Perfusion magnetic resonance imaging with continuous arterial spin labeling: methods and clinical applications in the central nervous system
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Several methods are now available for measuring cerebral perfusion and related hemodynamic parameters using magnetic resonance imaging (MRI). One class of techniques utilizes electromagnetically labeled arterial blood water as a noninvasive diffusible tracer for blood flow measurements. The electromagnetically labeled tracer has a decay rate of T1, which is sufficiently long to allow perfusion of the tissue and microvasculature to be detected. Alternatively, electromagnetic arterial spin labeling (ASL) may be used to obtain qualitative perfusion contrast for detecting changes in blood flow, similar to the use of susceptibility contrast in blood oxygenation level dependent functional MRI (BOLD fMRI) to detect functional activation in the brain. The ability to obtain blood flow maps using a non-invasive and widely available modality such as MRI should greatly enhance the utility of blood flow measurement as a means of gaining further insight into the broad range of hemodynamically related physiology and pathophysiology. This article describes the biophysical considerations pertaining to the generation of quantitative blood flow maps using a particular form of ASL in which arterial blood water is continuously labeled, termed continuous arterial spin labeling (CASL). Technical advances permit multislice perfusion imaging using CASL with reduced sensitivity to motion and transit time effects. Interpretable cerebral perfusion images can now be reliably obtained in a variety of clinical settings including acute stroke, chronic cerebrovascular disease, degenerative diseases and epilepsy. Over the past several years, the technical and theoretical foundations of CASL perfusion MRI techniques have evolved from feasibility studies into practical usage. Currently existing methodologies are sufficient to make reliable and clinically relevant observations which complement structural assessment using MRI. Future technical improvements should further reduce the acquisition times for CASL perfusion MRI, while increasing the slice coverage, resolution and stability of the images. These techniques have a broad range of potential applications in clinical and basic research of brain physiology, as well as in other organs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230106 · Cited by 1,571
Self-citationMagnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
Self-citationMagnetization transfer contrast (MTC) and tissue water proton relaxation in vivo
Wolff, S. D., & Balaban, R. S. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910100113 · Cited by 1,482
THE DETERMINATION OF CEREBRAL BLOOD FLOW IN MAN BY THE USE OF NITROUS OXIDE IN LOW CONCENTRATIONS
Kety, S. S., & Schmidt, C. F. (1945) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1945.143.1.53 · Cited by 1,053
Kim, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340303 · Cited by 1,001
Caplan, L. R., & Hennerici, M. (1998) · Archives of Neurology · doi:10.1001/archneur.55.11.1475 · Cited by 869
Cerebral hemodynamics in ischemic cerebrovascular disease
Powers, W. J. (1991) · Annals of Neurology · doi:10.1002/ana.410290302 · Cited by 819
Alsop, D. C., & Detre, J. A. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199611000-00019 · Cited by 754
Self-citationEdelman, R. R., Siewert, B., Darby, D. G., Thangaraj, V, Nobre, A. C., Mesulam, M. M., & Warach, S. (1994) · Radiology · doi:10.1148/radiology.192.2.8029425 · Cited by 700
Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
Stehling, M. K., Turner, R., & Mansfield, P. (1991) · Science · doi:10.1126/science.1925560 · Cited by 623 · cited 1×
“Single excitation imaging techniques such as echoplanar imaging [24] have helped to dramatically reduce motion related errors.”
BackgroundMr perfusion studies with t1‐weighted echo planar imaging
Kwong, K. K., Chesler, D. A., Weisskoff, R. M., Donahue, K. M., Davis, T. L., Ostergaard, L., Campbell, T. A., & Rosen, B. R. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340613 · Cited by 477
Multisection cerebral blood flow MR imaging with continuous arterial spin labeling.
Alsop, D. C., & Detre, J. A. (1998) · Radiology · doi:10.1148/radiology.208.2.9680569 · Cited by 404
Self-citationControl of Cerebral Circulation in Health and Disease
LASSEN, N. A. (1974) · Circulation Research · doi:10.1161/01.res.34.6.749 · Cited by 400
Tissue specific perfusion imaging using arterial spin labeling
Detre, J. A., Zhang, W., Roberts, D. A., Silva, A. C., Williams, D. S., Grandis, D. J., Koretsky, A. P., & Leigh, J. S. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070112 · Cited by 335
Self-citationYe, F. Q., Mattay, V. S., Jezzard, P., Frank, J. A., Weinberger, D. R., & McLaughlin, A. C. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370215 · Cited by 294
Projection angiograms of blood labeled by adiabatic fast passage
Dixon, W. T., Du, L. N., Faul, D. D., Gado, M., & Rossnick, S. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030311 · Cited by 282
Webster, M. W., Makaroun, M. S., Steed, D. L., Smith, H. A., Johnson, D. W., & Yonas, H. (1995) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(95)70274-1 · Cited by 262
Course of cerebrovascular reactivity in patients with carotid artery occlusions.
Widder, B., Kleiser, B., & Krapf, H. (1994) · Stroke · doi:10.1161/01.str.25.10.1963 · Cited by 228
Noninvasive MRI evaluation of cerebral blood flow in cerebrovascular disease
Detre, J. A., Alsop, D. C., Vives, L. R., Maccotta, L., Teener, J. W., & Raps, E. C. (1998) · Neurology · doi:10.1212/wnl.50.3.633 · Cited by 209
Self-citationRoberts, D. A., Detre, J. A., Bolinger, L., Insko, E. K., & Leigh, J. S. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.1.33 · Cited by 177
Self-citationIs Impaired Cerebral Vasomotor Reactivity a Predictive Factor of Stroke in Asymptomatic Patients?
Gur, A. Y., Bova, I., & Bornstein, N. M. (1996) · Stroke · doi:10.1161/01.str.27.12.2188 · Cited by 160
NMR Measurement of Perfusion Using Arterial Spin Labeling Without Saturation of Macromolecular Spins
Zhang, W., Silva, A. C., Williams, D. S., & Koretsky, A. P. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330310 · Cited by 158
Multi‐Slice MRI of Rat Brain Perfusion During Amphetamine Stimulation Using Arterial Spin Labeling
Silva, A. C., Zhang, W., Williams, D. S., & Koretsky, A. P. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330210 · Cited by 156
Predictors of outcome after anterior temporal lobectomy
Manno, E. M., Sperling, M. R., Ding, X., Jaggi, J. L., Alavi, A. A., O’Connor, M. J., & Reivich, M. (1994) · Neurology · doi:10.1212/wnl.44.12.2321 · Cited by 156
Perfusion imaging with compensation for asymmetric magnetization transfer effects
Pekar, J., Jezzard, P., Roberts, D. A., Leigh, J. S., Frank, J. A., & McLaughlin, A. C. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350110 · Cited by 155
Clinical and hemodynamic aspects of low-flow infarcts.
Weiller, C., Ringelstein, E. B., Reiche, W., & Buell, U. (1991) · Stroke · doi:10.1161/01.str.22.9.1117 · Cited by 147
Powers, W. J., Tempel, L. W., & Grubb, R. L. (1989) · Annals of Neurology · doi:10.1002/ana.410250403 · Cited by 133
Zhang, W., Williams, D. S., Detre, J. A., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250216 · Cited by 122
Self-citationGaillard, W. D., Fazilat, S., White, S., Malow, B. A., Sato, T. S., Reeves, P., Herscovitch, P., & Theodore, W. H. (1995) · Neurology · doi:10.1212/wnl.45.10.1841 · Cited by 104
Mull, M., Schwarz, M., & Thron, A. K. (1997) · Stroke · doi:10.1161/01.str.28.1.118 · Cited by 103
Ringelstein, E. B., Weiller, C., Weckesser, M., & Weckesser, S. (1994) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(94)90163-5 · Cited by 96
The efficiency of adiabatic inversion for perfusion imaging by arterial spin labeling
Maccotta, L., Detre, J. A., & Alsop, D. C. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<216::aid-nbm468>3.0.co;2-u · Cited by 93
Self-citationLeblanc, R., Yamamoto, Y. L., Tyler, J. L., Dikšić, M., & Hakim, A. M. (1987) · Annals of Neurology · doi:10.1002/ana.410220606 · Cited by 72
Leiderman, D. B., Balish, M., Sato, S., Kufta, C. V., Reeves, P., Gaillard, W. D., & Theodore, W. H. (1992) · Epilepsy Research · doi:10.1016/0920-1211(92)90071-z · Cited by 71
Noninvasive perfusion MRI in Alzheimer's disease: A preliminary report
Sandson, T. A., O'Connor, M., Sperling, R. A., Edelman, R. R., & Warach, S. (1996) · Neurology · doi:10.1212/wnl.47.5.1339 · Cited by 67
Borderzone hemodynamics in cerebrovascular disease
Carpenter, D. A., Grubb, R. L., & Powers, W. J. (1990) · Neurology · doi:10.1212/wnl.40.10.1587 · Cited by 52
STAR‐HASTE: Perfusion imaging without magnetic susceptibility artifact
Chen, Q., Siewert, B., Bly, B. M., Warach, S., & Edelman, R. R. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380308 · Cited by 50
Functional MRI using steady‐state arterial water labeling
Talagala, S. L., & Noll, D. C. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390203 · Cited by 42
Siewert, B., Bly, B. M., Schlaug, G., Darby, D., Thangaraj, V., Warach, S. J., & Edelman, R. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360212 · Cited by 37
Grieve (2000) · doi:10.1002/(sici)1522-2594(200005)43:5
Cited by
Neurocognitive consequences of sleep deprivation
Goel, N., Rao, H., Durmer, J., & Dinges, D. (2009) · Seminars in Neurology · doi:10.1055/s-0029-1237117 · Cited by 2,154
“A recently developed neuroimaging technique— arterial spin labeled (ASL) perfusion fMRI—utilizes magnetically labeled arterial blood water as a diffusible tracer for blood flow measurements in a manner analogous to that used for 15O-PET scanning.(154,155) This technique provides a noninvasive imaging method to quantif…”
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Dai, W., Garcia, D., de Bazelaire, C., & Alsop, D. C. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21790 · Cited by 985
Self-citationComparative Overview of Brain Perfusion Imaging Techniques
Wintermark, M., Sesay, M., Barbier, E., Borbély, K., Dillon, W. P., Eastwood, J. D., Glenn, T. C., Grandin, C. B., Pedraza, S., Soustiel, J.-F., et al. (2005) · Stroke · doi:10.1161/01.str.0000177884.72657.8b · Cited by 592
Johnson, N. A., Jahng, G.-H., Weiner, M. W., Miller, B. L., Chui, H. C., Jagust, W. J., Gorno-Tempini, M. L., & Schuff, N. (2005) · Radiology · doi:10.1148/radiol.2343040197 · Cited by 587
Metadata
- Authors
- Detre, J. A., & Alsop, D. C.
- Venue
- European Journal of Radiology
- Publisher
- Elsevier BV
- Published
- 1999-05
- Volume
- 30
- Issue
- 2
- Pages
- 115-124
- ISSN
- 0720-048X (ISSN-L)
- OpenAlex
- W2135304097
- Cited by
- 299
- References
- 41
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.