The DOI matches its Crossref record; 17 of the 19 references it cites were found in a registry or an index.
Dimensionless correlations of frost properties on a cold plate
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Yang and Lee [27] presented an experimental correlation for the average frost density as a function of the dimensionless temperature, humidity ratio, Reynolds number, and Fourier number.”
In the citing paper
“This correlation was further developed by Yang and Lee [89].”
From Review on the measurement and calculation of frost characteristics (2018) · cites this paper as [89]
In the citing paper
“As evaluated by Léoni et al. [118], Hermes et al. assumed that only mass diffusion occurs in the frost layer (0.5 exponents for the time) contrary to Yang and Lee [89].”
From Review on the measurement and calculation of frost characteristics (2018) · cites this paper as [89]
In the citing paper
“Yang and Lee ' s correlation [40] was very much similar to Mao et al. ' s correlation [36], and the difference between the two was mainly due to frosting condi tions.”
From Frosting mechanism and behaviors on surfaces with simple geometries: A state-of-the-art literature review (2022) · cites this paper as Yang and Lee [40]
In the citing paper
“Yang and Lee [40] believed that a dimensionless temperature based on air and cold surface temperatures can be used to replace frost surface temperature, and they presented a correlation of average frost density as a function of the dimensionless temperature, air moisture content, Reynolds number and heat transfer Fourier number.”
From Frosting mechanism and behaviors on surfaces with simple geometries: A state-of-the-art literature review (2022) · cites this paper as Yang and Lee [40]
Citations
Cites
(1953) · Mechanical Engineering · Cited by 6,608
Kraus, A. D., Welty, J. R., & Aziz, A. (2011) · CRC Press eBooks · doi:10.1201/b12301-22 · Cited by 4,223
HAYHURST, A. N. (1997) · Food engineering series · doi:10.1007/978-1-4615-3864-6_3 · Cited by 999
Study of frost properties correlating with frost formation types
Hayashi, Y., Aoki, A., Adachi, S., & Hori, K. (1977) · Journal of Heat Transfer · doi:10.1115/1.3450675 · Cited by 402
Equation of the growth rate of frost forming on cooled surfaces
Schneider, H. W. (1978) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(78)90098-4 · Cited by 148
Frost deposition on cold surfaces
Brian, P. L. T., Reid, R. C., & Shah, Y. T. (1970) · Industrial & Engineering Chemistry Fundamentals · doi:10.1021/i160035a013 · Cited by 142
(1967) · ASHRAE winter conference papers · Cited by 128
Frost growth parameters in a forced air stream
Östin, R., & Andersson, S. (1991) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(91)90012-4 · Cited by 116
Measurement and Correlation of Water Frost Thermal Conductivity and Density
Biguria, G., & Wenzel, L. A. (1970) · Industrial & Engineering Chemistry Fundamentals · doi:10.1021/i160033a021 · Cited by 75
Study on Properties and Growth Rate of Frost Layers on Cold Surfaces
Tokura, I., Saito, H., & Kishinami, K. (1983) · ASME Journal of Heat and Mass Transfer · doi:10.1115/1.3245679 · Cited by 50
Research works printed but not linked: 5
- Hosoda, 1967, Effects of frost on the heat transfer coefficient, Hitachi Review, 16, 254
- Mao, 1992, Measurement and correlations of frost properties with airflow over a flat plate, ASHRAE Transactions: Research, 91, 267
- Mao, 1999, Frost characteristics and heat transfer on a flat plate under freezer operating conditions, ASHRAE Transactions: Research, 105, 231
- Sherif, 1990, A semi-empirical transient method for modeling frost formation on a flat plate, ASHRAE Transactions, 139, 15
- O'Neal, 1985, A review of frost formation in simple geometries, ASHRAE Transactions, 91, 267
Cited by
Sorted by citations
A Review of Condensation Frosting
Nath, S., Ahmadi, S. F., & Boreyko, J. B. (2016) · Nanoscale and Microscale Thermophysical Engineering · doi:10.1080/15567265.2016.1256007 · Cited by 216
Review on the measurement and calculation of frost characteristics
Song, M., & Dang, C. (2018) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2018.03.094 · Cited by 212
Frost growth and densification in laminar flow over flat surfaces
Kandula, M. (2011) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2011.02.056 · Cited by 141
Shao, L.-L., Yang, L., & Zhang, C.-L. (2010) · Applied Energy · doi:10.1016/j.apenergy.2009.08.021 · Cited by 112
Frosting and defrosting characteristics of a fin according to surface contact angle
Kim, K., & Lee, K.-S. (2011) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2011.02.065 · Cited by 108
Self-citation
Metadata
- Authors
- Yang, D.-K., & Lee, K.-S.
- Affiliations
- Hanyang University (KR)
- Corresponding author
- Lee, Kwan-Soo
- ORCID
- Lee, Kwan-Soo
- Venue
- International Journal of Refrigeration
- Publisher
- Elsevier BV
- Published
- 2004-01
- Volume
- 27
- Issue
- 1
- Pages
- 89-96
- ISSN
- 0140-7007 (ISSN-L)
- OpenAlex
- W2091126511
- Cited by
- 134
- References
- 19
- Citations by year
- 2026: 7 · 2025: 11 · 2024: 8 · 2023: 6 · 2022: 14 · 2021: 10 · 2020: 3 · 2019: 9 · 2018: 4 · 2017: 10 · 2016: 8 · 2015: 6 · 2014: 9 · 2013: 4 · 2012: 3
- FWCI
- 5.35
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Refrigeration (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Keywords
- frost formation, dimensionless correlation, frost thickness, frost density, effective thermal conductivity, heat transfer coefficient, mass transfer coefficient, air velocity, absolute humidity, dimensional analysis, frost prediction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review