoshimura, M. (2026) · Cureus · doi:10.7759/cureus.103437
“CGM was performed using the FreeStyle Libre system (first-generation FreeStyle Libre, Abbott Diabetes Care, Alameda, CA, USA; approval number 22800BZX00212000) [18,19], which continuously measures subcutaneous interstitial glucose levels for 14 days using a sensor implanted in the upper arm.”
Consensus on Applications and Emerging Needs for Continuous Glucose Monitoring in Portugal
Neves, J. S., Teixeira, S., Neves, Â. S., Sampaio, L., Reis, M., Paiva, S., Mirante, A., Freitas, P., Nortadas, R., Melo, M., et al. (2026) · Endocrinology Insights · doi:10.1159/000551692
Hayashi, S., Konaka, K., & HAMADA, R. (2026) · Cureus · doi:10.7759/cureus.107766
Kosimov, O. U., Kurnikova, I., Kokorin, K. V. A., Zavalina, M., Pavlov, A. F., & Morgunov, L. Y. (2026) · Medical alphabet · doi:10.33667/2078-5631-2026-11-23-29
Terbosh, M., Dubaj, M., Ignarska, J., Judzińska, A., `Mzabi, S. K., Kwolek, M., Osipowska, J., Piech, B., Sobczyńska, K., & Trojanowska, E. (2026) · International Journal of Innovative Technologies in Social Science · doi:10.31435/ijitss.2(50).2026.5614
Sanke, T., Matsuoka, Y., Yamada, S., & Kadoya, Y. (2026) · Diabetology · doi:10.3390/diabetology7070123
Valgaerts, L., Meulemeester, J. D., Visser, M. M., Charleer, S., Fieuws, S., Keymeulen, B., Block, C. E. M. D., Mathieu, C., Casteels, K., & Gillard, P. (2026) · Diabetes Care · doi:10.2337/dc26-0763 · Cited by 1
Olamoyegun, M., Olamoyegun, O. D., Akinlade, A. T., Saliu, O. O., & Adeyemi, T. A. (2026) · Cardiovascular Diabetology – Endocrinology Reports · doi:10.1186/s40842-026-00310-7 · Cited by 1
Widera, M., Owczarek, A. J., Kolonko, A., Kamińska, D., Świder, R., Król, R., Sekta, S., Więcek, A., & Ziaja, J. (2026) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfag168
Glucose Monitoring: Advances in Technology
McDonnell, D. J., Smith, D., & Forde, H. E. (2026) · Springer eBooks · doi:10.1007/978-3-032-24854-1_4
Kaczmarski, M., Kamiński, P., Surdacka, L., Jagiełło, J. K., Jakubas, A., Iwanicka, K. A., Pawelec, K., & Jóźwiak, S. M. (2026) · International Journal of Innovative Technologies in Social Science · doi:10.31435/ijitss.2(50).2026.5663
Qosimova, S. J. (2026) · Health care of Tajikistan · doi:10.52888/0514-2515-2026-370-3-178-187
Kesavadev, J., Makkar, B. M., Joshi, S., Unnikrishnan, A., Gupta, A., Chawla, M. S., Saboo, B., Deshpande, N., & Bhograj, A. (2026) · International Journal of Diabetes in Developing Countries · doi:10.1007/s13410-026-01737-5
(2026) · ADA Clinical Compendia · doi:10.2337/db20261-33
Feng, X., Zhou, J., Wang, X., & Wang, B. (2026) · ACS Sensors · doi:10.1021/acssensors.6c03404
Gupta, M., Dey, A. K., Goklani, R., MODI, R., & Saraogi, H. (2026) · International Journal of Diabetes and Technology · doi:10.4103/ijdt.ijdt_31_26
Metadata
- Authors
- Bolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R.
- Affiliations
- Karolinska University Hospital (SE)
- Medisch Centrum Haaglanden (NL)
- Paracelsus Medical University (AT)
- Corresponding author
- Bolinder, Jan
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2016-11
- Volume
- 388
- Issue
- 10057
- Pages
- 2254-2263
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2519526531
- Semantic Scholar
- b7578dcd738c57d556845ed4e8c554c14d7d0830
- Cited by
- 893
- References
- 35
- Citations by year
- 2026: 20 · 2025: 55 · 2024: 68 · 2023: 92 · 2022: 121 · 2021: 133 · 2020: 124 · 2019: 113 · 2018: 92 · 2017: 63 · 2016: 10
- FWCI
- 93.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Abbott Diabetes Care
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- type 1 diabetes, hypoglycemia, flash glucose monitoring, continuous glucose monitoring, self-monitoring of blood glucose, HbA1c, insulin dose adjustment, glycated albumin
- MeSH terms
- Blood Glucose, Diabetes Mellitus, Type 1, Drug Administration Schedule, Glycated Hemoglobin, Humans, Hypoglycemia, Hypoglycemic Agents, Insulin, Monitoring, Physiologic, Inventions
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.