Perfusion magnetic resonance imaging with continuous arterial spin labeling: methods and clinical applications in the central nervous system
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Several methods are now available for measuring cerebral perfusion and related hemodynamic parameters using magnetic resonance imaging (MRI). One class of techniques utilizes electromagnetically labeled arterial blood water as a noninvasive diffusible tracer for blood flow measurements. The electromagnetically labeled tracer has a decay rate of T1, which is sufficiently long to allow perfusion of the tissue and microvasculature to be detected. Alternatively, electromagnetic arterial spin labeling (ASL) may be used to obtain qualitative perfusion contrast for detecting changes in blood flow, similar to the use of susceptibility contrast in blood oxygenation level dependent functional MRI (BOLD fMRI) to detect functional activation in the brain. The ability to obtain blood flow maps using a non-invasive and widely available modality such as MRI should greatly enhance the utility of blood flow measurement as a means of gaining further insight into the broad range of hemodynamically related physiology and pathophysiology. This article describes the biophysical considerations pertaining to the generation of quantitative blood flow maps using a particular form of ASL in which arterial blood water is continuously labeled, termed continuous arterial spin labeling (CASL). Technical advances permit multislice perfusion imaging using CASL with reduced sensitivity to motion and transit time effects. Interpretable cerebral perfusion images can now be reliably obtained in a variety of clinical settings including acute stroke, chronic cerebrovascular disease, degenerative diseases and epilepsy. Over the past several years, the technical and theoretical foundations of CASL perfusion MRI techniques have evolved from feasibility studies into practical usage. Currently existing methodologies are sufficient to make reliable and clinically relevant observations which complement structural assessment using MRI. Future technical improvements should further reduce the acquisition times for CASL perfusion MRI, while increasing the slice coverage, resolution and stability of the images. These techniques have a broad range of potential applications in clinical and basic research of brain physiology, as well as in other organs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230106 · Cited by 1,571
Self-citationMagnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
Self-citationMagnetization transfer contrast (MTC) and tissue water proton relaxation in vivo
Wolff, S. D., & Balaban, R. S. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910100113 · Cited by 1,482
THE DETERMINATION OF CEREBRAL BLOOD FLOW IN MAN BY THE USE OF NITROUS OXIDE IN LOW CONCENTRATIONS
Kety, S. S., & Schmidt, C. F. (1945) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1945.143.1.53 · Cited by 1,053
Kim, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340303 · Cited by 1,001
Caplan, L. R., & Hennerici, M. (1998) · Archives of Neurology · doi:10.1001/archneur.55.11.1475 · Cited by 869
Cerebral hemodynamics in ischemic cerebrovascular disease
Powers, W. J. (1991) · Annals of Neurology · doi:10.1002/ana.410290302 · Cited by 819
Alsop, D. C., & Detre, J. A. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199611000-00019 · Cited by 754
Self-citationEdelman, R. R., Siewert, B., Darby, D. G., Thangaraj, V, Nobre, A. C., Mesulam, M. M., & Warach, S. (1994) · Radiology · doi:10.1148/radiology.192.2.8029425 · Cited by 700
Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
Stehling, M. K., Turner, R., & Mansfield, P. (1991) · Science · doi:10.1126/science.1925560 · Cited by 623 · cited 1×
“Single excitation imaging techniques such as echoplanar imaging [24] have helped to dramatically reduce motion related errors.”
Background
Cited by
Neurocognitive consequences of sleep deprivation
Goel, N., Rao, H., Durmer, J., & Dinges, D. (2009) · Seminars in Neurology · doi:10.1055/s-0029-1237117 · Cited by 2,154
“A recently developed neuroimaging technique— arterial spin labeled (ASL) perfusion fMRI—utilizes magnetically labeled arterial blood water as a diffusible tracer for blood flow measurements in a manner analogous to that used for 15O-PET scanning.(154,155) This technique provides a noninvasive imaging method to quantif…”
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Dai, W., Garcia, D., de Bazelaire, C., & Alsop, D. C. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21790 · Cited by 985
Self-citationComparative Overview of Brain Perfusion Imaging Techniques
Wintermark, M., Sesay, M., Barbier, E., Borbély, K., Dillon, W. P., Eastwood, J. D., Glenn, T. C., Grandin, C. B., Pedraza, S., Soustiel, J.-F., et al. (2005) · Stroke · doi:10.1161/01.str.0000177884.72657.8b · Cited by 592
Johnson, N. A., Jahng, G.-H., Weiner, M. W., Miller, B. L., Chui, H. C., Jagust, W. J., Gorno-Tempini, M. L., & Schuff, N. (2005) · Radiology · doi:10.1148/radiol.2343040197 · Cited by 587
Culver, J. P., Durduran, T., Furuya, D., Cheung, C., Greenberg, J. H., & Yodh, A. G. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000076703.71231.bb · Cited by 420
Methodology of brain perfusion imaging
Barbier, E. L., Lamalle, L., & Décorps, M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1073 · Cited by 404
Circadian rhythms, sleep deprivation, and human performance
Goel, N., Basner, M., Rao, H., & Dinges, D. F. (2013) · Progress in Molecular Biology and Translational Science · doi:10.1016/b978-0-12-396971-2.00007-5 · Cited by 400
Fantini, S., Sassaroli, A., Tgavalekos, K. T., & Kornbluth, J. (2016) · Neurophotonics · doi:10.1117/1.nph.3.3.031411 · Cited by 397
Quantitative evaluation of oxygenation in venous vessels using T2‐Relaxation‐Under‐Spin‐Tagging MRI
Lu, H., & Ge, Y. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21627 · Cited by 360
Applications of arterial spin labeled MRI in the brain
Detre, J. A., Rao, H., Wang, D. J. J., Chen, Y. F., & Wang, Z. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23581 · Cited by 326
Self-citationArterial Spin-Labeling in Routine Clinical Practice, Part 1: Technique and Artifacts
Deibler, A. R., Pollock, J. M., Kraft, R. A., Tan, H., Burdette, J. H., & Maldjian, J. A. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1030 · Cited by 298
Barrett, T., Brechbiel, M., Bernardo, M., & Choyke, P. L. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20991 · Cited by 266
Efficiency of inversion pulses for background suppressed arterial spin labeling
Garcia, D. M., Duhamel, G., & Alsop, D. C. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20556 · Cited by 260
Self-citationASL Perfusion MRI Predicts Cognitive Decline and Conversion From MCI to Dementia
Chao, L. L., Buckley, S. T., Kornak, J., Schuff, N., Madison, C., Yaffe, K., Miller, B. L., Kramer, J. H., & Weiner, M. W. (2010) · Alzheimer Disease & Associated Disorders · doi:10.1097/wad.0b013e3181b4f736 · Cited by 257
Perfusion Imaging Using Arterial Spin Labeling
Golay, X., Hendrikse, J., & Lim, T. C. C. (2004) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-200402000-00003 · Cited by 256
What Stress Does to Your Brain: A Review of Neuroimaging Studies
Dedovic, K., D'Aguiar, C., & Pruessner, J. C. (2009) · The Canadian Journal of Psychiatry · doi:10.1177/070674370905400104 · Cited by 255
Aslan, S., Xu, F., Wang, P. L., Uh, J., Yezhuvath, U. S., van Osch, M., & Lu, H. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22245 · Cited by 246
“In CASL, due to long steady-state tagging, this technique often has high-power disposition and sometimes requires a second radiofrequency (RF) coil for spin labeling (14,15).”
BackgroundBiagi, L., Abbruzzese, A., Bianchi, M. C., Alsop, D. C., Del Guerra, A., & Tosetti, M. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20839 · Cited by 241
Self-citationClinical Neuroimaging Using Arterial Spin-Labeled Perfusion Magnetic Resonance Imaging
Wolf, R. L., & Detre, J. A. (2007) · Neurotherapeutics · doi:10.1016/j.nurt.2007.04.005 · Cited by 239
Self-citationTest–retest reliability of arterial spin labeling with common labeling strategies
Chen, Y., Wang, D. J. J., & Detre, J. A. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22345 · Cited by 238
“PASL methods use a short ( 10 msec) RF pulse to instantaneously invert blood spins in a thick slab while CASL uses either continuous wave RF or a long train of pulses ( 2 sec) to invert blood spins flowing through a labeling plane based on the principles of adiabatic fast passage (AFP) (1).”
MethodSelf-citationZhou, C., Yu, G., Furuya, D., Greenberg, J. H., Yodh, A. G., & Durduran, T. (2006) · Optics Express · doi:10.1364/oe.14.001125 · Cited by 232
Comparative overview of brain perfusion imaging techniques
Wintermark, M., Sesay, M., Barbier, E., Borbély, K., Dillon, W. P., Eastwood, J. D., Glenn, T. C., Grandin, C. B., Pedraza, S., Soustiel, J. F., et al. (2005) · Journal of Neuroradiology · doi:10.1016/s0150-9861(05)83159-1 · Cited by 185
Weber, M. J., Messing, S. B., Rao, H., Detre, J. A., & Thompson‐Schill, S. L. (2014) · Human Brain Mapping · doi:10.1002/hbm.22429 · Cited by 183
Self-citationCarhart-Harris, R. L., Murphy, K., Leech, R., Erritzoe, D., Wall, M. B., Ferguson, B., Williams, L. T. J., Roseman, L., Brugger, S., De Meer, I., et al. (2015) · Biological Psychiatry · doi:10.1016/j.biopsych.2013.12.015 · Cited by 178
“The magnetic resonance imaging technique ASL provides a quantitative measure of cerebral blood flow (CBF) or perfusion (19), and RSFC”
MethodShungu, D. C., Weiduschat, N., Murrough, J. W., Mao, X., Pillemer, S., Dyke, J. P., Medow, M. S., Natelson, B. H., Stewart, J. M., & Mathew, S. J. (2012) · NMR in Biomedicine · doi:10.1002/nbm.2772 · Cited by 178
“rCBF was measured in each participant with the same eightchannel head coil as used for the GSH scans, employing a pseudo-continuous spiral gradient echo ASL pulse sequence (13).”
BackgroundMethodInfluentialOn the Use of Caffeine as a Contrast Booster for BOLD fMRI Studies
Mulderink, T. A., Gitelman, D. R., Mesulam, M.-M., & Parrish, T. B. (2002) · NeuroImage · doi:10.1006/nimg.2001.0973 · Cited by 164
Flow Territory Mapping of the Cerebral Arteries With Regional Perfusion MRI
Hendrikse, J., van der Grond, J., Lu, H., van Zijl, P. C. M., & Golay, X. (2004) · Stroke · doi:10.1161/01.str.0000120312.26163.ec · Cited by 164
EFNS task force: the use of neuroimaging in the diagnosis of dementia
Filippi, M., Agosta, F., Barkhof, F., Dubois, B., Fox, N. C., Frisoni, G. B., Jack, C. R., Johannsen, P., Miller, B. L., Nestor, P. J., et al. (2012) · European Journal of Neurology · doi:10.1111/j.1468-1331.2012.03859.x · Cited by 141
Michalon, A., Bruns, A., Risterucci, C., Honer, M., Ballard, T. M., Ozmen, L., Jaeschke, G., Wettstein, J. G., von Kienlin, M., Künnecke, B., et al. (2014) · Biological Psychiatry · doi:10.1016/j.biopsych.2013.05.038 · Cited by 67
A VBM study demonstrating ‘apparent’' effects of a single dose of medication on T1-weighted MRIs
Franklin, T. R., Wang, Z., Shin, J., Jagannathan, K., Suh, J. J., Detre, J. A., O’Brien, C. P., & Childress, A. R. (2013) · Brain Structure and Function · doi:10.1007/s00429-012-0385-6 · Cited by 57
Self-citation
Metadata
- Authors
- Detre, J. A., & Alsop, D. C.
- Venue
- European Journal of Radiology
- Publisher
- Elsevier BV
- Published
- 1999-05
- Volume
- 30
- Issue
- 2
- Pages
- 115-124
- ISSN
- 0720-048X (ISSN-L)
- OpenAlex
- W2135304097
- Cited by
- 299
- References
- 41
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.