The DOI matches its Crossref record; 11 of the 12 references it cites were found in a registry or an index.
Effect of surface treatments on the frosting/defrosting behavior of a fin-tube heat exchanger
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, most heat exchangers used in industrial and domestic refrigerators have been developed experimentally [18-20].”
From Fin spacing optimization of a fin-tube heat exchanger under frosting conditions (2006) · cites this paper as [18]
Citations
Cites
(1953) · Mechanical Engineering · Cited by 6,608
Contact angle temperature dependence for water droplets on practical aluminum surfaces
Bernardin, J. D., Mudawar, I., Walsh, C. B., & Franses, E. I. (1997) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(96)00184-6 · Cited by 296
Heat and mass transfer for plate fin-and-tube heat exchangers, with and without hydrophilic coating
Wang, C.-C., & Chang, C. T. (1998) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(98)00060-x · Cited by 138
Okoroafor, E. U., & Newborough, M. (2000) · Applied Thermal Engineering · doi:10.1016/s1359-4311(99)00056-3 · Cited by 76
Incipient Phenomena of Frost Formation
Seki, N., FUKUSAKO, S., MATSUO, K., & UEMURA, S. (1984) · Bulletin of JSME · doi:10.1299/jsme1958.27.2476 · Cited by 33
Lee, K.-S., & Kim, W.-S. (1999) · KSME International Journal · doi:10.1007/bf03184764 · Cited by 26
Self-citationIncipient Phenomena of Frost Formation
Seki, N., FUKUSAKO, S., MATSUO, K., & UEMURA, S. (1984) · TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B · doi:10.1299/kikaib.50.825 · Cited by 16
難着霜熱交換器 (建築エレクトロニクス-2-ビジネス・産業,リゾ-ト・アミュ-ズメント環境 )
津田, 善., & 岩本, 明. (1992) · National technical report · Cited by 8
Effects of Hydrophobic Surface Treatments on Dropwise Condensation and Freezing of Water
Bryant, J. A. (1995) · OakTrust (Texas A&M University Libraries) · Cited by 7
O’Neal, D. L., Bryant, J. A., & Parker, B. D. (1998) · Nihon dennetsu gakkai ronbunshu/Thermal science and engineering · Cited by 4
Research works printed but not linked: 2
- Tsuda, 1992, Anti-frosting heat exchanger, National Technical Report, 38, 108
- Tao Y-X, et al. Frost growth characteristics on heat exchanger surfaces: measurement and simulation studies, HTD-Vol. 286, Fundamentals of Phase Change: Sublimation and Solidification, ASME, 1994.
Cited by
Sorted by citations
Zhang, P., & Lv, F. Y. (2015) · Energy · doi:10.1016/j.energy.2015.01.061 · Cited by 418
Review on improvement for air source heat pump units during frosting and defrosting
Song, M., Deng, S., Dang, C., Mao, N., & Wang, Z. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.12.022 · Cited by 384
Heat transfer enhancement in fin-and-tube heat exchangers – A review on different mechanisms
Sadeghianjahromi, A., & Wang, C.-C. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.110470 · Cited by 240
Chen, X.-M., Ma, R., Zhou, H., Zhou, X.-F., Che, L., Yao, S.-H., & Wang, Z.-K. (2013) · Scientific Reports · doi:10.1038/srep02515 · Cited by 225
Amer, M., & Wang, C.-C. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.01.120 · Cited by 218
Frosting characteristics on hydrophobic and superhydrophobic surfaces: A review
Kim, M.-H., Kim, H., Lee, K.-S., & Kim, D. R. (2017) · Energy Conversion and Management · doi:10.1016/j.enconman.2017.01.067 · Cited by 171
Self-citationNguyen, D. H., & Ahn, H. S. (2021) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2021.121601 · Cited by 160
Research of anti-frosting technology in refrigeration and air conditioning fields: A review
Feng, W., Liang, C.-H., & Zhang, X. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.08.046 · Cited by 142
Qu, M., Liang, X., Deng, S., & Yiqiang, J. (2010) · Building and Environment · doi:10.1016/j.buildenv.2010.04.006 · Cited by 132
Qu, M., Xia, L., Deng, S., & Jiang, Y. (2012) · Applied Energy · doi:10.1016/j.apenergy.2011.08.034 · Cited by 129
Experimental study of frost accumulation on fan-supplied tube-fin evaporators
da Silva, D. L., Hermes, C. J. L., & Melo, C. (2011) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2010.11.006 · Cited by 118
Huang, D., Li, Q., & Yuan, X. (2009) · Applied Energy · doi:10.1016/j.apenergy.2008.11.023 · Cited by 118
Song, M., Dang, C., Higashi, T., & Hihara, E. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110103 · Cited by 91
Frosting and defrosting characteristics of a fin according to surface contact angle
Kim, K., & Lee, K.-S. (2011) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2011.02.065 · Cited by 108
Self-citationKwak, K., & Bai, C. (2010) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2009.10.016 · Cited by 101
Huang, D., Ri-Jing, Z., Liu, Y., & Yi, D.-B. (2014) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2013.11.052 · Cited by 99
Condensation frosting on meter-scale superhydrophobic and superhydrophilic heat exchangers
Boyina, K., Mahvi, A., Chavan, S., Park, D., Kumar, K., Lira, M., Yu, Y., Gunay, A., Wang, X.-F., & Miljković, N. (2019) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2019.118694 · Cited by 86
The application of photo-coupler for frost detecting in an air-source heat pump
Byun, J.-S., Jeon, C.-D., Jung, J.-H., & Lee, J. (2005) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2005.06.008 · Cited by 99
Modeling for predicting frosting behavior of a fin–tube heat exchanger
Yang, D.-K., Lee, K.-S., & Song, S. (2006) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2005.09.022 · Cited by 94
Self-citationQu, M., Xia, L., Deng, S., & Jiang, Y. (2011) · Applied Energy · doi:10.1016/j.apenergy.2011.11.057 · Cited by 94
Song, M., Mao, N., Xu, Y.-J., & Deng, S. (2019) · Thermal Science and Engineering Progress · doi:10.1016/j.tsep.2019.03.002 · Cited by 85
Mahvi, A. J., Boyina, K., Musser, A., Elbel, S., & Miljkovic, N. (2021) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2021.121162 · Cited by 92
Moallem, E., Cremaschi, L., Fisher, D. E., & Padhmanabhan, S. (2012) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2012.01.022 · Cited by 91
Kim, K., & Lee, K.-S. (2013) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2013.01.036 · Cited by 89
Self-citationPatil, M. S., Seo, J.-H., & Lee, M.-Y. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.11.107 · Cited by 86
Fin spacing optimization of a fin-tube heat exchanger under frosting conditions
Yang, D.-K., Lee, K.-S., & Song, S. (2006) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2006.01.016 · Cited by 81
Self-citationEnergy transfer procession in an air source heat pump unit during defrosting
Song, M., Xu, X.-G., Mao, N., Deng, S., & Xu, Y.-J. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.07.063 · Cited by 77
Determination method of defrosting start-time based on temperature measurements
Kim, M.-H., & Lee, K.-S. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.02.071 · Cited by 79
Self-citationDrainage of frost melt water from vertical brass surfaces with parallel microgrooves
Rahman, M. A., & Jacobi, A. M. (2011) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2011.11.015 · Cited by 77
Review of nature-inspired heat exchanger technology
Huang, Z., Hwang, Y., & Radermacher, R. (2017) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2017.03.006 · Cited by 77
First-principles modeling of frost accumulation on fan-supplied tube-fin evaporators
da Silva, D. L., Hermes, C. J. L., & Melo, C. (2011) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2011.04.029 · Cited by 70
A new method for preventing air-source heat pump water heaters from frosting
Zhang, L., Fujinawa, T., & Saikawa, M. (2012) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2012.04.004 · Cited by 70
Kim, M.-H., Kim, H., Kim, D. R., & Lee, K.-S. (2016) · Energy Conversion and Management · doi:10.1016/j.enconman.2015.11.028 · Cited by 68
Self-citationKim, K., Kim, M.-H., Kim, D. R., & Lee, K.-S. (2014) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2013.12.060 · Cited by 64
Self-citationLi, D., & Chen, Z. (2013) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2013.10.005 · Cited by 63
Experimental study on frosting/defrosting characteristics of microgrooved metal surfaces
Rahman, M. A., & Jacobi, A. M. (2014) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2014.11.002 · Cited by 62
Wang, F., Zhou, Y., Yang, W., Ni, M., Zhang, X., & Liang, C. (2020) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2020.114967 · Cited by 60
Li, L. T., Wang, W., Sun, Y. Y., Feng, Y. C., Lu, W. P., Zhu, J. H., & Ge, Y. J. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.07.028 · Cited by 58
Kim, K., & Lee, K.-S. (2012) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2012.06.076 · Cited by 56
Self-citationGanesan, P., Vanaki, S., Thoo, K. K., & Chin, W.-M. (2016) · International Communications in Heat and Mass Transfer · doi:10.1016/j.icheatmasstransfer.2016.02.017 · Cited by 55
Zheng, H., Chang, S., Ma, G., & Wang, S. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110175 · Cited by 52
Song, M., Fan, C., Mao, N., & Xu, Y. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.08.027 · Cited by 51
Rahman, M., & Jacobi, A. (2014) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2013.11.062 · Cited by 51
Experimental study of the effects of fin surface characteristics on defrosting behavior
Liang, C., Wang, F., Lü, Y., Wu, C., Zhang, X., & Zhang, Y. (2015) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2014.09.082 · Cited by 49
Wu, X., Chu, F., Ma, Q., & Zhu, B. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.03.011 · Cited by 48
Huang, D., Yuan, X., & Zhang, X. (2004) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2004.04.010 · Cited by 47
Kim, K., Kim, D. R., & Lee, K.-S. (2013) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2013.05.027 · Cited by 46
Self-citationExperimental investigation of frost retardation for superhydrophobic surface using a luminance meter
Kim, D., Kim, H., Kim, S. W., Kim, D. R., & Lee, K.-S. (2015) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2015.04.042 · Cited by 46
Self-citationDefrosting performance of superhydrophobic fin-tube heat exchanger
Feng, W., Liang, C.-H., Zhang, Y., & Zhang, X. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.11.028 · Cited by 47
Optimization design and experimental study of thermoelectric dehumidifier
Yu, Y., Sun, Y., Sun, D., Sang, C. C., Sun, M., Shen, L., & Chen, H. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.05.172 · Cited by 46
A study of frost build-up on hydrophilic and hydrophobic surfaces under forced convection conditions
Hermes, C. J. L., Nascimento, V. S., Loyola, F. R., Cardoso, R. P., & Sommers, A. D. (2019) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2018.08.009 · Cited by 44
Klingebiel, J., Hassan, M., Venzik, V., Vering, C., & Müller, D. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.121072 · Cited by 37
Li, D., Qian, C.-L., Gao, S.-W., Zhao, X.-B., & Zhou, Y.-M. (2017) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2017.04.022 · Cited by 36
Li, K., Xia, D., Luo, S., Zhao, Y., Tu, R., Zhou, X., Zhang, H., & Su, L. (2022) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2021.117766 · Cited by 40
Dynamic characteristics of an air-to-water heat pump under frosting/defrosting conditions
Huang, D., He, Z., & Yuan, X. L. (2006) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2006.12.003 · Cited by 39
Chung, Y., Na, S., Choi, J., & Kim, M. S. (2019) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2019.04.002 · Cited by 36
Opportunities in Nano-Engineered Surface Designs for Enhanced Condensation Heat and Mass Transfer
Ho, J. Y., Rabbi, K. F., Khodakarami, S., Ma, J., Boyina, K. S., & Miljkovic, N. (2022) · ASME Journal of Heat and Mass Transfer · doi:10.1115/1.4053454 · Cited by 39
Effects of aluminium surface morphology and chemical modification on wettability
Rahimi, M., Fojan, P., Gurevich, L., & Afshari, A. (2014) · Applied Surface Science · doi:10.1016/j.apsusc.2014.01.059 · Cited by 39
Chung, Y., Na, S.-I., Yoo, J. W., & Kim, M. S. (2021) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2020.116405 · Cited by 38
Aluminum surface wettability changes by pool boiling of nanofluids
Zhang, F., & Jacobi, A. M. (2016) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2016.07.026 · Cited by 37
Kaneko, S., Urata, C., Sato, T., Hönes, R., & Hozumi, A. (2019) · Langmuir · doi:10.1021/acs.langmuir.9b00206 · Cited by 24
Experimental studies on hot gas bypass defrosting control strategies for air source heat pumps
Xi, Z., Yao, R., Li, J.-B., Du, C.-Q., Yu, Z.-X., & Li, B.-Z. (2021) · Journal of Building Engineering · doi:10.1016/j.jobe.2021.103165 · Cited by 41
Adaptive defrost methods for improving defrosting efficiency of household refrigerator
Yoon, Y., Jeong, H., & Lee, K.-S. (2018) · Energy Conversion and Management · doi:10.1016/j.enconman.2017.12.039 · Cited by 33
Self-citationDong, J., Jiang, Y., Yao, Y., & Zhang, X. (2011) · Journal of Central South University of Technology · doi:10.1007/s11771-011-0958-1 · Cited by 33
Rahman, M. A., & Jacobi, A. M. (2013) · Heat Transfer Engineering · doi:10.1080/01457632.2013.776453 · Cited by 32
Liang, C.-H., Feng, W., Lu, Y., Yang, M.-T., & Zhang, X. (2016) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2015.10.015 · Cited by 33
An experimental study of defrost on treated surfaces: Effect of frost slumping
Liu, Y., & Kulacki, F. A. (2018) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2017.12.018 · Cited by 31
Wang, F., Liang, C., Yang, W., & Zhang, X. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110134 · Cited by 30
A Critical Literature Review of Defrost Technologies for Heat Pumps and Refrigeration Systems
Nawaz, K., Elatar, A., & Fricke, B. A. (2018) · doi:10.2172/1474464 · Cited by 31
Oh, J. K., Liu, S., Jones, M., Yegin, Y., Hao, L., Tolen, T. N., Nagabandi, N., Scholar, E. A., Castillo, A., Taylor, T. M., et al. (2018) · Food Control · doi:10.1016/j.foodcont.2018.10.005 · Cited by 30
Evaporator Frosting in Refrigerating Appliances: Fundamentals and Applications
Hermes, C. J. L., Boeng, J., Silva, D. L. D., Knabben, F. T., & Sommers, A. D. (2021) · Energies · doi:10.3390/en14185991 · Cited by 31
Feng, W., Liang, C.-H., & Zhang, X. (2016) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2016.01.008 · Cited by 27
Defrosting behavior and performance on vertical plate for surfaces of varying wettability
Kim, H., Jin, G., Jeon, J., Lee, K.-S., & Kim, D. R. (2018) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2017.12.054 · Cited by 25
Self-citationMa, L., Wang, F., Wang, Z., Zhang, S., Liu, Z., & Lou, Y. (2021) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2021.11.025 · Cited by 26
Effect of Airborne Hydrocarbons on the Wettability of Phase Change Nanoparticle Decorated Surfaces
Guo, W., Chen, B., Do, V. L., ten Brink, G. H., Kooi, B. J., Svetovoy, V. B., & Palasantzas, G. (2019) · ACS Nano · doi:10.1021/acsnano.9b06909 · Cited by 25
Image processing for frost thickness measurement in fin-and-tube heat exchangers
Lee, W.-J., & Kyung Kwon, O. (2021) · Thermal Science and Engineering Progress · doi:10.1016/j.tsep.2021.100937 · Cited by 25
Effect of heat transfer area distribution on frosting performance of refrigerator evaporator
Pegallapati, A. S., & Ramgopal, M. (2021) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2021.121317 · Cited by 26
Frost behavior on a fin considering the heat conduction of heat exchanger fins
Kim, J.-S., Lee, K.-S., & Yook, S.-J. (2009) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2008.12.023 · Cited by 25
Self-citationPark, J.-S., Kim, J., & Lee, K.-S. (2017) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2017.01.043 · Cited by 24
Self-citationFlat tube heat exchangers: Experimental analysis of frosting and water retention
Westhaeuser, J., Brauchle, L., Albrecht, J.-C., Tegethoff, W., Lemke, N., & Koehler, J. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2022.119319 · Cited by 24
Udovichenko, A., & Zhong, L. (2020) · Science and Technology for the Built Environment · doi:10.1080/23744731.2020.1787083 · Cited by 23
Ye, Z., Shi, J., & Chen, J. (2021) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2021.117066 · Cited by 23
Experimental investigation on anti-condensation characteristic of desiccant coated metal cabinet
Ge, T., Hao, R.-Y., Dai, Y.-J., Wang, R.-Z., & Yan, H. (2017) · Renewable Energy · doi:10.1016/j.renene.2017.06.058 · Cited by 19
Pu, J., Shen, C., Zhang, C., & Yan, X. (2022) · Energy and Buildings · doi:10.1016/j.enbuild.2022.111939 · Cited by 22
Defrosting on horizontal hydrophobic surfaces and the shrink angle
Chu, F., Wu, X.-M., & Zhu, Y. (2016) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2016.08.005 · Cited by 23
Lee, W.-J., Bae, K. J., & Kwon, O. K. (2020) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2020.115424 · Cited by 22
Asymmetric solidification during droplet freezing in the presence of a neighboring droplet
Castillo, J. E., Huang, Y., Pan, Z., & Weibel, J. A. (2021) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2021.121134 · Cited by 21
Ice nucleation in water droplets on glass surfaces: From micro- to macro-scale
Inada, T., Tomita, H., & Koyama, T. (2013) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2013.11.024 · Cited by 21
Chen, J., Wu, J., He, J., & Guo, Z. (2022) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2021.11.008 · Cited by 20
Wei, H., Li, Z., Guo, X., Yang, X., & Dong, W. (2021) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2021.122284 · Cited by 19
Liang, X.-Y., & Wu, L. (2022) · Energy and Buildings · doi:10.1016/j.enbuild.2022.112366 · Cited by 18
Experimental investigation of frost issue on various evaporators having different fin types
Olcay, A., Avci, P., Bayrak, E., Dalkılıç, A. S., & Wongwises, S. (2017) · International Communications in Heat and Mass Transfer · doi:10.1016/j.icheatmasstransfer.2017.05.029 · Cited by 20
The effect of surface modification on initial ice formation on aluminum surfaces
Rahimi, M., Afshari, A., Fojan, P., & Gurevich, L. (2015) · Applied Surface Science · doi:10.1016/j.apsusc.2015.06.201 · Cited by 18
Niu, J., Liang, Z., Lv, T., Wang, H., & Xu, S. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2024.122472 · Cited by 17
Tian, X., Jiao, W., Ren, L., Liu, S., & Liu, T. (2020) · Sustainable Cities and Society · doi:10.1016/j.scs.2020.102186 · Cited by 14
Effect of surface wettability on dust removal characteristics during frosting cleaning process
Li, Y., Li, M., & Dang, C. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.120592 · Cited by 14
Literature Review of Frost Formation Phenomena on Domestic Refrigerators Evaporators
Krasota, D., Błasiak, P., & Kolasiński, P. (2023) · Energies · doi:10.3390/en16072945 · Cited by 13
Experimental research on hot liquid defrosting system with multiple evaporators
Niu, J., Ma, G., & Xu, S. (2020) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2020.115710 · Cited by 12
Qu, M., Deng, S., & JIANG, Y. (2010) · International Journal of Air-Conditioning and Refrigeration · doi:10.1142/s2010132510000332 · Cited by 12
Energy-efficient defrosting of heat exchanger fins with embedded negative stiffness structures
Thakkar, A., Ma, J., Braun, J. E., Horton, W. T., & Arrieta, A. F. F. (2022) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2022.119850 · Cited by 11
Metadata
- Authors
- Jhee, S., Lee, K.-S., & Kim, W.-S.
- Affiliations
- Hanyang University (KR)
- Corresponding author
- Lee, Kwan-Soo
- Venue
- International Journal of Refrigeration
- Publisher
- Elsevier BV
- Published
- 2002-12
- Volume
- 25
- Issue
- 8
- Pages
- 1047-1053
- ISSN
- 0140-7007 (ISSN-L)
- OpenAlex
- W1981979778
- Cited by
- 149
- References
- 12
- Citations by year
- 2026: 3 · 2025: 10 · 2024: 4 · 2023: 6 · 2022: 6 · 2021: 13 · 2020: 13 · 2019: 8 · 2018: 8 · 2017: 16 · 2016: 8 · 2015: 8 · 2014: 7 · 2013: 11 · 2012: 5
- FWCI
- 5.09
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Refrigeration (publishedVersion)
- The Royal Society of Chemistry’s Journals, Books and Databases (The Royal Society of Chemistry) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
- Keywords
- finned tube heat exchanger, frost formation, thawing, surface treatment, hydrophilic surfaces, hydrophobic surfaces, aluminum heat exchangers, residual water, thermal performance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review